• Title/Summary/Keyword: Potable

Search Result 213, Processing Time 0.026 seconds

Kinetics Change of the R-134a Gas Hydrate Formation in Seawater with the Addition of Edible Surfactants (R-134a 가스 하이드레이트 형성 속도에 미치는 식용 계면활성제 첨가의 영향)

  • Jeong, Hui Cheol;Kim, A Ram;Lim, Jun-Heok;Won, Yong Sun
    • Clean Technology
    • /
    • v.22 no.3
    • /
    • pp.154-160
    • /
    • 2016
  • For any conceivable desalination process using the gas hydrate formation, the kinetics has to be one of the most important parameters from the economic point of view. We thus were to improve the kinetics of the R-134a (also known as HFC-134a) gas hydrate formation by using promoters and three different kinds of edible surfactants were selected for the desalination process targeted to produce potable water; κ-carrageenan, lecithin, and polysorbate 80 among anionic, amphoteric, and nonionic surfactants, respectively. Then, the kinetics change of the R-134a hydrate formation was monitored by varying the surfactant concentration. Experimental results demonstrated that the rate of R-134a hydrate formation increases with the addition of edible surfactants in general and the effect as a promotor has an order of polysorbate 80 > κ-carrageenan > lecithin. As a supportive measure, the atomic charges of each surfactant were calculated by using a DFT (density functional theory)-based molecular modeling and the results showed a positive relationship between the promotor effect of each surfactant and the number of oxygens available for hydrogen bonding and the negativity of their atomic charge values.

Honeycomb-type Single Chamber SOFC Running on Methane-Air Mixture (Methane-Air 혼합 Gas에서 구동하는 하니컴 형태의 SC-SOFC)

  • Park Byung-Tak;Yoon Sung Pil;Kim Hyun Jae;Nam Suk Woo;Han Jonghee;Lim Tae-Hoon;Hong Seong-Ahn;Lee Dokyol
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.306-309
    • /
    • 2005
  • One of the most critical issues in sol id oxide fuel cell (SOFC)running on hydrocarbon fuels is the risk of carbon formation from the fuel gas. The simple method to reduce the risk of carbon formation from the reactions is to add steam to the fuel stream, leading to the carbon gasification react ion. However, the addition of steam to fuel is not appropriate for the auxiliary power unit (APU) and potable power generation (PPG) systems due to an increase of complexity and bulkiness. In this regard, many researchers have focused on so-called 'direct methane' operation of SOFC, which works with dry methane without coking. However, coking can be suppressed only by the operation with a high current density, which may be a drawback especially for the APU and PPG systems. The single chamber fuel cell (SC-SOFC) is a novel simplification of the conventional SOFC into which a premixed fuel/air mixture is introduced. It relies on the selectivity of the anode and cathode catalysts to generate a chemical potential gradient across the cell. Moreover it allows compact and seal-free stack design. In this study, we fabricated honeycomb type mixed-gas fuel cell (MGFC) which has advantages of stacking to the axial direction and increasing volume power density. Honeycomb-structured SOFC with four channels was prepared by dry pressing method. Two alternative channels were coated with electrolyte and cathode slurry in order to make cathodic reaction sites. We will discuss that the anode supported honeycomb type cell running on mixed gas condition.

  • PDF

Status of intestinal parasite infections in inhabitants of Palmar, Guavas Province, Ecuador (에꽈돌국 과야스주 빨말 본당 지역 주민의 장내 기생충 감염상태)

  • Jo, Seung-Yeol;Kim, Jung-Ho;Park, Seong-Hak
    • Parasites, Hosts and Diseases
    • /
    • v.28 no.2
    • /
    • pp.109-114
    • /
    • 1990
  • Status of intestinal protozoan and helminthic infections was surveyed in mestizo population living in rural parish of Palmar and its nearby recintos(villages) , Three of the surveyed villages were at the Pacific coast and 5 villages were in inner pasture land, located about 100 km west of Guayaquil, the second largest city in Ecuador. One stool sample was examined by one cellophane thick smear for helminth ova and one direct smear stained with Lugol's iodine solution for protozoan cysts. Of 325 persons examined, 66.1% were positive for any ova or cyst. The positive rates were: 18.1% for Ascaris lumbricoides, 19.4% for Trichuris trichiura, 0.6% for hookworm, 3.7% for Hyntenolepis nana, 1.8% for Taenia sp., 19.4% for Entnmoeba histolytica, 28.6% for Entamoeba coli, 5.5% for Endolimax nasa, 1.5% for ledamoeba buetschlii, 11.l% for eiardia lamblia and 0.6% for Chilomastix mesnili. Poor supply of potable water was considered the main cause of high prevalence of intestinal protozoan infections.

  • PDF

Potable Water Treatment Study using the Double Stage Fiber Filter for the Pre-treatment of the Reverse Osmosis Membrane (역삼투막 전처리로서의 2단 섬유상 여과기를 이용한 정수처리 연구)

  • Bae, Si-Youl;Jang, Hyung-Wook;Yun, Chang-Han
    • Membrane Journal
    • /
    • v.20 no.2
    • /
    • pp.97-105
    • /
    • 2010
  • This study was to evaluate the performance of the Double stage Pore controllable fiber (DP) filter system as the pre-treatment of the RO membrane. The evaluation for the pre-treatment filter was performed through the indirect method, SDI (Silt Density Index) measurement of the filtrate. This study was done during Jan. 3 of 2009 to Dec. 3 of 2009 at OO Water Treatment Plant that was suppling industrial water to plants, and the raw water was contaminated lake water and it was fed to the system after clarification with coagulation. The average turbidity of the feed water and that of the filtrate was 0.79 NTU (0.28~4.01 NTU), and 0.16 NTU (0.04~0.50) respectively. And so the average turbidity removal efficiency was 77%. The filtrate flow rate and the backwash water flow rate was about 230 $m^3$/day and about 8.7 $m^3$/day respectively, and so the backwash rate was 3.8%. The data for some samples were obtained after a few days storage, and it caused the higher turbidity and SDI15 as the storage time was increased. But average SDI value of the filtrate was 3.6 (2.26~5.00) which was lower than minimum value required by the RO membrane manufacturer as the RO feed water to guarantee the life time of the RO membrane. So, the DP filter system was enough for the application as the pre-treatment of the RO membrane.

Effects of Fine Particles on Pulmonary Function of Elementary School Children in Ulsan (미세먼지가 울산지역 초등학생의 폐기능에 미치는 영향)

  • Yu, Seung-Do;Cha, Jung-Hoon;Kim, Dae-Seon;Lee, Jong-Tae
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.5
    • /
    • pp.365-371
    • /
    • 2007
  • To evaluate the effect of air pollution on respiratory health in children, We conducted a longitudinal study in which children were asked to record their daily levels of Peak Expiratory Flow Rate(PEFR) using potable peak flow meter(mini-Wright) for 4 weeks. The relationship between daily PEFR and ambient air particle levels was analyzed using a mixed linear regression models including gender, age in year, weight, the presence of respiratory symptoms, and relative humidity as an extraneous variable. The daily mean concentrations of $PM_{10}$ and $PM_{2.5}$ over the study period were $64.9{\mu}g/m^3$ and $46.1{\mu}g/m^3$, respectively. The range of daily measured PEFR in this study was $182{\sim}481\;l/min$. Daily mean PEFR was regressed with the 24-hour average $PM_{10}(or\;PM_{2.5})$ levels, weather information such as air temperature and relative humidity, and individual characteristics including sex, weight, and respiratory symptoms. The analysis showed that the increase of air particle concentrations was negatively associated with the variability in PEFR. We estimated that the IQR increment of $PM_{10}$ or $PM_{2.5}$ were associated with 1.5 l/min (95% Confidence intervals -3.1, 0.1) and 0.8 l/min(95% CI -1.8, 0.1) decline in PEFR. Even though this study showed negative findings on the relationship between respiratory function and air particles, it was worth noting that the findings must be interpreted cautiously because exposure measurement based on monitoring of ambient air likely resulted in misclassification of true exposure levels and this was the first Korean study that $PM_{2.5}$ measurement was applied as an index of air quality.

Absorbed and effective dose for periapical radiography using portable and wall type dental X-ray machines (이동형 구내방사선촬영기와 벽걸이 구내방사선촬영기로 촬영한 치근단 방사선촬영에서 환자의 흡수선량과 유효선량 평가)

  • Han, Won-Jeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.184-190
    • /
    • 2012
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for one periapical radiography using the portable and wall type dental X-ray machines. Materials and methods: Thermoluminescent chips were placed at 25 sites throughout the layers of the head and neck of a tissue-equivalent human skull phantom. The man phantom was exposed with the portable and wall type dental X-ray machines. For one periapical radiography taken by portable dental X-ray machine, the exposure setting was 60 kVp, 2 mA and 0.2 seconds, while for one periapical radiography taken by wall type dental X-ray machine, exposure setting was 70 kVp, 8 mA and 0.074 seconds. Absorbed dose measurements were performed and equivalent doses to individual organs were summed using ICRP 103 to calculate effective dose. Results: In the upper anterior periapical radiography using portable dental X-ray machine and in the lower posterior periapical radiography using both machines, the highest absorbed dose was recorded at the mandible body. The effective dose in upper anterior periapical radiography using portable and wall type dental X-ray machines was $4{\mu}Sv$, $2{\mu}Sv$, respectively. In the lower posterior periapical radiography, the effective dose for each portable and wall type dental X-ray machines was $6{\mu}Sv$, $2{\mu}Sv$. Conclusion: It was recommended that the operator use prudently potable dental X-ray machine because that the effective dose in the periapical radiography using wall type dental X-ray machine was lower than that in the periapical radiography using portable dental X-ray machine.

Development of Liquid Crystal Optic Modulation Based X-ray Dosimeter by Using CdS Sensor (CdS 센서를 이용한 액정 광변조 X-선 검출 시스템 개발)

  • Noh, Si-Cheol;Kang, Sang-Sik;Jung, Bong-Jae;Choi, Il-Hong;Kim, Hyun-Hee;Cho, Chang-Hoon;Park, Jun-Hong;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.357-361
    • /
    • 2011
  • In this study, the liquid-crystal optical modulation X-ray detection system using a CdS which is a family of II-IV compound semiconductor was proposed. The system consist of the detector, the signal processing part, the liquid-crystal driving parts, microcontroller, and I/O parts, and was designed to be suitable for miniaturization and portable. In addition, the system can measure a wide range X-ray by using the detecting range selection. In order to evaluate the performance of the proposed system, the CdS sensor's output characteristics were confirmed in accordance with changes of dose, and excellent correlation was determined. And also, the optical penetration ratio was discussed in accordance with changes of the applied voltage by measuring the change of the liquid-crystal in accordance with changes of the applied voltage. Through these results, the characteristics of the liquid-crystal optical modulation system such as the excellent reproducibility and the noise immunity were confirmed. And we considered that the CdS cell-based liquid-crystal optical modulated portable X-ray detection system could be applied to compact, low-cost, portable system.

Anti-stress Effect of Scutellatia baicalensis in SD Rats and ICR Mice

  • Ryu, Jong-Hoon;Tan-Lee, Blendyl Saguan;Jung, Ji-Woong;Ahn, Nam-Yoon;Lee, Seung-Joo;Yu, Gu-Young;Han, Shin-Ha;Lee, Jeong-Hoon;Lee, Geum-Seon;Cheong, Jae-Hoon
    • Biomolecules & Therapeutics
    • /
    • v.12 no.1
    • /
    • pp.34-42
    • /
    • 2004
  • The aim of this study is to investigate anti-stress effect of Scutellaria baicalensis(SB). The experiments were performed with the use of young (9 weeks of age) male rats of SD strain and the male ICR mice (20-25 g) at the time of first treatment with SB. Animals of the normal group were not exposed to any stress and the control group were exposed to stress. The rats of the Ginseng, Diazepam(BZ) and SB supplementary group were orally administered once a day 100 mg of red ginseng extract, 5 mg of BZ or 100 mg of SB extract/kg body weight and they were exposed to stress. The mice of the Ginseng, BZ and SB supplementary group were given water containing 200 mg of red ginseng extract, 10 mg of BZ or SB extract/100 ml potable water and exposed to stress. Animals were given supplements for 7 days without stress, and then were given supplement for 5 days with restraining and electroshock stress. We recorded stress related behavioral changes of the experimental animals by stressing them using the Etho-vision system and measured levels of blood corticosterone and IL-2. SB supplementation partially blocked the stress effect on locomotion in the rats and mice, and also partially blocked stress-induced behavioral changes such as freezing, burrowing, grooming, smelling, and rearing behavior in the rats and smelling, grooming, tailing, and rearing in the mice. in elevated plus maze test, the staying time of the stressed rats and mice in the open area decreased while it increased in the closed area. But these changes also partially were blocked by SB-supplementation. SB-supplementation decreased levels of the blood corticosterone which was increased by stress in the rats but did not significantly increase levels of blood interleukin 2 which was decreased by stress in mice.

A Study On Low-cost LPR(License Plate Recognition) System Based On Smart Cam System using Android (안드로이드 기반 스마트 캠 방식의 저가형 자동차 번호판 인식 시스템 구현에 관한 연구)

  • Lee, Hee-Yeol;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.471-477
    • /
    • 2014
  • In this paper, we propose a low-cost license plate recognition system based on smart cam system using Android. The proposed system consists of a portable device and server. Potable device Hardware consists of ARM Cortex-A9 (S5PV210) processor control unit, a power supply device, wired and wireless communication, input/output unit. We develope Linux kernel and dedicated device driver for WiFi module and camera. The license plate recognition algorithm is consisted of setting candidate plates areas with canny edge detector, extracting license plate number with Labeling, recognizing with template matching, etc. The number that is recognized by the device is transmitted to the remote server via the user mobile phone, and the server re-transfer the vehicle information in the database to the portable device. To verify the utility of the proposed system, user photographs the license plate of any vehicle in the natural environment. Confirming the recognition result, the recognition rate was 95%. The proposed system was suitable for low cost portable license plate recognition device, it enabled the stability of the system when used long time by using the Android operating system.

Manufacture of Portable Inflatable Kayak Using Ultra High Pressure Drop Stitch (초고압 공간지를 이용한 포터블 인플레터블 카약 제작)

  • Park, Chan-Hong;Park, Byeong-Ho;Park, Jong-Dae;Seong, Hyeon-Kyeong;Lim, Lee-Young
    • Journal of Navigation and Port Research
    • /
    • v.37 no.5
    • /
    • pp.551-557
    • /
    • 2013
  • In this paper, we manufactured portable inflatable kayak using ultra high pressure drop stitch. by improving inflatable kayaks' performance with a design using the extra-high-voltage special space paper, they were manufactured to go near to performance of hard shell kayaks. The kayaks were manufactured having all merits of the performance of hard shell kayaks and functionality and portability of the inflatable kayaks, and through performance evaluation of test products, the performance was compared with previous hard shell kayaks. About 6 knot of target speed in the verification result of resistance performance, the developed kayak was more excellent than the HOBIE-KONA kayak by 12.33%. In case of same displacement in a result of inclination test, the centroid of the developed kayak was less distributed by 22.7% than the HOBIE-KONA kayak, based on the bottoms of the ships. This makes the difference for righting arm (GZ) lessened to some degree because the developed kayak is lower than the HOBIE-KONA kayak in the centroid. In the dynamic stability of ship bodies, the HOBIE-KONA kayak showed a little excellent performance. However, in rudder force and resistance factor, the developed kayak was more outstanding than the HOBIE-KONA kayak.