• Title/Summary/Keyword: Power Base

Search Result 1,979, Processing Time 0.026 seconds

Effect of CrossFit Power Training on TPI OnBaseU Power Test and Golf Performance (크로스핏 파워 트레이닝이 TPI OnBaseU Power Test와 골프 수행력에 미치는 영향)

  • Chang Wook Kim
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.4
    • /
    • pp.185-195
    • /
    • 2023
  • Objective: The purpose of this study is to improve TPI OnBaseU Power Test and golf performance by conducting CrossFit power training. Method: Three male golf players from University B participated in this study. They had 3 to 4 years of golf experience and participated in 8 weeks of CrossFit power training. Results: OnBaseU Power Test: There was a lot of improvement in Sit up throw (27.9%) and Chest pass (10.58%), but there was not much improvement in Baseline Toss (R5.9, L9.8%) and Vertical Jump (4.1%). Golf shot data: There was a very statistically significant difference in Club speed, Ball speed, and Total Length, which are related to speed, and there was no difference in Club path and Smash factor, which are related to accuracy and posture. Conclusion: CrossFit power training was effective in improving TPI OnBaseU Power Test and golf performance (Club speed, Ball speed, Total Length).

A Study on measurement for effective isotropic radiated power based power management of the base stations (등가등방성복사전력 기반의 기지국 출력 관리를 위한 측정 연구)

  • Lim, Jae-Choon;Kim, Jong-Heon;Moon, Sung-Won;Lee, Young-Hwan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.6
    • /
    • pp.118-125
    • /
    • 2011
  • In this paper, a WCDMA experimental base station is constructed for power management of mobile communication base station and effective isotropic radiated power is determined by using received power of pilot channel measured on the line-of sight. The measurement system was constructed by a experimental base station and a measurement receiver and the common pilot channel (CPICH) power of the base station was measured. Effective isotropic radiated power (EIRP) of the base station obtained by the measurement value considering correction factor for the errors represented the difference of 0.5 dB compared to the established EIRP of the base station.

A Study on the Output Power Optimization of Mobile WiMAX Base Station (Mobile WiMAX 기지국의 최적 출력파워 도출에 관한 연구)

  • Kim, Sung-Man
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.4A
    • /
    • pp.341-349
    • /
    • 2010
  • In this paper, we studied on the optimization of the output power of Mobile WiMAX (IEEE 802.16) base station considering the technical condition of base station and wireless channel condition. The optimum power of base station can be estimated based on the link budget calculation of downlink and uplink in the Mobile WiMAX communication system. We investigated the optimum output power of base station in the case of 2Tx-2Rx base station with $2{\times}2$ MIMO(multiple input multiple output) technology, 2Tx-4Rx base station with improved receiver sensitivity, and 4Tx-4Rx base station with beamforming technology.

Power Saving Mechanisms for LTE Base Stations Using Traffic Characteristic (Traffic 특성을 이용한 LTE 기지국의 Power Saving 메커니즘)

  • Lee, Seung-Hwan;Lee, Seung-Hyong
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.1
    • /
    • pp.49-54
    • /
    • 2010
  • 3GPP(Third Generation Partnership Project) LTE system that is the next step forward in cellular 3G services address the issues related to power saving at LTE base station. This is because that most of the energy in a typical telecommunication network is consumed by the wireless network's base station site. Power saving at LTE base station fall in with low-carbon green technology. This thesis proposes a power saving MAC protocol for LTE base station which utilizes different graded DRX/DTX(Discontinuous. Reception/Transmission). Considering traffic type in UE, proposed MAC protocol controls adaptive DRX/DTX cycle. The proposed method is more improve power saving performance than another method which is unchanged DRX/DTX by conditions. In this thesis, I propose an power saving MAC protocol in an environment where LTE base station are communicated with UE and prove improvement in performance through simulations.

The Analysis of Reducing Power Consumption and CO2 Emission in the Advanced Mobile Communication Base Station (다중 대역용 차세대 이동통신 기지국 시스템의 전력 및 탄소배출량 절감효과 분석)

  • Oh, Sung-Kon;An, Jun-O;Kim, Boo-Gyoun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.6B
    • /
    • pp.642-649
    • /
    • 2011
  • In this paper, we present the analysis of the characteristics of advanced mobile communication base station with multi-band about power loss, power efficiency and carbon reduction considering cable power loss. The advanced mobile base station system is installed on the outdoor for Antenna and RF part, and then the power loss is reduced because the fiber optic cable is used between RF part and baseband part. If the cable power loss is reduced by 5 dB replacing an entire the advanced base station systems, annual power consumption is reduced total 49,038 MWh in the CDMA 20W, WCDMA 30W, WiBro 10W systems. Furthermore the advanced base station system of annual $CO_2$ emission is 20,832 $tCO_2$ compare to 65,878 $tCO_2$. Therefore the advanced base system is confirmed considering green IT technology for the advanced mobile communication base station.

Application of Fuzzy Algorithm with Learning Function to Nuclear Power Plant Steam Generator Level Control

  • Park, Gee-Yong-;Seong, Poong-Hyun;Lee, Jae-Young-
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.1054-1057
    • /
    • 1993
  • A direct method of fuzzy inference and a fuzzy algorithm with learning function are applied to the steam generator level control of nuclear power plant. The fuzzy controller by use of direct inference can control the steam generator in the entire range of power level. There is a little long response time of fuzzy direct inference controller at low power level. The rule base of fuzzy controller with learning function is divided into two parts. One part of the rule base is provided to level control of steam generator at low power level (0%∼30% of full power). Response time of steam generator level control at low power level with this rule base is shown generator level control at low power level with this rule base is shown to be shorter than that of fuzzy controller with direct inference.

  • PDF

A Fundamental Study for Establishment of Channel Data Base in Power-Line Communications (전력선 통신 채널 Data Base 구축을 위한 기본 연구)

  • Oh Hui-Myoung;Kim Kwan-Ho;Lee Won-Tae;Lee Jae-Jo
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.2
    • /
    • pp.107-111
    • /
    • 2003
  • In the power-line communication systems, there are many factors of noise and attenuation in the power-line channels, because they were designed for not the communication but the power transmission. Also the transfer function of the channels is highly changed with the topology and the load of the power-lines. To cope with these poor channel situation, channel modeling, one of the many studies in progress, is being studied hard. Channel modeling is essential to apply the active schemes to overcome the bad channel(e.g. modulation technique, channel coding, signal coupling & filtering, etc.) to the power-line communications. In this paper, we have realized the statistical model(this model is suggested as the channel modeling method for the power-line channels) that is combined the transfer function with the various noises. And we have compared and examined the results with the measured data. Also we have studied the plan which can effectively establish the channel data base for the channel information consisted of the parameters that are derived from this modeling, and we have studied the plan to utilize the data base.

Seismic assessment of base-isolated nuclear power plants

  • Farmanbordar, Babak;Adnan, Azlan Bin;Tahir, Mahmood Md.;Faridmehr, Iman
    • Advances in Computational Design
    • /
    • v.2 no.3
    • /
    • pp.211-223
    • /
    • 2017
  • This research presented a numerical and experimental study on the seismic performance of first-generation base-isolated and fixed-base nuclear power plants (NPP). Three types of the base isolation system were applied to rehabilitate the first-generation nuclear power plants: frictional pendulum (FP), high-damping rubber (HDR) and lead-rubber (LR) base isolation. Also, an Excel program was proposed for the design of the abovementioned base isolators in accordance with UBC 97 and the Japan Society of Base Isolation Regulation. The seismic assessment was performed using the pushover and nonlinear time history analysis methods in accordance with the FEMA 356 regulation. To validate the adequacy of the proposed design procedure, two small-scale NPPs were constructed at Universiti Teknologi Malaysia's structural laboratory and subjected to a pushover test for two different base conditions, fixed and HDR-isolated base. The results showed that base-isolated structures achieved adequate seismic performance compared with the fixed-base one, and all three isolators led to a significant reduction in the containment's tension, overturning moment and base shear.

A Study on Prediction of Fatigue Life and Shock Fracture for the Engine Base of Auxiliary Power Unit for Tracked Vehicle (보조동력장치 엔진 Base의 피로수명 예측 및 충격파손에 관한 연구)

  • Lee, Sang-Bum;Chung, Kyung-Taek;Shin, Jae-Ho;Jang, Hwan-Young;Suh, Jeong-Se
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.4
    • /
    • pp.86-92
    • /
    • 2008
  • This paper is to investigate the behavior of linear static structure stress, the fatigue and experimental shock fracture far engine base in the Auxiliary Power Unit to resolve its restricted electrical power problem. The shock fracture test was experimentally made under MIL standard criteria. The numerical results by finite element method had a good agreement with those from the shock test. The design data of predicting the fracture at the initial crack and the damage behavior of structure with shock and vibration load in the battle field can be obtained from shock test. In the functional shock test, the crack at the side parts of the engine base was found at peak acceleration of 40g.

Wavelet analysis of soil-structure interaction effects on seismic responses of base-isolated nuclear power plants

  • Ali, Shafayat Bin;Kim, Dookie
    • Earthquakes and Structures
    • /
    • v.13 no.6
    • /
    • pp.561-572
    • /
    • 2017
  • Seismic base isolation has been accepted as one of the most popular design procedures to protect important structures against earthquakes. However, due to lack of information and experimental data the application of base isolation is quite limited to nuclear power plant (NPP) industry. Moreover, the effects of inelastic behavior of soil beneath base-isolated NPP have raised questions to the effectiveness of isolation device. This study applies the wavelet analysis to investigate the effects of soil-structure interaction (SSI) on the seismic response of a base-isolated NPP structure. To evaluate the SSI effects, the NPP structure is modelled as a lumped mass stick model and combined with a soil model using the concept of cone models. The lead rubber bearing (LRB) base isolator is used to adopt the base isolation system. The shear wave velocity of soil is varied to reflect the real rock site conditions of structure. The comparison between seismic performance of isolated structure and non-isolated structure has drawn. The results show that the wavelet analysis proves to be an efficient tool to evaluate the SSI effects on the seismic response of base-isolated structure and the seismic performance of base-isolated NPP is not sensitive to the effects in this case.