• Title/Summary/Keyword: Power Measurement

Search Result 4,625, Processing Time 0.034 seconds

Comparison of Wave Power Resources in the Coastal Zone of the Korea East Sea Estimated by Using Field Measurement Wave Data (실측 파랑자료를 이용하여 추정된 우리나라 동해 연안역의 파력 부존량 비교)

  • Jeong, Weon-Mu;Oh, Sang-Ho;Lee, Dal-Soo;Lee, Dong-Young
    • New & Renewable Energy
    • /
    • v.3 no.3
    • /
    • pp.28-35
    • /
    • 2007
  • In this study, the wave power resources at the three locations [Sokcho, Hupo, and Onsan] on the east coast of Korea were estimated by using the field measurement data and were compared with the results of previous researches. It was found that seasonal variation of the wave power is very significant on the east coast of Korean peninsula. The wave power was the smallest in the summer season at all the locations. At Hupo and Onsan, the highest value of the monthly-averaged wave power was observed in September, probably because the pathways of typhoon in September were close to both locations. At the northest location, Sockcho, in contrast, the monthly highest value of the wave power appeared in January, probably owing to the influence of storm waves driven by Donghae twister. The estimated annual average wave power was 4.5 kW/m at Sokcho, which was about two times larger than those at other two locations. It is noteworthy that this result is completely different from past researches based on wave hindcasting data. In addition, the estimates of wave power by the past researches seemed to be smaller than those of the present study, especially at the northern region of the east coast.

  • PDF

A Study on Occupational Environment Assessment Strategies for Respirable Particulate Matter at Coal-Fired Power Plants (석탄화력발전소 호흡성분진 작업환경 평가 전략 사례에 관한 연구)

  • Eun-Seung Lee;Yun-Keun Lee;Dong-Il Shin
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.3
    • /
    • pp.375-383
    • /
    • 2023
  • Objectives: Coal-fired power plants feature diverse working conditions, including multi-layered employment structures and irregular work cycles due to outsourcing and non-standardized tasks. The current uniform occupational environment measurement systems have limitations in accurately assessing and evaluating these varied conditions. This study aims to propose alternative measurement and assessment strategies to supplement existing methods. Methods: Major domestic coal-fired power plants were selected as the study targets. To prepare for the study and establish strategies, work processes were identified and existing occupational environment measurement results were compared and analyzed. The study proceeded by employing three strategies: specific exposure groups (SEGs) measurement, continuous monitoring, and supplementary measurements, which were then compared and discussed. Results: Previous exposure index evaluations (5,268 cases) indicated that crystalline silica, a type of respirable particulate matter, had detection limits below the threshold (non-detectable) in 82.6% (4,349 cases) of instances. Exposures below 10% of the exposure limit were observed at a very low concentration of 96.1%. Similar exposure group measurements yielded results where detection limits were below the threshold in 38.2% of cases, and exposures below 10% of the limit were observed in 70.6%. Continuous monitoring indicated detection limits below the threshold in 12.6% of cases, and exposures below 10% of the limit were observed in 75.6%. Instances requiring active workplace management accounted for more than 30% of cases, with SEGs at 11.8% (four cases), showing a higher proportion compared to 3.0% (four cases) in continuous monitoring. For coal dust, exposures below 10% of the limit were highest in legal measurements at 90.2% (113 cases), followed by 74.0% (91 cases) in continuous monitoring, and 47.0% (16 cases) in SEGs. Instances exceeding 30% were most prevalent in SEGs at 14.7% (five cases), followed by legal measurements at 5.0% (eight cases), and continuous monitoring at 2.4% (three cases). When examining exposure levels through arithmetic means, crystalline silica was found to be 104.7% higher in SEGs at 0.0088 mg/m3 compared to 0.0043 mg/m3 in continuous monitoring. Coal dust measurements were highest in SEGs at 0.1247 mg/m3, followed by 0.1224 mg/m3 in legal measurements, and 0.0935 mg/m3 in continuous monitoring. Conclusions: Strategies involving SEGs measurement and continuous monitoring can enhance measurement reliability in environments with irregular work processes and frequent fluctuations in working conditions, as observed in coal-fired power plants. These strategies reduce the likelihood of omitting or underestimating processes and enhance measurement accuracy. In particular, a significant reduction in detection limits below the threshold for crystalline silica was observed. Supplementary measurements can identify worker exposure characteristics, uncover potential risks in blind spots of management, and provide a complementary method for legal measurements.

Noise Power Spectrum of Radiography Detectors: II. Measurement Based on the Spectrum Averaging (방사선 디텍터의 Noise Power Spectrum : II. Spectrum의 평균을 통한 측정)

  • Lee, Eunae;Kim, Dong Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.3
    • /
    • pp.63-69
    • /
    • 2017
  • In order to observe the noise property of the flat-panel digital radiography detector, measuring the normalized noise power spectrum (NNPS) from acquired x-ray images is conducted. However, the conventional NNPS measurement has an unstable property depending on the acquired image. Averaging the sample periodograms of the input image is usually performed to estimate the NNPS values and increasing the number of samples can provide a reliable NNPS measurement. In this paper, for a finite number of images, two measurement methods, which are based on averaging spectra, such as the image periodogram, are proposed and their performances are analyzed. Using x-ray images acquired from two types of radiography detectors, the two spectrum averaging methods are compared and it is shown that averaging spectra based on the maximal number of combinations of the image pairs provides the best performance in measuring NNPS.

Effect of Passive Temperature Therapy of the Femoral Muscles on the Countermovement Jump Performance

  • Lee, Jintaek;Panday, Siddhartha Bikram;Byun, Kyungseok;Lee, Jusung;Hwang, Jinny;Moon, Jeheon
    • Korean Journal of Applied Biomechanics
    • /
    • v.29 no.4
    • /
    • pp.227-235
    • /
    • 2019
  • Objective: The purpose of this study was to evaluate the effect of passive-acute temperature therapy of the femoral muscle and dynamic warm-up on the countermovement jump performance. Method: Twenty male track and field athletes from national team underwent three treatments applied on the femoral muscles; cold temperature treatment, thermal treatment and dynamic warm-up. The variables extracted at 2 time points (pre-measurement and post measurement) were the temperature of the left and right femoral muscle, displacement & velocity of centre of mass, peak power out, range of motion and moment & power of the knee joint. Results: There was a statistically significant difference in the temperature of the femoral muscle according to measurement time which was high in the order of thermal treatment, dynamic treatment and cold treatment. The jump height was the highest in the dynamic warm-up with no statistically significant difference for the range of motion of the knee joint. The peak power out at dynamic warm-up and the power of the knee joint were statistically significant according to the treatment and measurement time. Conclusion: Local cold and thermal treatment of femoral muscles at ambient temperature did not improve jump performance, while dynamic warm-up was considered to be effective for maintaining the performance of the activities that require strong muscular power.

Design of Wide-Band 6-Port Network for Noise Parameter Measurement Using 3-Section Wilkinson Power Divider and Slot-Coupled Directional Coupler (3단 윌킨슨 전력분배기와 Slot-Coupled 방향성 결합기를 활용한 잡음 파라미터 측정용 광대역 6-포트 회로망의 설계)

  • Lee, Dong-Hyun;Lee, Chang-Dae;Lee, Chan-Woo;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.2
    • /
    • pp.85-96
    • /
    • 2017
  • In this paper, a 2~18 GHz wideband 6-port network is designed and fabricated to extend the measurement frequency bandwidth of noise parameter measurement method using 6-port network. In order to design a broadband 6-port network, a wilkinson power divider and a directional coupler with wideband characteristics are designed. The wilkinson power divider is designed as a three-section structure to achieve wideband characteristics. The direction coupler is designed as a three-section structure and slot-coupled structure using multi-layer substrate to obtain wideband characteristics. A wideband 6-port network is designed and fabricated combining the designed power divider and coupler. The measured results of the fabricated 6-port network for the 2~18 GHz band show characteristics applicable to the noise parameter measurement method.

A Study on the Noise Measurement Method of Wind Power Facilities (풍력발전시설 소음 측정 방법에 대한 고찰)

  • YoungJin Lee;Jongtae Lee;Hyunkyung Min;Sunyong Kwon;Byungchan Lee
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.5
    • /
    • pp.279-290
    • /
    • 2023
  • Recently, as wind farms using wind power as new and renewable energy have been installed nationwide, noise problems have emerged. The environmental impact assessment and post-environmental impact assessment also require the measurement of background noise and low-frequency noise for wind farms, especially by applying the living noise measurement method according to the low-frequency noise management guidelines issued by the Ministry of Environment in 2018. Due to the nature of wind power generators that generate loud noise in high winds, noise measurement should be made at high winds, but when wind speed increases, wind noise increases and living noise and low-frequency noise are not properly evaluated. Therefore, the type of noise generated by wind power generators was confirmed, and matters to be considered when measuring wind noise such as wind noise were confirmed.

A Study on Structural Intensity Measurement of Semi-infinite Beam (반무한보의 진동 인텐시티 계측에 대한 연구)

  • 이덕영;박성태
    • Journal of KSNVE
    • /
    • v.7 no.1
    • /
    • pp.43-53
    • /
    • 1997
  • This paper investigated the practical use for measuring the structural intensity (power flow per width of cross section) in a uniform semi-infinite beam in flexural vibration. The structural intensity is obtained as a vector at a measurement point, One-dimensional structural intensity can be obtained from 4-point cross spectral measurement, or 2-point measurement on the assumption of far field. The measurement errors due to finite difference approximation and phase mismatch of accelerometers are examined. For precise measurements, it would be better to make the value of k$\delta$(wave number x space between accelerometers) between 0.5 and 1.0. Formulation of the relation between bending waves in structures and structural intensity makes it possible to separate the wave components by which one can get a state of the vibration field. Experimental results are obtained from 2- and 4-point measurement performed at 200mm (near field) and 400mm (far field) apart from excitation point in random excitation. the results are compared with the theoretical values and measured values of input power spectrum in order to verify the accuracy of structural intensity method, 2-point method is suggested as the practical structural intensity method.

  • PDF

Accuracy Improvement of Stereo-Based Distance Measurement for Close Range Vessel Positioning

  • Ogura, Tadashi;Mizuchi, Yoshiaki;Kim, Young-Bok;Choi, Yong-Woon
    • Journal of Power System Engineering
    • /
    • v.19 no.2
    • /
    • pp.27-32
    • /
    • 2015
  • This paper describes a distance measurement system with high accuracy that utilizes a stereo-based camera and a pan-tilt unit for automatically maintaining the positional relationship between a vessel and a target on the side of a facility at a close range. The measurement system offers an advantage in that it can measure the distance to a target while tracking it. In order to improve the ability to control the position of a vessel between it and a target while maintaining the distance especially at a close range, the accuracy of the measurement system has to be improved. The accuracy of the distance measured by our system is increased with revisions of the conclusively generated data of distance measurement. We verified the accuracy of our system from an experiment, which generated results that had an accuracy of 30 mm for distances in the range between 2-8 m.

Specific Heat and Thermal Conductivity Measurement of CNT/EEA Semiconducting Materials and XLPE Insulator (CNT/EEA 반도전층 재료와 XLPE 절연체의 열적 특성)

  • Yang, Jong-Seok;Lee, Kyoung-Yong;Shin, Dong-Hoon;Park, Dae-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.11
    • /
    • pp.514-519
    • /
    • 2006
  • To improve the mean-life and the reliability of power cable, we have investigated specific heat (Cp) and thermal conductivity of XLPE insulator and semiconducting materials in 154[kV] underground power transmission cable. Specimens were made of sheet form with the seven of specimens for measurement. Specific heat (Cp) and thermal conductivity were measured by DSC (Differential Scanning Calorimetry) and Nano Flash Diffusivity. Specific-heat measurement temperature ranges of XLPE insulator were from $20[^{\circ}C]\;to\;90[^{\circ}C]$, and the heating rate was $1[^{\circ}C/min]$. And the measurement temperatures of thermal conductivity were $25[^{\circ}C],\;55[^{\circ}C]\;and\;90[^{\circ}C]$. In case of semiconducting materials, the measurement temperature ranges of specific heat were from $20[^{\circ}C]\;to\;60[^{\circ}C]$, and the heating rate was $1[^{\circ}C/min]$. And the measurement temperatures of thermal conductivity were $25[^{\circ}C]\;and\;55[^{\circ}]C$. From these experimental results both specific heat and thermal conductivity were increased by heating rate because volume of materials was expanded according to rise in temperature. We could know that a small amount of CNT has a excellent thermal properties.