• 제목/요약/키워드: Postmortem imaging

검색결과 17건 처리시간 0.029초

3T MREIT 시스템을 이용한 실험견 사체의 두부 도전율 영상 (Conductivity Imaging of a Canine Head using a 3T MREIT System with a Carbon-Hydrogel Electrode: Postmortem Experiment)

  • 정우철;김영태;;김형중;이태휘;강병택;박희명;우응제
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권2호
    • /
    • pp.179-184
    • /
    • 2009
  • Magnetic Resonance Electrical Impedance Tomography (MREIT) is a new bio-imaging modality providing cross-sectional conductivity images from measurements of internal magnetic flux densities produced by externally injected currents. Recent MREIT studies demonstrated successful conductivity image reconstructions of postmortem and in vivo canine brain. However, the whole head imaging was not achieved due to technical issues related with electrodes and noise in measured magnetic flux density data. In this study, we used a new carbon-hydrogel electrode with a large contact area and injected 30 mA imaging current through a canine head. Using a 3T MREIT system, we performed a postmortem canine experiment and produced high-resolution conductivity images of the entire canine head. Collecting magnetic flux density data inside the head subject to multiple injection currents, we reconstructed cross-sectional conductivity images using the harmonic $B_z$ algorithm. The conductivity images of the canine head show a good contrast not only inside the brain region including white and gray matter but also outside the brain region including the skull, temporalis muscle, mandible, lingualis proprius muscle, and masseter muscle.

Electrical Impedance Tomography and Biomedical Applications

  • Woo, Eung-Je
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 공동학술대회 논문집
    • /
    • pp.1-6
    • /
    • 2007
  • Two impedance imaging systems of multi-frequency electrical impedance tomography (MFEIT) and magnetic resonance electrical impedance tomography (MREIT) are described. MFEIT utilizes boundary measurements of current-voltage data at multiple frequencies to reconstruct cross-sectional images of a complex conductivity distribution (${\sigma}+i{\omega}{\varepsilon}$) inside the human body. The inverse problem in MFEIT is ill-posed due to the nonlinearity and low sensitivity between the boundary measurement and the complex conductivity. In MFEIT, we therefore focus on time- and frequency-difference imaging with a low spatial resolution and high temporal resolution. Multi-frequency time- and frequency-difference images in the frequency range of 10 Hz to 500 kHz are presented. In MREIT, we use an MRI scanner to measure an internal distribution of induced magnetic flux density subject to an injection current. This internal information enables us to reconstruct cross-sectional images of an internal conductivity distribution with a high spatial resolution. Conductivity image of a postmortem canine brain is presented and it shows a clear contrast between gray and white matters. Clinical applications for imaging the brain, breast, thorax, abdomen, and others are briefly discussed.

  • PDF

Hypertrophic cardiomyopathy secondary to severe right and left ventricular outflow tract obstruction in a Maltese dog

  • Yoon, Won-Kyoung;Suh, Sang-Il;Oh, Yeon-Su;Hyun, Changbaig
    • 대한수의학회지
    • /
    • 제55권3호
    • /
    • pp.209-211
    • /
    • 2015
  • An 8-year-old spayed female Maltese (2.5 kg of body weight) presented with the primary complaint of loud heart murmur and exercise intolerance. Diagnostic imaging revealed severe pulmonic stenosis (peak velocity 5.2 m/s) with right ventricular hypertrophy. The dog revisited after 2 years, at which time, diagnostic imaging revealed severe biventricular hypertrophy, dynamic left ventricular outflow tract obstruction, left atrial dilation and pulmonary hypertension with worsened pre-existing pulmonic stenosis. Postmortem investigation revealed hypertrophic cardiomyopathy and regional myocardial infarction. The case was diagnosed as hypertrophic cardiomyopathy secondary to severe right and left ventricular outflow tract obstruction.

두 마리 고양이에서 발생한 급성 척수 경색의 자기 공명 영상학적 진단 증례 (Magnetic Resonance Imaging Features of Suspected Acute Spinal Cord Infarction in Two Cats)

  • 정선영;김보은;지서연;윤정희;최민철
    • 한국임상수의학회지
    • /
    • 제30권4호
    • /
    • pp.320-323
    • /
    • 2013
  • 척수 경색은 고양이에서 급성 척수 병증의 주요한 원인으로써 인식되고 있다. 사후 조직 병리학적 검사를 통해 확진 할 수 있지만 MR 영상학적 특징은 척수 경색의 진단에 가치있는 정보를 제공한다. 본 증례의 목적은 두 마리의 고양이에서 발생한 급성 척수 경색의 영상학적 특징을 설명하고 그 진단에 있어서 low field MRI (0.3 Tesla)의 유용성을 평가하는 것이다. 미확인 연령의 중성화 수컷, mixed breed 고양이가 급성의 사지 부전 마비를 주증으로 내원하였고 9살령의 중성화 암컷 domestic short hair 고양이는 후지 부전 마비로 내원하였으며 하루 후 후지 완전 마비가 나타났다. 이후 실시된 MR 영상에서 첫번째 고양이의 경우 두번째 경추부터 여섯번 째 경추 수준의 척수에서 병변이 분포하였으며 두번째 고양이의 경우 두번째 요추부터 다섯번째 요추 수준에서 병변이 나타났다. 두 고양이에서 공통적으로 주로 회백질에 분포한 척수 실질 내에 국소적인 병변이 확인되었으며 T2 강조 영상 및 FLAIR 영상에서 고신호를 나타내었고 DWI 영상에서 고신호, ADC map 에서는 저신호를 나타내었다. 히스토리, 임상증상 및 다른 실험실적 검사와 함께 MR 영상학적 특징을 통해 두 고양이에서 급성 척수 경색이 진단되었다.

MREIT of Postmortem Swine Legs using Carbon-hydrogel Electrodes

  • Minhas, Atul S.;Jeong, Woo-Chul;Kim, Young-Tae;Kim, Hyung-Joong;Lee, Tae-Hwi;Woo, Eung-Je
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권6호
    • /
    • pp.436-442
    • /
    • 2008
  • Magnetic resonance electrical impedance tomography(MREIT) has been suggested to produce cross-sectional conductivity images of an electrically conducting object such as the human body. In most previous studies, recessed electrodes have been used to inject imaging currents into the object. An MRI scanner was used to capture induced magnetic flux density data inside the object and a conductivity image reconstruction algorithm was applied to the data. This paper reports the performance of a thin and flexible carbon-hydrogel electrode that replaces the bulky and rigid recessed electrode in previous studies. The new carbon-hydrogel electrode produces a negligible amount of artifacts in MR and conductivity images and significantly simplifies the experimental procedure. We can fabricate the electrode in different shapes and sizes. Adding a layer of conductive adhesive, we can easily attach the electrode on an irregular surface with an excellent contact. Using a pair of carbon-hydrogel electrodes with a large contact area, we may inject an imaging current with increased amplitude primarily due to a reduced average current density underneath the electrodes. Before we apply the new electrode to a human subject, we evaluated its performance by conducting MREIT imaging experiments of five swine legs. Reconstructed conductivity images of the swine legs show a good contrast among different muscles and bones. We suggest a future study of human experiments using the carbon-hydrogel electrode following the guideline proposed in this paper.

Chemical Shift Artifact Correction in MREIT

  • Minhas, Atul S.;Kim, Young-Tae;Jeong, Woo-Chul;Kim, Hyung-Joong;Lee, Soo-Yeol;Woo, Eung-Je
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권6호
    • /
    • pp.461-468
    • /
    • 2009
  • Magnetic resonance electrical impedance tomography (MREIT) enables us to perform high-resolution conductivity imaging of an electrically conducting object. Injecting low-frequency current through a pair of surface electrodes, we measure an induced magnetic flux density using an MRI scanner and this requires a sophisticated MR phase imaging method. Applying a conductivity image reconstruction algorithm to measured magnetic flux density data subject to multiple injection currents, we can produce multi-slice cross-sectional conductivity images. When there exists a local region of fat, the well-known chemical shift phenomenon produces misalignments of pixels in MR images. This may result in artifacts in magnetic flux density image and consequently in conductivity image. In this paper, we investigate chemical shift artifact correction in MREIT based on the well-known three-point Dixon technique. The major difference is in the fact that we must focus on the phase image in MREIT. Using three Dixon data sets, we explain how to calculate a magnetic flux density image without chemical shift artifact. We test the correction method through imaging experiments of a cheese phantom and postmortem canine head. Experimental results clearly show that the method effectively eliminates artifacts related with the chemical shift phenomenon in a reconstructed conductivity image.

개에서 컴퓨터단층촬영을 이용한 두부 외상의 평가 3례 (Computed Tomographic Evaluation of Three Canine Patients with Head Trauma)

  • 김태훈;김주형;조항묘;천행복;강지훈;나기정;모인필;이영원;최호정;김근형;장동우
    • 한국임상수의학회지
    • /
    • 제24권4호
    • /
    • pp.667-672
    • /
    • 2007
  • This report describes the use of conventional computed tomography(CT) for the diagnosis of head trauma in three canine patients. According to physical and neurologic examinations, survey radiography and computed tomography, these patients were diagnosed as traumatic brain injury. Especially, CT is the imaging modality of first choice for head trauma patients. It provides rapid acquisition of images, superior bone detail, and better visualization of acute hemorrhage than magnetic resonance imaging. It is also less expensive and more readily available. Pre-contrast computed tomography was used to image the head. Then, post-contrast CT was performed using the same technique. The Modified Glasgow Coma Scale(MGCS) score was used to predict their probability of survival rate after head trauma in these dogs. Computed tomogram showed fluid filled tympanic bulla, fracture of the left temporal bone and cerebral parenchymal hemorrhage with post contrast ring enhancement. However, in one case, computed tomographic examination didn't delineate cerebellar parenchymal hemorrhage, which was found at postmortem examination. Treatments for patients placed in intensive care were focused to maintain cerebral perfusion pressure and to normalize intracranial pressure. In these cases, diagnostic computed tomography was a useful procedure. It revealed accurate location of the hemorrhage lesion.

Development of a Small Animal CT using a Linear Detector Array and Small-Scale Slip Rings

  • An Ung Hwan;Chun In Kon;Lee Sang Chul;Cho Min Hyoung;Lee Soo Yeol
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권1호
    • /
    • pp.43-47
    • /
    • 2005
  • We have developed a small bore x-ray CT for small animal imaging with a linear x-ray detector array and small-scale slip rings. The linear x-ray detector array consists of 1024 elements of 400□m×400□m with a gadolinium oxysulfide (GOS) scintillator on top of them. To avoid use of expensive large diameter slip rings for projection data transmission from the X­ray detector to the image reconstruction system, we used the wireless LAN technology. The projection data are temporally stored in the data acquisition system residing on the rotating gantry during the scan and they are transmitted to the image reconstruction system after the scan. With the wireless LAN technology, we only needed to use small-scale slip rings to deliver the AC electric power to the X-ray generator and the power supply on the rotating gantry. The performances of the small animal CT system, such as SNR, contrast, and spatial resolution, have been evaluated through experiments using various phantoms. It has been experimentally found that the SNR is almost linearly proportional to the tube current and tube voltage, and the minimum resolvable contrast is less than 30 CT numbers at 40kVp/3.0㎃. The spatial resolution of the small animal CT system has been found to be about 0.9Ip/㎜. Postmortem images of a piglet is also presented.

Intracranial anaplastic oligodendroglioma concurrent with hydrocephalus and syringomyelia in a Boston terrier dog

  • Park, Chul;Kang, Byeong-Teck;Yoo, Jong-Hyun;Kim, Ha-Jung;Jung, Dong-In;Lim, Chae-Young;Kim, Jae-Hoon;Woo, Eung-Je;Kang, Sang-Chul;Park, Hee-Myung
    • 대한수의학회지
    • /
    • 제48권1호
    • /
    • pp.93-98
    • /
    • 2008
  • A 6-year-old female Boston terrier dog was presented with seizure episode, forelimb paraparesis, excessive panting, and ataxia. On physical and neurological examination, episcleral vessel engorgement, delayed postural reaction, delayed pupillary light reflex (both direct and consensual), and crossed forelimb were noted. Serum biochemical profiles were not remarkable other than mildly elevated hepatic enzymes. On cerebrospinal fluid analysis, elevated protein concentration was observed. In magnetic resonance imaging scans, the left frontal brain lesion with ring enhancement strongly suggested the presence of intracranial tumor. Concurrently, secondary hydrocephalus and syringomyelia were also observed. The dog was euthanized at 4 months after initial presentation because of aggravated neurological signs. This case was definitely diagnosed as an intracranial anaplastic oligodendroglioma based on postmortem histopathologic examination.

Zoom-in X-ray Micro Tomography System

  • Chun, In-Kon;Lee, Sang-Chul;Park, Jeong-Jin;Cho, Min-Hyoung;Lee, Soo-Yeol
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권5호
    • /
    • pp.295-300
    • /
    • 2005
  • We introduce an x-ray micro tomography system capable of high resolution imaging of a local region inside a small animal. By combining two kinds of projection data, one from a full field-of-view (FOV) scan of the whole body and the other from a limited FOV scan of the region of interest, we have obtained zoomed-in images of the region of interest without any contrast a nomalies. We have integrated a micro tomography system using a micro-focus x-ray source, a $1248\times1248$ flat-panel x-ray detector, and a precision scan mechanism. Using the cross-sectional images taken with the zoom-in micro tomography system, we measured trabecular thicknesses of femur bones in postmortem rats. To compensate the limited spatial resolution in the zoom-in micro tomography images, we used the fuzzy distance transform for the calculation of the trabecular thickness. To validate the trabecular thickness measurement with the zoom-in micro tomography images, we compared the measurement results with the ones obtained from the conventional micro tomography images of the extracted bone samples.