• Title/Summary/Keyword: Power Measurement

Search Result 4,630, Processing Time 0.035 seconds

A Study On The Characteristics Of The Medium Voltage Power Distribution Line Channel By Wideband Channel Impulse Response Measurement Using PN Sequence (PN 시퀀스 방식의 광대역 임펄스 응답 측정을 통한 고압 배전선로 채널 특성 연구)

  • Oh Hui-Myoung;Choi Sung-Soo;Lee Jae-Jo;Kim Kwan-Ho;Whang Keum-Chan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.1
    • /
    • pp.56-60
    • /
    • 2005
  • In the power-line communication(PLC) systems, the power line is a wired medium. However, the power line channel has the multi-path fading characteristics like the wireless channel in the wireless communication systems because it has the signal reflection and divergence by the impedance mismatching between many branch lines and loads. So the analysis of the multi-path characteristics is very important, and it has been doing by the several measurement methods for the impulse response between the transmitter and the receiver. PN sequence method has originally been used as a wideband impulse response measurement mettled for wireless channel, but it is recently being applied to not only the wireless channel but also the wired channel like the power line channel. This method is more useful and effective for the long distance communication channel like the medium voltage power distribution line with the multi-paths[1]. In this thesis, we have measured impulse response for the medium voltage power distribution line channel by the wideband measurement method using PN sequence, analytically studied the measured data and presented the results.

Development of a Software System for Measurements of Combustion Dynamics of a Dry Low NOx Gas Turbine (건식 저 NOx 가스터빈의 연소동압 측정용 소프트웨어 시스템 개발)

  • Jang, Wook;Seo, Seok-Bin;Jung, Jae-Hwa;An, Dal-Hong;Kim, Jong-Jin;Cha, Dong-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.931-938
    • /
    • 2002
  • Combustion dynamics of a dry low NOx gas turbine have been measured by utilizing a dynamic pressure measurement system. The software part of the measurement system, implemented with a commercial general-purpose DASYLab version 5.6 code, basically acquires combustion dynamics signals, performs the FFT analysis, and displays the results. The gas turbine often experiences momentary combustion instability, especially when its combustion mode changes. It is found that the measurement system developed in the study may outperform the other commercial dynamic pressure measurement system. The developed system currently serves to monitor the combustion dynamics of the gas turbine.

An Operating Frequency Independent Energy Measurement Technique for High Speed Microprocessors

  • Thongnoo, Krerkchai;Changtong, Kusumal
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.2051-2054
    • /
    • 2004
  • This paper proposes a more accurate task level energy measurement technique for high speed microprocessors. The technique is based on the relationship of the amount of current consumed by the microprocessor and the pulse width of the power supply controller chip, employed in the synchronous buck DC-DC converter in the microprocessor's power supply. The accuracy of the measurement is accomplished by measuring variation in pulse width in each power supply cycle. The major advantage of this technique is that its accuracy does not depend on the operating frequency of the microprocessor. To prove the proposed technique, we implemented the measurement unit of the microprocessor energy meter using an FPGA chip operating at 50 MHz. Both static and dynamic load measurement are tested in order to obtain some behaviours. Moreover, various commercially available mainboards which employ synchronous buck regulators at 200 KHz switching frequency, were measured. The results agree with previous works with better accuracy at higher operating frequency.

  • PDF

Method and Application for Reliability Analysis of Measurement Data in Nuclear Power Plant (원전 배관의 두께 측정 데이터에 대한 신뢰도 분석 방법 및 적용)

  • Yun, Hun;Hwang, Kyeongmo;Lee, Hyoseoung;Moon, Seungjae
    • Corrosion Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.33-39
    • /
    • 2015
  • Pipe wall-thinning by flow-accelerated corrosion and various types of erosion is significant damage in secondary system piping of nuclear power plants(NPPs). All NPPs in Korea have management programs to ensure pipe integrity from degradation mechanisms. Ultrasonic test(UT) is widely used for pipe wall thickness measurement. Numerous UT measurements have been performed during scheduled outages. Wall-thinning rates are determined conservatively according to several evaluation methods developed by Electric Power Research Institute(EPRI). The issue of reliability caused by measurement error should be considered in the process of evaluation. The reliability analysis method was developed for single and multiple measurement data in the previous researches. This paper describes the application results of reliability analysis method to real measurement data during scheduled outage and proved its benefits.

Development of channel characteristics measurement system for Medium Voltage Power Line Grid (고압전력선 통신 채널 특성 측정 시스템 개발)

  • Lee, Jae-Jo;Lee, Won-Tae;Oh, Hui-Myoung;Kim, Kwan-Ho;Lee, Dae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2640-2642
    • /
    • 2002
  • In this paper, we show the channel characteristics measurement system the frequency range up to 30MHz for medium voltage Power Line Grid. Power line channel characteristics are investigated by means of various measurement instruments. Measurement system consists of medium voltage coupler, impedance measurement part, noise measurement part, voltage sensing part and communication part. Measured data will be used for PLC channel modeling and PLC network system design.

  • PDF

Adjustment Algorithm of Incident Light Power for Improving Performance of Laser Surface Roughness Measurement (레이저 표면 거칠기 측정 성능 향상을 위한 입사 광강도 조정 알고리즘)

  • 서영호;김화영;안중환
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.4
    • /
    • pp.79-87
    • /
    • 2004
  • The light pattern reflected from a machined surface contains some information like roughness and profile on the projected surface as expected in the Beckmann-Spizzichino model. In applying the theory into a real reliable measuring device, many parameters such as incident light power, wave length, spot size should be kept a constant optical value. However, the reflected light power is likely to change with the environmental noise, the variations of the light source, the reflectivity of the surface, etc. even though the incident light power is constant. In this study, a method for adjusting the incident light power to keep the reflected light power projected on a CMOS image sensor constant was proposed and a simple adjustment algorithm based on PI digital control was examined. Experiments verified that the proposed method made the surface roughness measurement better and more reliable even under variations of the height of light source.

Development of a Network Simulator for a Power Infrastructure Defense System Using IEEE PC37.118 (IEEE PC37.118을 이용한 광역 방어 시스템의 네트워크 시뮬레이터 개발)

  • Kim, Kyung-Nam;Yi, Keon-Young
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.173-174
    • /
    • 2006
  • The power infrastructure defense system monitor and control a power system with parameters of a power system such as voltage, phasor angle, frequency and power flow which are measured at the same instance. For this, synchronized phasor measurement based on the GPS(Global Positioning System) is necessary. PMU(Phasor Measurement Unit) measures synchrophasor and transmits it to the power infrastructure defense system. For this communication, IEEE H37.118 defines a communication message format and measurement concept and we extend the protocol to transmit disturbance data. The synchrophasor data can be sent at various rates and there are several options for phasor information sent in the synchrophasor message. In this paper, we develop software that simulate communication between the power infrastructure defense system and PMU to annalize the traffic.

  • PDF

Development of an Intelligent Power Plant Operating State Monitoring System (발전소 설비 운영상태 지능감시 시스템 개발)

  • Hong, Chang-Ho;Kim, Seok-Hyun;Lee, Seung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.1
    • /
    • pp.38-43
    • /
    • 2012
  • For safe and stable operations of power plants, it is essential to monitor closely crucial measurement values related to power plant trips. In this paper, an intelligent power plant operating state monitoring technique enabling the operating crew member to monitor conveniently the status of the important measurement values and to perceive almost instantly the significance of the implications of those measurement values is developed. The proposed technique is called a "POST(Plant Operating State Tracking) Chart" technique and provides the foundations in developing an intelligent and integrated power plant operating state monitoring support system called the "P-OASIS"(Plant Operation Assessment and Support Intelligent System). The P-OASIS is applied to a thermal power plant of 500[MW] capacity and exhibited impressive performances.

A Study on the Data Aquisition System for Power Quality Analysis of Load Equipment (부하설비의 전력품질 분석을 위한 데이터 획득시스템에 관한 연구)

  • Yu, Jae-Geun;Lee, Sang-Ik;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.92-94
    • /
    • 2007
  • In order to analyze voltage, current, electrical power, harmonics and so on of electrical load equipments, electrical power analysis by real measurement rather than mathematical modeling is necessary, and plan of countermeasure for efficient management, energy frugality and accident prevention of electrical equipments using it is possible. Especially, electrical power analysis by real measurement is indispensable in order to consider countermove of harmonic occurred by nonlinear load. So, in this paper, we developed DSP(Digital Signal Processor) based low price date aquisition system, and verified it's ability by performing measurement and analysis of electrical power and harmonic in the real power system.

  • PDF