• 제목/요약/키워드: Power Measurement

검색결과 4,630건 처리시간 0.03초

424 MHz 소출력 무선주파수 전파특성 측정 및 분석 (The Measurement and Analysis of Radio Characteristic of 424 MHz Short Range Wireless Frequency)

  • 임용훈;최효열;오규환;이범석;현덕화
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2005년도 종합학술발표회 논문집 Vol.15 No.1
    • /
    • pp.437-442
    • /
    • 2005
  • This paper deals with the measurement and analysis of radio characteristic of 424 MHz for using the automation of transmission and supply of electric power, ana automatic meter reading(AMR). Normally radio propagation characteristic is the base of system design, performance evaluation and choice of position of the base station in wireless communication. It is the most accurate way to design a base station through practical measurements, but it costs much time, money and engineers. So, we developed 424 MHz short range wave propagation model for AMR service.

  • PDF

부하 변동에 의한 전압불평형율의 특성 해석 (Analysis on the Characteristics of Voltage Unbalance Factor by Load Variations)

  • 김종겸;박영진;이은웅
    • 전기학회논문지P
    • /
    • 제54권1호
    • /
    • pp.47-53
    • /
    • 2005
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating voltage unbalance. Voltage unbalance factor is mainly affected by load system rather than stable power system. Unbalanced voltage will draw a highly unbalanced current. As a result, the three-phase currents may differ considerably, thus resulting in an increased temperature rise in the machine. This paper presents a scheme on the characteristics of voltage and current unbalance factor under the load variation at the three phase 4-wire system. Load unbalance factor is measured by the power quality measurement apparatus and compared by the current unbalance factor. Two methods are indicated similar results. The voltage unbalance factor of the three-phase 4-wire system is approved by the field measurement. Each phase has an impedance each other by the unbalanced operation pattern and give rise to voltage unbalance.

실물 실험을 통한 태양광 모듈의 표면온도와 태양광 발전량과의 관계에 대한 연구 (A Study on the Relationship Between Photovoltaic Module Surface Temperature and Photovoltaic Power Using Real Experiment)

  • 조성우
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권3호
    • /
    • pp.8-14
    • /
    • 2018
  • PV module power is calculated on PV module surface temperature adjustment by irradiation on the summer and autumn in NOCT(Nominal Operating Cell Temperature) conditions. The summer and autumn periods were selected because of large variation in outdoor air temperature and irradiation. This study was performed to understand relationship between PV module surface temperature and photovoltaic power using field measurement. As a results, it was determined that the amount of irradiation was proportional to the amount of photovoltaic power in the field measurement. However, it was also identified that the PV power generation decreased by increased PV module surface temperatures due to irradiation.

히트펌프 온수기 개발을 위한 계측 및 성능평가시스템 구축 (Development of Measurement and Performance Testing System for Heat Pump water Heater)

  • 권성철;양승권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2310-2312
    • /
    • 2004
  • In Korea Electric Power Corporation (or KEPCO), several Demand-Side Management (or DSM) program have been carried out to effectively meet electric power demand at least costs by modifying customers electricity use patterns. As one of them, KEPCO applies low-priced night thermal-storage power service for heat appliances to facilitate efficient use of power facilities by shifting relatively high daytime demands to night hours to build loads during the off-peak periods. In the market of heat-storage type water-heater, electric water-heater has been mostly used, but it has low energy efficiency and needs high capacity electric equipments. So in order to replace these electric water heaters, 15 HP air-source heat pump water heater is developed in Korea Electric Research Institute (or KEPRI). This paper shows that measurement system for performance testing of heat pump water heater is established and heating capacity and performance is analyzed and measured for out-door environmental change.

  • PDF

화력발전소 고온 증기배관 실시간 변위감시 시스템 개발 (Development of On-line Displacement Monitoring System for High Temperature Steam Pipe of Fossil Power Plant)

  • 이영신;현중섭
    • 한국정밀공학회지
    • /
    • 제22권6호
    • /
    • pp.83-89
    • /
    • 2005
  • Most domestic fossil power plants have exceeded 100,000 hours of operation with the severe operating condition. Among the critical components of fossil power plant, high temperature steam pipe systems have had a many problems and damage from unstable displacement behavior because of frequent start up and shut down. In order to prevent the serious damage and failure of the critical pipe system in fossil power plants, 3-dimensional displacement measurement system was developed for the on-line monitoring. Displacement measurement system was developed with a use of a LVDT type sensor and two rotary encoder type sensors. This system was installed and operated on the real power plant successfully.

pHEMT 전력 증폭기의 $IMD_3$ 비대칭성과 ACPR 특성 해석 (Analysis of Asymmetrical $IMD_3$ And ACPR Characteristics for pHEMT Power Amplifier)

  • 이강전;박찬혁;구경헌
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.221-224
    • /
    • 2005
  • This paper discribes the nonlinear distortion of a pHEMT power amplifier. In the paper, we have used some commercially available power amplifiers for analyzing the relationship between the $IMD_3$ and ACPR for wireless LAN. And the $IMD_3$ results using two-tone test have been compared with ACPR to satisfy the requited 802.11g standard ACPR value. Measurement result shows that $IMD_3$ of 20MHz tone-spacing need to be more than 18.45dBc for power amplifiers. The WCDMA signal is fed into the power amplifier, for analyzing relationship between the asymmetrical $IMD_3$ and ACLR. With measurement result, the asymmetrical $IMD_3$ characteristic has increased with the increase of two-tone spacing. $IMD_3$ measurement result with maximum 20MHz of the two-tone spacing, shows that the difference between $IMD_3(lower)$ and $IMD_3(upper)$ is about 7dB. And the measured ACLR shows 5dB difference at -4MHz and +4MHz offset from center frequency.

  • PDF

고출력 레이저광 측정을 위한 계측 장치 제작 및 성능 평가 (A development and evaluation of the high power laser measurement system)

  • 황대석;최종운;이영우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 춘계종합학술대회
    • /
    • pp.410-413
    • /
    • 2003
  • 고출력 레이저광 출력측정 및 교정을 위한 계측 장치를 제작하고 성능 평가에 관한 연구를 수행하였다. 계측 장치의 수광부는 금 코팅된 구리재질의 공동을 사용하여 제작되었다. 교정용 히터는 망가닌으로 제작되고, 출력 측정은 망가닌과 구리의 저항 브릿지를 사용하여 측정하였다. 외부 환경의 영향을 줄이기 위해 칼로리미터 내부의 온도를 5mK이하로 일정하게 하였다. 고출력 레이저 에너지의 측정을 위해 교정 인자와 보정 계수를 측정을 통하여 구하였다. 교정 인자는 100W 범위에서 489.13 J/mV 이고 500W 범위에서 497.04 J/mV이다. Nd:YAG Laser를 이용하여 보정 계수를 구한 결과 100W범위일 때는 0.99이고 500W범위일 때는 1.006으로 레이저 에너지와 전기적 교정의 차이는 1%이하이다.

  • PDF

Diagnosis of Medium Voltage Cables for Nuclear Power Plant

  • Ha, Che-Wung;Lee, Do Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1369-1374
    • /
    • 2014
  • Most accidents of medium-voltage cables installed in nuclear power plants result from the initial defect of internal insulators or the initial failure due to poor construction. However, as the service years of plants increase, the possibility of cable accidents is also rapidly increases. This is primarily caused by electric, mechanical, thermal, and radiation stresses. Recently, much attention is paid to the study of cable diagnoses. To date, partial discharge and Tan${\delta}$ measurements are known as reliable methods to diagnose the aging of medium-voltage cables. High frequency partial discharge measurement techniques have been widely used to diagnose cables in transmission and distribution systems. However, the on-line high frequency partial discharge technique has not been used in the nuclear power plants because of the plant shutdown risk, degraded measurement sensitivity, and application problems. In this paper, the partial discharge measurement with a portable device was tried to evaluate the integrity of the 4.16kV and 13.8kV cable lines. The test results show that the high detection sensitivity can be achieved by the high frequency partial discharge technique. The present technique is highly attractive to diagnose medium voltage cables in nuclear power plants.

광범위 출력 측정이 가능한 레이저 계측장치 개발 (Development of the laser measurement system for the wide output power range)

  • 황대석;이영우
    • 한국정보통신학회논문지
    • /
    • 제9권8호
    • /
    • pp.1799-1804
    • /
    • 2005
  • 넓은 출력 범위의 $CO_2$ 및 Nd:YAG 레이저광 출력측정 및 교정을 위해 정밀한 칼로리미터를 제작하고 성능의 정가에 관한 연구를 수행하였다. 칼로리미터의 수광부는 금 코팅된 구리재질의 공동을 사용하여 제작되었다. 교정용 히터는 망가닌으로 제작되고, 출력 측정은 망가닌과 구리의 저항 브릿지를 사용하여 측정하였다. 교정 인자는 100W에서 489.13 J/mV이고 500W에서 497.04J/mV이다 Nd:YAG Laser를 이용하여 보정 계수를 구한 결과 100W일 때는 0.99이고 500W일 때는 1.006으로 레이저 에너지와 전기적 교정의 차이는 $1\%$이하이다.

Real-Time Power Electronics Remote Wiring and Measurement Laboratory (PermLAB) Using 3-D Matrix Switching Algorithms

  • Asumadu, Johnson A.;Tanner, Ralph;Ogunley, Hakeem
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.611-620
    • /
    • 2010
  • This paper presents a new architecture, called "Power Electronics Remote Wiring and Measurement Laboratory (PermLAB)", that translates a common gateway interface (CGI) string from a remote web user to a web server connected to a 3-dimension switching matrix board, can be used to switch on and off, and to control a cluster of instruments and components. PermLAB addresses real-time connection, switching, and data acquisition over the Internet instead of using simulated data. A software procedure uses a signature system to identify each instrument and component in a complex system. The Web-server application is developed in HTML, JavaScript and Java, and in C language for the CGI interface, which resides in a controller portion of LabVIEW. The LabVIEW software fully integrates the Web sever, LabVIEW data acquisition boards and controllers, and the 3-dimensional switching matrix board. The paper will analyze a half-wave rectifier (AC - DC converter) circuit connected over the Internet using the PermLAB. PermLAB allows students to obtain real data by real-time wiring of real circuits in the laboratory using a "virtual breadboard" on the Web. The software for the Web-based 3-dimensional system is flexible, portable, can be integrated into many laboratory applications or expanded, and easily accessible worldwide.