• Title/Summary/Keyword: Power Factor

Search Result 6,145, Processing Time 0.039 seconds

Design of Active Power Factor Corrector for Low Power Supply by Loss Free Resistor Concept (무손실 저항개념을 이용한 저전력 전원설비용 능동 역률보정기의 설계)

  • 임영철;정영국;최찬학;나석환;이건식;장영학
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.1
    • /
    • pp.30-36
    • /
    • 1993
  • A simple discontinuous conduction mode(DCM) flyback type active power factor corrector for low power supply resents an effective resistive load to its power input. It is therefore well suited as an inexpensive high power factor rectifier for office equipment. An equivalent circuit model for the Active Power Factor Corrector based on the "Loss Free Resistor" concept is presented. This simple model correctly describes the basic power processing properties of the Active Power Factor Corrector, including input port resistor emulation, output port power some characteristics.teristics.

  • PDF

A Power Factor Analysis due to Interconnecting Photovoltaic Resource (계통연계형 태양광전원 투입에 따른 역률 분석)

  • Kim, Sang-Hyub;Rhee, Sang-Bong;Lyu, Seung-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.503-505
    • /
    • 2008
  • Photovoltaic(PV) resource connected in the power system can be affect to the power quality. To analyze the power quality, this paper simulate the variation of power factor by PV resource connected to the low voltage system. The power factor calculator and full-bridge inverter of PV system are modeled by EMTP/MODELS. Simulation results according to the PV capacity and load are presented.

  • PDF

Power Factor Correction Circuit For Inverter Air-Conditioner Using A Parallel Drive Method (병렬구동 방식을 이용한 인버터 에어컨용 역률제어회로)

  • 정용채;정윤철;권경안
    • Proceedings of the KIPE Conference
    • /
    • 1998.11a
    • /
    • pp.9-12
    • /
    • 1998
  • In this paper, the power factor correction circuit using a parallel drive method is proposed so that the high power inverter air-conditioner with 3[ph] compressor motor may obtain the cost down and the improved performance. The adequate design procedures are presented to reduce the material costs by eliminating the power factor improving LC filter and derating output capacitor and inverter switches. Using the determined components, the prototype circuit with 6[kW] power consumption is built and tested to verify the operation of the proposed circuit.

  • PDF

Control of a Three-Phase Voltage-Source PWM Converter with an Extended Operation Region (확장된 동작 영역을 갖는 3상 전압원 PWM 컨버터 제어)

  • 민동기;안성찬;현동석
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.9-13
    • /
    • 1997
  • In this paper, the operation regions of a three-phase voltage-source PWM converter are defined: linear modulation region, allowed current region, linear control region, unity power-factor region, and power-factor decreasing region. Particularly, the power-factor decreasing region is first examined and defined as the region where both the sinusoidal input current control and the stable DC link voltage regulation can not be obtained with a unity power-factor operation. To avoid these undesirable effects, the optimal current vector is derived, which ensures the sinusoidal input current and the stable DC link voltage regulation with maximum power-factor available, and, in consequence, it extends the operation region of the PWM converter. The validity of the proposed control scheme is proved by the computer simulation.

  • PDF

Fuzzy Power Factor Control Systems

  • Cho, Seong-Won;Kim, Jae-Min;Jung, Jae-Yoon;Lim, Cheol-Su
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.4 no.1
    • /
    • pp.45-49
    • /
    • 2004
  • A method for obtaining the power energy with high quality is to keep the power factor for a load as close to unity as feasible. In this paper, we present a new method to improve the power factor for a load. The proposed method uses fuzzy control techniques in order to determine how many parallel capacitors are to be connected to the load for the correction of the power factor.

Power Factor Correction of Single-phase Boost Converter for Low-cost Type UPS Configuration (저 가격형 UPS를 구성하기 위한 단상 부스트 컨버터의 고 역률 제어)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.3
    • /
    • pp.145-150
    • /
    • 2013
  • A novel AC to DC PWM converters with unity input power factor are proposed to overcome the above shortcoming. The main function of these converters is to shape the input line current to force it exactly in phase with the input AC voltage. Therefore, the input power factor can be improved to near unity and the input current harmonics can be eliminated. In this paper, half-bridge converter with two active switches and two diodes are utilized for low-cost type UPS configuration. By having only two semiconductors in the current path at any time, losses can be reduced over the conventional boost topology. Also, this converter provides controllable dc-link voltage, high power factor, and low cost type converter by simple power circuits. Simulation results show that the proposed half-bridge converter/inverter control technique can be applied to single-phase low-cost type UPS systems successfully.

Design of Zero Cross Detection Power Factor Correction IC (Zero Cross Detection Power Factor Correction IC 설계)

  • Seo, Kil-Soo;Kim, Hyoung-Woo;Kim, Ki-Hyun;Park, Hyeon-Il;Kim, Nam-Kyun;Park, Ju-Sung
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.519-520
    • /
    • 2008
  • In this paper, we design and implement the monolithic zero crossing detection power factor correction IC using a high voltage 30V BCD process. The ZCD PFC IC is designed for power applications, such as notebook, LCD monitor, etc. It includes power factor correction function and several protection circuit, regulator, high-voltage high current output drivers. And also, the designed IC has restart timer function which the output pulse is generated if the output signal of IC is not in a 200us. The simulation results show that the designed IC acts properly as power factor correction IC with efficient protective functions.

  • PDF

Analysis of Power Condenser Voltage Characteristics by Reactor Starting-operation (리액터 기동 운전시 콘덴서 전압 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong;Lee, Dong-Ju;Kim, Il-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.619-620
    • /
    • 2008
  • Reactor starting method has the advantage of simplicity and closed transition in spite of lower starting torque per kVA. This method allows a smooth start with almost no observable disturbance on transition and is suitable for applications such as centrifugal pumps or fans. Starting power factor is specially low. Power factor application is needed to compensate for the lower power factor of induction motor. This power factor compensation systems is being hit by the effects of the starting reactor connection position. This paper describes voltage and current stress affected by the installation position of power factor compensation application at the reactor starting method.

  • PDF

Novel High Power Factor Correction Circuit for Low-Cost Electronic Ballasts (저가격 형광등용 전자식 안정기에 적합한 새로운 역률개선회로)

  • Chae, Gyun;Youn, Yong-Sik;Cho, Gyu-Hyeong
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2072-2074
    • /
    • 1997
  • A new low-cost high power factor correction circuit for electronic ballasts is proposed. The proposed circuit provides good power factor correction, low current harmonic distortion and cost-effectiveness. The prototype meets the IEC555-2 requirements satisfactorily with nearly unity power factor.

  • PDF

Design and Implementation of PFC and THD Reduction System for CFL Mulitple Connection (다중접속 CFL용 PFC 및 THD 감소 시스템의 설계 및 구현)

  • 박종연;조호찬;최원호
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.67-70
    • /
    • 2002
  • In this paper, we have researched a Automatic Power Factor Correction and THD reduction System for the multiple connection of CFL. Also in this paper, the power factor has been researched for the design of CFL, found the reason why the power factor is low and THD is too high. This paper has designed the PFC System for the multiple connection of CFL, and then we have increased the power factor and reduced the total harmonic distortion, by implementing them.

  • PDF