• 제목/요약/키워드: Power Measurement

검색결과 4,630건 처리시간 0.038초

고조파전류 측정에 근거한 국내 고조파 관리기준 검토 (Examination of the domestic harmonic standard introduction based on measurement of harmonic current)

  • 박용업;강문호;이남우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.539-540
    • /
    • 2007
  • In order to increase an efficiency of electric machine, the power electric devices are rapidly increasing of late. These electric components are mainly caused to lower of power quality. To take precautions against lower of power quality, the advanced countries already made effort to control of harmonic level. For these harmonic control of advanced countries have applied harmonic planning level, emission of harmonic based on the technical calculation and experiment. In this paper, we have investigated the introduction abroad advanced country standard through compared IEEE, IEC with the real measurement of domestic harmonic level.

  • PDF

전력설비의 신뢰성 향상을 위한 불량애자검출기법의 비교 (Comparison of the Poor Insulator Detecting Technique for the Reliability Enhancement of the Electric Power Facilities)

  • 정순원;구경완
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.417-423
    • /
    • 2008
  • For the evaluation in the safety of outdoor insulator, there are various methods such as: visual observation; voltage measurement; use of ultrasonic wave due to partial discharge; electric field measurement; use of infrared/ultraviolet sensor-type camera. However, many problems have been issued regrading the reliability of the evaluation test and safety of testing operation. Accordingly, the present study has investigated and analyzed the characteristics and mechanisms of the insulator deterioration, in order to obtain an optimal method for detecting poor insulator so that the reliability of power facilities can be enhanced. Besides, based on theoretical analysis of domestic and international detection methods for poor insulator, the reliability has been compared and evaluated quantitatively. As a result, it was shown that the corona camera would be the best choice for domestic workplace application in detecting poor insulator for enhancing the reliability of power transmission line.

Manufacturing of Cs3Sb Photocathode in Atmospheric Conditions

  • Jeong, Hyo-Soo
    • 한국전기전자재료학회논문지
    • /
    • 제27권10호
    • /
    • pp.653-656
    • /
    • 2014
  • $Cs_3Sb$ photocathode was formed by newly developed process and successive in-situ lighting devices were fabricated in a process chamber. R, G, and B phosphors were applied on the anode plate, respectively. Major parameters such as brightness, power consumption, and efficacy were measured. The wavelength of LED excitation source was 450 nm. Both high power and low power modes were applied in the measurement. Measurement values were clearly differentiated by the voltage application modes. The measured values of each parameter was good enough to be applied for general lighting source. The results showed that $Cs_3Sb$ photocathode formed in atmospheric conditions was functioning as good as the photocathode formed in UHV conditions, and thus it could be applied to advanced lighting devices.

Application of particle filtering for prognostics with measurement uncertainty in nuclear power plants

  • Kim, Gibeom;Kim, Hyeonmin;Zio, Enrico;Heo, Gyunyoung
    • Nuclear Engineering and Technology
    • /
    • 제50권8호
    • /
    • pp.1314-1323
    • /
    • 2018
  • For nuclear power plants (NPPs) to have long lifetimes, ageing is a major issue. Currently, ageing management for NPP systems is based on correlations built from generic experimental data. However, each system has its own characteristics, operational history, and environment. To account for this, it is possible to resort to prognostics that predicts the future state and time to failure (TTF) of the target system by updating the generic correlation with specific information of the target system. In this paper, we present an application of particle filtering for the prediction of degradation in steam generator tubes. With a case study, we also show how the prediction results vary depending on the uncertainty of the measurement data.

고속 전력선 통신을 위한 중전압 선로의 방사전자파 측정 및 분석 (Emissive Electromagnetic Field Measurement and Analysis for High Speed PLC on Medium Voltage Power-Line Channel)

  • 김선효;김상태;이영철;신철재
    • 한국전자파학회논문지
    • /
    • 제14권1호
    • /
    • pp.54-61
    • /
    • 2003
  • 본 논문은 중 전압 전력선(22.9 kV)에서 방사되는 전자파 특성결과를 보여주고 있다. 측정은 주파수범위 9 kHz∼30 MHz의 통신 신호를 중 전압 전력선로에 인가하였을 때 측정을 하였다. 측정결과 단일 반송신호보다 다중 반송신호에서 방사되는 전자파의 특성이 우수하며 다중반송신호의 세기가 20 dBm일 때 전력선 통신 신호는 1.8 km까지 전송 가능함을 알 수가 있었다. 전기장의 세기는 10 m 법으로 측정하였을 때 30 MHz에서 40 dBuV/m이하의 값을 볼 수가 있었다.

CPX 및 Pass-by 계측을 이용한 단독 주행 차량의 음향파워 평가 방법에 관한 연구 (A Study on the Evaluation Method of Sound Power for a Travelling Vehicle Using CPX and Pass-by Measurements)

  • 최태묵;문성호;서영국;김진형;김병희;배효준;지우진;조대승
    • 한국소음진동공학회논문집
    • /
    • 제16권11호
    • /
    • pp.1124-1131
    • /
    • 2006
  • This paper presents a novel method to determine sound power level(PWL) emitted by a travelling vehicle for road traffic noise simulation. The PWL is evaluated by the equivalent sound pressure level (SPL) measured by close proximity method and the sound power correction factor derived from the maximum SPL measured by pass-by method and the propagation attenuation of vehicle noise during the pass-by measurement. Using the method, we derive the empirical formula for PWL estimation in 1/1-octave and overall frequency bands for 8 vehicles (automobile, SUV, small truck, large bus, trailer, 3 dump trucks) tested at two road surfaces (dense graded asphalt, 30mm transverse tinning concrete) of Korean highway test road. The suggested approach, if securing sufficient data to represent the acoustic characteristics of all vehicle types, has il strong merit to be able to evaluate sound power levels for any combination of vehicle categories and traffic volumes.

새만금 고군산군도의 풍자원 측정 및 분석 (Measurement and Analysis of Wind Energy Potential in Kokunsando of Saemankeum)

  • 심애리;최연성;이장호
    • 신재생에너지
    • /
    • 제7권2호
    • /
    • pp.51-58
    • /
    • 2011
  • Saemankeum is well known for its high speed wind, and it is known that the blueprint of a future city around Saemankeum, including new industrial complex, has been planned. As a result, large-scale offshore wind farm, on the basis of the measurement of wind resource for a long time, can be considered, so that generated electricity can be used to meet the energy demand near the wind farm. Wind speed in Kokunsando of Saemankeum is measured and analyzed with its statistical distribution and wind directions. The probability of wind power resource over Kokunsando of Saemangeum is reviewed with the measured data in one island of Kokunsando. According to measured data, the shape and scale factor of Weibull distribution of wind speed are obtained, and then power density is analyzed as well. Through this study, it is clear that the Saemangeum area has a fluent and abundant wind power source to develop the wind farm in Korea.

기판에 따른 BST 박막의 RF Power 의존성 (Study on RF power dependence of BST thin film by the different substrates)

  • 최명률;이태일;박인철;김홍배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.22-25
    • /
    • 2002
  • In this paper, we deposited MgO buffer layer on p-type (100)Si substrate in the condition of substrate temperature 400$^{\circ}C$, working gas ratio Ar:O$_2$=80:20, RF Power 50W, working pressure 10mtorr, and the thickness of the film was about 300${\AA}$. Then we deposited Ba$\sub$0.5/Sr$\sub$0.5/TiO$_3$ thin film using RF Magnetron sputtering method on the MgO/Si substrate in various RF power of 25W, 50W, 75W. The film deposited in 50W showed the best crystalline from the XRD measurement. To know the electrical properties of the film, we manufactured Al/BSTMgO(300${\AA}$)/Si/Al structure capacitor. In the result of I-V measurement, The leakage current density of the capacitor was lower than 10$\^$-7/A/$\textrm{cm}^2$ at the range of ${\pm}$150kV/cm. From C-V characteristics of the capacitor, can calculate the dielectric constant and it was 305. Finally we deposited BST thin film on bare Si substrate and (100)MgO substrate in the same deposition condition. From the comparate of the properties of these samples, we found the properties of BST thin film which deposited on MgO/Si substrate were better than on bare Si substrate and similar to on MgO substrate.

  • PDF

자동차 타이어 손상에 의한 초음파 신호 주기 측정에 관한 연구 (On the Study of the Period Measurement of Ultrasonic Signal in Damaged Vehicle Tire)

  • 박정임;임승각;강대수
    • 한국인터넷방송통신학회논문지
    • /
    • 제11권5호
    • /
    • pp.47-52
    • /
    • 2011
  • 본 논문에서는 주행 중 타이어와 노면이 마찰하면서 발생하는 초음파 신호에서 이물질로 인해 야기되는 우성주기를 검출하여 타이어 손상 유무를 판별하는 알고리즘에 대해 연구하였다. 손상된 타이어에서 획득한 초음파 신호의 포락선에 대해 전력스펙트럼을 산출하고 통계적 처리에 의한 임계값을 설정함으로써 우성주기를 판별하는 알고리즘을 제안하였다. 모의실험 결과, 시속 80km/h로 주행 시 초음파 신호의 포락선에 대해 전력스펙트럼의 피크주기 97.6ms에 비해 제안된 알고리즘의 우성주기는 100ms로서 포락선 피크의 평균주기 101.24ms를 기준으로 하였을 때 더 정확한 주기 측정 결과를 보였다.

CPX 및 Pass-by 계측을 이용한 단독 주행 차량의 음향파워 평가 방법에 관한 연구 (A Study on the Evaluation Method of Sound Power for a Travelling Vehicle Using CPX and Pass-by Measurements)

  • 최태묵;문성호;서영국;김진형;김병희;배효준;조대승
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.421-427
    • /
    • 2006
  • This paper presents a novel method to determine sound power level(PWL) emitted by a travelling vehicle for road traffic noise simulation. The PWL is evaluated by the equivalent sound pressure level(SPL) measured by close proximity method and the sound power correction factor derived from the maximum SPL measured by pass-by method and the propagation attenuation of vehicle noise during the pass-by measurement. Using the method, we derive the empirical formula for PWL estimation in 1/1-octave and overall frequency bands for 8 vehicles(automobile, SUV, small truck, large bus, trailer, 3 dump trucks) tested at two road surfaces(dense graded asphalt, 30mm transverse tinning concrete) of Korean highway test road. The suggested approach, if securing sufficient data to represent the acoustic characteristics of au vehicle types, has a strong merit to be able to evaluate sound power levels for any combination of vehicle categories and traffic volumes.

  • PDF