• 제목/요약/키워드: Power Line Communication System

검색결과 531건 처리시간 0.031초

전력선 통신을 이용한 plant 감시 제어 시스템 (Spread Spectrum Method based Power Line Communication for Plant Monitoring and Control System)

  • 서민상;성석경;안병규
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.211-215
    • /
    • 1997
  • Localized communication networks for office automation, security monitoring, environmental management of buildings, computer communications, and other applications enjoy every increasing demand. This paper proposes a direct sequence spread spectrum communication system for use in power line data transmission. Advantages of power distribution circuits include reasonably universal coverage and easy access vis a standard wall plug. Disadvantages include limited communication bandwidth, relatively high noise levels, and varying levels of impedance, noise, and attenuation. Spread spectrum signalling provides immunity to narrow-band signal impairments and multiplexing capability. Our prototype power line communication module supports completely physical and data link layers based on the international standard ISO 10368 for reliable high-speed power line communication system. Moreover it provides useful functions to compose a plant monitoring and control system. All the circuits of the communication module are included in one compact circuit. Thus a functional communication system for the power line plant monitoring and control is implemented.

  • PDF

전력선 통신과 공중 전화망에 의한 전력량의 원격 검침 시스템의 개발 (Development of the Remote Meter Reading System Using a Power Line Communication and PSTN)

  • 박종연;조호찬;최승지
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.103-106
    • /
    • 2002
  • This paper has studied a remote AMR(Automatic Meter Reading) system using the power line and the telephone line as a communication media and the digital power meter. In the developed system, because we have used the power line and telephone, the facility is very easy and then its cost is not expensive. The system includes following elements: a digital power meter, an indoor communication system using a power line modem and a telephone line interface system for sending data to the utility company.

  • PDF

PSCAD/EMTDC를 이용한 전력선통신 채널모델링 및 시뮬레이션에 관한 연구 (A Study of Channel Modeling and Simulation for Power Line Communication Systems using PSCAD/EMTDC)

  • 이종주;차재상;신명철
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권6호
    • /
    • pp.279-285
    • /
    • 2006
  • Power line communication channels are very complicated and models for communication channels vary with the types of electrical equipment, devices and load fluctuations. So, modeling and analysis of power line channels for implementation of power line communication systems is a very important process. Power line channel modeling and simulation are performed based on power system transient simulation models and power system CAD tools to create precise and accurate models. In this paper, a channel modeling and simulation method is proposed for power line communication systems using PSCAD/EMTDC, in which a PN 63 sequence code generator is applied for impulse response of the power line channel in the simulation model.

An Indoor Broadcasting System Using Light-Emitting Diode Lamps Coupled with Power Line

  • Lee, Seong-Ho
    • 센서학회지
    • /
    • 제24권5호
    • /
    • pp.342-347
    • /
    • 2015
  • We introduce an indoor broadcasting system using light-emitting diode (LED) lamps coupled with a 220 V power line. Two couplers connected to the power line constitute a power line communication (PLC) link. The transmission path from an LED lamp to a photodetector forms a visible light communication (VLC) link in free space. When the LED lamp is coupled to the power line, a composite PLC-VLC link is formed, making it possible to transmit a VLC signal beyond line-of-sight. In experiments, a 4 kHz analog signal modulated with a 100 kHz carrier was sent to the power line by a PLC coupler, and LED lamps coupled to the power line detected the signal and radiated it to multiple VLC receivers in the room. This configuration is useful in expanding an indoor VLC sensor network to adjacent rooms or constructing a voice broadcasting system in a building or apartments with existing power lines.

가스방전관(GDT)을 적용한 서지보호장치 회로의 DC 동작전압 최적조건 고찰 (Optimization of DC Operating Voltage for GDT-Adopted SPD)

  • 최종민;전태현
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.92-98
    • /
    • 2012
  • It is made compulsory to install SPD for the purpose of protecting electric and electronic devices when an abnormal voltage such as lightning occurs to power line using power frequency of 60Hz. Recently, the high speed communication technology utilizing power line is receiving attention again as a communication technology for smart grid. The SPD influences the performances of power line communication when using SPD and power line communication system together. In order to improve the performance of power line communication, a proposed scheme for series connection of gas discharge tube to ZnO varistor was presented. This paper measured the impacts of series connection of GDT to SPD using ZnO varistor on the limit voltage of Class III SPD. This paper also presented the DC operating voltage of GDT which satisfies the limit voltage of power line communication system and SPD simultaneously.

전력선 통신 시스템을 위한 머신러닝 기반의 원신호 예측 기법 (Machine Learning-Based Signal Prediction Method for Power Line Communication Systems)

  • 선영규;심이삭;홍승관;김진영
    • 한국위성정보통신학회논문지
    • /
    • 제12권3호
    • /
    • pp.74-79
    • /
    • 2017
  • 본 논문에서는 머신러닝 알고리즘 중 하나인 다층 퍼셉트론을 기반으로 전력선통신 시스템에서의 수신 신호를 이용하여 송신단에서 전송한 원신호를 예측하는 시스템 모델을 제안한다. 전력망을 활용한 통신 방식을 사용하는 전력선통신 시스템은 일반적인 통신설로를 활용하는 통신 방식에 비해 잡음이 많다. 이 때문에 전력선통신 시스템의 성능이 저하가 되는 문제가 발생한다. 이를 해결하기 위해 본 논문에서 제안하는 통신 시스템 모델을 이용하면 원신호 예측을 통해 잡음의 영향이 최소화되어 전력선통신 시스템의 성능저하를 완화시킨다. 본 논문에서는 제안한 통신 시스템 모델을 백색 잡음 환경에 적용하여 시뮬레이션을 해봄으로써 원신호가 예측 되는지를 입증한다.

A Signal Anti-reduction System for Power Line Communication

  • Ko Jong-Sun;Kim Hyun-Sik;Hong Soon-Chan
    • Journal of Power Electronics
    • /
    • 제4권4호
    • /
    • pp.256-260
    • /
    • 2004
  • A new communication system is suggested using a single-phase full-bridge inverter with high efficiency ferrite core for power line communication (PLC). The conventional system has a decreasing signal voltage problem due to internal resistance. The proposed system has almost zero internal impedance and replaces a linear amplifier.

전력선 통신 시스템을 위한 신호 감쇠 저하 장치 연구 (A Study on the Signal Anti-reduction Equipment in Power Line Communication)

  • 김주환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.103-106
    • /
    • 2000
  • In this paper a communication system that is not using the communication line but power line is presented. It will be very useful for an information-oriented society with tele-metering and home automation. Conventional system has a difficulty in transmitting information due to decreasing communication voltage and increasing carrier, current. Proposed idea is a special type switching amplifier system which has a low inner resistance. It can provide reactive power and dose not have low impedance between the transceivers. This new system is proposed to overcome the loss of conductor load in a PLC system.

  • PDF

전원동기를 이용한 스펙트럼 확산 전원선 통신장치의 구성 (Construction of Spread Spectrum Power Line Communication Equipment Using Power Line Synchronization)

  • 이동욱;변건식;김명기
    • 한국통신학회논문지
    • /
    • 제15권6호
    • /
    • pp.475-484
    • /
    • 1990
  • Direct Sequence 스펙트럼 확산방식에서 전원동기를 이용한 전원선 통신장치의 구성을 제안한 것이다. 전원선은 주파수대역폭이 일반적으로 10KHz~450KHz로 제한되어 있고, 특히 동기회로가 복잡해져서 제작가격이 높아지며 또한 시스템 규모가 커지며 다중통신하기가 어렵다. 동기회로를 이루기 위해서 교류전원에 동기하는 전원동기 Clock 발생회로를 제안하고 어드레스 설정기를 두어서 다중통신을 가능하게 하였다.

  • PDF

전력선 통신을 이용한 집단주택 안전관리 시스템 (Security Monitoring System for Apartment House Building Using Paver Line Carrier)

  • 김인수;김관호;김요희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.476-478
    • /
    • 1993
  • Instead of installing new communication wiring to each house in the apartment house building. the power distribution network. which is already installed in the building. can be use as communication medium. In a safty management, by adoption of power line communication system, at remote we can monitor safty related sensors such as fire, gas leakage, burglar intrusion and emergency call which are located at each house. From this viewpoint, we developed security monitoring system for apartment house building using power lines. Security monitoring system consists of Power Line Communication-Sub Controller (PLC-SC). Power Line Communication-Main Controller (PLC-MC) and Management System (MS). Between a PLC-MC and a PLC-SC, the transmission rate is 1200 bps in power lines and modulation technique is frequency shirt keying (FSK). In between a PLC-MC and a MS, the transmission rate is 1200 bps in communication line (RS-485). As a result of this research. transmission loss is 0.1dB per meter of intrabuilding distribution network. Transmission can be reach in 250 meters. So it is enough to communicate for security monitoring system in apartment house building.

  • PDF