• 제목/요약/키워드: Power/ground

검색결과 1,873건 처리시간 0.038초

Effects of blast-induced random ground motions on the stochastic behaviour of industrial masonry chimneys

  • Haciefendioglu, Kemal;Soyluk, Kurtulus
    • Structural Engineering and Mechanics
    • /
    • 제43권6호
    • /
    • pp.835-845
    • /
    • 2012
  • This paper focuses on the stochastic response analysis of industrial masonry chimneys to surface blast-induced random ground motions by using a three dimensional finite element model. Underground blasts induce ground shocks on nearby structures. Depending on the distance between the explosion centre and the structure, masonry structures will be subjected to ground motions due to the surface explosions. Blast-induced random ground motions can be defined in terms of the power spectral density function and applied to each support point of the 3D finite element model of the industrial masonry system. In this paper, mainly a parametric study is conducted to estimate the effect of the blast-induced ground motions on the stochastic response of a chimney type masonry structure. With this purpose, different values of charge weight and distance from the charge centre are considered for the analyses of the chimney. The results of the study underline the remarkable effect of the surface blast-induced ground motions on the stochastic behaviour of industrial masonry type chimneys.

PCB에서 Resonance Frequency 영향을 고려한 최적 VIA 수 찾는 Algorithm 구현

  • 이상경;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 춘계학술대회
    • /
    • pp.329-332
    • /
    • 2011
  • 최근 사용하는 정보량의 증가로 인해 디지털 회로가 점점 고속, 소형 집적화를 요구로 인해 인쇄회로 기판 역시 높은 신뢰성과 소형화가 요구되어 지고 있다. 특히 POWER PLAN / GROUND PLAN 간 임피던스 영향, 주파수 영향을 고려하여 GROUND / POWER VIA를 통해 개선하고 있으나 너무 많은 VIA가 사용되어 PCB 제조업체 입장에서는 단가 상승 및 납기 지연, 불량요인이 지속적으로 증가하고 있다. 하여 본 논문에서는 VIA 개체수 최적화를 검증 하기 위하여 정형화된 PCB구조의 기본 Design을 활용하여 POWER PLAN과 GROUND PLAN 사이에 VIA의 특정 개수에서 IMPEDANCE값이 수렴하는 것을 검증하여 최적화된 VIA개수를 찾아 보았다.

  • PDF

TFT-LCD 구동회로에서의 EMI 개선을 위한 Power/Ground Plane 모델링 및 실험적 검증 (Power/Ground Plane Modeling and Experimental Characterization for EMI Improvement in TFT-LCD Driving Circuit)

  • 조강연;나완수;이재훈;이성규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.44-47
    • /
    • 2005
  • This paper presents the efficient plan for the EMI improvement from of TFT-LCD Module. It investigates the frequency characteristics of Power/Ground Plane of TFT-LCD drive circuit PCB concretely. After the frequency characteristics is reviewed, EMI improvement is tried to insert to RC termination between Power/Ground Plane and to shift resonance frequency. It is confirmed by a simulation result and RC Termination which is inserted the point where the resonance characteristics change is necessary. It applied in 19 "SXGA TFT-LCD drive circuits and the EMI improvement verification is described.

  • PDF

주파수영역에서의 접지임피던스에 대한 실증적 연구 (The Experimental Study on the behavior of Ground Impedance in the frequency region)

  • 강지원;정길조;정재기;양병모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.155-157
    • /
    • 1997
  • This paper presents the results of an experimental investigation of ground impedance in the low frequency region regarding the transiant state on the soil and ground electrodes(rod, electric rod with needles, electric mesh). The grounding resistance playing an important part in substation grounding designs is measured. Especially, the reduction effect of ground impedance by using the electric rod with needles in the soils are presented.

  • PDF

Investigation of the effects of common and separate ground systems in wireless power transfer

  • Park, Woocheon;Moon, Jung-Ick;Cho, In-kui
    • ETRI Journal
    • /
    • 제44권2호
    • /
    • pp.339-345
    • /
    • 2022
  • This article presents an investigation of the effects on a grounding system of wireless power transfer (WPT) when transmitting over relatively far distances, that is, up to 1.25 m. Conventional two-coil WPT systems are sufficiently commercialized in strong coupling range, but it is important to accomplish the long-range WPT in weak coupling range for further various applications. This system depends on the coupling effect between the two coils that the grounds of the transmitting and receiving coils should be completely separated. However, when evaluating the performance of two-coil systems with the instrument consisting of two ports and one common ground, undesirable problems occur in weak coupling ranges, for example, obtaining disagreeable transmission efficiency and degrading system stability/reliability. We investigate the problems of the leakage power from common ground systems and provide a practical solution to obtain a reliable WPT system by using an isolation transformer. The usefulness of this approach is that it is possible to achieve the stability of the system with relatively far transmitting distances and to determine the exact transmission efficiency.

선택지락보호계전기 오.부동작에 관한 연구 (Study on the Ground Fault Protection in 6.6KV Ungrounded Power System SGR Malfunction or Non-Tripping)

  • 김병태;이달우;전명수
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.296-301
    • /
    • 2008
  • This paper presents a study on the ground fault protection in 6.6KV ungrounded power system relay(SGR) malfunction or non-tripping. Ground test had made on 6.6KV HV(high voltage) system, Some of domestic and oversea's SGR products are different from their own specific characteristics. This study on the ground protection relay 6.6KV power supply system is focused to protect human.

Nonstationary Random Process를 이용한 인공지진파 발생 -설계응답스펙트럼에 의한 파워스펙트럼의 조정- (Generation of Artificial Earthquake Ground Motions using Nonstationary Random Process-Modification of Power Spectrum Compatible with Design Response Spectrum-)

  • 김승훈
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.61-68
    • /
    • 1999
  • In the nonlinear dynamic structural analysis the given ground excitation as an input should be well defined. Because of the lack of recorded accelerograms in Korea it is required to generate an artificial earthquake by a stochastic model of ground excitation with various dynamic properties rather than recorded accelerograms. It is well known that earthquake motions are generally non-stationary with time-varying intensity and frequency content. Many researchers have proposed non-stationary random process models. Yeh and Wen (1990) proposed a non-stationary modulation function and a power spectral density function to describe such non-stationary characteristics. Satio and Wen(1994) proposed a non-stationary stochastic process model to generate earthquake ground motions which are compatible with design reponse spectrum at sites in Japan. this paper shows the process to modify power spectrum compatible with target design response spectrum for generating of nonstationary artificial earthquake ground motions. Target reponse spectrum is chosen by ATC14 to calibrate the response spectrum according to a give recurrence period.

  • PDF

다중접지계통의 접지저항 및 누설전류 자동측정장치 개발 (Development of a new Ground Resistance Tester for Power Electric Poles)

  • 손수국;정영호;최상준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 D
    • /
    • pp.675-678
    • /
    • 2000
  • This paper has proposed a new digital ground resistance tester for electrical systems. It features automatic operation with an injected current source. Without climbing electric power poles a worker can measure safely and quickly a ground resistance and current along the ground line.

  • PDF

저가격 고 신뢰성의 400Hz 전원의 무순단 전력절환용 개선된 동기화 기법 (An Improved Synchronization Control Scheme of a Low Cost 400Hz Power Supply for No-Break Power Transfer)

  • 정석언;현동석
    • 전력전자학회논문지
    • /
    • 제19권5호
    • /
    • pp.470-474
    • /
    • 2014
  • This study proposes an improved synchronization control scheme for a low-cost 400Hz power supply for a no-break power transfer system. In the case of aircraft applications, the 400Hz power supply called ground power units is accepted and used as the external electrical power system during stopovers on ground. A momentary break in the supply occurs when shifting from one power source to another. To allow shifting without a break in the supply, the two power sources are momentarily connected in parallel. The proposed synchronization control is achieved by connecting an existing synchronization bus to the voltage zero-crossing signal of a generator power with discrete logic ICs and analog circuits. Therefore, unlike expensive controllers, such as DSP and CAN, the proposed control scheme is rather simple and may decrease operational cost. The practical feasibility of the proposed control scheme is proven by experimental results.