• 제목/요약/키워드: Powder pressing

검색결과 389건 처리시간 0.025초

저온소결 PMN-PNN-PZT계 세라믹스를 이용한 Rosen형 압전변압기의 전기적 특성 (Electrical Properties of Rosen Type piezoelectric transformers using Low Temperature Sintering PMN-PNN-PZT ceramics)

  • 이상호;류주현;김인성;송재성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.53-53
    • /
    • 2008
  • Piezoelectric transformers have been widely used such as DC-DC convertor, invertor, Ballast, etc. Because, the y have some merits compared with electro-magnetic transformers such as step-up ratio, high efficiency, small size and lg hit weight, etc. Piezoelectric transformer require high electromechanical coupling factor kp in order to induce a large out put power in proportional to applied electric field. And also, high mechanical quality factor Qm is required to prevent mechanical loss and heat generation. In general, PZT system ceramics should be sintered at high temperatures between 1200 and $1300^{\circ}C$ in order to obtain complete densification. Accordingly, environmental pollution due to its PbO evaporation. Hence, to reduce its sintering temperature, various kinds of material processing methods such as hot pressing, high energy mill, liquid phase sintering, and using ultra fine powder have been performed. Among these methods, liquid phase sintering is basically an effective method for aiding densification at low temperature. In this study, In order to comparis on low temperature sintering and solid state sintering piezoelectric transformers, rosen type transformers were fabricated u sing two PZT ceramics compositions and their electrical properties were investigated.

  • PDF

SOFC의 Sr 첨가량에 따른 $La_{1-x}Sr_xCoO_3$ Cathode 재료의 제조 및 특성 연구 (Preparation and Characteristics of $La_{1-x}Sr_xCoO_3$ Cathode material as function of Sr mole fraction in SOFC)

  • 박주홍;엄승욱;문성인;박태곤;윤문수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.202-204
    • /
    • 1994
  • Nowadays Perovskite $La_{1-x}Sr_xCoO_3$ is a preferred cathode material in the construction Solid Oxide Fuel Cell (SOFC). The $La_{1-x}Sr_xCoO_3$ with Sr contents ranging from X=0.0 to X=1.0 were prepared by a citrate method. All samples were examined by X-ray powder diffraction. The samples used for measuring thermal expansion were prepared as pellets by cold pressing and subsequent sintering in air at $1200^{\circ}C$ for 5 hours. To measure the sub-product of $La_{1-x}Sr_xCoO_3$ with YSZ, where coating films were sintered at $1200^{\circ}C$ for 5 hour.

  • PDF

Catalytic growth of single wall carbon nanotubes by laser vaporization and its purification and The carbon nanotube growth on the Si substrate by CVD method

  • Lee, Sung won;Jung in Sohn;Lee, Seonghoon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2000년도 제18회 학술발표회 논문개요집
    • /
    • pp.213-213
    • /
    • 2000
  • Direct laser vaporization of transition-metal(Co, Ni)/graphite composite pellet produced single wall carbon naotubes(SWNT) in the condensing vapor in a heated flow cylinder-type tube furnace, Transition metal/graphite composite pellet target was made by mixing graphite, Co, and Ni in 98:1:1 atomic weight ratios, pressing the mixed powder, and curing it. The target was placed in a tube furnace maintained at 1200$^{\circ}C$ and Ar inert collision gas continuously flowed into the tube. The 2nd harmonic, 532nm wavelength light from Nd-YAG laser was used to vaporize the tube. The carbon nanotubes produced by the laser vaporization were accumulated on quartz tube wall. The raw carbon nanotube materials were purified with surfactants(Triton X-100) in a ultrasonicator. These carbon nanotubes were analyzed using SEM, XRD, and Raman spectroscopic method. The carbon nanotube growth on the Ni-patterned Si substrate was investigated by the CVD process. Transition-metal, Ni and CH4 gas were used as a catalyst and a reactant gas, respectively. The structure and the phonon frequencies of the carbon nanotubes formed on the patterned Si substrate were measured by SEM and Raman spectrometer.

  • PDF

용융탄산염 연료전지 양극용 다공성 cermet 전극제조에 관한 연구 (A study on the fabrication of porous cermet electrode for molten carbonate fuel cell anode)

  • 이규환;장도연;김만;강성군
    • 한국표면공학회지
    • /
    • 제26권6호
    • /
    • pp.291-298
    • /
    • 1993
  • In order to substitute for porous nickel anode in Molten Carbonate Fuel Cell(MCFC), porous cermet elec-trode was fabricated with Ni and Ni-P coated ceramic powder. Ni and Ni-P were coated by electroless plat-ing method in the nickel solution containing of hydrazine and sodium hypophosphate as a reducing agent. The plating solution was stirred by air and mechanical agitator. Ultrasonic irradiation was applied to the plating bath to improved the effect of agitation and coating speed. Electorde was formed by pressing method and doc-tor blade method followed by sinterd at$ 800^{\circ}C$ for 6 hours in H2 environment. Anode performance test carried out by potentiodynamic polarization technique in the MCFC operating condition and 154-161mA/$\textrm{cm}^2$ as ob-tained as a anode current density at the+100mV overpotential.

  • PDF

Design of Multipurpose Phantom for External Audit on Radiotherapy

  • Lim, Sangwook
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.122-129
    • /
    • 2021
  • Purpose: This study aimed to design a multipurpose dose verification phantom for external audits to secure safe and optimal radiation therapy. Methods: In this study, we used International Atomic Energy Agency (IAEA) LiF powder thermoluminescence dosimeter (TLD), which is generally used in the therapeutic radiation dose assurance project. The newly designed multipurpose phantom (MPP) consists of a container filled with water, a TLD holder, and two water-pressing covers. The size of the phantom was designed to be sufficient (30×30×30 cm3). The water container was filled with water and pressed with the cover for normal incidence to be fixed. The surface of the MPP was devised to maintain the same distance from the source at all times, even in the case of oblique incidence regardless of the water level. The MPP was irradiated with 6, 10, and 15 MV photon beams from Varian Linear Accelerator and measured by a 1.25 cm3 ionization chamber to get the correction factors. Monte Carlo (MC) simulation was also used to compare the measurements. Results: The result obtained by MC had a relatively high uncertainty of 1% at the dosimetry point, but it showed a correction factor value of 1.3% at the 5 cm point. The energy dependence was large at 6 MV and small at 15 MV. Various dosimetric parameters for external audits can be performed within an hour. Conclusions: The results allow an objective comparison of the quality assurance (QA) of individual hospitals. Therefore, this can be employed for external audits or QA systems in radiation therapy institutions.

치과용 아말감의 미세경도에 관한 실험적연구 (AN EXPERIMENTAL STUDY ON THE MICROHARDNESS OF DENTAL AMALGAMS)

  • 신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제8권1호
    • /
    • pp.89-96
    • /
    • 1982
  • The purpose of this study is to identify the phases of four different types, low-copper lathe cut (Type II, class 1) and spherical (Type II, class 2) amalgam alloys which are made by Caulk company and high copper Dispersalloy (Type II, class 3) made by Johnson & Johnson and Tytin (Type I, class 2) made by S.S. White and to determine the Vickers hardness number on the individual phase and four different types of dental amalgam. After each amalgam alloy and Hg measured exactly by the balance was triturated by the mechanical amalgamator (De Trey), the triturated mass was inserted into the cylindrical metal mold which was 4 mm in diameter and 12mm in height and was pressed by the Instron Universal Testing machine (Model 1125) at the speed of 1mm/minute with 143$kg/cm^2$ according to the A.D.A. Specification No. 1. The Specimen removed from the mold, mounted and stored in the room temperature for 7 days. The speciman was polished with the emery paper from #220 to #1200 and finally on the polishing cloth with 0.3 and 0.05 um $Al_2O_3$ powder suspended in water. And then each specimen was etched by Allan's method and washed with Sodium Bisulfinite for 30 seconds. Finally differentiation and metallography on each phase were obtained by using metallographical microscope (Versamet, Union) and microhardness was obtained by using microhardness tester (MVH-2, Torsee). The results were as follows: 1. In the low-copper amalgam, the ${\gamma}$, ${\gamma}_1$ and ${\gamma}_2$ phase were observed and in the high-copper amalgam, the ${\gamma}$, ${\gamma}_1$. ${\epsilon}$ and ${\eta}$ phases were observed but ${\gamma}_2$ phase was not observed. 2. Among the microhardness of each amalgam phase measured under pressing a vickers diamond indenter with 2.0gm load for 30 seconds, e phase has the highest V.H.N (314 ${\pm}$ 20), and in low-copper amalgam 12 phase has the lowest V.H.N. (29${\pm}$1) and ${\eta}$ phase which was observed in high-copper amalgam has 230${\pm}$13 V.H.N and this phase is considerd to contribute to strengthen the handness in amalgam. 3. The V.H.N. measured under pressing a Vickers diamond indenter with 300.0gm load for 30 seconds in low-copper amalgam was lower than that of high-copper amalgam.

  • PDF

$Bi_{2}Se_{3}$ 함량에 따른 Bi$_{2}$(Te$_{1-x}$Se$_{ x}$)$_{3}$ (Thermoelectric Properties of the Hot-Pressed Bi$_{2}$(Te$_{1-x}$Se$_{ x}$)$_{3}$ Alloys with the $Bi_{2}Se_{3}$ Content)

  • 김희정;오태성;현도빈
    • 한국재료학회지
    • /
    • 제8권5호
    • /
    • pp.408-412
    • /
    • 1998
  • Bi$_{2}$(Te$_{1-x}$Se$_{ x}$)$_{3}$(0.05$\leq$x$\leq$0.25)합금분말을 기계적 합금화 공정으로 제조하여 가압소결 후, $Bi_{2}$Se$_{3}$함량에 따른 열전특성의 변화거동을 분석하였다. 기계적 합금화로 제조한 $ Bi_{2}$(Te$_{1-x}$ $Se_{x}$$_{3}$ 가압소결체는 단결정과는 달리 donor dopant의 첨가없이도 n형 전도를 나타내었다. $Bi_2(Te_{0.85}Se_{0.15})_3$ 합금분말을 (50%H$_{2}$+50% Ar)분위기 중에서 환원처리하여 가압소결시, 분말 효면의 산화층 제거와 과잉 Te 공격자의 소멸에 기인한 전자 농도의 감소로 p형으로 천이되었다. 기계적 합금화로 제조한 $ Bi_{2}$($Te_{1-x}$ $Se_{x}$$_{3}$가압소결체는 x=0.15조성에서 $1.92{\times}10^{-3}$ K의 최대 성능지수를 나타내었다.

  • PDF

반응밀링법에 의한 Ti-TiC 복합재료의 제조 및 고온 기계적 특성 (Production and High Temperature Mechanical Properties of Ti-TiC Composite by Reaction Milling)

  • 진상복;최철진;이상윤;이준희;김순국
    • 한국재료학회지
    • /
    • 제8권10호
    • /
    • pp.918-924
    • /
    • 1998
  • 본 연구는 티타늄과 활성탄소 원료분말을 반응밀링법에 의해 합성시, 밀링시간에 따른 Ti-TiC 복합재료의 미세조직과 기계적 성질에 미치는 TiC vol.% 및 열간압축성형온도의 영향에 관해 조사하였다. 티타늄과 활성 탄소 원료분말을 300시간 밀링 후 $5\mu\textrm{m}$이하의 미세한 구형의 Ti-TiC복합분말을 생성시킬 수 있었다. 반응밀링된 분말을 $1000^{\circ}C$이상에서 1시간동안 진공열간압축성형한 경우 이론밀도의 98%에 가까운 우수한 성형체를 얻었으며, TiC입자가 티타늄 기지 전반에 걸쳐 고르게 분산되어 Ti-TiC 복합재료의 기계적 특성을 향상시켰다. Ti-TiC복합재료의 고온안정성을 고찰하기 위해 $600^{\circ}C$등온열처리한 결과 80시간까지는 경도의 큰 변화없이 열적으로 안정하였다. Ti-20vol%TiC 복합재료를 $700^{\circ}C$에서 고온압축시험을 한 경우 330MPa의 높은 항복강도값을 나타내었다.

  • PDF

Strip-cast 조건이 Nd-Fe-B 합금의 미세조직 형성에 미치는 영향 (Effect of Strip-cast Conditions on the Formation of Microstructures in Nd-Fe-B alloys)

  • 이대훈;장태석;김동환;김승호
    • 한국자기학회지
    • /
    • 제12권1호
    • /
    • pp.34-40
    • /
    • 2002
  • 고에너지 Nd-Fe-B 소결자석 제조용 strip-cast 합금의 미세조직 개선을 위하여, Nd-Fe-B 합금을 다양한 조건하에서 strip casting법으로 제조한 후, 제조 조건이 상 형성, 상 분포 및 조직 형성에 미치는 영향을 조사하였다. 냉각속도 즉, wheel speed가 5 m/s 이하일 때 고특성 소결자석 제조에 적합한 미세조직을 갖는 Strip 합금들을 제조할 수 있었으며, 이때의 한계 조성은 Nd$_{14}$Fe$_{79}$B$_{7}$ 정도로 추정되었다. 또한 조성에 상관없이 5 m/s 이하에서는 strip 표면에 수직한 방향으로 <001> preferred orientation이 발생하였는데, 이것은 궁극적으로 합금의 분쇄.성형시 결정립 배향도 향상에 유리하게 작용할 것으로 보인다. 한편 냉각속도가 증가할수록 Nd$_2$Fe$_{14}$B 결정립의 미세화로 인하여 보자력이 증가하였으나, Nd 함량이 감소할 경우 $\alpha$-Fe 정출의 증가로 인하여 보자력이 감소하였다.

Processing and Mechanical Properties of Mullite Fiber / Fe Composite

  • Niibo, Yoshihide;Yuchi, Kazuhiro;Sameshima, Soichiro;Hirata, Yoshihiro
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 2000년도 Proceedings of 2000 International Nano Crystals/Ceramics Forum and International Symposium on Intermaterials
    • /
    • pp.195-214
    • /
    • 2000
  • The high-speed steel (shorten as HSS) consists of Fe and several kinds of transition metal carbides. The cutting tools or wear-resistant materials made from HSS experience relatively high thermal shock because a coolant such as water or oil is flowed over the surface of heated HSS. The purpose of this research is to increase the hardness, strength, fracture toughness and thermal shock resistance of HSS. A possible strategy is to incorporate a hard ceramic material with high strength in HSS matrix. This paper describes the processing, microstructure and mechanical properties of the oriented unidirectional mullite fiber/HSS composite. The unidirectional mullite fibers of 10${\mu}{\textrm}{m}$ diameter were dispersed by the ultrasonic irradiation of 38 kHz in an ethylenglycol suspension containing HSS powder of 11${\mu}{\textrm}{m}$ median size. The dried green composites with 4-68 vol% fibers were hot-pressed for 2h at 100$0^{\circ}C$ in Ar atmosphere under a pressure of 39 MPa. The higher density was achieved in the composite with a lower content of fibers. The oriented unidirectional fibers were well dispersed in the HSS matrix. The average distance between the center of fibers in the cross section was close to the value calculated from the fiber fraction. No reaction occurred at the interfaces between HSS and mullite fibers in the composites. The composite with 13.6 vol% fibers showed 100 MPa of four point flexural strength at room temperature. The thermal expansion of composite with heating was influenced by the orientation of mullite fibers.

  • PDF