• Title/Summary/Keyword: Power Balance Method

Search Result 354, Processing Time 0.033 seconds

Lifetime estimation of a covered overhead line conductor

  • Leskinen, Tapio;Kantola, Kari
    • Wind and Structures
    • /
    • v.6 no.4
    • /
    • pp.307-324
    • /
    • 2003
  • The paper presents results of studies concerning wind-induced aeolian vibration and fatigue of a 110 kV covered conductor overhead line. Self-damping measurement techniques are discussed: power method is found to be the most reliable technique. A method for compensating tension variations during the self-damping test is presented. Generally used empirical self-damping power models are enhanced and the different models are compared with each other. The Energy Balance Analysis (EBR) is used to calculate the aeolian vibration amplitudes, which thereafter are converted to bending stress for the calculation of conductor lifetime estimate. The results of EBA are compared with field measurements, Results indicate that adequate lifetime estimates are produced by EBA as well as field measurements. Generally the EBA gives more conservative lifetime expectancy. This is believed to result from the additional damping existing in true suspension structures not taken into account by EBA. Finally, the correctness of the line design is verified using Cigre's safe design tension approach.

Suggestion of Power and Heat Costing for an Energy System (에너지 시스템에 대한 전력 및 열 비용산정)

  • 김덕진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.360-371
    • /
    • 2003
  • The calculation of each unit cost of productions is very important for evaluating the economical efficiency and deciding the reasonable sale price. In the present, two methods of exergy costing on multiple energy systems are suggested to reduce the complexities of conventional SPECO method and MOPSA method and to improve the calculation efficiency of exergoeconomics. The suggested methods were applied to a gas-turbine cogeneration and the unit costs of the power and the steam energy were calculated as an example. The main points of our methods are the following three. First, one exergetic cost is applied to one cycle or system. Second, the suggested equations are the internal cost balance equation and the production cost balance equation. Third, necessary states in a system are only inlet and exit states of 1ha components producing energy.

A Study on the Charge Balance Characteristics of Super Junction MOSFET with Deep-Trench Technology (Deep-Trench 기술을 적용한 Super Junction MOSFET의 Charge Balance 특성에 관한 연구)

  • Choi, Jong-Mun;Huh, Yoon-Young;Cheong, Heon-Seok;Kang, Ey-Goo
    • Journal of IKEEE
    • /
    • v.25 no.2
    • /
    • pp.356-361
    • /
    • 2021
  • Super Junction structure is the proposed structure to minimize the Trade-off phenomenon of power devices. Super Junction can have On-resistance(Ron) characteristics as less as five times than conventional structure. There are process methods that Multi-Epi and Deep-Trench of Super Junction structure. The reason for this is that Deep-Trench process is known to be a relatively difficult manufacturing method because it is easy to form a P-Pillar by burying impurities on top of a silicon substrate through a Deep-Trench process. However, the structure created by the Deep-Trench process has low On-resistance and high breakdown voltage, showing better efficiency. In this paper, we suggested a novel method in the process and designed structure with Charge Balance theory.

Power System Security Control Method for Quench Characteristic of High-Temperature Superconducting Cable (초전도 케이블의 Quench 특성에 대한 계통안전성 제어방식)

  • Lee, Geun-Joon;Hwang, Si-Dol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.29-35
    • /
    • 2005
  • This paper presents the basic quench protection idea for the HTS(High-Temperature Superconducting) cable. In Korea power system, the transfer capability of transmission line is limited by the voltage stability, HTS cable could be one of the countermeasure to enhance the transfer limit with its higher current capacity and lower impedance[1]. However, the quench characteristic makes not only HTS cable to loss its superconductivity, but also change the impedance of the transmission line and power system operating condition dramatically. This pheonominum threats HTS cable safety as well as power system security, therefore a proper protection scheme and security control counterplan have to be established before HTS cable implementation. In this paper, the quench characteristics of HTS cable for the fault current based on heat balance equation was established and a proper protection method regarding conventional protection system was suggested.

Real-time Optimal Operation Planning of Isolated Microgrid Considering SOC balance of ESS

  • Lee, Yoon Cheol;Shim, Ji Yeon;Kim, Jeongmin;Ryu, Kwang Ryel
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.10
    • /
    • pp.57-63
    • /
    • 2018
  • The operating system for an isolated microgrid, which is completely disconnected from the central power system, aims at preventing blackouts and minimizing power generation costs of diesel generators through efficient operation of the energy storage system (ESS) that stores energy produced by renewable energy generators and diesel generators. In this paper, we predict the amount of renewable energy generation using the weather forecast and build an optimal diesel power generation plan using a genetic algorithm. In order to avoid inefficiency due to inaccurate prediction of renewable energy generation, our search algorithm imposes penalty on candidate diesel power generation plans that fail to maintain the SOC (state of charge) of ESS at an appropriate level. Simulation experiments show that our optimization method for maintaining an appropriate SOC balance can prevent the blackout better when compared with the previous method.

A Multi-level Optimal Power Flow Algorithm for Constrained Power Economic Dispatch Control (제약조건을 고려한 경제급전 제어를 위한 다단계 최적조류계산 알고리즘)

  • Song, Gyeong-Bin
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.9
    • /
    • pp.424-430
    • /
    • 2001
  • A multi-level optimal power flow(OPF) algorithm has been evolved from a simple two stage optimal Power flow algorithm for constrained power economic dispatch control. In the proposed algorithm, we consider various constraints such as ower balance, generation capacity, transmission line capacity, transmission losses, security equality, and security inequality constraints. The proposed algorithm consists of four stages. At the first stage, we solve the aggregated problem that is the crude classical economic dispatch problem without considering transmission losses. An initial solution is obtained by the aggregation concept in which the solution satisfies the power balance equations and generation capacity constraints. Then, after load flow analysis, the transmission losses of an initial generation setting are matched by the slack bus generator that produces power with the cheapest cost. At the second stage we consider transmission losses. Formulation of the second stage becomes classical economic dispatch problem involving the transmission losses, which are distributed to all generators. Once a feasible solution is obtained from the second stage, transmission capacity and other violations are checked and corrected locally and quickly at the third stage. The fourth stage fine tunes the solution of the third stage to reach a real minimum. The proposed approach speeds up the two stage optimization method to an average gain of 2.99 for IEEE 30, 57, and 118 bus systems and EPRI Scenario systems A through D testings.

  • PDF

Effect of exercise program using mirrors for stroke patients

  • Lee, Je-Hyeok;Kim, Hyun-Joo
    • International Journal of Contents
    • /
    • v.9 no.1
    • /
    • pp.60-64
    • /
    • 2013
  • This study was performed for two of specific reasons, one is for exercise development for improving stroke patient's muscle power, balance and gait and, after verifying the effect of the exercise, the other is for showing that the appling this exercise was more effective on hemi-plegic stroke patients into the clinical trial. The subjects of this study were hemi-plegic patients by stroke, 51 patients were picked up, who were agreed with this research. Close kinetic chain leg exercise using mirrors was applied to study group I, Close kinetic chain leg exercise without mirrors was applied to study group II and general physical therapy was applied to comparison group. The results of this study are as follows. The difference of the groups, study group I showed more effective than study group II on checking rectus femoris, vastus lateralis, biceps femoris, Korean version of Berg Balance Scale, Center of pressure, Functional gait assessment. In this study, Close kinetic chain leg exercise showed more effective and significant on improving for muscle power, balance and gait on stroke patients. Especially, doing exercise using mirrors is considered as more effective method than without mirrors.

A Study on Physical Fitness in Student Nurses (간호대학생의 체력에 관한 조사)

  • Kim Hyang-Dong;Park Jeong-Suk;Kwon Young-Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.10 no.3
    • /
    • pp.399-407
    • /
    • 2003
  • Purpose: This study was done to identify levels of physical fitness in student nurses and to ascertain the relationship among the different aspects of physical fitness of strength, power, muscle endurance, agility, balance and flexibility. Method: The participants were 266 students selected from one college of nursing. From May 1 to July 31 in 2003, physical constitution, muscle strength (grip strength, back strength), power (standing long jump), muscle endurance (sit-ups), agility (whole body reaction time-light, sound), balance (close-eyes foot-balance), and flexibility (sitting trunk flexion) were measured. Result: The mean(standard deviation) for grip strength was 22.59(3.93) kg., for back strength, 48.52(12.85) kg., for standing long jump, 135.29(20.54) m., for sit-up's, 23.66(9.35) per minute, whole body reaction time (light), 0.43(0.11) sec, whole body reaction time (sound), 0.50(0.16) sec, close-eyes foot-balance, 33.35(38.67) sec, and sitting trunk flexion 34.72(9.37) cm. Conclusion: This study showed that the physical fitness of student nurses is very low compared to the results in a report from the Korea Sports Science Institute. It is necessary to include exercise programs for student nurses in order to improve their physical fitness.

  • PDF

A Study on the Heat Balance of Cooling System for Armored Vehicles (밀폐형 차량 냉각시스템에 대한 열평형 연구)

  • Kim, S.K.;Ahn, S.H.;Nam, K.W.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.70-75
    • /
    • 2007
  • Heat transfer coefficient and fin efficiency of a heat exchanger dispersed in the microelement of control volume were predicted with various flow patterns, conditions and material properties. A computational program was developed by using the method of efficiency-NTU(Number of transfer unit). The modelling was applied to heat exchangers, also was integrated in power pack cooling system in an armored vehicle. The compatibility and the generality were proved by comparing the prediction values with the test results. The developed program may be useful for the design of the cooling system in an armored vehicle.

  • PDF

The Power Analysis and Its Control of Two-phase Orthogonal Power Supply for the Continuous Casting

  • Ma, Fujun;Luo, An;Xiong, Qiaopo
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.971-982
    • /
    • 2015
  • In order to improve the quality of the billet continuous casting, a two-phase orthogonal power supply (TPOPS) for electromagnetic stirrer is researched, which is composed of three-phase PWM rectifier and three-leg inverter. According to the power analysis of system, the ripple of dc-link voltage is analyzed and its analytical expression is derived. In order to improve the performance of electromagnetic stirring, an integrated control method with feedforward control is proposed for PWM rectifier to suppress the fluctuations of dc-link voltage and provide a stable dc source for inverter. According to the simplified equivalent model, a composite current control method is proposed for inverter. This proposed method can combine the merits of feedforward control with feedback control to effectively improve the dynamic output performance of TPOPS. Finally, a 300kVA prototype of TPOPS is developed, and the results have verified the analysis and control method.