• Title/Summary/Keyword: Power Diagram

Search Result 374, Processing Time 0.031 seconds

Non-Linear Model of Voltage Source Power Converter and Tuning Current controller (전압형 전력 변환기 비선형 모델 및 전류제어기 조정)

  • Park, Sang-Young
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.144-146
    • /
    • 1998
  • In this study Dead time equivalent resistance of Voltage source power converter is very important in current controller design. And Non-linear Modeling method can be applied in Power converter analysis. Using Describing Function method and Non-linear Resistance Modeling. Voltage Source Power Converter Bode diagram and Current controller analysis method are more reality.

  • PDF

A SD approach to the Efficiency Improvement of Electric Power Industry in Korea -Focused on the Nuclear Industry (국내 전력산업의 효율성 제고모형에 대한 SD 모형 연구 - 원자력산업을 중심으로)

  • Heo, Hoon;Lee, Myung-Ho
    • Korean System Dynamics Review
    • /
    • v.4 no.2
    • /
    • pp.153-171
    • /
    • 2003
  • In this study, we tried to build a model which can deal with the efficient and effective operation of electric power industry, especially focused on the nuclear industry. Here, SD(system Dynamics) approach is used to visualize the underlying phenomenon of the nuclear power industry. SD is a methodology for studying and managing complex feedback systems, such as one finds in business and other social systems, The span of SD applications has grown extensively and now encompasses work in corporate planning and policy design, public management and policy, biological and medical modeling, energy and the environment. Recently, according to the report from KEPCO(Korea Electric Power Corporation), they are considering delaying a new power plant construction. It may be based upon business fluctuation downsized from Korean economic crisis in 1997 and freezing of construction funds due to unstable foreign exchange rate. At this point, we need desperately a kind of strategic model that would contribute to cope with the current business situation, energy generation, Production, and resulting Pollution. Specifically, this model, using SD approach, starts with the detailed drawing of influence diagram, which describes those relevant key points on nuclear power generation systems in electric power industry of Korea. These include such (actors as the operation of nuclear industry and parameters related to the decision making for business policy. Based upon the above-mentioned influence diagram drawn, we developed SD simulation model to evaluate and analyze strategic management of KBPCO. Based on our analysis, we could demonstrate how simulation model can be applied to the real electric power generation in Korea.

  • PDF

A SD approach to the Efficiency Improvement of Electric Power Industry in Korea: Focused on the Nuclear Industry (시스템 다이내믹스(SD)에 의한 국내 전력산업의 효율성 제고에 관한 연구: 원자력산업을 중심으로)

  • Lee, Myoung-Ho;Lee, Hee-Sang;Jang, In-Sung;Choi, Bong-Sik;Huh, Hoon
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.26 no.2
    • /
    • pp.99-109
    • /
    • 2001
  • In this study, we tried to build a model which can deal with the efficient and effective operation of electric power industry, especially focused on the nuclear industry. Here, SD (System Dynamics) approach is used to visualize the underlying phenomenon of the nuclear power industry. SD is a methodology for studying and managing complex feedback systems, such as one finds in business and other social systems. The spend of SD applications has grown extensively and now encompasses work in corporate planning and policy design, public management and policy, biological and medical modeling, energy and the environment. Recently, according to the report from KEPCO (Korea Electric Power Corporation), they are considering delaying a new power plant construction. It may be based upon business fluctuation downsized from Korean economic crisis in 1997 and freezing of construction funds due to unstable foreign exchange rate. At this point, we need disparately a kind of strategic model that would contribute to cope with the current business situation, energy generation, production, and resulting pollution. Specifically, this model, using SD approach, starts with the detailed drawing of influence diagram, which describes those relevant key points on nuclear power generation systems in electric power industry of Korea. These include such factors as the operation of nuclear industry and parameters related to the decision making for business policy. Based upon the above-mentioned influence diagram drawn, we developed SD simulation model to evaluate and analyze strategic management of KEPCO. Based on our analysis, we could demonstrate how simulation model can be applied to the real electric power generation in Korea.

  • PDF

The Development of Virtual Power Plant Simulator for Operator Training using Soft Panel (소프트패널을 이용한 발전소 운전원 훈련용 가상 시뮬레이터 개발)

  • Park Shin-Yeol
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.150-153
    • /
    • 2003
  • 한전 전력연구원은 기준 발전소 시뮬레이터가 없는 고리1호기 원자력발전소의 현황을 고려하여 주제 어실은 없지만 고리1호기의 운전특성을 나타내는 전범위 시뮬레이터개발의 1단계로서 강사 및 운전원 모니터에 나타나는 Soft Panel 만으로 운전훈련이 가능 하도록 하는데 목표를 두고 원자력발전소 운 전원 훈련용 시뮬레이터를 개발 하였다. 본 논문에서는 상기의 개발내용 중에서 시뮬레이션 시스템 구성, 컴퓨터별 주요기능, 강사제어 프로그램, 운전원제어 프로그램, Simulation Diagram 화면, Soft Panel 화면, 시뮬레이터 연동 등에 대한 내용을 기술하고자 한다.

  • PDF

Effects of Wire speed Fluctuation on Arc Stability in GMA Welding (GMAW에서 와이어 송급속도의 변동이 아크안정성에 미치는 영향에 관한 연구)

  • 신현욱;최용범;성원호;장희석
    • Journal of Welding and Joining
    • /
    • v.13 no.4
    • /
    • pp.85-102
    • /
    • 1995
  • Weld quality of GMA welding processes is closely related to arc stability. Although many researches on arc stability have been performed, real-time estimation of arc stability has not been attempted. For instance, Mita proposed a off-line statistical method in which short circuiting and arcing time, and voltage and current wave forms were sampled to assess arc stability. But this method is not suitable to assess arc stability for GMA welder which employ inverter power source due to its controlled current and voltage wave forms. In this paper, the relationship between are stability and wire feed rate fluctuation is analyzed to propose new criterion for inverter power source. When arc voltage and arc current and arcing time are analyzed, we can assess arc stability only for short circuit transfer mode. When wire feed rate is analyzed, we can estimate arc stability udner the condition of spray transfer mode as well. Hence, the wire feed rate is chosen for monitoring process variable to cover possible metal transfer modes in GMAW. Through this research, it has been identified that arc stability in GMA welding processes is closely related to wire fed rate. When inverter power source is used, conventional statistical method of estimating arc stability, such as Mita index, is no longer valid due to its controlled voltage and current wave forms. Arc stability has been also examined in phase plane diagram.

  • PDF

System Thinking Perspective on the Dynamic Relationship between Organizational Characteristics of Nuclear Safety Culture

  • Kim, Byung Suk;Oh, Youngmin
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.2
    • /
    • pp.77-86
    • /
    • 2014
  • Objective: The purpose of this study is to grasp the fundamental structure of incident occurrence in nuclear organizations based on system thinking, and analyze how various causes are interrelated in terms of the causal loop diagram. Background: The recent domestic and overseas nuclear power plant-related incidents and accidents are directly or indirectly associated with safety culture, and thus effective plans for the improvement of safety culture are being called for. While the safety of a nuclear power plant is highly dependent upon technology and equipment, the utilization, maintenance and inspection of the technology and equipment are conducted by workers of the nuclear power plant. Method: Methodology of system thinking perspective using causal loop analysis. Results: As a result of the analysis, first, it turned out that the fundamental cause of incident occurrence in nuclear organizations is time constraint. Second, if a workload of workers increases, their adherence to regulations and procedures comes to be reduced due to time constraint. Third, it is needed, through organizational learning education, to increase actions made from thoughts considering safety as the utmost priority in advance. Fourth, it is necessary to improve professionalism by enhancing educational programs for new workers, and to develop various scenarios with which they can cope with certain situations. Application: This paper provides a base for system dynamics simulation model for future study.

Switch-Level Binary Decision Diagram(SLBDD) for Circuit Design Verification) (회로 설계 검증을 위한 스위치-레벨 이진 결정 다이어그램)

  • 김경기;이동은;김주호
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.5
    • /
    • pp.1-12
    • /
    • 1999
  • A new algorithm of constructing binary decision diagram(BDD) for design verification of switch-level circuits is proposed in this paper. In the switch-level circuit, functions are characterized by serial and parallel connections of switches and the final logic values may have high-impedance and unstable states in addition to the logic values of 0 and 1. We extend the BDD to represent functions of switch-level circuits as acyclic graphs so called switch-level binary decision diagram (SLBDD). The function representation of the graph is in the worst case, exponential to the number of inputs. Thus, the ordering of decision variables plays a major role in graph sizes. Under the existence of pass-transistors and domino-logic of precharging circuitry, we also propose an input ordering algorithm for the efficiency in graph sizes. We conducted several experiments on various benchmark circuits and the results show that our algorithm is efficient enough to apply to functional simulation, power estimation, and fault-simulation of switch-level design.

  • PDF

A Research on the Development of Quality Cost Management System for Power Industry (발전산업의 품질비용 관리체계 구축에 관한 연구)

  • Lee, Myong Chang;Hwang, Bong Sun;Park, Sang Jun;Kim, Min Gyu;Kim, Dong Chun;Shin, Wan Seon
    • Journal of Korean Society for Quality Management
    • /
    • v.44 no.4
    • /
    • pp.713-733
    • /
    • 2016
  • Purpose: The primary objective of this case study is to establish a COQ(Cost of Quality) management system for power generation industries. Key topics of this study include collecting COQ elements, their classifications, COQ computation formula, and determining COQ improvement projects. Results: A comprehensive set of COQ elements have been isolated for electric power generation companies. The COQ elements were classified in such a way that they could be managed according to the PAF model as well as the SIPOC diagram. This study showed that a systematic approach could be established for monitoring the COQ elements and using them in the process of improving quality competitiveness. Methods: The PAF(Prevention-Appraisal-Failure) model has been employed in the process of collecting COQ elements for a power generation company. All the cost of quality elements were first examined through an extensive review of articles and books in the field of quality. The cost elements were then refined and augmented by conducting a comparative study with international standards. The COQ elements have been verified by a group of quality managers and classified according to both the PAF model and the SIPOC diagram for better understanding in the entire organization. An improvement strategy has been also proposed by using a typical COQ level of power generation companies. Conclusion: The conventional PAF model was used in establishing a COQ management system for power generation industries. This case study illustrates the procedure about identification, classification and computation of quality costs, including selection of improvement projects. The system can be used not only for observing the current state of cost elements related to quality, but also for planning an improvement strategy using the ratio of cost classification.

Analysis and Compensation of PCC Voltage Variations caused by Wind Turbine Power Fluctuations

  • Im, Ji-Hoon;Song, Seung-Ho;Kang, San
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.854-860
    • /
    • 2013
  • The voltage variation problem at the point of common coupling (PCC) in a grid-connected wind turbine is investigated. The voltage variation problem is one of the most frequent power quality issues for the grid connection of large amounts of input power in a weak grid. Through the simplified modeling of the wind turbine and power network, the magnitude of PCC voltage variation is calculated by using the equivalent circuit parameters and output power of the wind turbine. The required amount of reactive power that can compensate the voltage variation is also presented analytically by using the vector diagram method. The proposed calculation and compensation method of the PCC voltage variation is verified by computer simulations and experiments.

A Study on Development of the Low Electrical Power Echo Sounder System for Coastal Use (연안목적용 저출력 어군탐지기 음향계의 개발에 관한 연구)

  • Park, Ju-Sam
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.3
    • /
    • pp.243-250
    • /
    • 2009
  • The expression of signal to noise ratio (SNR) is derived for the individual echo sounder and for the general specifications of commercial echo sounder. The SNR is depicted by several factors on transmitting and receiving, sound propagation, scattering by fishes, and mainly self ship noise. The detection ranges of echo sounders in depth and breadth are derived by finding the border of an acceptable SNR. The detection ranges are computed for the echo sounders of individual and general specifications. Generally, the detection range is lager for low frequencies. Increasing an electrical power and a diameter of transducer is not as effective for high frequencies as for low frequencies to increase the detection range. The theoretical results of the detection range can be applied to design low electrical power echo sounder for coastal use, to select an appropriate echo sounder, to know the capability of a sounder, and to interpret echograms. A method for evaluating and designing low electrical power echo sounder is developed. A universal diagram for the basic design of the low electrical power echo sounder where SNR is plotted against frequency is developed. An appropriate frequency, transducer diameter, and beam width are easily determined by using the diagram.

  • PDF