• 제목/요약/키워드: Power Disturbance

검색결과 717건 처리시간 0.022초

비대칭외란을 고려한 2축 전동실린더의 동기제어에 관한 연구 (A Study on the Synchronous Control of Two Motor Cylinders with Skew Disturbance)

  • 변정환
    • 동력기계공학회지
    • /
    • 제13권6호
    • /
    • pp.129-136
    • /
    • 2009
  • A motor cylinder is widely used as an apparatus for transportation of a small scale load. It is, however, difficult for only one motor cylinder to transfer a large scale load such as a weir. The large scale load is transferred by two motor cylinders which are mounted on right and left of load itself. In this case, the displacement difference generated between two motor cylinders, namely, the synchronous error has a bad influence on the transportation. In this study, a synchronous control system is designed to restrain synchronous error caused by skew disturbance. The control system is composed of two disturbance observers and one synchronous controller. Each disturbance observer is designed to restrain the skew disturbance. And the synchronous controller is designed to achieve stable and accurate synchronization. Finally, the simulation results show that the designed control system is effective for the skew disturbance which lead to synchronous error.

  • PDF

Disturbance observer based adaptive sliding mode control for power tracking of PWRs

  • Hui, Jiuwu;Yuan, Jingqi
    • Nuclear Engineering and Technology
    • /
    • 제52권11호
    • /
    • pp.2522-2534
    • /
    • 2020
  • It is well known that the model of nuclear reactors features natural nonlinearity, and variable parameters during power tracking operation. In this paper, a disturbance observer-based adaptive sliding mode control (DOB-ASMC) strategy is proposed for power tracking of the pressurized-water reactor (PWR) in the presence of lumped disturbances. The nuclear reactor model is firstly established based on point-reactor kinetics equations with six delayed neutron groups. Then, a new sliding mode disturbance observer is designed to estimate the lumped disturbance, and its stability is discussed. On the basis of the developed DOB, an adaptive sliding mode control scheme is proposed, which is a combination of backstepping technique and integral sliding mode control approach. In addition, an adaptive law is introduced to enhance the robustness of a PWR with disturbances. The asymptotic stability of the overall control system is verified by Lyapunov stability theory. Simulation results are provided to demonstrate that the proposed DOB-ASMC strategy has better power tracking performance than conventional sliding mode controller and PID control method as well as conventional backstepping controller.

A New Excitation Control for Multimachine Power Systems II: Robustness and Disturbance Attenuation Analysis

  • Psillakis Haris E.;Alexandridis Antonio T.
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권spc2호
    • /
    • pp.288-295
    • /
    • 2005
  • In this paper a new adaptive, decentralized excitation control scheme proposed to enhance the transient stability of multimachine power systems is extensively analyzed with respect to its robustness and disturbance attenuation. As shown in the paper, both robustness and disturbance attenuation can be effectively improved by suitably selecting the design parameters of the proposed controller. Particularly, some simple rules for the selection of the control gains and the adaptation parameters are extracted which, as it is proven, may be essential for the system performance. Simulation tests on a two generator infinite bus power system absolutely confirm the theoretical results.

입력 급변 대응을 위한 철도 차량용 보조전원장치 외란 억제 알고리즘 구현 (Auxiliary Power Unit Control Algorithm for Input Voltage Disturbance Suppression)

  • 김지찬;백승길;차한주
    • 전기학회논문지
    • /
    • 제64권12호
    • /
    • pp.1810-1817
    • /
    • 2015
  • The railway vehicle has an auxiliary power unit for supplying power to the associated electronic control devices and passenger service unit. Typically, input voltage from the catenary for rolling stock is highly fluctuating according to the substation capacity, vehicle propulsion and regeneration. Especially, the frost and freezing on contact wire in winter can cause a blackout inside vehicle, and also brings about electronic components damaging and the system down. To prevent this problem, a large filter and capacitor is used. But this is not a perfect solution, because it is increasing weight of the unit. In this paper, a new algorithm is proposed to suppress the disturbance without adding devices. Simulation and experimental results show that the proposed algorithm has performance to suppress the disturbance at the sudden input voltage variations.

Power Quality Early Warning Based on Anomaly Detection

  • Gu, Wei;Bai, Jingjing;Yuan, Xiaodong;Zhang, Shuai;Wang, Yuankai
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1171-1181
    • /
    • 2014
  • Different power quality (PQ) disturbance sources can have major impacts on the power supply grid. This study proposes, for the first time, an early warning approach to identifying PQ problems and providing early warning prompts based on the monitored data of PQ disturbance sources. To establish a steady-state power quality early warning index system, the characteristics of PQ disturbance sources are analyzed and summed up. The higher order statistics anomaly detection (HOSAD) algorithm, based on skewness and kurtosis, and hierarchical power quality early warning flow, were then used to mine limit-exceeding and abnormal data and analyze their severity. Cases studies show that the proposed approach is effective and feasible, and that it is possible to provide timely power quality early warnings for limit-exceeding and abnormal data.

Robust Disturbance Compensation for Servo Drives Fed by a Matrix Converter

  • Park, Ki-Woo;Chwa, Dong-Kyoung;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제9권5호
    • /
    • pp.791-799
    • /
    • 2009
  • This paper presents a time-varying sinusoidal disturbance compensation method (based on an adaptive estimation scheme) for induction motor drives fed by a matrix converter. In previous disturbance accommodation methods, sinusoidal disturbances with unknown time-invariant frequencies have been considered. However, in the new method proposed here, disturbances with unknown time-varying frequencies are considered. The disturbances can be estimated by using a disturbance accommodating observer, and an additional control input is added to the induction machine drive. The stability analysis is carried out considering the disturbance estimation error and simulation results are shown to illustrate the performance of the proposed solution.

Recursive Design of Nonlinear Disturbance Attenuation Control for STATCOM

  • Liu Feng;Mei Shengwei;Lu Qiang;Goto Masno
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권spc2호
    • /
    • pp.262-269
    • /
    • 2005
  • In this paper, a nonlinear robust control approach is applied to design a controller for the Static Synchronous Compensator (STATCOM). A robust control dynamic model of STATCOM in a one-machine, infinite-bus system is established with consideration of the torque disturbance acting on the rotating shaft of the generator set and the disturbance to the output voltage of STATCOM. A novel recursive approach is utilized to construct the energy storage function of the system such that the solution to the disturbance attenuation control problem is acquired, which avoids the difficulty involved in solving the Hamilton-Jacobi-Issacs (HJI) inequality. Sequentially, the nonlinear disturbance attenuation control strategy of STATCOM is obtained. Simulation results demonstrate that STATCOM with the proposed controller can more effectively improve the voltage stability, damp the oscillation, and enhance the transient stability of power systems compared to the conventional PI+PSS controller.

외란관측기를 이용한 유압굴삭기 붐.아암 시스템의 궤적추적제어 (Trajectory Tracking Control of a Boom.Arm System of Hydraulic Excavator Using Disturbance Observer)

  • 조승호;안건형
    • 유공압시스템학회논문집
    • /
    • 제1권1호
    • /
    • pp.23-30
    • /
    • 2004
  • This paper deals with the issue of trajectory tracking control of a hydraulic excavator using disturbance observer in order to compensate external disturbances occuring from coupling between attachment, asymmetry of a single rod cylinder, and deadzone of main control valve. Disturbance compensation control system with disturbance observer has been constructed for the boom and arm respectively. Simulation results were compared with experimental results to validate the computer simulation system of hydraulic excavator itself. Computer simulation shows that disturbance compensation control is effective for compensating system nonlinearity and thus improves positioning accuracy and trajectory tracking performance. Steady state error has been decreased by adding PI controller to this control scheme.

  • PDF

DSP6416을 이용한 유도기의 정밀 위치 제어 (Precision position control of induction motors using DSP6416)

  • 김현식;김영찬;고종선
    • 전력전자학회논문지
    • /
    • 제12권1호
    • /
    • pp.19-26
    • /
    • 2007
  • 본 논문은 외란 변화에 대하여 정밀위치 변화를 줄이고자 외란 관측기를 사용하였고 이를 유도전동기에 적용하였다. 제안된 알고리즘이 외란 변화에 대한 유도전동기의 정밀 제어에 강인함을 보이고 있다. 외란 관측기가 있는 이 시스템은 높은 실효성과 외란 보상에 뛰어난 데드비트 컨트롤을 사용하고 있다. 이 효과를 보이기 위해서 모의 실험은 Simulink를 사용하였고 DSP6416 및 TCP-IP 네트워크 보드와 연동하여 실험하였다.

Power Quality Improvement for Grid Connected Inverters under Distorted and Unbalanced Grids

  • Kim, Hyun-Sou;Kim, Jung-Su;Kim, Kyeong-Hwa
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1578-1586
    • /
    • 2016
  • A power quality improvement scheme for grid connected inverters, even in the presence of the disturbances in grid voltages due to harmonic distortions and three-phase imbalance, is presented for distributed generation (DG) power systems. The control objective is to force the inverter currents to follow their references with robustness even under external disturbances in grid voltages. The proposed scheme is realized by a disturbance observer (DOB) based current control scheme. Since the uncertainty in a system can be effectively canceled out using an estimated disturbance by the DOB, the resultant system behaves like a closed-loop system consisting of a disturbance-free nominal model. For experimental verification, a 2 kVA laboratory prototype of a grid connected inverter has been built using a digital signal processor (DSP) TMS320F28335. Through comparative simulations and experimental results under grid disturbances such as harmonic distortion and imbalance, the effectiveness of the proposed DOB based current control scheme is demonstrated.