• Title/Summary/Keyword: Postoperative alignment

Search Result 56, Processing Time 0.021 seconds

Inferomedially impacted zygomatic fracture reduction by reverse vector using an intraoral approach with Kirschner wire

  • Jang, Jin Woo;Cho, Jaeyoung;Burm, Jin Sik
    • Archives of Plastic Surgery
    • /
    • v.48 no.1
    • /
    • pp.69-74
    • /
    • 2021
  • Background In inferomedially rotated zygomatic fractures sticking in the maxillary sinus, it is often difficult to achieve complete reduction only by conventional intraoral reduction. We present a new intraoral reduction technique using a Kirschner wire and its clinical outcome. Methods Among 39 inferomedially impacted zygomatic fractures incompletely reduced by a simple intraoral reduction trial with a bone elevator, a Kirschner wire (1.5 mm) was vertically inserted from the zygomatic body to the lateral orbital rim in 17 inferior-dominant rotation fractures and horizontally inserted to the zygomatic arch in nine medial-dominant and 13 bidirectional rotation fractures. A Kirschner wire was held with a wire holder and lifted in the superolateral or anterolateral direction for reduction. Following reduction of the zygomaticomaxillary fracture, internal fixation was performed. Results Fractures were completely reduced using only an intraoral approach with Kirschner wire reduction in 33 cases and through an additional lower lid or transconjunctival incision in six cases. There were no surgical complications except in one patient with undercorrection. Postoperative 6-month computed tomography scans showed complete bone union and excellent bone alignment. Four patients experienced difficulty with upper lip elevation; however, these problems spontaneously resolved after manual tissue lump massage and intralesional steroid (Triamcinolone) injection. Conclusions We completely reduced infraorbital rim fractures, zygomaticomaxillary buttresses, and zygomaticofrontal suture fractures in 84% of patients through an intraoral approach alone. Intraoral Kirschner wire reduction may be a useful option by which to obtain effective and powerful reduction motion of an inferomedially rotated zygomatic body.

Outcomes of Single-Incision Thoracoscopic Surgery Using the Spinal Needle Anchoring Technique for Primary Spontaneous Pneumothorax

  • Lee, Seung Hyong;Lee, Sun-Geun;Cho, Sang-Ho;Song, Jae Won;Kim, Dae Hyun
    • Journal of Chest Surgery
    • /
    • v.55 no.1
    • /
    • pp.44-48
    • /
    • 2022
  • Background: Although classical multi-port video-assisted thoracic surgery has been widely performed, single-incision thoracoscopic surgery (SITS) is a popular surgical technique for the treatment of primary spontaneous pneumothorax (PSP). However, the inconvenient alignment of instruments and the limited field of view occasionally make surgeons convert from SITS to multi-port surgery or extend the incision. This study aimed to present an easy and safe SITS technique for PSP using a spinal needle. Methods: In total, 139 patients underwent SITS between May 2011 and December 2017. We used a spinal needle to hook the bulla or bleb, and wedge resection was performed through a small incision. Patients' medical records were reviewed retrospectively, and a telephone survey was conducted to investigate the recurrence rate. Results: The mean age of the 139 patients was 23.62±9.60 years. The mean operative time was 36.69±14.64 minutes, and multi-port conversion was not performed. The mean postoperative hospital stay was 3.00±0.78 days, and the mean indwelling chest tube duration was 1.97±0.77 days. No complications were observed. In the mean follow-up period of 86.75±23.20 months, recurrence of pneumothorax was found in 3 patients. Conclusion: We suggest that SITS for PSP with the aid of a spinal needle to replace a grasper is a safe and easy technique that only requires a small incision.

Cementless Total Hip Arthroplasty Using Ceramic Femoral Head on Cross-Linked Ultra-High-Molecular Weight Polyethylene Liner in Patients Older than 65 Years: Minimum Five-Year Follow-Up Results (세라믹 대퇴 골두 및 교차결합 초고분자량 폴리에틸렌 라이너를 이용한 65세 이상 무시멘트형 인공 고관절 전치환술: 최소 5년 중기 추시 결과)

  • Yun, Ho Hyun;Cheong, Ji Young;Sim, Hyun Bo;Park, Jae Hong
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.490-497
    • /
    • 2018
  • Purpose: To evaluate the utility of ceramic-on-polyethylene articular bearing surface when cementless total hip arthroplasty is performed in patients older than 65 years through an analysis of the minimum five-year follow-up results using the ceramic femoral head and cross-linked polyethylene liner. Materials and Methods: From March 2010 to September 2012, 51 patients (56 hips) who were older than 65 years were enrolled in this retrospective study. The mean age at surgery was $70.9{\pm}5.1years$ old. A clinical assessment was analyzed using the Harris hip score. For the radiographic assessment, the cup inclination and anteversion, stem alignment, and wear amount were measured. The postoperative complications were also determined. Results: The mean Harris hip score was improved from preoperative 48 points to postoperative 87 points (p<0.05). The mean cup inclination was $40.9^{\circ}{\pm}6.4^{\circ}$ and the mean cup anteversion was $20.3^{\circ}{\pm}8.1^{\circ}$. The mean cup anteversion of the elevated liner-used group (16 cases) was $14.3^{\circ}{\pm}7.9^{\circ}$ and the mean cup anteversion of the neutral liner used group (40 cases) was $22.4^{\circ}{\pm}9.1^{\circ}$ (p<0.05). The mean stem alignment angle was $0^{\circ}$ (range, varus $4^{\circ}$-valgus $4^{\circ}$). The mean linear wear amount was $0.458{\pm}0.041mm$ and the average annual linear wear rate was $0.079{\pm}0.032mm/yr$. Six cases (10.7%) of intraoperative periprosthetic femoral fractures were encountered. Conclusion: Based on these results, the use of a ceramic-on-polyethylene articular bearing surface in elderly patients with cementless total hip arthroplasty is beneficial. On the other hand, careful effort is needed to prevent intraoperative periprosthetic femoral fractures.

Stabilization of Short Juxta-articular Fractures Using a Circular External Skeletal Fixator System in Dogs (개에서 원형외고정장치를 이용한 관절주위 골절의 안정화)

  • Cheong, Hye-Yeon;Kim, Joo-Ho;Cha, Jae-Gwan;Seol, Jae-Won;Kim, Min-Su;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.31 no.6
    • /
    • pp.523-526
    • /
    • 2014
  • Three dogs were admitted for repair of bone fracture. Case 1 (Maltese, 1.8 kg, intact female, 5-month-old) and case 2 (poodle, 3.0 kg, intact female, 6-month-old) had non-weight bearing lameness in the left pelvic limb, and case 3 (mixed, 3.3 kg, intact female, age unknown) had non-weight-bearing lameness in the left thoracic limb. On orthopedic examination, there was pain, crepitus, palpable instability and substantial soft tissue swelling on the affected side. No neurological deficits were identified. Radiographs revealed left proximal metaphyseal tibial and fibular fractures in cases 1 and 2, and left proximal metaphyseal radial and ulnar fractures in case 3. All cases had closed long-bone fractures with short juxta-articular fracture segments. Under fluoroscopic guidance, proper placement of the ring fixation elements was confirmed during surgery. Two or three rings were used to stabilize fractures with traditional circular external skeletal fixators (CESF). Postoperative radiographs showed acceptable alignment and apposition of the previously identified fracture. Time to radiographic union ranged from 5 to 14 weeks and there were no signs of implant failure or pin tract infection. Functional outcomes were excellent in all cases. CESF can be successfully used to reduce short juxta-articular fractures in which bone plates or external skeletal fixation cannot be applied.

One-point versus two-point fixation in the management of zygoma complex fractures

  • Lee, Kyung Suk;Do, Gi Cheol;Shin, Jae Bong;Kim, Min Hyung;Kim, Jun Sik;Kim, Nam Gyun
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.4
    • /
    • pp.171-177
    • /
    • 2022
  • Background: The treatment of zygoma complex fractures is of crucial importance in the field of plastic surgery. However, surgical methods to correct zygoma complex fractures, including the number of fixation sites, differ among operators. Although several studies have compared two-point and three-point fixation, no comparative research has yet been conducted on one-point versus two-point fixation using computed tomography scans of surgical results. Therefore, the present study aimed to address this gap in the literature by comparing surgical results between one-point and two-point fixation procedures. Methods: In this study, we randomly selected patients to undergo surgery using one of two surgical methods. We analyzed patients with unilateral zygoma complex fractures unaccompanied by other fractures according to whether they underwent one-point fixation of the zygomaticomaxillary buttress or two-point fixation of the zygomaticomaxillary buttress and the zygomaticofrontal suture. We then made measurements at three points-the zygomaticofrontal suture, inferior orbital wall, and malar height-using 3-month postoperative computed tomography images and performed statistical analyses to compare the results of the two methods. Results: All three measurements (zygomaticofrontal suture, inferior orbital wall, and malar height) showed significant differences (p< 0.05) between one-point and two-point fixation. Highly significant differences were found for the zygomaticofrontal suture and malar height parameters. The difference in the inferior wall measurements was less meaningful, even though it also reached statistical significance. Conclusion: Using three parameters in a statistical analysis of imaging findings, this study demonstrated significant differences in treatment outcomes according to the number of fixations. The results indicate that bone alignment and continuity can be achieved to a greater extent by two-point fixation instead of one-point fixation.

Postoperative Pulmonary Vein Stenosis (PVS) in Patients with TAPVR (전 폐정맥 환류 이상의 수술 후 폐정맥 협착에 대한 분석)

  • Jung Sung-Ho;Park Jeong-Jun;Yun Tae-Jin;Jhang Won-Kyoung;Kim Young-Hwue;Ko Jae-Kon;Park In-Sook;Seo Dong-Man
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.347-353
    • /
    • 2006
  • Background: Despite recent advances in surgical technique and perioperative care of total anomalous pulmonary venous return (TAPVR), post-repair pulmonary vein stenosis (PVS) remains as a serious complication. We thought that the most important factors of TAPVR repair to prevent PVS were good exposure, proper alignment, and sufficient stoma size. We analyzed our experience retrospectively. Material and Method: Between Jan. 1995 and Feb. 2005, we studied 74 patients diagnosed with TAPVR suitable for biventricular repair. Supra-cardiac type (n=41, 55.4%) was the most common. Mean CPB time, ACC time, and TCA (40.5%, 30/74) time were $92.1{\pm}25.9\;min,\;39.1{\pm}10.6\;min$, and $30.2{\pm}10.7\;min$, respectively. Mean follow-up duration was $41.4{\pm}29.1$ months and follow-up was possible in all patients. Result: The median age and body weight at operation were 28.5 days ($0{\sim}478$ days) and 3.4 kg $(1.4{\sim}9\;kg)$. Early mortality was 4.1% (3/74). Causes of death were pulmonary hypertensive crisis, sepsis, and sudden death. There was PR-PVS in 2 patients (early: 1, late: 1). Both patients were cardiac type TAPVR drained to coronary sinus. Re-operations were done but only one patient survived. Cumulative survival rate in 5 year and percent freedom from PVS were $94.5{\pm}2.7%\;and\;97.2{\pm}2.0%$, respectively. Conclusion: There was no PVS in patients who underwent extra-cardiac anatomosis between LA and CPVC. Therefore it could be said that our principle might be effective in preventing PR-PVS in patients suitable two-ventricle.