• 제목/요약/키워드: Power Manage System

검색결과 368건 처리시간 0.022초

Frequency divided group beamforming with sparse space-frequency code for above 6 GHz URLLC systems

  • Chanho Yoon;Woncheol Cho;Kapseok Chang;Young-Jo Ko
    • ETRI Journal
    • /
    • 제44권6호
    • /
    • pp.925-935
    • /
    • 2022
  • In this study, we propose a limited feedback-based frequency divided group beamforming with sparse space-frequency transmit diversity coded orthogonal frequency division multiplexing (OFDM) system for ultrareliable low latency communication (URLLC) scenario. The proposed scheme has several advantages over the traditional hybrid beamforming approach, including not requiring downlink channel state information for baseband precoding, supporting distributed multipoint transmission structures for diversity, and reducing beam sweeping latency with little uplink overhead. These are all positive aspects of physical layer characteristics intended for URLLC. It is suggested in the system to manage the multipoint transmission structure realized by distributed panels using a power allocation method based on cooperative game theory. Link-level simulations demonstrate that the proposed scheme offers reliability by achieving both higher diversity order and array gain in a nonline-of-sight channel of selectivity and limited spatial scattering.

THINNED PIPE MANAGEMENT PROGRAM OF KOREAN NUCLEAR POWER PLANTS

  • Lee, S.H.;Lee, Y.S.;Park, S.K.;Lee, J.G.
    • Corrosion Science and Technology
    • /
    • 제14권1호
    • /
    • pp.1-11
    • /
    • 2015
  • Local wall thinning and integrity degradation caused by several mechanisms, such as flow accelerated corrosion (FAC), cavitation, flashing and/or liquid drop impingements, are a main concern in carbon steel piping systems of nuclear power plant in terms of safety and operability. Thinned pipe management program (TPMP) had been developed and optimized to reduce the possibility of unplanned shutdown and/or power reduction due to pipe failure caused by wall thinning in the secondary side piping system. This program also consists of several technical elements such as prediction of wear rate for each component, prioritization of components for inspection, thickness measurement, calculation of actual wear and wear rate for each component. Decision making is associated with replacement or continuous service for thinned pipe components. Establishment of long-term strategy based on diagnosis of plant condition regarding overall wall thinning is also essential part of the program. Prediction models of wall thinning caused by FAC had been established for 24 operating nuclear plants. Long term strategies to manage the thinned pipe component were prepared and applied to each unit, which was reflecting plant specific design, operation, and inspection history, so that the structural integrity of piping system can be maintained. An alternative integrity assessment criterion and a computer program for thinned piping items were developed for the first time in the world, which was directly applicable to the secondary piping system of nuclear power plant. The thinned pipe management program is applied to all domestic nuclear power plants as a standard procedure form so that it contributes to preventing an accident caused by FAC.

Local-Generator-Based Virtual Power Plant Operation Algorithm Considering Operation Time

  • Park, Sung-Won;Park, Yong-Gi;Son, Sung-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2127-2137
    • /
    • 2017
  • A virtual power plant (VPP) is a system that virtually integrates power resources based on the VPP participating customer (VPC) unit and operates as a power plant. When VPP operators manage resources to maximize their benefits, load reduction instructions may focus on more responsive VPCs, or those producing high profitability, by using VPC resources with high operation efficiency. VPCs may thus encounter imbalance problems during operation. This imbalance in operation time would bring more participation for some VPCs, causing potential degradation of their resources. Such an operation strategy would be not preferable for VPP operators in managing the relationship with VPCs. This issue impedes both continual VPC participation and economical and reliable VPP operation in the long term. An operation algorithm is therefore proposed that considers the operation time of VPC generators for mandatory reduction of power resource consumption. The algorithm is based on constraints of daily and annual operation times when VPP operators of local generators perform capacity-market power transactions. The algorithm maximizes the operator benefit through VPP operations. The algorithm implements a penalty parameter for imbalances in operation times spent by VPC generators in fulfilling their obligations. An evaluation was conducted on VPP operational effects by applying the algorithm to the Korean power market.

국내 배전망 정책 및 환경변화를 고려한 배전부분 발전방향 연구 (KEPCO's Movement on Distribution Sector Regarding Renewable Energy Transition of Distribution Network in Korea)

  • Hyun, Seung-Yoon;Kim, Chang-Hwan;Lee, Byung-Sung
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제7권1호
    • /
    • pp.93-99
    • /
    • 2021
  • The government has proposed a mission to enhance intelligent power networks, decrease coal-fired generation, expand distributed energy resources, and promote energy prosumer into the distribution network in Korea. Installation cost of facility expansion to guaranteed interconnection with small distributed energy resources increases dramatically on KEPCO's distribution sector. And it is hard to withdraw in time. In addition, there are explicit research is required to meet the reliability on grid corresponding to the increase of distributed power. Infrastructure support for accommodating energy prosumer is also needed. Therefore, KEPCO is pushing transition to DSO by expanding distribution management scope and changing its roles. In addition, KEPCO is proactively preparing for integrated operation between distribution network and existing distributed power which is accommodated passively. KEPCO is also trying to accept multiple network users, e.g. building platforms, to manage a data and promote new markets. In the long term, transition to DSO will achieve saving investment costs for accommodating distributed sources and maintaining stable electrical quality. And it will be possible to create new business model using the platform to secure revenue.

초고압 가스절연개폐기의 베이 컨트롤러 개발 및 성능시험 (The Development and the Performance Test of Bay Controller for the High-Voltage Gas Insulated Switchgear)

  • 우천희;이보인
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.179-184
    • /
    • 2010
  • The digital substation automation system has contributed hugely to increasing the stability of power systems by providing not only protection and control of power systems but diagnostic features alongside them. Digital substation automation systems in the scale of substations consist of integrated operation systems and intelligent electronic devices. The main intelligent electronic devices currently in use are digital protection relays and the bay controllers in Gas insulated switchgears. Proficiently accomplishing the coordination of protection within the power system as a means of ensuring reliability and contriving for the stability of power supply through connection of function, the application of bay controllers is crucial, which collectively manage the protection relay at the bay level in order to achieve both. In this research, the bay controllers to be used in high-voltage Gas insulated switchgear has been localized, and in particular, the logic function and editor required in order to minimize the complicated hardware-like cable connections in the local panel have been developed. In addition, to ensure the strength and reliability of the bay controller hardware developed herein, the type tests from KERI have been successfully completed.

국내 특고압 고객에 대한 IEC 61000-3-7 기반의 플리커 방출한계 평가 및 관리 방안 연구 (Assessment and Management Method of Flicker Emission Level Based on IEC 61000-3-7 for Domestic Extra-high Voltage Customers)

  • 한수경;신훈철;박상호;김건중;조수환
    • 전기학회논문지
    • /
    • 제67권1호
    • /
    • pp.1-7
    • /
    • 2018
  • IEC 61000-3-7 provides guidance for limiting flicker and enabling the connection of fluctuating load installations, that is, producing flicker in MV, HV and EHV power systems. In Korea, the flicker have been restricted by Japanese standard of ${\Delta}V_{10}$ method. ${\Delta}V_{10}$ was developed only for arc furnaces in 1960's. And now it is revealed that it is not suitable for application to other fluctuating load installations through many researches. $P_{st}$ which is a flicker index used in IEC 61000-3-7, indicates visual inconvenience due to voltage fluctuation across large range of frequency and can be applied to fluctuating load installations as well as arc furnaces. In this paper, we introduce how to calculate and assess flicker emission level for the individual fluctuating load installations connected in EHV system and how to manage the emission levels in the power system according to IEC 61000-3-7.

Implementation of Under Voltage Load Shedding for Fault Induced Delayed Voltage Recovery Phenomenon Alleviation

  • Lee, Yun-Hwan;Park, Bo-Hyun;Oh, Seung-Chan;Lee, Byong-Jun;Shin, Jeong-Hoon;Kim, Tae-Kyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.406-414
    • /
    • 2014
  • Significant penetration of induction motor loads into residential neighborhood and commercial regions of local transmission systems at least partially determine a vulnerability to a fault induced delayed voltage recovery (FIDVR) event. Highly concentrated induction motor loads with constant torque could stall in response to low voltages associated with system faults. FIDVR is caused by wide spread stalling of small HVAC units (residential air conditioner) during transmission level faults. An under voltage load shedding scheme (UVLS) can be an effective component in a strategy to manage FIDVR risk and limit the any potential disturbance. Under Voltage Load Shedding take advantage of the plan to recovery the voltage of the system by shedding the load ways to alleviation FIDVR.

GIS 기반 신재생에너지 자원지도시스템 구축 (The Establishment of the GIS based Resource Map System for New and Renewable Energy)

  • 윤창열;김광득;정재혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.149-152
    • /
    • 2006
  • New and renewable energy information becomes one of the greatest issues because of serious environment problems and limited fossil resources However, There are few system to manage and utilize new and renewable energy information efficient. Therefore this study establish the GIS based Resource Map System to save and analyze new and renewable energy Informal ion about solar energy, wind power, small hydro, biomass, and geothermal. This Resource Map System is composed of the management system, practical system, field system and Web-service system. This System can Provide var ious spatial analysis tools such as data searching, treating thematic maps, evaluating location requirements for energy facilities.

  • PDF

GIS 기반 신재생에너지 자원지도시스템 구축 (The Establishment of the GIS based Resource Map System for New and Renewable Energy)

  • 윤창열;김광득;정재혁
    • 신재생에너지
    • /
    • 제2권4호
    • /
    • pp.27-32
    • /
    • 2006
  • New and renewable energy information becomes one of the greatest issues because of serious environment problems and limited fossil resources. However, There are few system to manage and utilize new and renewable energy information efficiently. Therefore this study establish the GIS based Resource Map System to save and analyze new and renewable energy information about solar energy, wind power, small hydro, biomass, and geothermal. This Resource Map System is composed of the management system, practical system, field system, and Web-service system. This System can provide various spatial analysis tools such as data searching, creating thematic maps, evaluating location requirements for energy facilities.

  • PDF

Development of Human Factors Engineering Program Plan (HFEPP) for MMIS Design of KNGR

  • Cha, Kyung-Ho;Park, Geun-Ok;Seo, Sang-Moon;Cheon, Se-Woo;Bong S. Sim
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(1)
    • /
    • pp.355-360
    • /
    • 1996
  • Human factors principles and evaluation methodologies are applied to design the MMIS of the KNGR. Human factors issues identified from the previous MMIS design of a nuclear power plant are considered in the development of the HFEPP. To manage human factors issues in the MMIS design of the KNGR, a conceptual Human Factors Issue Tracking System (HFITS) is also considered.

  • PDF