• Title/Summary/Keyword: Power Amp

Search Result 202, Processing Time 0.033 seconds

Severe Accident Analysis for Wolsung Nuclear Power Plants

  • Kwon, Jong-Jooh;Kim, Myung-Ki;Park, Byoung-Chul;Kim, Inn-Seock;Hong, Sung-Yull
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.464-470
    • /
    • 1997
  • Severe accident analysis has been performed for the Wolsung nuclear power plants in Korea to investigate severe accident phenomena of CANDU-600 reactors as a part of Level II PSA study. The accident sequence analyzed in this paper is loss of active heat sinks(LOAH) which is caused by loss of off-site power, diesel generators, and DC power. ISAAC (Integrated Severe Accident Analysis Code)computer code developed by KAERI (Korea Atomic Energy Research Institute) was used in this analysis. This paper describes the important thermal-hydraulics and source term behaviors in the primary system and inside containment, and the failure mechanism of calandria vessel and containment. In addition, some insights for accident management program(AMP) are also given.

  • PDF

The Operational Characteristics of CO2 5 ton/day Absorptive Separation Pilot Plant (이산화탄소 5 ton/day 흡수분리 Pilot Plant 운전 특성)

  • O, Min-Gyu;Park, So-Jin;Han, Keun-Hee;Lee, Jong-Seop;Min, Byoung-Moo
    • Korean Chemical Engineering Research
    • /
    • v.50 no.1
    • /
    • pp.128-134
    • /
    • 2012
  • The pilot scale experiments can handle the flue gas up to 1,000 $Nm^3/hr$ for separation of carbon dioxide included in real flue gas at coal-fired power plant. The operational characteristics was analyzed with the main experimental variables such as flue gas flow rate, absorbent circulation rate using chemical absorbents mono-ethanolamine( MEA) and 2-amino-2-methyl-1-propanol(AMP). The more flue gas flow rate decreased in 100 $m^3/hr$ in the MEA 20 wt% experiments, the more carbon dioxide removal efficiency was increased 6.7% on average. Carbon dioxide removal efficiency was increased approximately 2.8% according to raise of the 1,000 kg/hr absorbent circulation rate. It also was more than 90% at $110^{\circ}C$ of re-boiler temperature. Carbon dioxide removal efficiency of the MEA was higher than that of the AMP. In the MEA(20 wt%) experiment, carbon dioxide removal efficiency(85.5%) was 10% higher than result(75.5%) of ASPEN plus simulation.

A Study for Improving the Power Factor of Distribution Transformer using Condenser Control Circuit (콘덴서 제어회로를 이용한 배전용 변압기의 역률 개선에 관한 연구)

  • Lee, Kwang-Jeek
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.4
    • /
    • pp.21-28
    • /
    • 2014
  • Daily use characteristics of apparent power supplied to distribution transformer can be separated into two different time zone of waking hours and sleeping hours. In sleeping hours, using amount of power is decreasing. The actual curve of power seemed to be quite similar to this kind of separation. Inserting a condenser into a circuit in each different time zone led to maximize power factor of the transformer. The compensating condenser's on/off time is controlled by hysteresis circuit utilizing op amp and power factor of the transformer was improved from 0.945 to 0.999. As a result, the average of current reduction was 2.53A per hour of transformer.

On a Posture Control of Human Robot Master Arm

  • Moon, Jin-Soo;Kim, Cheul-U
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.9
    • /
    • pp.24-31
    • /
    • 2006
  • This study developed a human robot mast arm, which has a structure similar to the human arm, with the objective of taking over human works. The robot arm was structured to reproduce human actions using three axes on each of the shoulder and the wrist based on mechanics, and the actuator of each axis adopted an ordinary DC motor. The servo system of the actuator is a one body type employing an amp for electric power, and it was designed to be small and lightweight for easy installation. We examined the posture control characteristics of the developed robot mast arm in order to test its interlocking, continuous motions and reliability.

Design of CMOS Op Amps Using Adaptive Modeling of Transistor Parameters

  • Yu, Sang-Dae
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.1
    • /
    • pp.75-87
    • /
    • 2012
  • A design paradigm using sequential geometric programming is presented to accurately design CMOS op amps with BSIM3. It is based on new adaptive modeling of transistor parameters through the operating point simulation. This has low modeling cost as well as great simplicity and high accuracy. The short-channel dc, high-frequency small-signal, and short-channel noise models are used to characterize the physical behavior of submicron devices. For low-power and low-voltage design, this paradigm is extended to op amps operating in the subthreshold region. Since the biasing and modeling errors are less than 0.25%, the characteristics of the op amps well match simulation results. In addition, small dependency of design results on initial values indicates that a designed op amp may be close to the global optimum. Finally, the design paradigm is illustrated by optimizing CMOS op amps with accurate transfer function.

A 8-bit Variable Gain Single-slope ADC for CMOS Image Sensor

  • Park, Soo-Yang;Son, Sang-Hee;Chung, Won-Sup
    • Journal of IKEEE
    • /
    • v.11 no.1 s.20
    • /
    • pp.38-45
    • /
    • 2007
  • A new 8-bit single-slope ADC using analog RAMP generator with digitally controllable dynamic range has been proposed and simulated for column level or per-pixel CMOS image sensor application. The conversion gain of ADC can he controlled easily by using frequency divider with digitally controllable diviber ratio, coarse/fine RAMP with class-AB op-amp, resistor strings, decoder, comparator, and etc. The chip area and power consumption can be decreased by simplified analog circuits and passive components. Proposed frequency divider has been implemented and verified with 0.65um, 2-poly, 2-metal standard CMOS process. And the functional verification has been simulated and accomplished in a 0.35$\mu$m standard CMOS process.

  • PDF

A Rail-to-Rail CMOS Op-amp with Constant Gain by Using Output Common Mode Current Compensation (출력 단 공통모드 전류 보상으로 일정한 이득을 갖는 Rail-to-Rail CMOS 연산증폭기)

  • Lee, Dong-Geon;Jeong, Hang-Geun
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.457-458
    • /
    • 2008
  • This paper presents an output common mode current compensation method to achieve both constant Gm and constant gain. A conventional rail-to-rail CMOS op-amp with constant Gm was designed by using complementary differential input stage and current compensation skills. But it doesn't operate constant gain, because of output resistance variation. With $0.18{\mu}m$ CMOS process, the simulation results show that the differential gain variation can achieve less than 1.3dB. And a 60dB gain, a 13.5MHz unity gain-frequency, and 1mW power consumption, when operating at 1.8V and 10pF load.

  • PDF

Novel Switching Pattern for the Paralleling of SRM Inverter (SRM 인버터의 병렬 스위칭을 위한 새로운 스위칭 패턴)

  • Lee S. H.;Lee S. H.;Jung S. W.;Lim H. H.;Park S. J.;Ahn J. W.
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.313-316
    • /
    • 2002
  • A SRM inverter has very low switching frequency. This results in reducing the burden for a high-speed of the gate-amp interface circuit. and the linearity of optocoupler is used to protect the intanteneous peak current for the stable operation In this paper, series resistor is used to equal the current sharing of each switching device and a linear gate-amp is proposed to protect the intanteneous peak current which occurs in transient state.

  • PDF

A Study on the 300MHz NMR Transceiver (300MHz급 NMR Transceiver 설계 및 제작)

  • Park, Yang-Ha;Jin, Seung-Oh;Won, Jin-Im;Huh, Young
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3210-3212
    • /
    • 2000
  • We designed and manufactured 300MHz NMR RF Transceiver. NMR system is composed of NMR Spectrometer, Superconductive Magnet and Pulse Programmer, GUI. NMR RF Transceiver is composed of transmitter, receiver, frequency synthesizer. T/R switch, main power amp., RF coil. To phase modulation, transmitter is composed of mixer, splitter and combiner et al. To weak signal detection, receiver is composed of pre-amp., filter, mixer et al. Each module is manufactured PCB. And installed NMR system to detect chemical component of specimen. In result, we can get the information of specimen.

  • PDF

A Development of 2W-RF Power Amplifier for the End-of-Train Monitoring System (열차 후부 감시제어 시스템용 2W급 RF 전력증폭기 개발)

  • Ahn, Hoon;Kang, Byeong-Gwon;Kim, Sun-Hyung
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.12a
    • /
    • pp.237-240
    • /
    • 2000
  • 본 논문에서는 ISM(Industrial Scientific Medical) 대역 424MHz부터 429MHz까지의 범위에서 동작하는 열차 후부 감시제어 시스템용 RF 전력증폭기를 설계 및 제작하였다. 424MHz대역에서의 2W급 대전력 증폭기의 설계방법으로는 Double Stub Tuner구조를 이용하여 최적 부하 임피던스를 추출하는 방법을 제시하였고, 초고주파 시뮬레이터인 Serenade8.0을 사용하여 Drive_amp와 LPF를 설계하였다. 제작된 Drive_amp와 LPF의 성능 및 특성은 시뮬레이션 한 결과와 거의 일치하였으며, 대전력 증폭기의 측정결과로는 추출하고자 하는 출력 레벨인 33㏈m을 얻을 누 있었고, 원신호의 Hamonic 주파수 성분과는 40.34㏈c의 결과를 보임으로써 안정된 전력증폭기를 구현하였다.

  • PDF