• 제목/요약/키워드: Power Level

검색결과 7,407건 처리시간 0.03초

Analysis and Implementation of a New ZVS DC Converter for Medium Power Application

  • Lin, Bor-Ren;Shiau, Tung-Yuan
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1296-1308
    • /
    • 2014
  • This paper presents a new zero voltage switching (ZVS) converter for medium power and high input voltage applications. Three three-level pulse-width modulation (PWM) circuits with the same power switches are adopted to clamp the voltage stress of MOSFETs at $V_{in}/2$ and to achieve load current sharing. Thus, the current stresses and power ratings of transformers and power semiconductors at the secondary side are reduced. The resonant inductance and resonant capacitance are resonant at the transition interval such that active switches are turned on at ZVS within a wide range of input voltage and load condition. The series-connected transformers are adopted in each three-level circuit. Each transformer can work as an inductor to smooth the output current or a transformer to achieve the electric isolation and power transfer. Thus, no output inductor is needed at the secondary side. Three center-tapped rectifiers connected in parallel are used at the secondary side to achieve load current sharing. Compared with the conventional parallel three-level converters, the proposed converter has less switch counts. Finally, experiments based on a 1.44kW prototype are provided to verify the operation principle of proposed converter.

3-레벨 T-형 및 NPC 인버터의 전력 손실 비교 분석 (Comparative Analysis of Power Losses for Three-Level T-Type and NPC PWM Inverters)

  • 알레미파얌;이동춘
    • 전력전자학회논문지
    • /
    • 제19권2호
    • /
    • pp.173-183
    • /
    • 2014
  • In this paper, an analysis of power losses for the three-level T-type and neutral-point clamped (NPC) PWM inverters is presented, in which the conduction and switching losses of semiconductor devices of the inverters are taken into account. In the inverter operation, the conduction loss depends on the modulation index (MI) and power factor (PF), whereas the switching loss depends on the switching frequency. Power losses for the T-type and NPC inverters are analyzed and calculated at the different operating points of MI, PF and the switching frequency, in which the four different models of semiconductor devices are adopted. In the case of lower MI, the NPC-type is more efficient than the T-type, and vice versa. The validity of the power loss analysis has been verified by the simulation results.

멀티레벨 컨버터 기반 배전용 능동형 하이브리드 반도체 변압기에 대한 연구 (A Study on Multi-level Converter Based on Distribution Active Hybrid Solid State Transformer)

  • 윤춘기;조영훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.84-86
    • /
    • 2018
  • Active hybrid solid state transformer(AHSST) is newly emerging as a device to maintan the power quality of power distribution. AHSST has a simple structure in which a power electronics device is connected in series to a conventional distribution transformer. The connected power electronics device maintains the constant voltage regardless of the primary grid voltage fluctuation through the secondary voltage control to improve the power quality. It also has a simple structure compare to conventional solid state transformer system and can achieve the same performance with fractionally-rated converter. This paper proposes an multi-level converter based on AHSST system that has a simpler control method and wider voltage control range than the conventional AHSST. The proposed system is verified by simulations.

  • PDF

조력발전 운영을 위한 최대 발전량 산정 모델개발 (The Development of Model to Calculate Maximum Power for Tidal Power Plant Operation)

  • 오민환;김활수;김재훈;송규석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.505-508
    • /
    • 2006
  • Recently, concern for tidal power is being increased by newly recycled energy. It is important to decide on the maximum power estimate operation and it's stop by applying the difference of water level between tide level and artificial reservoir for the administration of tidal development. For maximum output of power through turbine generator, administrative variables and process on efficiency of hydraulic turbine and inflow discharge of reservoir is quite complicated because it is run through the connection of discharge-gate and turbine On the development of this model, the administrative process is decided, Operation block is presented for it's maximum power estimate.

  • PDF

Power Flow Control of Four Channel Resonant Step-Down Converters

  • Litvani, Lilla;Hamar, Janos
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1393-1402
    • /
    • 2019
  • This paper proposes a new power flow control method for soft-switched, four channel, five level resonant buck dc-dc converters. These converters have two input channels, which can be supplied from sources with identical or different voltages, and four output channels with arbitrary output voltages. They are specially designed to supply multilevel inverters. The design methodology for their power flow control has been developed considering a general case when the input voltages, output voltages and loads can be asymmetrical. A special emphasize is paid to the limitations and restrictions of operation. The theoretical studies are confirmed by numerical simulations and laboratory tests carried out at various operation points. Exploiting the advantages of the newly proposed power control strategy, the converter can supply five level inverters in dc microgrids, active filters, power factor correctors and electric drives. They can also play an interfacing role in renewable energy systems.

원자력 발전소 격납 건물의 수위 측정을 위한 열식 레벨 측정기 개발 (Development of Thermal Type Fluid Level Transmitter for Water Level Measurement of Containment Building in Nuclear Power Plant)

  • 윤준용;성낙원;이철호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.404-410
    • /
    • 2001
  • A new thermal type fluid level transmitter was designed and tested at the HITROL R&D institute. The relation of heat transfer and electric resistance was adopted as an operation principle. The length of a fabricated level transmitter was two meters and a water under normal temperature was used as a working fluid for the experiment Finally, the new product could have a high precision, acceptable accuracy and reasonable response time. Foreign-made level transmitter of this type is under in use for measuring water level of containment building in nuclear power plants so far. It is expected that new product will substitute it.

  • PDF

Modeling and Direct Power Control Method of Vienna Rectifiers Using the Sliding Mode Control Approach

  • Ma, Hui;Xie, Yunxiang;Sun, Biaoguang;Mo, Lingjun
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.190-201
    • /
    • 2015
  • This paper uses the switching function approach to present a simple state model of the Vienna-type rectifier. The approach introduces the relationship between the DC-link neutral point voltage and the AC side phase currents. A novel direct power control (DPC) strategy, which is based on the sliding mode control (SMC) for Vienna I rectifiers, is developed using the proposed power model in the stationary ${\alpha}-{\beta}$ reference frames. The SMC-based DPC methodology directly regulates instantaneous active and reactive powers without transforming to a synchronous rotating coordinate reference frame or a tracking phase angle of grid voltage. Moreover, the required rectifier control voltages are directly calculated by utilizing the non-linear SMC scheme. Theoretically, active and reactive power flows are controlled without ripple or cross coupling. Furthermore, the fixed-switching frequency is obtained by employing the simplified space vector modulation (SVM). SVM solves the complicated designing problem of the AC harmonic filter. The simplified SVM is based on the simplification of the space vector diagram of a three-level converter into that of a two-level converter. The dwelling time calculation and switching sequence selection are easily implemented like those in the conventional two-level rectifier. Replacing the current control loops with power control loops simplifies the system design and enhances the transient performance. The simulation models in MATLAB/Simulink and the digital signal processor-controlled 1.5 kW Vienna-type rectifier are used to verify the fast responses and robustness of the proposed control scheme.

신뢰도 측면에서 본 배전계통 최적투자 우선순위 결정 (Electric power distribution system most suitable investment precedence decision aspect of the reliability side)

  • 이희태;김재철;문종필;박현택;박창호;박상만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.384-386
    • /
    • 2003
  • Striking in change that present our country is much by electricity industry reform and the Korea Electric Power Corporation is deciding power distribution system reliability indices every year but power distribution system for reliability evaluation and establishment of investment program are consisting punily. If consider efficient inflection of resources and hereafter power distribution division that is limited for target achievement of schedule level service evaluation and reliability side in operation of the power distribution system, can expect efficient practical use of the power distribution property if gains in electrical side about these change and most suitable investment way consist because there is necessity of electric power plan establishment of area electric power distribution place of business unit. This paper consider proper reliability level and maximum effect through quantitative analysis to gain electrical gains of the power distribution system in reliability side depending on trend DB(Data Base) of data of electric power system composition appliance in this treatise and apply data administration and reliability rate analysis that serve to decide most suitable investment precedence to supply of electric power property to power distribution system present investment algorithm.

  • PDF

파워게이팅과 전압레벨조절을 이용하여 누설전류를 줄인 SRAM (A Low Leakage SRAM Using Power-Gating and Voltage-Level Control)

  • 양병도;천유소
    • 대한전자공학회논문지SD
    • /
    • 제49권8호
    • /
    • pp.10-15
    • /
    • 2012
  • 본 논문에서는 파워게이팅과 전압레벨조절을 이용하여 누설전류를 줄인 SRAM을 제안하였다. 제안된 파워게이팅 기법은 데이터를 저장하지 않은 메모리 셀 블록의 전력공급을 차단함으로써 누설전류를 크게 감소시키고, 제안된 전압레벨조절 기법은 데이터가 저장된 메모리 셀 블록의 접지전압을 올림으로써 누설전류를 줄여준다. $4K{\times}8$비트 SRAM 칩은 $0.13{\mu}m$ CMOS 공정으로 제작되었고 VDD=1.2V로 동작하였다. 메모리 사용률이 0~100%에 대하여, 동작 모드에서의 누설전류는 $1.23{\sim}9.87{\mu}W$이고 대기 모드에서 누설전류는 $1.23{\sim}3.01{\mu}W$였다. 대기 모드 동안에, 제안된 SRAM의 누설전류는 기존의 SRAM의 12.5~30.5%로 감소하였다.

원전 열화 전자카드의 입력신호 선택회로 개발 (Input Signal Selection Circuits Development of Electronic Cards for Thermal Degradation in Nuclear Power Plant)

  • 김종호;최규식
    • 한국항행학회논문지
    • /
    • 제23권6호
    • /
    • pp.554-560
    • /
    • 2019
  • 원전에서 각종 전자카드는 시간에 경과함에 따라 열화가 되므로 이에 대한 대책이 필요하다. 이 열화 카드들 중에서 노외중성자감시시스템의 카드들은 방사선원의 레벨에서 발생되는 중성자속을 총 원자로출력의 200%까지 연속적으로 감시하게 되는데, 원자로출력이 낮을 때의 경우와 높을 때의 경우의 출력감시신호처리 방법이 달라야 한다. 원자로 출력이 낮을 때는 대수적으로 발생되는 펄스신호를 선형적으로 계수하여 신호처처리를 해야 되지만, 원자로 출력이 커지게 되면 통계이론에 의한 방법으로 처리해야 정확한 값을 얻을 수 있기 때문이다. 이때 전자카드가 열화되는 것이 문제가 된다. 따라서, 본 연구에서는 저출력일 때와 고출력일 때의 신호처리 방법을 달리하여 일정한 기준에 의한 원자로의 출력레벨에서 이를 저출력에서 고출력으로 전환하기 위한 열화 입력선택회로를 개발하였다. 개발된 선택회로의 신뢰성을 확인하기 위하여 원전에서 사용되는 실제의 데이터값을 적용하여 테스트하였으며, 그 결과를 분석하여 선택회로의 정당성을 입증하였다.