• Title/Summary/Keyword: Power Distribution Systems

Search Result 1,303, Processing Time 0.029 seconds

Research on the Effect of Interconnected Distributed Wind Power Generation(225[kV], AC Link Method) on Power Quality in System (연계형 풍력발전설비(225[kV], AC 링크방식)가 전력계통의 전원 품질에 미치는 영향에 관한 연구 분석)

  • Na, Chae-Dong;Park, Jung-Shin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.147-153
    • /
    • 2010
  • When small scale wind and solar power generation systems are connected to conventional power distribution system. It is worried that it can affect the quality of electricity such as voltage variation, power factor, frequency, harmonics and flicker. Therefore, in this research, in order to investigate the effects of wind power generation equipments(AC link method) on electrical power quality, when they are connected to distribution system. Power quality analyzer was installed respectively at the front side of power conversion system of conventional wind generation system and secondary side of consumer's power supply at distribution line. Measurements on power quality were performed and the effects of the wind generation system on distribution system were analyzed when it was and was not operated. The results show that 0.34[%] increase on voltage variation, 0.145 increase on current crest factor and 0.6[$^{\circ}$] deviation on phase difference when the power generation system was operated.

Design of beam steering dipole phased array antenna systems for IMT-2000 base station (IMT-2000 기지국용 빔 조향 다이폴 위상배열 안테나 시스템 설계)

  • 이상수;김명철;최학근
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.2
    • /
    • pp.41-51
    • /
    • 2004
  • In this paper, the beam steering dipole phased array antenna systems for IMT-2000 base station have been designed. The designed beam steering dipole phased array antenna systems are constituted by the antenna part and the beam steering control system part. The antenna part is designed by the proposed flat dipole for the broadband characteristics, and the 8${\times}$8 dipole array antenna is constructed by the proposed flat dipole for the directional radiation pattern. Besides the vertical power divider is designed for the vertical power distribution. The beam steering control system part is designed the horizontal power divider for the horizontal power distribution, the 4-bit phase shifters and the driving circuit of phase shifters for the horizontal beam tilting. In order to evaluate a performance of the designed antenna systems, they were fabricated and the radiation characteristics were measured. From the measured results, we found that the horizontal beams were tilted by the each control signals, and the measured radiation characteristics showed good agreement with the design goals.

Research on Backup Protective Coordination for Distribution Network (네트워크 배전계통용 백업 보호협조에 관한 연구)

  • Kim, WooHyun;Chae, WooKyu;Hwang, SungWook;Kim, JuYong
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.15-19
    • /
    • 2022
  • The radial distribution systems (RDS) commonly used around the world has the following disadvantages. First, when the DL is operated on a radial system, the line utilization rate is usually kept low. Second, if a fault occurs in the radial DL, a power outage of 3 to 5 minutes is occurring depending on the operator's proficiency and fault situation until the fault section is separated and the normal section is replaced. To solve this problem, Various methods have been proposed at domestic and foreign to solve this problem, and in Korea, research is underway on the advanced system of operating multiple linked DL always. A system that is electrically linked always, and that is built to enable high-speed communication during the protection coordination is named networked distribution system (NDS). Because the load shares the DL, the line utilization rate can be improved, and even if the line faults, the normal section does not need to be cut off, so the normal section does not experience a power outage. However, since it is impossible to predict in which direction the fault current will flow when a failure occurs in the NDS, a communication-based protection coordination is used, but there is no backup protection coordination method in case of communication failure. Therefore, in this paper, we propose a protective cooperation method to apply as a backup method when communication fails in NDS. The new method is to change TCC by location of CB using voltage drop in case of fault.

Design of a Photovoltaic PCS with Compensation Control of Reactive Power and Unbalance Current in Three-phase systems (3상 시스템의 무효전력, 불평형 전류 보상 기능을 갖는 태양광 전력변환장치 설계)

  • Park, Sang-Min;Kim, Chang-Soon;Le, Dinh Vuong;Park, Minwon;Yu, In-Keun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.21 no.3
    • /
    • pp.29-33
    • /
    • 2016
  • Development of the distributed energy resources such as photovoltaic, wind, and fuel cell has increased rapidly due to the rising demand for clean energy utilization. On the other hand, the distribution system became complex and has problems such as degradation of power factor and current unbalance caused by power converters, reactive power and unbalanced loads. To solve these problems, this paper proposes a 3-phase 4-leg type power conditioning system with compensation control algorithm for the reactive power and unbalance current in distribution system using photovoltaic resource. It is simulated in PSCAD/EMTDC and the effectiveness is confirmed.

Network Betweenness Centrality and Passenger Flow Analysis of Seoul Metropolitan Subway Lines (서울 수도권 지하철망의 호선별 망 매개 중심성과 승객 흐름 분석)

  • Lee, Kang Won;Lee, Jung Won
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.2
    • /
    • pp.95-104
    • /
    • 2018
  • Using network betweenness centrality we attempt to analyze the characteristics of Seoul metropolitan subway lines. Betweenness centrality highlights the importance of a node as a transfer point between any pairs of nodes. This 'transfer' characteristic is obviously of paramount importance in transit systems. For betweenness centrality, both traditional betweenness centrality measure and weighted betweenness centrality measure which uses monthly passenger flow amount between two stations are used. By comparing traditional and weighted betweenness centrality measures of lines characteristics of passenger flow can be identified. We also investigated factors which affect betweenness centrality. It is the number of passenger who get on or get off that significantly affects betweenness centrality measures. Through correlation analysis of the number of passenger and betweenness centrality, it is found out that Seoul metropolitan subway system is well designed in terms of regional distribution of population. Four measures are proposed which represent the passenger flow characteristics. It is shown they do not follow Power-law distribution, which means passenger flow is relatively evenly distributed among stations. It has been shown that the passenger flow characteristics of subway networks in other foreign cities such as Beijing, Boston and San Franciso do follow power-law distribution, that is, pretty much biased passenger flow traffic characteristics. In this study we have also tried to answer why passenger traffic flow of Seoul metropolitan subway network is more homogeneous compared to that of Beijing.

Optimal load distribution for two cooperating robot arms using force ellipsoid

  • Choi, Myoung-Hwan;Cho, Hye-Kyung;Lee, Bum-Hee;Ko, Myoung-Sam
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1790-1795
    • /
    • 1991
  • The optimal load distribution for two cooperating robots is studied in this paper, and a new solution approach utilizing force ellipsoid is proposed. The load distribution problem is formulated as a nonlinear optimization problem with a quadratic cost function. The limit on instantaneous power is considered in the problem formulation as the joint torque constraints. The optimal solution minimizing energy consumption is obtained using the concept of force ellipsoid and the nonlinear optimization theory. The force ellipsoid provides a useful geometrical insight into the load distribution problem. Despite the presence of the joint torque constraints, the optimal solution is obtained almost as a closed form, in which the joint torques are given in terms of a single scalar parameter that can be obtained numerically by solving a scalar equation.

  • PDF

Overvoltage Protection Controller Design of Distributed Generation Connected to Power Grid Considering Islanding Condition

  • Cha, Jae-Hun;Park, Kyung-Won;Ahn, Hong-Seon;Kwon, Kyoung-Min;Oh, Jin-Hong;MAHIRANE, Philemon;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.599-607
    • /
    • 2018
  • Distributed generation (DG) is being highlighted as an alternative for future power supplies, and the number of DG systems connected to conventional power systems is steadily increasing. DG generators are designed using power electronics and can give rise to various power quality problems, such as overvoltage or overcurrent. Particularly, unintentional islanding operation can occur in a conventional power system when the power grid is separated from the DG systems. Overvoltage may occur in this situation, depending on the power generation and power consumption. However, overvoltage phenomena might not happen even when islanding occurs. Therefore, it is necessary to analyze the fault characteristics during islanding. In this study, a fault analysis of islanding operation was carried out using PSCAD/EMTDC, and a countermeasure for the overvoltage problem is proposed.

A Study on the Effects of Lightning Arrestors Installment on a 154kV Transmission System (154kV 송전선로용 피뢰기 현장 설치 효과 분석)

  • Choi, Han-Yeol;Gu, Sung-Wan;Min, Byeong-Wook;Park, Soon-Kyu;Lee, Bong-Hee;Kwak, Joo-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.184-189
    • /
    • 2009
  • Lightning has been identified as one of the leading causes of outages on transmission and distribution systems. As sensitive loads and reliance on electric power increase year by year, it is getting more focus on stable and high quality of power supply. To protect the transmission and distribution line from lightning, the transmission lightning arrester can be the effective facility on the power system. This paper discusses Gapped type Arresters application results by analysing effects of lightning arresters on transmission and distribution line.

A Study on Application of RCM Method to Power Distribution System using Ordinal Optimization (Ordinal Optimization을 이용한 배전계통에 RCM 적용기법에 관한 연구)

  • Moon, Jong-Fil;Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.2
    • /
    • pp.67-73
    • /
    • 2012
  • This paper proposes optimal maintenance strategies for power distribution systems that involve the use of the reliability-centered maintenance (RCM) method. We developed an improved decision model based on the Markov process. This model can obtain the optimal inspection interval and maintenance method based on the total expected cost. We used ordinal optimization for solving the optimal problem. Optimal maintenance strategies were presented by applying the developed method to the RBTS model. A B/C analysis proved that these strategies offer maximum benefit-to-cost.

Development of the digital protection relay for protecting distributed generation (분산전원 보호용 디지털 보호계전기 개발)

  • Cho, Chul-Hee;Lee, Byeong-Ho;Oh, Eui-Seok;Ko, Chul-Jin;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.181-183
    • /
    • 2005
  • The existing distribution networks are growing with an increase of power demand more and more. Therefore, for efficient operation of distribution networks, operators are much in need of distributed generation. This paper describes a development of the digital protection relay(HIMAP) for protecting distributed generation which is expected to play an increasing role in electric power systems in the near future. This paper particularly introduces frequency protective algorithm and reverse power protective algorithm among the relaying algorithms for protecting distributed generation in distribution networks and resents capability of a developed digital protection relay including these algorithms.

  • PDF