• 제목/요약/키워드: Power Measurement

검색결과 4,645건 처리시간 0.032초

송풍기의 소음레벨 측정방법 (KS B6361, 2000년 개정내용을 중심으로) (Methods of A-weighted Sound Pressure Level Measurement for Fans and Blowers (KS B 6361, Focus on Revised Content made in 2000))

  • 김경호;이승배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.424-432
    • /
    • 2000
  • The revision was provided for the method of A-weighted sound pressure measurement for fans and blowers, in which the newly developed measurement techniques were applied to KS B 6361. This revision includes the sound power methods for radiated sound from the body, the in-duct measurement method, and the correction method for flow noise upon measuring microphone, etc.

  • PDF

Tone 방식을 사용한 위성 거리 측정에 대한 위성 링크 잡음의 영향 (Effect of satellite link noise for satellite range measurement using tone method)

  • 김영완
    • 대한전자공학회논문지TC
    • /
    • 제42권2호
    • /
    • pp.9-16
    • /
    • 2005
  • 톤 방식을 사용하는 위성 거리 측정 시스템의 위성 링크 잡음에 대한 열화도를 분석하였다. 상${\cdot}$하향 링크에서 발생되는 배경 잡음에 의하여 위성 거리 측정 위상 값에 열화가 발생되며, 열화도는 거리 측정 시스템의 루프 잡음 대역폭과 전송 모드신호에 의해 영향을 받는다. 분석된 잡음의 영향은 위성 잡음 환경에서 동작하는 거리 측정 시스템에서 측정된 열화도와 비교 분석하였다. RAU 전송 모드에서 위성 링크 신호의 신호대 잡음비$(C/N_o)$가 43 dB인 경우, 거리 측정 대역폭에 따라 약 $14.4\~40.6m$ 이내의 오차가 발생되었으며, 이론값에 비해서는 약 0.3 dB의 열화도가 발생하였다. 원격 측정 신호와 동시에 전송되는 모드에서는 RAU 전송 모드와 거의 동등한 성능을 보였으며, RAU 모드와 동일한 성능을 갖기 위해서는 RAU+TM 다중전송 모드에 따른 전력 손실 값으로 약 2.3 dB 증가된 위성 링크 신호의 신호대 잡음비가 요구되었다.

원자로 내부배럴집합체 상부면 측정위치 선정 (Selection of Measurement Locations at Inner Barrel Assembly Top Plate in the Reactor)

  • 고도영;김규형;김성환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.734-738
    • /
    • 2012
  • A comprehensive vibration assessment program for the Advanced Power Reactor 1400 reactor vessel internals is established in accordance with the United States Nuclear Regulatory Commission Regulatory Guide 1.20 Revision 3. This paper is related to instruments and measurement locations based on the vibration and stress response analysis results at the inner barrel assembly top plate in the reactor. The analysis results of the inner barrel assembly top plate in the reactor show that the deterministic stress and deformation due to the reactor coolant pump induced pressure pulsations are larger than the random stress and deformation induced by the flow turbulence. The selection of the instruments and measurement locations at Inner barrel assembly top plate in the reactor is essential requirements and very important study process for the vibration and stress measurement program in comprehensive vibration assessment program for the Advanced Power Reactor 1400 reactor vessel internals.

  • PDF

전력계통의 페이저 측정기 최적배치 (Optimal Placement of the Phasor Measurement Units in Power System)

  • 김재훈;조기선;김회철;신중린
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권7호
    • /
    • pp.313-322
    • /
    • 2000
  • This paper presents optimal placement of minimal set of Phasor Measurement Units (PMU's) and observability analysis of the network with PMU's. In order to find a observable system, a symbolic method which directly assigns an appropriate symbol for measurement or pseudo-measurement to every entry of node-branch incidence matrix is proposed. It is much simpler and easier to analyze the observability of the network with PMU's than the conventional ones. For the optimal PMU placement problem, two approaches which are based on a modified Simulated-Annealing (SA) method and a Direct Combination method are proposed. Some case studies with IEEE sample system are made to show the performance of the proposed methods are almost alike and more effective than the conventional simulated-annealing method. It is also shown that the Direct Combination method is more effective than the modified simulated-annealing one in the sense of computation burden. The results of this study showed also that the accuracy of power system estimation and system observability can be improved the proposed PMU placements.

  • PDF

전력케이블에서 교류전압과 진동파 전압을 이용한 부분방전 측정 (Partial Discharge Detection for the Power Cables using AC and Oscillating wave Voltage)

  • 김정태;김남준;이전선;구자윤
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권4호
    • /
    • pp.247-252
    • /
    • 1999
  • In this paper, in order to investigate availability of the OW-PD measurement method which has been proposed as an alternative of AC-PD measurement method to an after laying test and/or diagnosis for the power cable system, partial discharges owing to the needle-type defect integrated into the cable have been measured using AC and OW(Oscillating Wave) voltages. In the AC-PD measurement, the magnitude, phase and pulse number of partial discharges have been changed with the duration of voltage application, which can be analyzed through the relation with the process of the electrical tree initiation and propagation. In addition, the characteristics of partial discharges using OW voltage are appeared to be similar to those in case of AC-PD measurement and to be different with the shapes of electrical tree. From these results, it is concluded that the OW-PD measurement method is available to the tests for the cable system.

  • PDF

원전재료 모재 및 용접부 잔류응력측정 연구 (A Study of Residual Stress Measurement in the Weld of Nuclear Materials)

  • 이경수;이정근;이성호;박재학
    • 한국압력기기공학회 논문집
    • /
    • 제7권1호
    • /
    • pp.9-16
    • /
    • 2011
  • Primary water stress corrosion cracking (PWSCC) has been found in the weld region of the nuclear power plant. Welding can produce tensile residual stress. Tensile residual stress contributes to the initiation and growth of PWSCC. It is important to estimate weld residual stress accurately to predict or prevent the initiation and growth of PWSCC. This paper shows the results of finite element analysis and measurement experiment for weld residual stress. For the study, four kinds of specimen were fabricated with the materials used in the nuclear power plant. Residual stresses were measured by four kinds of methods of hole drilling, x-ray diffraction, instrumented indentation and sectioning. Through the study, numerical analysis and measurement results were compared and the characteristics of each measurement technique were observed.

직류전류측정기의 안전성 향상을 위한 고내구성 보호소자의 가용체 설계 (Design for a Fuse of High Durability Protection Elements for Improving the Safety of DC Current Measurement Device)

  • 이예지;윤재서;조성철;노성여
    • 한국전기전자재료학회논문지
    • /
    • 제33권3호
    • /
    • pp.201-207
    • /
    • 2020
  • With the expansion in the use of DC power systems and increased need for system maintenance, the development of measurement devices for maintenance requires high stability. Of the different kinds of DC current measurement devices, the single-shot measurement device causes the input signal of the current measuring unit to initially generate a high inrush current. The high inrush current flows into the signal processor of the meter, shortening the life of the internal fuses and causing failure. Therefore, in this study, the I2t value for increasing the durability of the fuse is designed using the available wire diameter. Operating characteristics for 210~400% over-current of the rated current, which is relatively low over-current, are realized by the plating of low melting tin metal. As a result, a method of designing a fuse element for a DC power supply, which improves the safety of the DC current measurement device by blocking the failure caused by the inrush current, is presented.

대기전력 측정을 통한 절전 잠재량 예측 (Potential Electrical Energy Saving by Stand-by Power Measurement)

  • 최재원;장우진
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.253-255
    • /
    • 1999
  • We measured stand-by power of electrical machinery and appliance which are used at office and house. And we estimated potential electrical energy saving through stand-by power and the expecting number of supplied apparatus. As a result, We can reduce electrical energy by minimizing a stand-by power consumption up to three billion kWh which are equal to about 1/3 of an atomic power plant's generating power of 1 year.

  • PDF