• 제목/요약/키워드: Power Measurement

검색결과 4,630건 처리시간 0.033초

Particle image velocimetry measurement of complex flow structures in the diffuser and spherical casing of a reactor coolant pump

  • Zhang, Yongchao;Yang, Minguan;Ni, Dan;Zhang, Ning;Gao, Bo
    • Nuclear Engineering and Technology
    • /
    • 제50권3호
    • /
    • pp.368-378
    • /
    • 2018
  • Understanding of turbulent flow in the reactor coolant pump (RCP) is a premise of the optimal design of the RCP. Flow structures in the RCP, in view of the specially devised spherical casing, are more complicated than those associated with conventional pumps. Hitherto, knowledge of the flow characteristics of the RCP has been far from sufficient. Research into the nonintrusive measurement of the internal flow of the RCP has rarely been reported. In the present study, flow measurement using particle image velocimetry is implemented to reveal flow features of the RCP model. Velocity and vorticity distributions in the diffuser and spherical casing are obtained. The results illuminate the complexity of the flows in the RCP. Near the lower end of the discharge nozzle, three-dimensional swirling flows and flow separation are evident. In the diffuser, the imparity of the velocity profile with respect to different axial cross sections is verified, and the velocity increases gradually from the shroud to the hub. In the casing, velocity distribution is nonuniform over the circumferential direction. Vortices shed consistently from the diffuser blade trailing edge. The experimental results lend sound support for the optimal design of the RCP and provide validation of relevant numerical algorithms.

DSP를 이용한 개선된 주파수 측정 알고리즘 구현 (Implementation of Advanced Frequency Measurement Algorithm)

  • 이정우;안종현;오용택
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2009년도 추계학술대회
    • /
    • pp.465-468
    • /
    • 2009
  • 전력 계통에서 계통 주파수는 부하의 변동에 따라 변화되어 연결된 발전기에 영향을 미치고 결국 계통에 커다란 지장을 초래한다. 그러므로 계통 주파수의 빠른 측정과 신속한 조속기 제어는 전력 계통의 안정성과 경제성에서 매우 중요한 부분이다. 과거의 전자기계식 주파수 계전기는 전력 소비가 크며 정확한 측정이 어려웠고, 이후 연구 개발된 디지틀 계전기는 노이즈와 왜곡의 영향을 많이 받으며, 최근에 개발된 Microprocessor 계전기는 고가의 장비에 50ms에서 수초정도의 주파수 측정시 시간상의 문제점을 가지고 있다. 본 연구에서는 주파수를 신속하고 정확하게 측정할 수 있는 개선된 알고리즘을 Matlab 프로그램에서 시뮬레이션하고 DSP6713 KIT에 프로그래밍하여 작동하였다. 임의의 전압파형을 DSP에 입력하고 동작시킴으로서 신속하게(약 30ms) 정확한 주파수를 측정하여 알고리즘의 효용성을 구현하였다.

  • PDF

APR1400 원자로 내부구조물 종합진동평가 측정센서 선정 (Selection of Measuring Sensors for Reactor Vessel Internals Comprehensive Vibration Assessment Program in Advanced Power Reactor 1400)

  • 고도영;이재곤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.433-438
    • /
    • 2010
  • Reactor vessel internals comprehensive vibration assessment program(RVI CVAP) is one of the necessary tests to ensure the safety of nuclear power plants. RVI CVAP of U.S. Nuclear Regulatory Commission Regulatory Guide 1.20(U.S. NRC R.G. 1.20) consists of the analysis, measurement, and inspection. One of the core technologies of the measurement program for RVI CVAP is to select suitable sensors. We analyzed RVI design data of Palo Verde nuclear generating station(U.S.) and Yonggwang nuclear generating station(Korea) and investigated measuring sensors used in both of them; moreover, we investigated sensors used for measurement of RVI CVAP for the last 20 years throughout the world. Based on these results, we selected the most suitable sensors for RVI CVAP in Advanced Power Reactor 1400(APR1400).

  • PDF

Measurement and Analysis of Loss in Optical Directional Couplers

  • Leepila, R.;Jangsilp, R.;Noppanakeepong, S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.484-487
    • /
    • 2004
  • Symmetric directional couplers are widely used in interferometers, switches, and various signal processing devices. Recently, several optical couplers using multimode fibers were reported, but these suffer from inefficient coupling of light into a branching fiber and/or low directivity. This paper presents the measurement and analysis of loss in the connection of optical fibers via the optical directional couplers. The functionality of the device is based on the principle that is symmetrical, the power in excited mode can be unambiguously directed into one of the output channel by varying and of its parameters. In this experiment, we measure the power of loss in the optical directional coupler at various radius of curvature. Before the measurement of loss in x-coupler, we polish the contact of the fiber surface in order that light can penetrate through another port. The results show that, when the radius of curvature is increased, the loss power is decreased and also approaches of the straight line case.

  • PDF

입력 전류의 측정이 필요없는 Boost 컨버터의 역률 보정에 관한 연구 (A Study On The Power Factor Correction Of The Boost Converter Without The Input Current Measurement)

  • 조상준;이광원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.376-378
    • /
    • 1996
  • This paper presents a new PFC control method which replaces a fast line current measurement with a filtered load current measurement. Using the power balance relation between the input and the output of the boost converter. the input current can be described as the function of load current. Thus the PWM signal which effects the switching control of the boost converter is generated using the PFC input voltage, the PFC output voltage and the load current as input variables. By using a filter between the bridge rectifier and a dc-to-dc converter, the input voltage of the dc-to-dc converter is forced to always maintain above zero volt. Then the input current traces a sinewave in phase. The proposed scheme accomplishes a very high power factor and a low harmonic distortion of the line current. The validity of this scheme is demonstrated through simulation.

  • PDF

피스톤계 마찰 측정 장치 개발 (Development of Piston Friction Force Measurement System)

  • 하경표;김중수;조명래;오대윤
    • 대한기계학회논문집A
    • /
    • 제26권8호
    • /
    • pp.1608-1614
    • /
    • 2002
  • This Paper presents a novel piston friction force measurement system that has characteristics of relieving the Pressure force acting on the upper surface of the liner; the system uses general rubber O-rings for combustion chamber sealing, and does not need special changes to the piston top land. The lower supporter of the floating liner increases stiffness in liner axial direction, and results in the increase of natural frequency. The upper supporter has multi-layer structure designed fer low axial stiffness and high radial stiffness. With the use of the present system, the effects of variation in clearance and piston ring tension were studied.

배전 계통의 고조파 측정 및 DB 구축에 대한 연구 (A study on the measurement of harmonics in the distribution system and the configuration of DB)

  • 박용업;강문호;조남훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.202-203
    • /
    • 2006
  • The equipment using the Power electronic device is recently increased in the distribution system, so power utility and customers increase in concerning about harmonics level. Accordingly, The power utility which prepares a measure for the harmonic public standard and manege process must analysis of the harmonics level and the effect on equipment interconnecting distribution system. In the past, the measurement equipment and technique is imperfect, so very difficult to investigate the harmonics and trend. But the improvement of the measurement equipment recently is possible to obtain the data realtime for harmonic analysis. In this paper, we research the measuring domestic harmonic and constructing of DB based on the IEC standard.

  • PDF

60W 출력을 가지는 반도체 소자의 직류 특성 측정시스템의 구현 (Implementation of the 60W DC Characteristic Measurement System for Semiconductor Devices)

  • 최인규;최창;한해진;박종식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.34-37
    • /
    • 2001
  • In this paper, we designed and implemented the 60W DC characteristic measurement system for semiconductor devices. The proposed system is composed of 2 SMU(Source and Measure Unit)s, 2 HPU(High power Unit)s, 2VSU(Voltage Source Unit)s, and 2 VMU(Voltage Measurement Unit)s. HPU can source/measure voltage from -200V to 200V and source/measure current from -3A to 3A within 60W. Experimental results show that the implemented system can measure the power devices such as power BJT, regulator IC, and voltage detector.

  • PDF

Estimation of Insulated-gate Bipolar Transistor Operating Temperature: Simulation and Experiment

  • Bahun, Ivan;Sunde, Viktor;Jakopovic, Zeljko
    • Journal of Power Electronics
    • /
    • 제13권4호
    • /
    • pp.729-736
    • /
    • 2013
  • Knowledge of a power semiconductor's operating temperature is important in circuit design and converter control. Designing appropriate circuitry that does not affect regular circuit operation during virtual junction temperature measurement at actual operating conditions is a demanding task for engineers. The proposed method enables virtual junction temperature estimation with a dedicated modified gate driver circuit based on real-time measurement of a semiconductor's quasi-threshold voltage. A simulation was conducted before the circuit was designed to verify the concept and to determine the basic properties and potential drawbacks of the proposed method.

회전 토크 교정장치 개발에 관한 연구 (Development of a Rotational Torque Calibration System)

  • 김갑순;권영하
    • 대한기계학회논문집
    • /
    • 제17권10호
    • /
    • pp.2646-2653
    • /
    • 1993
  • A rotational torque calibration system is developed to measure rotational torque of power generating systems and to calibrate non-contact rotational torque measurement systems. The maximum capacity of the developed system is 4.5 N-m. It is composed of a DC motor, a DC generator, a control system, a master torque cell, a slip ling/brush set, supporters, a bed etc. The control system is characterized by the closed-loop control with differential intergrator. Rotational torque measurement test and unit response test are conducted to estimate the accuracy of the developed system. It is found that system maintain high consistency and accuracy with the maximum error of 0.25%, Therefore the developed system can be used to measure the rotational torque of power generating systems and to calibrate non-contact rotational torque measurement systems.