• Title/Summary/Keyword: Potentiodynamic polarization

Search Result 292, Processing Time 0.019 seconds

Affect of Corrosion Potential and Current Density on Polarization Curves Variations of Polyvinylchloride[II]

  • Park, Chil-Nam;Yang, Hyo-Kyung;Kim, Sun-Kyu
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.3 no.3
    • /
    • pp.159-167
    • /
    • 1999
  • This study performed experiments for measuring corrosion potential and current density variations in the polarzation curves of polyvinylchloride. The results were examined to identify particular influences affectingthe corrosion potential such as temperature, pH, enzyme, and salt. The lines representing active anodic dissolution were only slightly shifted in the potential direction by temperature, pH, enzyme and salt. The Tafel slope for the anodic dissolution was determined using the polarization effect with varying conditions. The slope of the polarization curves describing the active-to-passive transition region was noticeably shifted in the potential direction. In addition, using the variation in conditions, the best temperature and pH were determined for the corrosion rate, and resistance of corrosion. The second anodic current density peak and maximum passive current density were designated as degraded(IP/I0). The value of IP/I0 was used in measuring the extent of the degradation of the polyvinychloride. The potentiodynamic parameters of the corrosion were obtained using a Tafel plot.

  • PDF

Influence of Redox Potential Current Density on Polarization Curves with Polypropylene Polymer

  • Park, Chil-Nam;Kim, Myung-Sun
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.4
    • /
    • pp.255-261
    • /
    • 2000
  • Experiments were carried out to measure the corrosion potential and current density variations in the polarization curves of polypropylene. In particular, the results were examined to identify those influences affecting the corrosion potential, such as temperature, pH, salt, and oxygen. The Tafel slope for the anodic dissolution was determined based on the polarization effect under various conditions. Furthermore, the optimum conditions for the most rapid transformation were establish based on a variety of conditions, including temperature, pH, corrosion rate, and resistance of corrosion potential. The second anodic current density peak and maximum passive current density were designated as the critical corrosion sensitivity(I(sub)r/I(sub)f). This I(sub)r/I(sub)f value was then used to measure the critical corrosion sensitivity of polypropylene. The potentiodynamic parameters of corrosion were obtained using a Tafel plot.

  • PDF

Electrochemical Corrosion Properties of Amorphous Co-Nb-B Alloys Prepared by Melt-Spinning Method (액체급냉법에 의해 제조한 비정질 Co-Nb-B 합금의 전기화학적 부식 특성)

  • Kim, Eun-Sun;Kim, Hyun-Goo;Jang, HeeJin
    • Corrosion Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.152-156
    • /
    • 2014
  • This study was undertaken to examine the electrochemical corrosion properties of an $Co_{80}Nb_{10}B_{10}$ and $Co_{82}Nb_8B_{10}$ amorphous alloys prepared by melt-spinning method under various conditions. The potentiodynamic polarization responses at various levels of pH (pH 2, pH 7, pH 12) showed that the corrosion current rate of $Co_{80}Nb_{10}B_{10}$ alloy is lower than that of $Co_{82}Nb_8B_{10}$ alloy in all levels of pH, implying the general corrosion resistance of the alloy with higher Nb content is better than that with higher Co content. The pitting potential of $Co_{80}Nb_{10}B_{10}$ alloy was also better than that of $Co_{82}Nb_8B_{10}$, evidenced by the higher pitting potential. Nb is thought to be effective in increasing the protectiveness of the passive film and hence to improve the corrosion resistance of Co-Nb-B alloys.

Analysis of PVDF Coating Properties with Addition of Hydrophobically Modified Fumed Silica

  • Lee, Nam Kyu;Kim, Young Hoon;Im, Tae Gyu;Lee, Dong Uk;Shon, MinYoung;Moon, Myung Jun
    • Corrosion Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.232-242
    • /
    • 2019
  • In this study, hydrophobically modified fumed silica was added to the PVDF coating to improve corrosion protection performance. Two types of silane modifiers, trimethylchlorosilane (TMCS) and hexamethyldisilazane (HMDZ), were used for hydrophobic modification of the fumed silica. The composition of modified fumed silica was analyzed by Fourier transform infrared, X-ray photoelectron spectroscopy, and elemental analysis. The dispersion of modified fumed silica in the PVDF coating was observed by the transmission electron microscopy, and the hydrophobicity of PVDF coating was analyzed by the water contact angle. Surface properties were examined by the field emission scanning electron microscopy and scanning probe microscopy. Potentiodynamic polarization was conducted to confirm corrosion protection performance of PVDF coating in terms of hydrophobically-modified fumed silica contents. As a result, the average surface roughness and the water contact angle of the PVDF coating increased with modifier contents. The results of the potentiodynamic polarization test showed an increase of the Ecorr values with increase of the hydrophobicity of PVDF coating. Thus, it clearly indicates that the corrosion protection performance of PVDF coating improved with the addition of the hydrophobic-modified fumed silica that prevents the penetration of moisture into the PVDF coating.

Effect of Si on the Corrosion Properties of Mg-Li-Al Light Alloy (경량화 Mg-Li-Al합금의 내식성에 미치는 Si의 영향)

  • 김순호
    • Resources Recycling
    • /
    • v.7 no.5
    • /
    • pp.52-57
    • /
    • 1998
  • Effect of Si in the electrochemical corrosion characteristics of Mg-Li-Al light alloy has been investigated by means of potentiodynamic polarization study. The elecrochemical behaviors were evaluated in 003% NaCl solution and the solution buffered with KH$_{2}PO_{5}{\cdot}$NaOH at room temperature. It was found that the addition of very small quantity of Si (0.48 wt%) in Mg-Li-Al light alloy increased corrosion rates and amount of corrosion products and decreated the pitting resistance of the alloy. From the results it was concluded that Si which is added to increase the strength of Mg-Li-Al alloy is harmful to corrosion properties of the alloy.

  • PDF

Electrochemical Corrosion and Chemical Mechanical Polishing(CMP) Characteristics of Tungsten Film using Mixed Oxidizer (혼합 산화제를 사용한 텅스텐 막의 전기화학적 부식 및 CMP 특성)

  • Na, Eun-Young;Seo, Yong-Jin;Lee, Woo-Sun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.4
    • /
    • pp.303-308
    • /
    • 2005
  • In this paper, the effects of oxidants on tungsten chemical mechanical polishing (CMP) process were investigated using three different oxidizers such as Fe(NO₃)₃, KIO₃ and H₂O₂. Moreover, the interaction between the tungsten film and the oxidizer was discussed by potentiodynamic polarization measurement with three different oxidizers, in order to compare the effects of W-CMP and electrochemical characteristics on the tungsten film as a function of oxidizer. As an experimental result, the tungsten removal rate reached a maximum at 5 wt% Fe(NO₃)₃concentration, and when 5 wt% H₂O₂was added in the slurry, the removal rate of W increased. Also, the microstructures of surface layer by atomic force microscopy(AFM) image were greatly influenced by the slurry chemical composition of oxidizers. It was shown that the surface roughness and removal rate of the polished surface were improved in Fe(NO₃)₃than KIO₃. The electrochemical results indicate that the corrosion current density of the 5 wt% H₂O₂ and 5 wt% H₂O/sub 2+/+ 5 wt% Fe(NO₃)₃was higher than the other oxidizers. Therefore, we conclude that the W-CMP characteristics are strongly dependent on the kinds of oxidizers and the amounts of oxidizer additive.

Effect of β-Blocker Inhibitors on Aluminum Corrosion (알루미늄 부식에 대한 베타-차단제 억제제 효과)

  • Fouda, A. S.;El-Ewady, G. Y.;Shalabi, K.
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.2
    • /
    • pp.268-278
    • /
    • 2011
  • Corrosion of aluminum in 0.1 M HCl solution in the absence and presence of ${\beta}$-blocker inhibitors (atenolol, propranolol, timolol and nadolol) was investigated using weight loss, potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) techniques. The inhibition efficiency increased with inhibitor concentration and decreased with rise of temperature. Potentiodynamic polarization curves revealed that they acted as cathodic inhibitors. Some thermodynamic parameters were calculated and discussed. All inhibitors were adsorbed on Al surface obeying Frumkin isotherm. All EIS tests exhibited one capacitive loop which indicates that the corrosion reaction is controlled by charge transfer process. The inhibition efficiencies of all test methods were in good agreement.

Ginger Extract as Green Corrosion Inhibitor for Steel in Sulfide Polluted Salt Water

  • Fouda, Abd El-Aziz S.;Nazeer, Ahmed Abdel;Ibrahim, Mohamed;Fakih, Mohamed
    • Journal of the Korean Chemical Society
    • /
    • v.57 no.2
    • /
    • pp.272-278
    • /
    • 2013
  • Extract of ginger has been evaluated as a green inhibitor for the corrosion of steel in sulfide polluted NaCl solution using potentiodynamic polarization, electrochemical impedance spectroscopy (EIS) and electrochemical frequency modulation (EFM) techniques. Potentiodynamic polarization measurements showed that this extract acts as a mixed type inhibitor but mainly inhibits the cathodic reaction. The inhibition efficiency was found to increase with inhibitor concentration reaching to approximately 83.9% using 250 ppm of ginger. Nyquist plots show a single capacitive loop in uninhibited and inhibited solutions. From EFM the causality factors are very close to theoretical values which indicate that the measured data are of good quality. The adsorption process of the studied extract on steel surface obeys Temkin adsorption isotherm. The results obtained from the different electrochemical techniques were in good agreement which prove the validity of these tools in measurement of corrosion rate. Ginger extract has no effect on Escherichia Coli and can be applied safely on waste water treatment plants.

Electrochemical Evaluation of Si-Incorporated Diamond-Like Carbon (DLC) Coatings Deposited on STS 316L and Ti Alloy for Biomedical Applications

  • Kim, Jung-Gu;Lee, Kwang-Ryeol;Kim, Young-Sik;Hwang, Woon-Suk
    • Corrosion Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.18-23
    • /
    • 2007
  • DLC coatings have been deposited onto substrate of STS 316L and Ti alloy using r.f. PACVD (plasma-assisted chemical vapor deposition) with a mixture of $C_{6}H_{6}$ and $SiH_{4}$ as the process gases. Corrosion performance of DLC coatings was investigated by electrochemical techniques (potentiodynamic polarization test and electrochemical impedance spectroscopy) and surface analysis (scanning electron microscopy). The electrolyte used in this test was a 0.89% NaCl solution of pH 7.4 at temperature $37^{\circ}C$. The porosity and protective efficiency of DLC coatings were obtained using potentiodynamic polarization test. Moreover, the delamination area and volume fraction of water uptake of DLC coatings as a function of immersion time were calculated using electrochemical impedance spectroscopy. This study provides the reliable and quantitative data for assessment of the effect of substrate on corrosion performance of Si-DLC coatings. The results showed that Si-DLC coating on Ti alloy could improve corrosion resistance more than that on STS 316L in the simulated body fluid environment. This could be attributed to the formation of a dense and low-porosity coating, which impedes the penetration of water and ions.

A Study of Localized Corrosion Mechanisms in the Multilayered Coatings by Cathodic Arc Deposition (음극아크증착법으로 합성한 다층박막의 국부부식 기구에 관한 연구)

  • 김호건;안승호;이정호;김정구;한전건
    • Journal of the Korean institute of surface engineering
    • /
    • v.36 no.4
    • /
    • pp.301-306
    • /
    • 2003
  • Multilayered WC-Ti/suv $1-x/Al_{x}$ N coatings were deposited on AISI D2 steel using cathodic arc deposition (CAD) method. These coatings contain structural defects such as pores or droplets. Thus, the substrate is not completely isolated from the corrosive environment. The growth defects (pores, pinholes) in the coatings are detrimental to corrosion resistance of the coatings used in severe corrosion environments. The localized corrosion behavior of the coatings was studied in deaerated 3.5 wt.% NaCl solution using electrochemical techniques (potentiodynamic polarization test) and surface analyses (GDOES, SEM, AES, TEM). The porosity was calculated from the result of potentiodynamic polarization test of the uncoated and coated specimens. The calculated porosity is higher in the $WC-Ti_{0.6}$ $Al_{0.4}$ N than others, which is closely related to the packing factor. The positive effects of greater packing factor act on inhibiting the passage of the corrosive electrolyte to the substrate and lowering the localized corrosion kinetics. From the electrochemical tests and surface analyses, the major corrosion mechanisms can be classified into two basic categories: localized corrosion and galvanic corrosion.