• Title/Summary/Keyword: Power/ground

Search Result 1,882, Processing Time 0.024 seconds

A Study on Ground Fault Detecting System for DC Voltage Line in the Electric Power Plant (발전소 직류전압 전선로 접지검출시스템에 관한 연구)

  • Lee, H.K.;Kim, N.H.;Park, C.H.;Kim, T.S.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.754-757
    • /
    • 1995
  • This system can detect a ground fault point or a bad insulated line by measuring a power plant DC feeder insulation resistance at the uninterruptible power status. And when the power plant DC feeder with low frequency AC signal has a ground fault, this measuring system can keep recording of its ground fault current and phase checked by Z.C.T. Therefore the power plant could protect a unexpected service interruption.

  • PDF

Analysis of Fire Accidents on Power Line for DC Electric Traction Vehicles (전기철도 전원계통에서의 화재 사고사례 분석)

  • Song, Jae-Yong;Cho, Young-Jin;Kim, Jin-Pyo;Park, Nam-Kyu;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.241-247
    • /
    • 2008
  • This paper describes a cause of fire accidents on power system for DC electric traction vehicles. We investigated fire scene of power line for DC electric traction vehicles. From analysis results, the cause of fire on power line turned out line to ground fault between a feeder of electric power services(pantagraph) and DC electric traction vehicle roof. Fire accidents of DC electric traction vehicles be assumed that electric sparks had been produced between the pantagraph and the power line conductor by repetitively making contact and separation, maybe if some material like branches get in between connecting rod it make progress line to ground fault. ZnO arresters are widely used to protect DC electric traction vehicles against overvoltages caused by lightning or switching surges. However, the arresters are deteriorated by commercial frequency overvoltages and/or lightning one. Deteriorated arresters could lead power failures, such as line to ground fault by a thermal runaway resulting from the increases in leakage current even in a nominal power system voltage. The power failures, such as line to ground fault would be causative of the fire accidents.

  • PDF

Design of the Ground Resistance Measuring System using high Performance Filter System (고성능 필터를 이용한 접지저항 측정시스템의 설계)

  • 이기홍;정재기;주형준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.43-48
    • /
    • 2001
  • This paper represents the design of the ground resistance measuring system insensitive to the noise in the earth. Generally, conventional ground resistance measuring instruments may fail to give a precise values for ground resistance under the situations where there is a high ground potential produced by unbalanced power system currents, haromonic currents and noise etc. To make up the defect of conventional ground resistance measuring instruments, in this paper the ground resistance measuring system using high-performance L-C resonant filter and digital signal processor is designed and the insentivity of the designed ground resistance measuring system for noise in the earth is verified by field test on power service and off power service.

  • PDF

Demonstration of system to combat desertification using renewable energy (신재생에너지를 이용한 사막화 방지 시스템 실증 (몽골))

  • Kim, Man-Il;Lee, Seung-Hun;Whang, Jung-Hun;Cho, Woon-Sic;Park, Moon-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.73-76
    • /
    • 2009
  • Generally, wind or solar power system is operated as a stand-alone power system, the efficiency of which could be higher by designing wind-solar combined system considering average wind speed and solar radiation of the desert region, Mongolia. This system is designed to generate electricity for power users and pumps the ground water for irrigation using deep well pump. The ground water can be used for farming or forestation where there is no or little irrigation system. In connection with this study, a renewable energy park, Green Eco Energy Park, was developed at about 50km east of Ulaanbaatar. 3 sets of 10kW wind power generator and 70 kW of solar power module were installed there. The electricity generated from the system is used to on-site office building and deep well pump for ground water pumping. A 10kW stand-alone solar pumping system, which has no rechargeable battery system, is installed to pump the ground water with the amount of generated power. The ground water is stored in 3 artificial ponds and then it is used for raising nursery tree and farming. The purpose of this study is to provide a possible energy solution to desert regions where there is no or little power system. The system also supply power to ground water pump, and the water can be used for farming and forestation, which will also be a solution of preventing desertification or spreading of desert area.

  • PDF

Transient Overvoltages of Communication Equipment Depending on the Grounding Method of SPD (SPD 접지방식에 따른 통신기기의 과도위험전압)

  • Eom, Ju-Hong;Lee, Tae-Hyung;Cho, Sung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.130-138
    • /
    • 2008
  • The tendency of lightning surge to propagate is a eared variously depend on the power system and subject equipment of protection. However, looking into the subject equipment with the lightning surge, the invasion route of lightning surge can be divided in between the two lines of power, between the power line and the ground, the power line and the PE conductor, between the neutral line and the ground and the like. In addition, in the event of the communication equipment, there exists the route of lightning surge incoming from between the communication lines, the communication line and the ground in addition to the power lines. In this study, the tendency of propagation of lightning surge penetrated on to the subject equipment is analyzed through the empirical experiment in accordance with the ground method by using the independent ground, common ground and bypass arrester ground for safety improvement in power lines.

Wide-Bandwidth Wilkinson Power Divider for Three-Way Output Ports Integrated with Defected Ground Structure

  • Sreyrong Chhit;Jae Bok Lee;Dal Ahn;Youna Jang
    • Journal of information and communication convergence engineering
    • /
    • v.22 no.1
    • /
    • pp.14-22
    • /
    • 2024
  • This study presents the design of a Wilkinson power divider for three-way output ports (WPD3OP), which incorporates a defected ground structure (DGS). An asymmetric power divider is integrated into the output ports of the conventional Wilkinson power divider (WPD), establishing a three-way output port configuration. The DGS introduces periodic or irregular patterns into the ground plane to suppress unwanted electromagnetic wave propagation, and its incorporation can enhance the performance of the power divider, in terms of the power-division ratio, isolation, and bandwidth, by reducing spurious resonances. The proposed design algorithm for an asymmetric power divider for three-way output ports is analyzed via circuit simulations using High-Frequency Simulation Software (HFSS). The results verify the validity of the proposed method. The analysis of the WPD3OP integrated with DGS certifies the achievement of a center frequency of 2 GHz. This confirmation is supported by schematic ideal design simulation results and measurements encompassing insertion losses, return losses, and isolation.

New Ground Fault Protective Relay in DC Traction Power System (비접지 DC 급전계통에서 전류형 지락보호계전기의 사용)

  • Chung S.G.;Baek N.W.;Kim Y.S.;Lee S.H.;Lee H.M.
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1297-1302
    • /
    • 2004
  • In DC power distribution system for urban rail transits potential relay, 64P, is used to detect the ground faults. The problem with this 64P is that though it detects the ground fault it cannot identify the faulted region. Therefore the faulted region cannot be isolated properly. It could results in power loss of the trains on the healthy regions and the safety of the passengers in the trains could be affected adversely. A new ground fault protective relaying scheme that can identify the faulted region is presented in this paper. The new concept uses the current differential scheme and the permissive scheme to identify the faulted region correctly. A device with similar characteristic to the arrestor is adapted to use the current relay for the ground fault detection. The role of the device is to block the ground leakage current in normal operating condition and enable the ground fault current to flow in ground fault condition. The algorithm of the new relay and the effect of the newly adapted device in the new relaying scheme are discussed.

  • PDF

Installation methods of OPGW for 765kV overhead power transmission lines (765kV 가공 송전선로용 OPGW 시설공법)

  • Kwan, Y.G.;Kim, Y.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1641-1643
    • /
    • 1998
  • In recent the maximum voltage of overhead power transmission lines in Korea was upgraded to 765kV. In general a overhead ground wire is installed for protecting overhead power transmission lines from lightning. For the 765kV line, Composite Overhead Ground Wire with Optic Fiber (OPGW) is applied as a overhead ground wire and have a function of the communication line between substations. In this paper, the construction and properties of OPGW, and its installation methods are discribed.

  • PDF

Construction of Marine Small Hydro Power Plant using Discharge Water of Fish Farm (양어장 방류수를 이용한 해양소수력발전소 구축에 관한 연구)

  • Hwang, Yeong-Cheol;Choi, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.5
    • /
    • pp.11-17
    • /
    • 2013
  • This study is aimed to construct a marine small hydro power plant using discharge water of fish farm in Jeju Haengwon-ri. The difference of design methods between marine small hydro power plant and land small hydro power plant is to consider the tides. Moreover, ground condition should be examined because gushout sea water comes out from the ground at high tide in Jeju as the ground of Jeju beach consists of basalt stone. From the field test of the turbine generator after construction of the power plant, output power and efficiency of the turbine generator shows good conformance to the required conditions.

The Study on the Impulse Characteristic of Secondary Arresters in Power Distribution System (가공 배전선로 중성선과 가공지선 겸용시의 임펄스 특성 연구)

  • Kang, Moon-Ho;Kim, Dong-Myeong;Song, Il-Keun;Chun, Sung-Nam
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.297-299
    • /
    • 2004
  • In multi-ground distribution system, overhead ground wire and neutral wire are parallel connected to offer the electrical power energy and protect damage of lightning strokes. Therefore a case where the two wires become single wire, the power company can get the benefit such as installation cost saving and line fault protection by simplify of distribution line. In this paper we describe the result of impulse test in both system ; one is the present power system the other is unified power system parallel connected overhead ground wire and neutral wire. As a result of this impulse test, the present power system get lower impulse voltage than the unified power system.

  • PDF