• 제목/요약/키워드: Power Analysis Technique

검색결과 1,514건 처리시간 0.028초

철도차량내의 전력변환장치 출력전원 분석을 통한 스위칭 기법 추정 (The Estimation on Switching Technique via Output Power Source Analysis of Power Conversion System in an Electric Railway Vehicle)

  • 김재문;이을재;윤차중;김양수
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.185-190
    • /
    • 2010
  • This paper presents the estimation on switching technique via output power source analysis of power conversion unit in electric railway vehicle. The focus of this study suggested an alternative on critical problems by using head electric power(HEP). To achieve this, we have measured output power of HEP, and measurement devices set up at output of transformer connected HEP to analysis quality on output power source of head electric power(HEP) unit in electric railway vehicle. Using results of measurement of it, parameters are assumed for simulation to confirm estimation on switching technique. It is confirmed that switching technique is Selected Harmonic Elimination PWM(SHEPWM) and inverter switching frequency is less than 500[Hz]. Throughout experiment and simulation, it is estimated that switching technique used HEP is advanced SHEPWM and switching frequency is about 300[Hz]. Also leakage inductance in transformer is about $180[{\mu}H]$ less than $365[{\mu}H]$ known.

Power analysis attack resilient block cipher implementation based on 1-of-4 data encoding

  • Shanmugham, Shanthi Rekha;Paramasivam, Saravanan
    • ETRI Journal
    • /
    • 제43권4호
    • /
    • pp.746-757
    • /
    • 2021
  • Side-channel attacks pose an inevitable challenge to the implementation of cryptographic algorithms, and it is important to mitigate them. This work identifies a novel data encoding technique based on 1-of-4 codes to resist differential power analysis attacks, which is the most investigated category of side-channel attacks. The four code words of the 1-of-4 codes, namely (0001, 0010, 1000, and 0100), are split into two sets: set-0 and set-1. Using a select signal, the data processed in hardware is switched between the two encoding sets alternately such that the Hamming weight and Hamming distance are equalized. As a case study, the proposed technique is validated for the NIST standard AES-128 cipher. The proposed technique resists differential power analysis performed using statistical methods, namely correlation, mutual information, difference of means, and Welch's t-test based on the Hamming weight and distance models. The experimental results show that the proposed countermeasure has an area overhead of 2.3× with no performance degradation comparatively.

극점 배치 기법을 통한 DC-DC 컨버터의 제어 설계 (Pole placement technique for control design of DC-DC switchmode power converter)

  • 조윤제
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.480-484
    • /
    • 2000
  • The pole placement technique for control design of the current mode controlled DC-DC switchmode power converter is proposed. It is compared with conventional transfer function analysis. Using the pole placement technique control design automation algorithm, by computer-based tool is presented. Control design example with large signal simulation is shown.

  • PDF

차분 전력 분석 공격의 성능 향상을 위한 전처리 기법 (A Pre-processing Technique for Performance Enhancement of the Differential Power Analysis Attack)

  • 이유석;이유리;이영준;김형남
    • 정보보호학회논문지
    • /
    • 제20권4호
    • /
    • pp.109-115
    • /
    • 2010
  • 차분 전력 분석(Differential Power Analysis, DPA) 기법은 암호화 과정 중 발생하는 누설정보를 이용하는 효과적인 부채널 공격(side-channel attack, SCA) 종의 하나로 알려져 있다. 그러나 공격에 사용되는 누설 전력 신호에는 암호화와 관련이 없는 동작에 의해 야기된 전력 신호가 함께 포함되어 있으며, 이로 인해 공격의 효율성이 크게 저하된다. 따라서 본 논문에서는 차분 전력 분석 기법의 공격 성능을 향상시키기 위해, 측정된 전력 신호로부터 암호화 과정에 관련된 부분만을 추출하는 전처리 방법을 제안한다. 모의실험 결과를 통해 제안된 전처리 방법을 적용한 차분 전력 분석 공격은 기존의 차분 전력 분석 공격에 비해 매우 적은 수의 누설 전력 신호만으로도 암호화 알고리즘에 사용된 비밀 키를 찾을 수 있음을 보인다.

객체지향기법을 이용한 전력조류계산 및 스파시티 연구 (Load flow analysis and sparsity study using object-oriented programming technique)

  • 김정년;백영식
    • 대한전기학회논문지
    • /
    • 제45권3호
    • /
    • pp.329-334
    • /
    • 1996
  • Power system is becoming more and more complex and large Existing procedural programming technique can't cope with software flexibility and maintenance problems. So, Object-Oriented Programming (OOP) is increasingly used to solve these problems. OOP in power system analysis field has been greatly developed. This paper applies OOP in power flow analysis, and presents new algorithm which uses only a Jacobian to solve mismatch equations, and introduces a new sparse matrix storage method which is different from existing method. (author). 11 refs., 12 figs., 3 tabs.

  • PDF

An Improved Detection Technique for Voltage Sag using the Wavelet Transform

  • Kim, Chul-Hwan;Lee, Jong-Po;Ahn, Sang-Pil;Kim, Byung-Chun
    • KIEE International Transactions on Power Engineering
    • /
    • 제11A권4호
    • /
    • pp.1-8
    • /
    • 2001
  • This paper presents a discrete wavelet transform approach for detecting voltage sags initialized by fault conditions and starting of larger motors. The proposed technique is based on utilizing the summation value of D1(at scale 1) coefficients in multiresolution analysis(MRA) based on the discrete wavelet transform. In this paper, the proposed technique is tested under various cases of voltage sags. It is shown that the voltage sag detection technique based on the wavelet transform is a satisfactory and reliable method for detecting voltage sags in power quality disturbance analysis.

  • PDF

여자시스템 제어 및 진단기법 개발 (The Development of Control & Diagnostic Technique for Digital Excitation System)

  • 신만수;류호선;이주현;임익헌;김봉석;송성일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 D
    • /
    • pp.2597-2599
    • /
    • 2005
  • This research is developing the technique of troubleshooting in digital excitation system of nuclear power plant. and the design technique of excitation system is thought to be advanced through this research. Especially, the development of simulator enables to accumulate digital control technique, more analysis for excitation system algorithm. etc helps to develop other nuclear power plants.

  • PDF

Stabilizing Control of DC/DC Buck Converters with Constant Power Loads in Continuous Conduction and Discontinuous Conduction Modes Using Digital Power Alignment Technique

  • Khaligh Alireza;Emadi Ali
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권1호
    • /
    • pp.63-72
    • /
    • 2006
  • The purpose of this raper is to address the negative impedance instability in DC/DC converters. We present the negative impedance instability of PWM DC/DC converters loaded by constant power loads (CPLs). An approach to design digital controllers for DC/DC converters Is presented. The proposed method, called Power Alignment control technique, is applied to DC/DC step-down choppers operating in continuous conduction or discontinuous conduction modes with CPLs. This approach uses two predefined state variables instead of conventional pulse width modulation (PWM) to regulate the output voltage. A comparator compares actual output voltage with the reference and then switches between the appropriate states. It needs few logic gates and comparators to be implemented thus, making it extremely simple and easy to develop using a low-cost application specific integrated circuit (ASIC) for converters with CPLs. Furthermore, stability of the proposed controllers using the small signal analysis as well as the second theorem of Lyapunov is verified. Finally, simulation and analytical results are presented to describe and verify the proposed technique.

Study on the Power Consumption Characteristics of Korean Domestic Species in Peripheral Milling with Image Analysis Technique

  • Lee, Hyoung Woo;Kim, Byung Nam;Kim, Kyung Yong
    • Journal of the Korean Wood Science and Technology
    • /
    • 제33권5호통권133호
    • /
    • pp.38-44
    • /
    • 2005
  • Peripheral milling is one of the most important wood machining processes in wood industry. Power consumption characteristics of twelve Korean domestic species in peripheral milling were investigated in this study. Image analysis technique was applied to extract proper data from the power consumption profiles. Average power consumption increased as cutting depth increased and specific cutting power decreased as cutting depth increased. However, no significant relationship could be found between density and power consumption and between cutting depth and surface roughness.

임베디드 소프트웨어 전력분석기법의 조사분석을 통한 특성 모델 도출 및 활용 (Extracting and Applying a Characteristic Model with Survey of Power Analysis Techniques for Embedded Software)

  • 김종필;김두환;홍장의
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제36권5호
    • /
    • pp.376-385
    • /
    • 2009
  • 그린 IT의 중요성이 부각되면서 저전력의 소프트웨어 개발에 대한 요구사항이 증가하고 있다. 본 논문에서는 임베디드 소프트웨어 개발과정에서 사용되는 기존의 전력분석기법들을 살펴보고, 이들 기법이 제공하는 분석 접근방법의 특성을 추출하였다. 이들 특성을 분류하고 체계화하여 전력분석기법에 대한 특성 모델(characteristic model)을 제안하였다. 제안한 특성 모델을 임베디드 소프트웨어 개발단계와 매핑하여 단계별 전력분석의 주안점이 무엇인가를 살펴보고, 이들이 갖는 의미를 스파이더 다이어그램을 이용하여 해석하였다. 본 연구는 임베디드 소프트웨어의 전력분석 기법에 대한 이해를 높이고, 분석방법의 선택에 대한 가이드라인을 제공할 뿐만 아니라 향후 전력분석을 위한 적용 기술의 변화를 예측할 수 있도록 하는 장점을 제공할 것으로 보인다.