• Title/Summary/Keyword: Posterior edentulous

Search Result 172, Processing Time 0.031 seconds

Re-establishment of occlusal plane in a patient with a failed implant prosthesis (실패한 임플란트 보철수복물을 가진 환자의 교합평면 재설정)

  • Kang, Hyeon-Goo;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.141-153
    • /
    • 2018
  • A non-physiological occlusal plane caused by continuous tooth loss, occlusal wear, and failure of a prosthesis may result in an unattractive appearance and functional problems, such as reduced masticatory efficiency and occlusal interference. Therefore, when undertaking prosthetic treatment for edentulous patients or patients with a collapsed occlusal plane, it is important to establish an occlusal plane that is compatible with masticatory function. The patient in this case report had undergone restoration of a completely edentulous maxilla using an implant-supported fixed prosthesis. On follow-up examination in the following 6 years, mechanical complications were observed in the existing implant prosthesis, including porcelain chipping, occlusal wear, and screw loosening. Moreover, due to occlusal wear and supraeruption of the opposing anterior teeth, as well as loss of some posterior teeth, the occlusal plane had collapsed. Following diagnosis, the patient underwent full mouth rehabilitation, involving additional implant installation in edentulous sites, recreation of the existing prosthesis, and prosthetic restoration of all remaining teeth.

The comparison between 2 wide implants and 3 regular implants in mandibular posterior area (하악 대구치부위의 고정성 보철물에서 2개의 장폭경과 3개의 표준 임프란트의 비교)

  • Yoo, Ho-Sun;So, Sung-Soo;Han, Dong-Hoo;Cho, Kyoo-Sung;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.577-588
    • /
    • 2002
  • Osseointegrated implants have been established as the standard treatment modality for full/partial edentulous patients since the 1960's, and the long term results for full edentulous patients have proven to be successful. Based on these results osseointegrated implants are now widely used for partial edentulous patients. There has been an increased interest towards the efficacy of wide implants, despite many reports mentioning the lower success rate of wide implants compared to regular implants. Recently, mandibular molar area defects are commonly restored using 2 wide implants, but it is not determined whether which treatment modality-3 regular implants or 2 wide implants-shows superior success rate. In this study, 2 wide implants and 3 regular implants used for the restoration of mandibular molar area are used to compare the survival rate of 1-4 years, and to analyze and compare the failure factors. The following conclusions could be drawn from this study. 1. Wide implants and regular implants showed 94.5% and 97,6% of survival rate respectively. After prosthodontic work, the survival rate was 100% and 98.1% for wide implants and regular implants respectively. 2. 5 failed implants have been removed. 2 wide implants and 1 regular implant have been removed due to failure of osseointegration. 1 wide implant was removed due to abscess formation caused by over-heating, and 1 regular implant was removed due to mechanical failure caused by over-loading within the first year of function. 3. No statistically significant difference was observed with respect to the amount of marginal bone loss of wide and regular implants.(P>0.05) In conclusion, restoration of the mandibular molar area using 3 regular implants was found to be a good treatment modality, and 2 wide implants could he considered a good treatment modality when success factors are taken into account.

Full mouth rehabilitation of edentulous patient with fixed implant prosthesis (고정성 임플란트 보철물을 이용한 완전 무치악 환자의 구강회복 증례)

  • Shi, Hee-Hyun;Kim, Jong-Jin;Baik, Jin;Cha, Hyun-Suk;Lee, Joo-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.3
    • /
    • pp.147-156
    • /
    • 2021
  • There are various treatment options such as conventional complete denture, hybrid prosthesis and implant-supported fixed prosthesis for fully edentulous patients. In case of implant-supported fixed prosthesis, compared to removable prosthesis, it is difficult to place the implant in the correct position considering the anatomical contours of the final prosthesis. In this case, a full mouth rehabilitation with implant-supported fixed prosthesis was performed for a patient who required extraction of all remaining teeth due to dental caries and chronic periodontitis. In the implant placement stage, the implant was placed in the desired position using a surgical guide fabricated considering the anatomical contours of the final prosthesis, and the function and esthetics were evaluated through correction and re-fabrication of the fixed provisional restoration. A final restoration of porcelain fused to gold prosthesis was delivered to the patient based on the provisional restoration. To cope with complications such as loosening of screws and fracture of porcelain, a screw-retained type prosthesis was fabricated for the posterior part and a screw-cement-retained type prosthesis for the anterior part. As a result, the patient showed an improved prognosis in terms of functional and esthetics after the final prosthesis was delivered.

A comparative study of impression methods using stock tray and intraoral scanner in a completely edentulous patient with an atypical arch shape: a case report (비정형적인 악궁을 가진 완전 무치악 환자에서 기성 트레이와 구강 스캐너를 이용한 인상 채득 방법의 비교 연구: 증례 보고)

  • Jae-Hoon Park;Ji-Hyun Kim;Jae-Min Seo;Jung-Jin Lee;Yeon-Hee Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.344-355
    • /
    • 2023
  • In complete denture fabrication, accurate preliminary impressions are crucial for obtaining an accurate final impression. However, it can be challenging in cases of atypical arch shapes. This case report compares diagnostic casts made with a stock tray and an intraoral scanner (IOS) in a patient with an atypical arch shape. A 58-year-old edentulous male patient with long, narrow, atypical arches was referred to the Oral and Maxillofacial Surgery department for complete denture fabrication. Compared to the diagnostic cast obtained using IOS with adequately captured anatomical parameters, the primary model obtained using a stock tray showed prominent overextended flanges on the labial and buccal sides of the maxillary arch and less prominent overextended flanges in the mandibular arch with pressure spots in the posterior palatal seal area. The custom tray fabricated from such a model required additional adjustment resulting in increased chair time during the final impression procedure.

PIEZOELECTRIC VERTICAL BONE AUGMENTATION USING SANDWICH TECHNIQUE IN ATROPHIC MANDIBLE: TWO CASES REPORT (Sandwich technique을 이용한 하악골 증대술의 치험 보고)

  • Lee, Ji-Soo;Lee, Jung-Kwang;Lee, Hyun-Jin;Ahn, Mi-Ra;Sohn, Dong-Seok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.3
    • /
    • pp.276-282
    • /
    • 2008
  • Objective: This is to report the efficacy of the sandwich technique for bone augmentation in a moderate atrophic posterior mandible through clinical and histological results in two cases. Subjects and Method: Two patients selected had moderate bone resorption in left lower edentulous area. Sandwich osteotomy using the piezosurgery was performed and the osteomized alveolar segments were elevated by 6mm in each two patients. The interpositional mineral allograft materials were inserted in the atrophic posterior mandibles. After four months healing period, bone biopsies in the grafted areas and placement of dental implants were performed. In both cases, panoramic views were taken preoperatively to measure the alveolar bone height for diagnosis, to monitor patient healing, and to evaluate bone healing and bone gain. Results: Sufficient vertical bone height was gained by using the sandwich technique and implants were placed successfully. In radiological evaluation, there was minimal resorption of bone height after the second operation and in histomorphometric evaluation, they showed favorable new bone formation without inflammation in the grafted areas. Conclusion: The sandwich technique can be an effective choice for augmenting vertical bone height in the atrophic mandible. More of cases and long term follow-up are needed to evaluate bone resorption and implant prognosis.

Implant Fixture Installation in the Posterior Maxilla Using a Tooth-supported Surgical Template Based on Computer Assisted Treatment Planning (컴퓨터 보조 기반 치아 지지 서지컬 템프레이트를 이용한 상악구치부 임플란트 식립)

  • Kim, Soung Min;Kim, Myung Joo;Lee, Jee Ho;Myoung, Hoon;Lee, Jong Ho;Kim, Myung Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.6
    • /
    • pp.381-389
    • /
    • 2013
  • Two patients with partial edentulous maxilla were scheduled to undergo installation of implant fixtures using a tooth-supported surgical template based on computer assisted treatment planning. After 3-dimensional (3D) computed tomographic scanning was transferred to the OnDemand3D (Cybermed Co., Seoul, Korea) software program for virtual planning, fixtures of MK III Groovy RP implant of the Br${\aa}$nemark System (Nobel Biocare AB Co., G$\ddot{o}$teborg, Sweden) was installed using the In2Guide (CyberMed Co., Seoul, Korea) tooth-supported surgical template with a Quick Guide Kit (Osstem Implant Co., Seoul, Korea) system in the posterior maxilla of each patient. Sinus floor elevation with a xenogenic bone graft procedure was also performed simultaneously in one patient. Fixture installations were completed successfully without complications, such as sinus mucosa perforation, bony bleedings, fenestrations, or others. During the last two-year follow-up period after prosthetics delivery, each implant was found to be fine with no other minor complications. The entire procedures are reported and the literatures on use of tooth-supported surgical template was reviewed.

A case of full mouth rehabilitation in patient with loss of vertical dimension and deep bite due to tooth wear (치아 마모로 인한 수직고경감소와 과개교합을 가진 환자에서 전악 수복 증례)

  • Seo, Seong-Yong;Lee, Na-Young;Kang, Jeong-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.31-39
    • /
    • 2018
  • The collapse of the posterior occlusion destroys the normal occlusal plane and causes excessive wear reducing the vertical dimension. Reduced vertical dimension of occlusion causes not only aesthetic and functional problems but also overloading on the temporomandibular joints and abnormalities of muscle nerve system. In order to improve the collapsed occlusal relationship, it is necessary to consider the change of the vertical dimension. It is necessary to make a precise diagnosis and analysis before the treatment and to evaluate the adaption of patient to the new vertical dimension of occlusion. A patient with excessive overbite often has occlusal problems of tooth wear and tooth eruption. Considering these considerations, overall prosthodontic restoration is required to solve the problem. A patient of 68 year old man in this case who suffered major tooth wear and maxillary posterior teeth loss was treated with elevation of vertical dimension of occlusion by maxillary removable dental prosthesis and mandibular fixed prosthesis.

A RETROSPECTIVE STUDY OF THE SURGICAL SUCCESS AND VERTICAL BONE RESORPTION RATE AFTER AUTOGENOUS BLOCK ONLAY GRAFT IN POSTERIOR MAXILLA (상악 구치부에서 자가골편 이식술의 예후와 골 변화량에 관한 후향적 연구)

  • Myoung, Mee-Rang;Kim, Myung-Rae;Kim, Sun-Jong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.5
    • /
    • pp.340-345
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the surgical success of bone reconstruction of the severely atrophic maxilla using autogenous block bone onlay graft from the ramus and ilium prior to dental implantation. And we measured the amount of vertical height change Material and Methods: 26 partially edentulous patients(32 case) who needed block onlay bone graft before implant placement in posterior maxillary area from 2002 to 2009 were selected for this study. Patients consisted of 20 males & 6 females and the average of their age was 54.2. Patients who were treated with ramal bone were 19 case and patients who were treated with iliac bone were 11 case. Digital panoramic X-ray was taken at the day of surgery, 3 months and 6 months later after the surgery. Vertical height change & resorption rate of grafted bone were measured with the same X-rays and compared Results: Two out of 32 bone grafts had to be removed because of inflamation at the grafts area(97.3%). The mean of radiographic vertical height change(change rate) of post-op. 3 month was 0.54mm(8.5%)and 6 month was 0.99mm(15.9%). Compairing to intraoral donor site(ramus), iliac bone had more vertical height change(1.18mm) at 6 month after surgery. Conclusions: Within the limit of this study, autogenous block onlay grafts can be considered a promising treatment for severely atrophic maxilla.

Does cone-beam CT alter treatment plans? Comparison of preoperative implant planning using panoramic versus cone-beam CT images

  • Guerrero, Maria Eugenia;Noriega, Jorge;Castro, Carmen;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.121-128
    • /
    • 2014
  • Purpose: The present study was performed to compare the planning of implant placement based on panoramic radiography (PAN) and cone-beam computed tomography (CBCT) images, and to study the impact of the image dataset on the treatment planning. Materials and Methods: One hundred five partially edentulous patients (77 males, 28 females, mean age: 46 years, range: 26-67 years) seeking oral implant rehabilitation were referred for presurgical imaging. Imaging consisted of PAN and CBCT imaging. Four observers planned implant treatment based on the two-dimensional (2D) image data-sets and at least one month later on the three-dimensional (3D) image dataset. Apart from presurgical diagnostic and dimensional measurement tasks, the observers needed to indicate the surgical confidence levels and assess the image quality in relation to the presurgical needs. Results: All observers confirmed that both imaging modalities (PAN and CBCT) gave similar values when planning implant diameter. Also, the results showed no differences between both imaging modalities for the length of implants with an anterior location. However, significant differences were found in the length of implants with a posterior location. For implant dimensions, longer lengths of the implants were planned with PAN, as confirmed by two observers. CBCT provided images with improved scores for subjective image quality and surgical confidence levels. Conclusion: Within the limitations of this study, there was a trend toward PAN-based preoperative planning of implant placement leading towards the use of longer implants within the posterior jaw bone.

A COMPARISON OF ACCURACY BETWEEN FIXTURE IMPRESSION AND ABUTMENT IMPRESSION FOR DENTAL IMPLANTS (치과 임플랜트용 고정체 인상법과 지대원주 인상법간의 정확성 비교)

  • Choi, Hyun-Sik;Yim, Soon-Ho;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.662-673
    • /
    • 1997
  • The purpose of this study was to compare the accuracy between future impression and abutment impression using strain gauges. The master model used in this study was a partially edentulous mandibular metal cast with two fixture analogs on both sides. On the left, two future analogs were parallel, whereas right side, posterior future analog exhibiting a 15-degree lingual inclination. From master cast, 10 impressions were made for each of the three impression methods. The master frameworks was fabricated on the master model, and two-element strain gauge was attached to a master framework. The master framework was seated on each cast, and gold screws were tightened to 10 Ncm using a torque controller AI-1600 strain measurement system was used for strain measuring. Impression methods studied were : Group 1:abutment impression Group 2:fixture impression Group 3:combined impression (anterior:fixture impression, posterior:abutment impression) The results were as followed. 1. The strain values on X-axis and Y-axis according to the three impression methods showed no significant difference. 2. The strain values on parallel and angulated groups according to the three impression methods showed no significant difference. 3. The parallel group exhibited significantly higher accuracy in adaptation than angulated group for all experimental groups (p<0.05). In conclusion, it is considered that accuracy of implant prostheses is more affected by implant angulation than impression methods.

  • PDF