• 제목/요약/키워드: Power Conversion Efficiency

검색결과 1,156건 처리시간 0.027초

고온초전도체 베어링을 사용하는 플라이휠 에너지 저장 시스템을 위한 전력변환 시스템 (Electric Power Conversion System for Flywheel Energy Storage System using High Tc Superconducting Bearings)

  • 정환명;최재호;이호진;홍계원
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.305-309
    • /
    • 1999
  • This paper presents an high efficiency energy conversion system for very high-speed flywheel energy storage system using high Tc superconducting bearings. Main configuration of power convertor is designed to replace of the conventional battery with EMB(Electro Mechanical Battery). PMSM(Permanent Magnet Synchronous Motor) using Halbach array is used as the energy conversion system of motor and generator. Some PWM methods for the high frequency inverter is described and the power factor effects to the torque characteristics and efficiency of the motor and generator is analyzed. As the results, it is verified that the inverter output current is well regulated to be in-phase or inverse-phase sinusoidal waveform to have the wide operational range from 2,500rpm to 42,000rpm. Proposed circuit is designed to obtain the very high speed, high efficiency and stable rotational characteristics, and to be applied to1.2r[kW]/65[Wh] system.

  • PDF

발전소 복수기 배열회수 해양온도차 발전설비 적용타당성 검토 (Feasibility Study on Modified OTEC (Ocean Thermal Energy Conversion) by Plant Condenser Heat Recovery)

  • 정훈;김경열;허균영
    • 신재생에너지
    • /
    • 제6권3호
    • /
    • pp.22-29
    • /
    • 2010
  • The concept of Ocean Thermal Energy Conversion (OTEC) is simple and various types of OTEC have been proposed and tried. However the location of OTEC is limited because OTEC requires $20^{\circ}C$ of temperature difference as a minimum, so most of OTEC plants were constructed and experimented in tropical oceans. To solve this we proposed the modified OTEC which uses condenser discharged thermal energy of existing fossil or nuclear power plants. We call this system CTEC (Condenser Thermal Energy Conversion) as this system directly uses $32^{\circ}C$ partially saturated steam in condenser instead of $20{\sim}25^{\circ}C$ surface sea water as heat source. Increased temperature difference can improve thermal efficiency of Rankine cycle, but CTEC should be located near existing plant condenser and the length of cold water pipe between CTEC and deep cold sea water also increase. So friction loss also increases. Calculated result shows the change of efficiency, pumping power, net power and other parameters of modeled 7.9 MW CTEC at given condition. The calculated efficiency of CTEC is little larger than that of typical OTEC as expected. By proper location and optimization, CTEC could be considered another competitive renewable energy system.

증기-액 이젝터를 적용한 해양온도차발전 시스템의 성능 특성 (Performance Characteristics of OTEC(Ocean Thermal Energy Conversion) Power Cycle with Vapor-Liquid Ejector)

  • 윤정인;손창효;김현욱;하수정;이호생;김현주
    • 동력기계공학회지
    • /
    • 제18권5호
    • /
    • pp.88-93
    • /
    • 2014
  • In this paper, the performance analysis of condensation and evaporation capacity, turbine work and efficiency of the OTEC power system using vapor-liquid Ejector is presented to offer the basic design data for the operating parameters of the system. The working fluid used in this system is $CO_2$. The operating parameters considered in this study include the vapor quality at heat exchanger outlet, pressure ratio of ejector and inlet pressure of low turbine, mass flow ratio of separator at condenser outlet. The main results were summarized as follows. The efficiency of the OTEC power cycle has an enormous effect on the mass flow ratio of separator at condenser outlet. With a thorough grasp of these effects, it is possible to design the OTEC power cycle proposed in this study.

효율적 건강보험수가에 기반을 둔 병원 그룹화에 관한 연구 -AHP와 DEA를 이용한 분석- (A Study on the discriminating of the hospitals based on the efficient insurance conversion factor by AHP and DEA)

  • 오동일
    • 한국산학기술학회논문지
    • /
    • 제10권6호
    • /
    • pp.1304-1316
    • /
    • 2009
  • 본 연구는 효율성에 기초한 환산지수의 도입 가능성을 알아보기 위한 기초 연구로 시도되었다. DEA 효율성지표와 환산지수가 전공의 수련교육을 실시하고 있는 60 개 병원을 그룹화하는데 얼마나 유용하게 사용될 수 있는가를 고찰하였다. 이러한 목적을 달성하기 위해 자료수집이 가능한 표본병원의 환산지수와 AHP 개념을 도입해 DEA 모형의 투입변수와 산출변수를 선정하였다. 그 결과 병상규모가 클수록 규모적 비효율성이 큰 것으로 나타났으며 기술적으로 또는 규모적으로 비효율적인 병원일수록 환산지수가 더 큰 것으로 나타났다. 환산지수와 효율성지표는 수련병원을 병원의 종별에 따라 종합전문병원과 종합병원으로 구분하는데 유용하게 사용될 수 있었다. 또한 DEA 효율성을 구하는 과정에서 독립변수로 사용된 투입 산출변수를 판별함수에 도입하였음에도 불구하고 환산지수와 효율성지표는 판별함수를 구성하는 주요 변수로 작용함을 확인하였다. 따라서 만약 모집단을 대표할 수 있는 많은 표본을 기초로 보다 명확한 결과를 얻을 수 있다면 건강보험의 수가계약제 하에서 효율성 개념을 바탕으로 한 환산지수계약의 도입을 신중하게 고려해 볼 수 있다.

운전조건 변화가 HCNG 엔진용 삼원촉매 전환효율에 미치는 영향 (Effect of Operating Condition Change on the Conversion Efficiency of TWC with HCNG Engine)

  • 김창기;이성원;이의형;박철웅;이선엽;최영;이장희
    • 한국가스학회지
    • /
    • 제19권6호
    • /
    • pp.40-46
    • /
    • 2015
  • 이론공연비방식 엔진은 삼원촉매를 이용하여 유해배기가스를 매우 효과적으로 저감시킬 수 있는 장점을 가지고 있다. 삼원촉매는 높은 정화효율을 보이는 공연비범위가 좁기 때문에 엔진에서의 공연비 제어가 매우 중요하다. 본 연구에서는 삼원촉매 성능을 평가하기 위하여 다양한 운전영역에서 삼원촉매의 전환효율을 비교 분석하였다. 최적의 전환효율을 보이는 당량비를 확인하기 위하여 당량비 제어값 변화에 의한 전환효율을 살펴보았다. 실험결과 당량비 제어를 통하여 각 운전조건에서 NMHC, CH4, CO 및 NOx의 전환효율이 95%이상 나타내는 최적 운전조건을 찾을 수 있었다. 동등한 배기가스 온도 조건에서는 출력이 증가할수록 최적당량비가 선형적으로 증가하는 경향을 보였다.

Load Dispatching Control of Multiple-Parallel-Converters Rectifier to Maximize Conversion Efficiency

  • Orihara, Dai;Saitoh, Hiroumi;Higuchi, Yuji;Babasaki, Tadatoshi
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.1132-1136
    • /
    • 2014
  • In the context of increasing electric energy consumption in a data center, energy efficiency improvement is strongly emphasized. In a data center, electric energy is largely consumed by DC power supply system, which is based on a rectifier composed by multiple parallel converters. Therefore, rectifier efficiency must be improved for minimizing loss of DC power supply system. Rectifier efficiency can be modulated by load allocation to converters because converter efficiency depends on input AC power. In this paper, we propose a new control method to maximize rectifier efficiency. The method can control load allocation to converters by introducing active power converter control scheme and start-and-stop of converters. In order to illustrate optimal load allocations in a rectifier, a maximization problem of rectifier efficiency is formulated as a nonlinear optimization one. The problem is solved by Lagrangian relaxation method and the computation results provide the validity of proposed method.

강유전 고분자 박막을 이용한 유기고분자 태양전지에서의 효율 증대 (Efficiency Enhancement in Organic Polymer Solar Cells with Ferroelectric Films)

  • 박자영;정치섭
    • 한국전기전자재료학회논문지
    • /
    • 제30권2호
    • /
    • pp.126-132
    • /
    • 2017
  • The power conversion efficiency of organic polymer solar cells was enhanced by introducing a ferroelectric polymer layer at the interface between active layer and metal electrode. The power conversion efficiency was increased by 50% through the enhancement of the open circuit voltage. To investigate the role of the ferroelectric layer on the dissociation process of the excitons, non-radiative portion of the exciton decay was directly measured by using photoacoustic technique. The results show that the ferroelectric nature of the buffer layer does not play any roles on the dissociation process of the excitons, which indicates the efficiency enhancement is not due to the ferroelectricity of the buffer layer.

고효율 운전이 가능한 지능형 무정전 전원장치에 관한 연구 (A Study of Smart Uninterruptible Power Supply Capable High Efficiency Drive)

  • 엄태욱
    • 조명전기설비학회논문지
    • /
    • 제27권5호
    • /
    • pp.61-66
    • /
    • 2013
  • In this paper, a control scheme with the capability of high efficiency, which is realized by predicting the conditions of a load power and an input power, is proposed for the uninterruptible power supply (UPS). Generally, on-line UPS system supplies a constant voltage and a constant frequency (CVCF). However, the efficiency of the On-line UPS system can be reduced due to the switching losses of semiconductor devices during the power conversion. The these losses are improved by the proposed smart UPS with the high efficiency drive system, which is realized by analysing and predicting the conditions of a load power and an input power.

Optimized Design of Bi-Directional Dual Active Bridge Converter for Low-Voltage Battery Charger

  • Jeong, Dong-Keun;Ryu, Myung-Hyo;Kim, Heung-Geun;Kim, Hee-Je
    • Journal of Power Electronics
    • /
    • 제14권3호
    • /
    • pp.468-477
    • /
    • 2014
  • This study proposes an optimized design of a dual active bridge converter for a low-voltage charger in a military uninterrupted power supply (UPS) system. The dual active bridge converter is among various bi-directional DC/DC converters that possess a high-efficiency isolated bi-directional converter. In the general design, the zero-voltage switching(ZVS) region is reduced when the battery voltage is high. By contrast, efficiency is low because of high conduction losses when the battery voltage is low. Variable switching frequency is applied to increase the ZVS region and the power conversion efficiency, depending on battery voltage changes. At the same duty, the same power is obtained regardless of the battery voltage using the variable switching frequency. The proposed method is applied to a 5 kW prototype dual active bridge converter, and the experimental results are analyzed and verified.

Terahertz Generation Based on Cascaded Difference Frequency Generation with Periodically-poled KTiOPO4

  • Li, Zhongyang;Wang, Silei;Wang, Mengtao;Wang, Weishu
    • Current Optics and Photonics
    • /
    • 제1권2호
    • /
    • pp.138-142
    • /
    • 2017
  • Terahertz (THz) generation by periodically-poled $KTiOPO_4$ (PPKTP) with a quasi-phase-matching scheme based on cascaded difference frequency generation (DFG) processes is theoretically analyzed. The cascaded Stokes interaction processes and the cascaded anti-Stokes interaction processes are investigated from coupled wave equations. THz intensities and quantum conversion efficiency are calculated. Compared with non-cascaded DFG processes, THz intensities from 10-order cascaded DFG processes are increased to 5.53. The quantum conversion efficiency of 479.4% in cascaded processes, which exceeds the Manley-Rowe limit, can be realized.