• 제목/요약/키워드: Power Equipment Diagnosis

검색결과 183건 처리시간 0.025초

Remote Fault Diagnosis Method of Wind Power Generation Equipment Based on Internet of Things

  • Bing, Chen;Ding, Liu
    • Journal of Information Processing Systems
    • /
    • 제18권6호
    • /
    • pp.822-829
    • /
    • 2022
  • According to existing study into the remote fault diagnosis procedure, the current diagnostic approach has an imperfect decision model, which only supports communication in a close distance. An Internet of Things (IoT)-based remote fault diagnostic approach for wind power equipment is created to address this issue and expand the communication distance of fault diagnosis. Specifically, a decision model for active power coordination is built with the mechanical energy storage of power generation equipment with a remote diagnosis mode set by decision tree algorithms. These models help calculate the failure frequency of bearings in power generation equipment, summarize the characteristics of failure types and detect the operation status of wind power equipment through IoT. In addition, they can also generate the point inspection data and evaluate the equipment status. The findings demonstrate that the average communication distances of the designed remote diagnosis method and the other two remote diagnosis methods are 587.46 m, 435.61 m, and 454.32 m, respectively, indicating its application value.

전자파 검출에 의한 전력기기 On-Line 열화 측정시스템 개발 (Development of on-line system using electromagnetic wave for diagnosis of deteriorated power equipment)

  • 강창원;최길수;이영상;김창욱;강대수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1664-1666
    • /
    • 2001
  • This paper presents the development of electromagnetic wave detecting equipment for diagnosis of enclosed switchboard. High voltage power equipments are very important equipment of the key industries and the private enterprise. Power line accidents are national plans because of those set off casualties lose of power equipments and communication networks. Therefore the necessity of the development of detecting for power equipment diagnosis is demand for prevention of high voltage equipment accidents. This paper is the development of electromagnetic wave detecting equipment for diagnosis of high voltage equipment. This paper establishes the diagnosis method for high voltage power equipments, that secures original technique and possesses detecting technique for electromagnetic wave. By the study we developed electromagnetic wave detector, and we applied this equipment application tests at the place constructed high voltage equipments.

  • PDF

전자파를 이용한 폐쇄배전반내 전력기기의 열화 온라인 진단시스템 개발 (Development of on-line system using electromagnetic wave for diagnosis of deteriorated power equipment in enclosed switchboard)

  • 강창원;최길수;이영상;강대수;김재철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.178-181
    • /
    • 2001
  • This paper presents the development of electromagnetic wave detecting equipment for diagnosis of enclosed switchboard. High voltage power equipments are very important equipment of the key industries and the private enterprise. Power line accidents are national plans because of those set off casualties lose of power equipments and communication networks. Therefore the necessity of the development of detecting for power equipment diagnosis is demand for prevention of high voltage equipment accidents. This paper is the development of electromagnetic wave detecting equipment for diagnosis of high voltage equipment. This paper establishes the diagnosis method for high voltage power equipments, that secures original technique and possesses detecting technique for electromagnetic wave. By the study we developed electromagnetic wave detector, and we applied this equipment application tests at the place constructed high voltage equipments.

  • PDF

폐쇄 배전반에서의 부분 방전 On-Line 열화 감시 시스템 개발 (Development of electromagnetic wave detecting equipment for diagnosis of partial discharge in enclosed switchboard)

  • 전광호;강창원;김재철;김광화;강대수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.318-320
    • /
    • 2000
  • This paper presents the develop-ment of electromagnetic wave detecting equipment for diagnosis of enclosed switchboard. High voltage power equipments are very important equipment of the key industries and the private enterprise power line accidents are national plans because of those set off casualties lose of power equipments and communication networks. Therefore the necessity of the development of detecting for power equipment diagnosis is demand for prevention of high voltage equipment accidents. This paper is the development of electromagnetic wave detecting equipment for diagnosis of high voltage equipment. This paper establishes the diagnosis method for high voltage power equipments, that secures original technique and possesses detecting technique for electromagnetic wave. By the study we developed electromagnetic wave detector and we applied this equipment application tests at the place constructed high voltage equipments.

  • PDF

디지털 변전소 적용을 위한 초고압 GIS 부분방전 상태감시장치 개발 연구 (A study of Partial Discharge Condition Monitoring Equipment In the Ultra High Voltage Gas-Insulated Switchgear(GIS) for Digital Sub-station application)

  • 김영노;조용준;최철광;황철민;최재옥;강창원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1380-1381
    • /
    • 2008
  • By applying the digital sub-station, the change of various protect and measuring equipments has been applying. This paper is analyzed that the development of GIS partial discharge condition monitoring equipment is suited to the electricity IT technology and digital sub-station. It's constitution apply to be able to suit the data to high rank for GIS partial discharge condition monitoring equipment that is suited digital sub-station and Watch-dog module that be able to monitor the inner communication of the GIS partial discharge equipment. And then it also be able to apply of GIS partial discharge equipment when digital sub-station is applied.

  • PDF

GIS 설비 진단을 위한 포터블 부분방전 측정장치 개발 및 응용 (A Development of Measuring Instrument of Portable Partial Discharge for Diagnosis of GIS Installation and Application)

  • 김종서;김진태;신흥식;이홍재
    • 전기학회논문지P
    • /
    • 제58권2호
    • /
    • pp.231-234
    • /
    • 2009
  • Recently, to the development of a highly information-oriented society to a large increase in dependence on power, Accordingly, it is need that active development and spread of preservation technology on accident prevention in operation electrical equipment. However, to lack of the use on maintenance technology of power equipment and to increase of power usage is growing deterioration of power equipment, this is a cause on casualties, property damage and the occurrence of disasters is a growing. GIS equipments which are operated from domestic except the equipment which manages from the big business are depend on a most visual inspection, and do inspection method or measuring instrument etc. a condition which is not supplied widely. Currently, many to measure instrument used in domestic is very expensive or foreign, it will be able to substitute this, the development necessity of the diagnosis technique and the measuring instrument is demanded.

전력기기의 아크 플래시 진단 알고리즘에 관한 연구 (A Study on the Diagnostic Algorithm for Arc Flash of Power Equipment)

  • 이덕진
    • 한국전기전자재료학회논문지
    • /
    • 제29권7호
    • /
    • pp.449-453
    • /
    • 2016
  • The amount of electrical energy has been increased with the rapid development of the industrial society. Accordingly, operating voltage of the power equipment and facility capacity are continuously increasing. Development trends of recent high-voltage electrical equipment are ultra high-voltage, large-capacity and compact. Early diagnosis of a failure of the power plant has been emerging as an important task as to supply high quality power to users. In this study, we have tried to develope an algorithm for distinguishing an arc fault signal generated in the power plant by using UV sensor.

지중 배전케이블의 최적 교체기준 수립을 위한 열화진단 및 특성분석 (Aging Diagnosis and Characteristic Analysis of Distribution ,Power Cables I to Prepare Optimal Replacement Criterion)

  • 김주용;송일근;정익중;한명관;심유종;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권5호
    • /
    • pp.258-263
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this paper we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.

A New Support Vector Machine Model Based on Improved Imperialist Competitive Algorithm for Fault Diagnosis of Oil-immersed Transformers

  • Zhang, Yiyi;Wei, Hua;Liao, Ruijin;Wang, Youyuan;Yang, Lijun;Yan, Chunyu
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.830-839
    • /
    • 2017
  • Support vector machine (SVM) is introduced as an effective fault diagnosis technique based on dissolved gases analysis (DGA) for oil-immersed transformers with maximum generalization ability; however, the applicability of the SVM is highly affected due to the difficulty of selecting the SVM parameters appropriately. Therefore, a novel approach combing SVM with improved imperialist competitive algorithm (IICA) for fault diagnosis of oil-immersed transformers was proposed in the paper. The improved ICA, which is proved to be an effective optimization approach, is employed to optimize the parameters of SVM. Cross validation and normalizations were applied in the training processes of SVM and the trained SVM model with the optimized parameters was established for fault diagnosis of oil-immersed transformers. Three classification benchmark sets were studied based on particle swarm optimization SVM (PSOSVM) and IICASVM with four multiple classification schemes to select the best scheme for transformer fault diagnosis. The results show that the proposed model can obtain higher diagnosis accuracy than other methods. The comparisons confirm that the proposed model is an effective approach for classification problems.