• Title/Summary/Keyword: Potential Rise

Search Result 666, Processing Time 0.026 seconds

Research on Assessment of Potential Interference between Individual Grounding Electrodes Using an Electrolytic Tank Modeling Method

  • Gil, Hyoung-Jun;Kim, Dong-Ook;Choi, Chung-Seog
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.3
    • /
    • pp.27-33
    • /
    • 2008
  • This paper deals with the assessment of potential interference between individual grounding electrodes using an Electrolytic Tank Modeling method. When a test current was passed through a grounding electrode, potential rise was measured and analyzed using an electrolytic tank in real time. In order to analyze the potential interference between grounding electrodes, a reduced scale modeling method was studied. Potential interference between isolated grounding electrodes was evaluated as a function of the separation distance between grounding electrodes and the configuration of grounding electrode to be induced. It was found that the separation distance between grounding electrodes was a major factor in reducing the potential interference.

Characteristics of Potential Gradient for the Type of Structure Grounding Electrode (구조체 접지전극의 유형에 따른 전위경도 특성)

  • Gil Hyung-Jun;Choi Chun-Seog;Kim Hyang-Kon;Lee Bok-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.8
    • /
    • pp.371-377
    • /
    • 2005
  • This paper Presents the Potential gradient characteristics of structure grounding electrode when a test current flows through grounding electrode. In order to analyze the potential gradient of ground surface on structure grounding electrode, the reduced scale model has been used. The potential gradient has been measured and analyzed for types of structure using the hemispherical grounding simulation system in real time. The structures were designed through reducing real buildings and fabricated with four types on a scale of one-one hundred sixty. The supporter was made to put up with weight of structure and could move into vertical, horizontal, rotary direction. When a test current flowed through structure grounding electrodes, ground potential rise was the lowest value at electric cage type(type B). According to resistivity and absorption percentage In concrete attached to structure, the potential distribution of ground surface appeared differently.

Effective Installation Methods of Down Conductors in Lightning Protection Systems (뇌보호시스템에서 인하도선의 효과적인 설치기법)

  • 이복희;엄주홍;이승칠;강성만
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.8-14
    • /
    • 2002
  • A modern lightning protection system is required to eliminate the risks such as electrical shocks and damages of structures, electrical and electronic equipments due to lightning. However, the conventional lightning protection systems play and important role in protecting persons and structures only. Thus an effective lightning protection system is indispensable today in computer, information and communication facilities and etc. The mafor objective of this paper is to develop the technology to protect electronics and computerized facilities against lightning-caused overvoltages. The study is oriented on the control of the potential rise of down conductors with the type and installation method of down conductors. As a result, to reduce side flashes and hazards caused by the potential rise of down conductor due to lightning current, the coaxial cable with a low characteristic impedance and high insulation level is suitable for a down conductor. In particular it is extremely effective to bond down conductors to the steel supporter, metal raceways and steel frame of structures.

Assessment of Potential Interference between Grounding Electrodes Using ETM Method (ETM 기법을 이용한 접지전극의 전위간섭 평가)

  • Gil, Hyoung-Jun;Kim, Dong-Ook;Kim, Dong-Woo;Lee, Ki-Yeon;Choi, Chung-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.333-336
    • /
    • 2007
  • This paper deals with assessment of potential interference between grounding electrodes using ETM(Electrolytic Tank Modeling) method. When a test current flowed through grounding electrode, potential rise was measured and analyzed using an electrolytic tank in real time. In order to analyze the potential interference between grounding electrodes, ETM method was studies. Potential interference between isolated grounding electrodes was evaluated as functions of the separation distance between grounding electrodes and the configuration of grounding electrode to be induced. It was found that the separation distance between grounding electrodes in reducing the potential interference was a major factor.

  • PDF

Grounding Characteristic Analysis of Plate Electrodes

  • Kim, Sung-Sam;Kim, Ju-Chan;Koh, Hee-Seog
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.53-60
    • /
    • 2007
  • In this study, an experiment on the efficient construction method of plate electrodes, the influence of electric potential interference in plate electrodes, and building foundations were explored. The experimental result of the electric potential measurement was taken on the basis of the direction of movement and the condition in which the plate electrodes are laid underground in building foundations. It shows that the construction method of laying the plate electrodes vertically exhibits a more efficient reduction of electric potential in a diagonal direction and on an X axis than laying plates horizontally. For plate electrode construction in an area that has uniform conditions, the parallel joint construction method is more effective than a single construction to reduce earth electrical potential and ground resistance. In addition, a straight arrangement performs well in ground efficiency, compared to the parallel arrangement.

A Study on the Image Evaluation of Envelope Component for the Multifamily Housing in the Historical Urban Context (역사지역에서 도시저층집합주택의 건축요소별 이미지 비교평가 연구)

  • Kim, Byoung-Jin;Shon, Seung-Kwang
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.119-124
    • /
    • 2008
  • In Korea, most of the historic city became a deteriorated area with low-rise settlement. It is revaluated as a s great potential in spite of slum clearance and redevelopment for a long while after 1970s. A great achievement for low rise multi family housing, in spite of these social change, is not easy to find the cases and social commonness. In the view points, this article deals a ideal model in historic areas, and the model should be get the understanding from the people, because acceptance from people is the beginning for making historic housing areas. The facade model for evaluation prepared as three types, and responses for the models processed by AHP(Analysis Hierarchy Process).

  • PDF

Design Optimization Using Conflicting Building Information - A case Study Focused on the View and Structure in High-Rise Building Design

  • Cheon, Janghwan
    • Architectural research
    • /
    • v.15 no.2
    • /
    • pp.69-75
    • /
    • 2013
  • Within residential high-rise market there are many value determining factors. Site condition, view, program, units and structure are important parameters that are directly related to the financial aspect of the project. However, most of the studies of high-rise building design focus on the facade and the shape strategies from an esthetic point of view without considering these factors. The objective of this study is to investigate new design approach that incorporates site, program and structural information at an early stage as a generator of building form and explore a wide range of strategies to negotiate these factors in the process of design/decision making. Not being based on designer's subjective preference or style, architects still can create interesting building design through integration and negotiation of various building information. Since this form is based on real data, not just play of form, we can expect that this form has great potential to be developed into real one at the later design phase.

A Study on the Pulse Generator using PFN (PFN을 이용한 펄스발생기의 연구)

  • Lee, B.H.;Joung, K.M.;Park, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1773-1775
    • /
    • 1998
  • This paper deals with the pulse generator using PFN(Pulse Forming Network), and its operation characteristics and application. Two kinds of pulse generator were composed of the best appropriate condition circuit. The output current of the one pulse generator has the rise time of 28 ns and the pulse duration of $7{\mu}s$. The other pulse generator has high current of about 2kA. By use of the former generator with rapid rise time, the impulse impedance characteristic of ground electrodes was investigated with measuring the ground potential rise when the pulse current was injected into the ground electrode.

  • PDF

The Ropeless Elevator: New Transportation System for High-rise Buildings (and Beyond)

  • Belmonte, Martina;Trabucco, Dario
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.1
    • /
    • pp.55-62
    • /
    • 2021
  • The paper reports the result of a 2-year long research conducted by CTBUH on the design possibilities enabled by the Ropeless and Multidirectional elevator systems, investigating how such a significant innovation (or better to say revolution) in the vertical transportation could affect tall buildings first and cities then. The purpose of the study is to prefigure the adoption of ropeless and multidirectional cabins for tall buildings mobility, with the aim to overcome the evolutionary bottleneck of the high-rise building type due to the exclusively vertical direction of transport, which limited, over the years, the design possibilities in terms of height, shape and relations with the surrounding environment. CTBUH research team, together with professionals in the field and supporting academic advisors, developed a series of design considerations on plan organizations, dispatching alternatives and on the integration of horizontal direction in the circulation, with the aim of anticipating potential and criticality arising from the application of ropeless and multidirectional systems.

Novel Water-Soluble Polyfluorenes as an Interfacial layer leading to Cathodes-Independent High Performance of Organic Solar Cells

  • Oh, Seung-Hwan;Shim, Hee-Sang;Park, Dong-Won;Jeong, Yon-Kil;Lee, Jae-Kwang;Moon, Seung-Hyeon;Kim, Dong-Yu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.394-394
    • /
    • 2009
  • Water solubility of conjugated polymers may offer many applications. Potential applications of water-soluble conjugated polymers include the polymer light-emitting diode and new materials for nano and micro hollow-capsules, and bio- or chemo-sensors. We synthesized neutral polyfluorenes containing bromo-alkyl groups by the palladium catalyzed Suzuki coupling reaction. Bromo-alkyl side groups in neutral polyfluorenes were quaternized by tri-methyl amine solution. The electrochemical and optical properties of water-soluble conjugated polymers are discussed. This novel synthesized water-soluble conjugated polymers were used as a interfacial dipole layer between active layer and metal cathode in polymer solar cell for enhancement of open-circuit voltage (Voc), which is one of the most critical factors in determining device characteristics. We also investigated the device performance of polymer solar cell with different metal cathode such as Al, Ag, Au and Cu. In polymer solar cell, novel cationic water-soluble conjugated polymers were inserted between active layer and high-work function cathode (Al, Ag, Au and Cu).

  • PDF