전력계통 전력품질 통합진단시스템 개발 (The Development of Integrated Power Quality Diagnosis System for Power System)

  • 곽노홍;전영수;박상호;이일무;박희철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.277-279
    • /
    • 2005
  • Recently, due to the increase of power conversion devices and nonlinear loads with the development of information, communication and control technologies, the instantaneous minute interruption factors such as voltage & current harmonics, surge occurring frequency, instantaneous voltage variation, voltage unbalance, flicker etc. have greatly threatened the power quality, and the deterioration of electric power facilities and the functional error of controllers are increasing. As such an instantaneous minute interruption appears to be small and local, accurate evaluation with measurement is difficult and total analysis system is required through a wide range of power quality effect analysis such as the simultaneous measurement on various power supply phenomena and the analysis on the interrelation with system loads. Most of conventional power quality diagnosis equipments have beer developed and applied, which were able to measure the stability rate of frequency, the stability rate of voltage, the electricity-failure duration etc, However, they were insufficient to analyze the system present situation, understand the cause of the failure occurred by the problem of power quality and analyze out the phenomena. Accordingly, this study will address the development of the system for a wide range of power quality diagnosis over the present level, the system for supporting the determination such as the analysis on risk factors, failure mode and impact, the system for harmonic evaluation based on international standards(IEC 61000 Series) and the total power quality diagnosis network & system with the extension and openness as a local and national-scale broadband power quality diagnosis system.

  • PDF

초음파 파워 측정 시스템 구성 및 성능평가 (Construction of Ultrasonic Power Measurement System and Its Performance Evaluation)

  • 조문재;김용태;윤용현;정성수
    • 한국음향학회지
    • /
    • 제24권8호
    • /
    • pp.431-440
    • /
    • 2005
  • 초음파 파워의 정확한 측정은 초음파 의료 장비의 품질 보증과 안전성에 중요하다. 본 논문에서는 초음파 조사가 on/off를 반복하는 동안의 표적에 작용하는 방사 힘과 부력과 같은 다른 원인에서 기인하는 저울 지시 값의 시간에 따른 변화로부터 초음파 파워를 결정하는 간단한 이론을 제시하였다. 아울러 개발된 초음파 파워 측정 시스템에 대해 정밀 기계적 정렬장치, 전기신호 발생부 구성, 제어 및 측정부 구성 및 적절한 절차와 함께 상세히 기술하였다. 본 시스템으로 1 MHz, 5 MHz, 10 MHz, 15 MHz에서 10 mW에서 10 W범위에 걸쳐 측정된 결과를 다른 나라에서 교정된 기준 데이터와 상호 비교한 결과 상대 편차가 $5\%$ 이내로 확인되었다.

초음파법을 이용한 Cr-Mo강 고온배관재료의 크리프손상 평가 (Creep Damage Evaluation of Cr-Mo Steel High-Temperature Pipeline Material for Fossil Power Plant Using Ultrasonic Test Method)

  • 이상국
    • 비파괴검사학회지
    • /
    • 제20권1호
    • /
    • pp.18-26
    • /
    • 2000
  • 화력발전소 보일러 고온배관인 주증기관, 헤드 및 증기드럼 등의 설비들은 장시간동안 고온고압의 가혹한 조건으로 운전됨에 따라 크리프손상에 의해 열화되고 있다. 이들 설비의 크리프손상측정에 적용되는 종래의 비파괴기법인 레프리카법, 전기저항법 및 경도법 등은 복잡한 측정절차 및 접근성, 검사결과의 신뢰도 및 측정정도 등 여러가지면에서 단점이 많다. 따라서 본 논문에서는 화력발전소 주요 고온배관에서 발생되는 경년열화인 크리프손상에 대한초음파 측정연구를 수행한 결과로서, 고온배관재료인 Cr-Mo강의 크리프 인공열화재를 대상으로 이들에 대한 크리프손상 상태별 초음과 음속(sound velocity) 및 감쇠(attenuation)의 초음파 신호특성을 평가하였다.

  • PDF

CDMA 기지국에서 Pilot $E_c/I_o$ 보상기법을 이용한 수신감도 측정에 관한 연구 (A Study on Receiver Sensitivity Measurement using Pilot $E_c/I_o$ Compensation Method at CDMA Communication Network)

  • 정기혁;나극환
    • 대한전자공학회논문지TC
    • /
    • 제44권8호
    • /
    • pp.9-16
    • /
    • 2007
  • 운용중인 기지국에서 각종 RF 파라미터의 측정은 매우 제한적으로 이루어지고 있으며, 일부 수행되고 있는 측정에서 조차 비교적 측정이 용이한 순방향 항목에 집중되고 있다. 본 논문에서는 기지국에 설치된 순방향 모니터링 포트를 이용하여 기지국의 역방향의 무선 품질을 측정이 기능한 측정장치를 설계하여 실제 운용 중인 기지국에서 검증시험을 실시함으로써 연구의 완성도 향상을 꾀하였다. 수신감도의 측정은 내장된 CDMA 모뎀을 이용하여 기지국과 음성호가 연결된 상태에서 폐루프 전력제어에 의한 모뎀의 출력을 감시함으로써 이루어질 수 있도록 하였다. 보다 정확한 계측을 위하여 모뎀의 TxAdj 파라미터와 함께 디텍터에 의한 실측 데이터를 이용하였다. 정확한 수신감도의 측정을 위해서는 트래픽이 없는 상황에서 측정이 이루어져야 하지만, 운용중인 시스템에서는 상황재현이 어려우므로 통화량 증가에 의한 수신감도의 열화정도를 보상함으로써 시간에 구애받지 않고 정확한 측정값을 얻을 수 있도록 $E_c/I_o$에 의한 보상기법을 적용하였다.

오프셋 전압 보상이 적용된 지연 선로 구조의 C 대역 순시 주파수 측정용 수신기 설계 및 제작 (Design and Fabrication of a C-Band Delay Line Instantaneous Frequency Measurement Receiver with Offset Voltage Compensation)

  • 전문수;전여옥;서원구;배경태;김동욱
    • 한국전자파학회논문지
    • /
    • 제27권1호
    • /
    • pp.42-49
    • /
    • 2016
  • 본 논문에서는 지연 선로의 경로차를 이용하여 4~6 GHz의 연속파 신호를 감지하여 125 MHz의 해상도로 순시 주파수를 측정하는 순시 주파수 측정용 수신기를 설계 및 제작하였다. 수신기는 4 비트 지연 선로 구조를 가졌으며, 전력 분배기, 지연 선로, 전력 합성기, 전력 검파기, 비교기 등으로 구성되었다. 각각의 비트에 배정된 지연 선로의 주파수에 따른 경로 손실 차이를 보상하고, 전력 검파 특성의 주파수 의존성을 보정하기 위해 오프셋 전압 보상을 비교기에 적용하여 측정의 정확성을 향상시켰다.

154kV 전력케이블용 XLPE 절연체와 반도전 재료의 비열 및 열전도 (Specific Heat and Thermal Conductivity of XLPE Insulator and Semiconductive Materials for 154kV Power Cable)

  • 이경용;양종식;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.19-24
    • /
    • 2005
  • To improve mean-life and reliability of power cable, we have investigated specific heat (Cp) and thermal conductivity of XLPE insulator and semiconductive materials in 154kV underground power transmission cable. Specimens were respectively made of sheet form with EVA, EEA and EBA added 30wt%, carbon black, and the other was made of sheet form by cutting XLPE insulator in 154kV power cable. Specific heat (Cp) and thermal conductivity were· measured by DSC (Differential Scanning Calorimetry) and Nano Flash Diffusivity. Specific-heat measurement temperature ranges of XLPE insulator were from 20[$^{\circ}C$] to 90[$^{\circ}C$], and the heating rate was 1[$^{\circ}C$/min]. And the measurement temperatures of thermal conductivity were 25[$^{\circ}C$}], 55[$^{\circ}C$] and 90[$^{\circ}C$]. In case of semiconductive materials, the measurement temperature ranges of specific heat were from 20[$^{\circ}C$] to 60[$^{\circ}C$], and the heating rate was 1[$^{\circ}C$/min]. And the measurement temperatures of thermal conductivity were 25[$^{\circ}C$] and 55[$^{\circ}C$]. From these experimental results, both specific heat and thermal conductivity were increased by heating rate because volume of materials was expanded according to rise in temperature.

  • PDF

Measurement of Multimode Fiber Bandwidth by the Fourth-Order Spectra of Amplified Spontaneous Emission

  • Moon, Sucbei;Kim, Dug Young
    • Journal of the Optical Society of Korea
    • /
    • 제18권1호
    • /
    • pp.15-22
    • /
    • 2014
  • We present a novel bandwidth measurement scheme for multimode optical fibers. Amplified spontaneous emission (ASE) radiation was utilized for a source of intrinsically modulated light with a wide modulation bandwidth. In our measurement scheme, the continuous-wave (CW) ASE light that passed through a multimode fiber (MMF) under test was analyzed by the fourth-order power with a high-speed photodetector and an electric spectrum analyzer. The modulation transfer function of the multimode fiber could be directly measured with the photoelectric spectra in the modulation frequency domain. The measurement result of our method was experimentally compared to that of the conventional measurement scheme based on the impulse response measurement. It has been found that our scheme provides a stable measurement means of MMF characterization that is suitable for the field testing due to the simplicity of the system.

LTE와 IoT 기술을 이용한 스마트미터 데이터 전송장치와 전력 IT 시스템 (Smart meter data transmission device and power IT system using LTE and IoT technologies)

  • 강기범;김홍수;좌정우;김호찬;강민제
    • 한국산학기술학회논문지
    • /
    • 제18권10호
    • /
    • pp.117-124
    • /
    • 2017
  • 스마트 그리드는 기존 전력망에 ICT기술을 접목하여 소비자와 전력 공급자 간 양방향으로 실시간 정보를 교환함으로써 에너지를 효율적으로 사용 할 수 있는 시스템이다. 수요반응(DR, Demand response)은 전기사용자가 전력시장 가격이 높거나 전력계통 위기일 때 절약한 전기를 전력시장에 판매하여 금전으로 보상받는 제도이다. 본 논문은 스마트 미터(Smart Meter)를 사용하여 실시간으로 수요 정보를 계측하고 이를 클라우드 서버로 전송하는 전력량 계측 데이터 전송장치와 전력 IT 시스템을 개발하였다. 본 논문에서 개발된 전력량 계측 데이터 전송장치는 한국전력 데이터와 측정 오차가 없는 신뢰성이 있는 데이터를 제공하기 위해 Raspberry Pi 3에 연결된 빛 센서를 이용하여 한국전력 계측기의 전력량 단위마다 깜박이는 램프의 횟수를 계측한다. 전력량 계측 데이터 전송 장치는 표준 통신 프로토콜인 OpenADR 2.0b를 사용한다. 계측된 데이터는 LTE, WiFi 통신망을 통해 VEN, VTN, 계산 프로그램으로 구성되는 전력 IT 시스템의 MySQL DB에 저장된다. 개발된 전력량 계측 데이터 전송 장치는 전력계통 위기가 발생할 때 급전지시를 내려 피크감축 DR을 실행한다. 개발한 전력량 계측 데이터 전송 장치는 기존 스마트 미터링의 계측시간이 15분으로 고정되는 것과 달리 사용자가 1분 단위로 조절할 수 있는 장점을 갖는다.

ASSESSMENT OF POSSIBILITY OF PRIMARY WATER STRESS CORROSION CRACKING OCCURRENCE BASED ON RESIDUAL STRESS ANALYSIS IN PRESSURIZER SAFETY NOZZLE OF NUCLEAR POWER PLANT

  • Lee, Kyoung-Soo;Kim, W.;Lee, Jeong-Geun
    • Nuclear Engineering and Technology
    • /
    • 제44권3호
    • /
    • pp.343-354
    • /
    • 2012
  • Primary water stress corrosion cracking (PWSCC) is a major safety concern in the nuclear power industry worldwide. PWSCC is known to initiate only in the condition in which sufficiently high tensile stress is applied to alloy 600 tube material or alloy 82/182 weld material in pressurized water reactor operating environments. However, it is still uncertain how much tensile stress is re-quired to generate PWSCC or what causes such high tensile stress. This study was performed to pre-dict the magnitude of weld residual stress and operating stress and compare it with previous experi-mental results for PWSCC initiation. For the study, a pressurizer safety nozzle was selected because it is reported to be vulnerable to PWSCC in overseas plants. The assessment was conducted by nu-merical analysis. Before performing stress analysis for plant conditions, a preliminary mock-up ana-lysis was done. The result of the preliminary analysis was validated by residual stress measurement in the mock-up. After verification of the analysis methodology, an analysis under plant conditions was conducted. The analysis results show that the stress level is not high enough to initiate PWSCC. If a plant is properly welded and operated, PWSCC is not likely to occur in the pressurizer safety nozzle.

아날로그 회로로 구현가능한 평균전류제어 저손실 bypass 전류센싱방법 (The Analog-circuited Low-loss Bypass Current Sensing Method for Average Current Mode Control)

  • 김석희;최병민;박종후;전희종
    • 전력전자학회논문지
    • /
    • 제19권2호
    • /
    • pp.133-138
    • /
    • 2014
  • This paper proposes a low power-loss averaging current mode control using a resistor and bypass switch. Generally, current sensing method using a resistor has a disadvantage of power loss which degrades the efficiency of the entire systems. On the other hand, proposed measurement technique operating with bypass-switch connected in parallel with sensing resistor can reduce power loss significantly the current sensor. An analog-circuited bypass driver is implemented and used along with an average-circuit mode controller. The bypass switch bypasses the sensing current with a small amount of power loss. In this paper, a 50[W] prototype average current mode boost converter has been implemented for the experimental verification.