전압형 전력 변환기 비선형 모델 및 전류제어기 조정 (Non-Linear Model of Voltage Source Power Converter and Tuning Current controller)

  • 박상영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.144-146
    • /
    • 1998
  • In this study Dead time equivalent resistance of Voltage source power converter is very important in current controller design. And Non-linear Modeling method can be applied in Power converter analysis. Using Describing Function method and Non-linear Resistance Modeling. Voltage Source Power Converter Bode diagram and Current controller analysis method are more reality.

  • PDF

국내 전력산업의 효율성 제고모형에 대한 SD 모형 연구 - 원자력산업을 중심으로 (A SD approach to the Efficiency Improvement of Electric Power Industry in Korea -Focused on the Nuclear Industry)

  • 허훈;이명호
    • 한국시스템다이내믹스연구
    • /
    • 제4권2호
    • /
    • pp.153-171
    • /
    • 2003
  • In this study, we tried to build a model which can deal with the efficient and effective operation of electric power industry, especially focused on the nuclear industry. Here, SD(system Dynamics) approach is used to visualize the underlying phenomenon of the nuclear power industry. SD is a methodology for studying and managing complex feedback systems, such as one finds in business and other social systems, The span of SD applications has grown extensively and now encompasses work in corporate planning and policy design, public management and policy, biological and medical modeling, energy and the environment. Recently, according to the report from KEPCO(Korea Electric Power Corporation), they are considering delaying a new power plant construction. It may be based upon business fluctuation downsized from Korean economic crisis in 1997 and freezing of construction funds due to unstable foreign exchange rate. At this point, we need desperately a kind of strategic model that would contribute to cope with the current business situation, energy generation, Production, and resulting Pollution. Specifically, this model, using SD approach, starts with the detailed drawing of influence diagram, which describes those relevant key points on nuclear power generation systems in electric power industry of Korea. These include such (actors as the operation of nuclear industry and parameters related to the decision making for business policy. Based upon the above-mentioned influence diagram drawn, we developed SD simulation model to evaluate and analyze strategic management of KBPCO. Based on our analysis, we could demonstrate how simulation model can be applied to the real electric power generation in Korea.

  • PDF

시스템 다이내믹스(SD)에 의한 국내 전력산업의 효율성 제고에 관한 연구: 원자력산업을 중심으로 (A SD approach to the Efficiency Improvement of Electric Power Industry in Korea: Focused on the Nuclear Industry)

  • 이명호;이희상;장인성;최봉식;허훈
    • 한국경영과학회지
    • /
    • 제26권2호
    • /
    • pp.99-109
    • /
    • 2001
  • In this study, we tried to build a model which can deal with the efficient and effective operation of electric power industry, especially focused on the nuclear industry. Here, SD (System Dynamics) approach is used to visualize the underlying phenomenon of the nuclear power industry. SD is a methodology for studying and managing complex feedback systems, such as one finds in business and other social systems. The spend of SD applications has grown extensively and now encompasses work in corporate planning and policy design, public management and policy, biological and medical modeling, energy and the environment. Recently, according to the report from KEPCO (Korea Electric Power Corporation), they are considering delaying a new power plant construction. It may be based upon business fluctuation downsized from Korean economic crisis in 1997 and freezing of construction funds due to unstable foreign exchange rate. At this point, we need disparately a kind of strategic model that would contribute to cope with the current business situation, energy generation, production, and resulting pollution. Specifically, this model, using SD approach, starts with the detailed drawing of influence diagram, which describes those relevant key points on nuclear power generation systems in electric power industry of Korea. These include such factors as the operation of nuclear industry and parameters related to the decision making for business policy. Based upon the above-mentioned influence diagram drawn, we developed SD simulation model to evaluate and analyze strategic management of KEPCO. Based on our analysis, we could demonstrate how simulation model can be applied to the real electric power generation in Korea.

  • PDF

소프트패널을 이용한 발전소 운전원 훈련용 가상 시뮬레이터 개발 (The Development of Virtual Power Plant Simulator for Operator Training using Soft Panel)

  • 박신열
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.150-153
    • /
    • 2003
  • 한전 전력연구원은 기준 발전소 시뮬레이터가 없는 고리1호기 원자력발전소의 현황을 고려하여 주제 어실은 없지만 고리1호기의 운전특성을 나타내는 전범위 시뮬레이터개발의 1단계로서 강사 및 운전원 모니터에 나타나는 Soft Panel 만으로 운전훈련이 가능 하도록 하는데 목표를 두고 원자력발전소 운 전원 훈련용 시뮬레이터를 개발 하였다. 본 논문에서는 상기의 개발내용 중에서 시뮬레이션 시스템 구성, 컴퓨터별 주요기능, 강사제어 프로그램, 운전원제어 프로그램, Simulation Diagram 화면, Soft Panel 화면, 시뮬레이터 연동 등에 대한 내용을 기술하고자 한다.

  • PDF

GMAW에서 와이어 송급속도의 변동이 아크안정성에 미치는 영향에 관한 연구 (Effects of Wire speed Fluctuation on Arc Stability in GMA Welding)

  • 신현욱;최용범;성원호;장희석
    • Journal of Welding and Joining
    • /
    • 제13권4호
    • /
    • pp.85-102
    • /
    • 1995
  • Weld quality of GMA welding processes is closely related to arc stability. Although many researches on arc stability have been performed, real-time estimation of arc stability has not been attempted. For instance, Mita proposed a off-line statistical method in which short circuiting and arcing time, and voltage and current wave forms were sampled to assess arc stability. But this method is not suitable to assess arc stability for GMA welder which employ inverter power source due to its controlled current and voltage wave forms. In this paper, the relationship between are stability and wire feed rate fluctuation is analyzed to propose new criterion for inverter power source. When arc voltage and arc current and arcing time are analyzed, we can assess arc stability only for short circuit transfer mode. When wire feed rate is analyzed, we can estimate arc stability udner the condition of spray transfer mode as well. Hence, the wire feed rate is chosen for monitoring process variable to cover possible metal transfer modes in GMAW. Through this research, it has been identified that arc stability in GMA welding processes is closely related to wire fed rate. When inverter power source is used, conventional statistical method of estimating arc stability, such as Mita index, is no longer valid due to its controlled voltage and current wave forms. Arc stability has been also examined in phase plane diagram.

  • PDF

System Thinking Perspective on the Dynamic Relationship between Organizational Characteristics of Nuclear Safety Culture

  • Kim, Byung Suk;Oh, Youngmin
    • 대한인간공학회지
    • /
    • 제33권2호
    • /
    • pp.77-86
    • /
    • 2014
  • Objective: The purpose of this study is to grasp the fundamental structure of incident occurrence in nuclear organizations based on system thinking, and analyze how various causes are interrelated in terms of the causal loop diagram. Background: The recent domestic and overseas nuclear power plant-related incidents and accidents are directly or indirectly associated with safety culture, and thus effective plans for the improvement of safety culture are being called for. While the safety of a nuclear power plant is highly dependent upon technology and equipment, the utilization, maintenance and inspection of the technology and equipment are conducted by workers of the nuclear power plant. Method: Methodology of system thinking perspective using causal loop analysis. Results: As a result of the analysis, first, it turned out that the fundamental cause of incident occurrence in nuclear organizations is time constraint. Second, if a workload of workers increases, their adherence to regulations and procedures comes to be reduced due to time constraint. Third, it is needed, through organizational learning education, to increase actions made from thoughts considering safety as the utmost priority in advance. Fourth, it is necessary to improve professionalism by enhancing educational programs for new workers, and to develop various scenarios with which they can cope with certain situations. Application: This paper provides a base for system dynamics simulation model for future study.

회로 설계 검증을 위한 스위치-레벨 이진 결정 다이어그램 (Switch-Level Binary Decision Diagram(SLBDD) for Circuit Design Verification))

  • 김경기;이동은;김주호
    • 전자공학회논문지C
    • /
    • 제36C권5호
    • /
    • pp.1-12
    • /
    • 1999
  • 본 논문에서는 스위치-레벨 회로의 검증(verification)을 위해서 이진 결정 다이어그램(BDD : Binary Decision Diagram)을 구현하는 새로운 알고리즘을 제안한다. 스위치-레벨에서 기능(function)들은 스위치들의 직$\cdot$병렬 연결에 의해서 결정되며, 결과 논리 값은 논리 '0'과 '1'뿐만 아니라, 초기 상태, 고 임피던스와 불안정 상태를 가진다. 따라서, 본 논문에서는 "스위치-레벨 이진 결정 다이어그램(SLBDD : Switch- Level Bianary Decision Diagram)"으로 정의한 비 사이클 그래프(acyclic graph)들을 사용해서 스위치-레벨 회로의 가능들을 표현하도록 BDD를 확장하였다. 그러나, 그래프의 기능적 표현을 최악의 경우 입력 변수들의 수에 지수 함수적이 되므로, 결정 다이어그램의 변수 순서(ordering)는 그래프 크기에 주된 역할을 하게된다. 따라서, 패스-트랜지스터와 도미노-논리가 존재하는 사전에 충전하는 회로(Precharging circuitry)에서 그래프 크기에서의 효율성을 위한 입력 순서 알고리즘을 제안한다. 그리고, 실험 결과는 여러 가지 벤치-마크 회로에서 여러 번의 실험을 통해서 제안된 알고리즘이 스위치-레벨에서의 기능적 시뮬레이션, 전력 측정과 결점 시뮬레이션에 적용될 수 있을 만큼 충분히 효율적임을 보여준다.율적임을 보여준다.

  • PDF

발전산업의 품질비용 관리체계 구축에 관한 연구 (A Research on the Development of Quality Cost Management System for Power Industry)

  • 이명창;황봉순;박상준;김민규;김동준;신완선
    • 품질경영학회지
    • /
    • 제44권4호
    • /
    • pp.713-733
    • /
    • 2016
  • Purpose: The primary objective of this case study is to establish a COQ(Cost of Quality) management system for power generation industries. Key topics of this study include collecting COQ elements, their classifications, COQ computation formula, and determining COQ improvement projects. Results: A comprehensive set of COQ elements have been isolated for electric power generation companies. The COQ elements were classified in such a way that they could be managed according to the PAF model as well as the SIPOC diagram. This study showed that a systematic approach could be established for monitoring the COQ elements and using them in the process of improving quality competitiveness. Methods: The PAF(Prevention-Appraisal-Failure) model has been employed in the process of collecting COQ elements for a power generation company. All the cost of quality elements were first examined through an extensive review of articles and books in the field of quality. The cost elements were then refined and augmented by conducting a comparative study with international standards. The COQ elements have been verified by a group of quality managers and classified according to both the PAF model and the SIPOC diagram for better understanding in the entire organization. An improvement strategy has been also proposed by using a typical COQ level of power generation companies. Conclusion: The conventional PAF model was used in establishing a COQ management system for power generation industries. This case study illustrates the procedure about identification, classification and computation of quality costs, including selection of improvement projects. The system can be used not only for observing the current state of cost elements related to quality, but also for planning an improvement strategy using the ratio of cost classification.

Analysis and Compensation of PCC Voltage Variations caused by Wind Turbine Power Fluctuations

  • Im, Ji-Hoon;Song, Seung-Ho;Kang, San
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.854-860
    • /
    • 2013
  • The voltage variation problem at the point of common coupling (PCC) in a grid-connected wind turbine is investigated. The voltage variation problem is one of the most frequent power quality issues for the grid connection of large amounts of input power in a weak grid. Through the simplified modeling of the wind turbine and power network, the magnitude of PCC voltage variation is calculated by using the equivalent circuit parameters and output power of the wind turbine. The required amount of reactive power that can compensate the voltage variation is also presented analytically by using the vector diagram method. The proposed calculation and compensation method of the PCC voltage variation is verified by computer simulations and experiments.

연안목적용 저출력 어군탐지기 음향계의 개발에 관한 연구 (A Study on Development of the Low Electrical Power Echo Sounder System for Coastal Use)

  • 박주삼
    • 해양환경안전학회지
    • /
    • 제15권3호
    • /
    • pp.243-250
    • /
    • 2009
  • 연안에서 목적으로 하는 어업에 적합하도록 소형 어군탐지기를 효율적으로 설계하고 평가할 수 있는 방법에 대해 검토하기 위하여 일반적으로 사용되고 있는 어군탐지기의 특성과 탐지범위 등에 대해 조사하였다. 먼저 일반적인 어군탐지기의 빔폭은 주파수와 송신전력이 상승함에 따라 좁아지고 송수파기의 직경은 송신전력이 증가함에 커지는 경향을 보였다. 이 특성을 이용하여 상업적으로 사용되는 일반적인 어군탐지기의 신호대 잡음비를 유도하였다. 탐지거리와 탐지폭으로 구성되는 탐지범위는 이 신호대 잡음비(SN비)로부터 얻을 수 있다. 탐지거리는 주파수의 증가와 함께 증가하였지만 고주파에서는 흡수계수의 영향으로 원거리 탐지가 어려워진다. 즉 송수파기 직경, 송신전력의 증가에 따른 효과는 저주파에서는 크고, 고주파에서는 적은 경향을 보인다. 탐지범위 등을 종합적으로 응용하여 휴대용 어군탐지기의 설계 범용도를 작성하였다. 범용도에는 SN비를 송수파기의 직경, 빔폭, 탐지거리를 변수로하여 주파수에 대해 표시하였다. 범용도에서 SN비가 높고 실용성이 높은 적절한 설계영역을 표시하였다. 설계영역에서 설계점을 정하면 전체적으로 적절한 설계를 할 수 있다. 설계범용도는 어군탐지기의 성능평가에도 응용할 수 있다.

  • PDF