• Title/Summary/Keyword: Post-chlorine

Search Result 29, Processing Time 0.111 seconds

Reduced Post-Chlorine Dosage Required for Disinfection: Improvement with Ozonation and GAC Process (오존 및 입상활성탄 도입시 후염소 주입량 저감효과 분석)

  • Baek, Young-Ae;Joe, Woo-Hyeun;Kim, Jong-Moon;Choi, Young-Jun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.445-452
    • /
    • 2007
  • This study was carried out to examine effect of post-chlorine dosage reduction by ozonation and GAC process in the field plant for 3years in the "G" water purification plant in Seoul. And it is to compare GAC with BAC process in removal effects of TOC, THMs, THMFP, $UV_{254}$. As a result, chlorine dosage of ozonation and GAC(=BAC) is less demand than GAC. Seasonal reduction of chlorine demand is from about 37% to 59% with BAC, and from 24 to 46% with GAC. Higher reduction in BAC could be achieved. The efficiency of chlorine demand reduction with ozonation was depending on the organic carbon removal. $UV_{254}$ concentration is less about 0.13~0.74L/mg.m in BAC than GAC. Therefore, the combination of ozonation and GAC was more effective in reducing post-chlorine than the single GAC. TOC was also monitored, and results show that a linear relationship between TOC and chlorine demand is appropriate under each treatment process. It means that removal of organic matter(TOC) from finished water is necessary to reduce post-chlorine dosage in clear well and to minimize order of chlorine in distribution systems.

Most suitable design method of post-chlorination process in portable water process by using CFD (전산유체를 활용한 정수공정에서 후염소 투입공정 최적설계 방안)

  • Cho, Youngman
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.3
    • /
    • pp.331-337
    • /
    • 2013
  • Post-chlorination for disinfection in portable water process is final process. The design factors of post-chlorination are inflow pipe line from tank of filtrated water to cleanwell, injection point of chlorine, appropriate shape of baffle in cleanwell for disinfection efficient improvement. Until now, we did not have the design standard for post-chlorination. we evaluated most suitable design method of post-chlorination process in portable water process by using computational fluid dynamics in this research. We found the result that the pipe to connect the cleanwell should be one. If pipe line split into two or more, uniform distribution of the flow is difficult. Second, optimal injection point of chlorine is the middle of pipe line to connect the cleanwell. Therefore, it is not economical to install chlorine contact basin in cleanwell. Third, the shape of baffle should be designed in order to water flows in one direction. And we found that it is better to design the low number of flow turning.

Prediction Models to Control Pro-chlorination in Water Treatment Plant (정수장 후염소 공정제어를 위한 예측모델 개발)

  • Shin, Gang-Wook;Lee, Kyung-Hyuk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.2
    • /
    • pp.213-218
    • /
    • 2008
  • Prediction models for post-chlorination require complicated information of reaction time, chlorine dosage considering flow rate as well as environmental conditions such as turbidity, temperature and pH. In order to operate post-chlorination process effectively, the correlations between inlet and outlet of clear well were investigated to develop prediction models of chlorine dosages in post-chlorination process. Correlations of environmental conditions including turbidity and chlorine dosage were investigated to predict residual chlorine at the outlet of clear well. A linear regression model and autoregressive model were developed to apply for the post-chlorination which take place time delay due to detention in clear well tank. The results from autoregressive model show the correlationship of 0.915~0.995. Consequently, the autoregressive model developed in this study would be applicable for real time control for post chlorination process. As a result, the autoregressive model for post chlorination which take place time delay and have multi parameters to control system would contribute to water treatment automation system by applying the process control algorithm.

Chromaticity removal by chlorine and ozone oxidation in water treatment (상수처리에서 염소 및 오존산화를 이용한 색도제거)

  • Lee, Jeonghoon;Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.4
    • /
    • pp.273-279
    • /
    • 2017
  • Optimal processes to remove chromaticity at E water treatment plant(WTP) mainly caused by algae of E lake in Jeju island were investigated based on lab-tests of chlorine and ozone oxidation. 42.9% of chromaticity of filtered water was removed by chlorine oxidation under pH 7.0~8.0, dose of 1.0 mg/L with contact time of 30~60 min. On the other hand, chromaticity removal was 71.4% when post-ozone dose of 0.9~1.9 mg/L and pH 9.0, while it was increased to 86.7% under post-ozone dose of 3.1~7.3 mg/L and pH 9.0. However, there was no significant chromaticity removal efficiency increase when ozone doses were higher than 5.0 mg/L regardless of feeding point(i.e., pre-ozonation and post-ozonation) and pHs(i.e., 7.0 and 9.0.) under the experimental conditions. Based on the results, chlorine oxidation using existing chlorination facilities at the WTP is recommended for lower chromaticity while ozone oxidation is recommended for higher chromaticity by installing new ozone feeding facilities.

Syntheses of chlorine resistant reverse osmosis membranes

  • Kim, Nowon;Lee, Yong-Taek
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.170-174
    • /
    • 2004
  • Most of thin film composite reverse osmosis membranes include amide linkages, which are susceptible to chlorine attack resulting in N-chloro derivatives. This study examined a new method based on post-treatment of reverse osmosis membrane with various silane derivatives to improve chlorine resistance. The silane derivatives contain one alkyl group and three alkoxy groups such as trifluoromethyltrimethoxysilane, 3-aminopropylmethoxydiethoxysilane and 3, 3, 3-trifluoropropyltrimethoxysilane. Compared to commercial membranes, silane derivatives coated membranes showed significantly enhanced chlorine durability.

  • PDF

Changes in Physicochemical and Sensory Properties of Fruits as Affected by Chlorine Sterilization (과일류의 염소 소독 방법에 따른 이화학적 및 관능적 품질 특성 변화)

  • Park, Jong-Sook;Nam, Eun-Sook;Park, Shin-In
    • The Korean Journal of Food And Nutrition
    • /
    • v.21 no.4
    • /
    • pp.499-509
    • /
    • 2008
  • The purpose of this study was to investigate the changes in physicochemical and sensory properties of raw fruits during washing and chlorine treatments. Strawberry and banana were pre-prepared at different concentration of chlorinated water(0 ppm, 50 ppm and 100 ppm), immersion time(3 min and 5 min), and number of post-rinsing(1 time, 2 times and 3 times). The physicochemical properties such as pH, sugar contents, residual chlorine contents, color values and hardness of the fruits were analyzed, and the sensory quality were evaluated throughout the sterilization treatment process. After washing strawberry with 100 ppm chlorinated water and 3 times of post-rinsing, pH and residual chlorine contents were showed a little difference, while sugar contents, hardness, and color values(L, a and b) were reduced. In case of banana, pH, sugar contents and residual chlorine contents were not affected, and hardness and L color value were reduced. However, a and b color values of banana were gradually increased as the development of brown discoloration. Sensory properties of the samples were affected by the chlorine sterilization treatment. In overall acceptance, strawberry and banana treated with 100 ppm chlorinated water showed the lowest scores among treatments. Therefore it could be suggested that the application of 50 ppm chlorinated water for $3{\sim}5$ minutes with over 3 times of post-rinsing was the effective pre-preparation method without affecting the quality of the fruits.

Effect of post-annealing on single-walled carbon nanotubes synthesized by arc-discharge

  • Park, Suyoung;Choi, Sun-Woo;Jin, Changhyun
    • Journal of Ceramic Processing Research
    • /
    • v.20 no.4
    • /
    • pp.388-394
    • /
    • 2019
  • In this study, high-purity single-walled carbon nanotubes (SWCNTs) were prepared by removing the unreacted metal constituents and amorphous carbon impurities using a post-annealing process. Unlike conventional thermal processing techniques, this technique involved different gas atmospheres for efficient removal of impurities. A heat treatment was conducted in the presence of chlorine, oxygen, and chlorine + oxygen gases. The nanotubes demonstrated the best characteristics, when the heat treatment was conducted in the presence of a mixture of chlorine and oxygen gases. The scanning electron microscopy, transmission electron microscopy, ultraviolet absorbance, and sheet resistance measurements showed that the heat treatment process efficiently removed the unreacted metal and amorphous carbon impurities from the as-synthesized SWCNTs. The high-purity SWCNTs exhibited improved electrical conductivities. Such high-purity SWCNTs can be used in various carbon composites for improving the sensitivity of gas sensors.

Post-Chlorination Process Control based on Flow Prediction by Time Series Neural Network in Water Treatment Plant

  • Lee, HoHyun;Shin, GangWook;Hong, SungTaek;Choi, JongWoong;Chun, MyungGeun
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.16 no.3
    • /
    • pp.197-207
    • /
    • 2016
  • It is very important to maintain a constant chlorine concentration in the post chlorination process, which is the final step in the water treatment process (hereafter WTP) before servicing water to citizens. Even though a flow meter between the filtration basin and clear well must be installed for the post chlorination process, it is not easy to install owing to poor installation conditions. In such a case, a raw water flow meter has been used as an alternative and has led to dosage errors due to detention time. Therefore, the inlet flow to the clear well is estimated by a time series neural network for the plant without a measurement value, a new residual chlorine meter is installed in the inlet of the clear well to decrease the control period, and the proposed modeling and controller to analyze the chlorine concentration change in the well is a neuro fuzzy algorithm and cascade method. The proposed algorithm led to post chlorination and chlorination improvements of 1.75 times and 1.96 times respectively when it was applied to an operating WTP. As a result, a hygienically safer drinking water is supplied with preemptive response for the time delay and inherent characteristics of the disinfection process.

Evaluation of Advanced Water Treatment Operation

  • Kim, Seung-Hyun
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.54-64
    • /
    • 2002
  • This study evaluated advanced water treatment (AWT) system in Korea. There are currently 16 plants operating with AWT. However, no attempt has been made to evaluate AWT system. This study selected one water treatment plant with AWT (pre-ozonation + BAC). Using the operation data from 1995 to 2001 and pilot study results, the post-evaluation of the AWT system has been conducted. The study found that AWT improved water qualities of organic, ammonia, and turbidity, as expected. However, the extent of the improvement was generally short of the pilot study expectations. Pre-ozonation failed to decrease coagulant consumption. The dosage increased rather than decreased. AWT was, however, successful to decrease chlorine consumption. The chlorine reduction was related to the change in raw water characteristics and AWT introduction. Pre-ozonation failed to decrease coagulant consumption. The dosage increased rather than decreased. AWT was, however, successful to decrease chlorine consumption. The chlorine reduction was related to the change in raw water characteristics and AWT introduction, Both operation of pre-ozonation and reduced ammonia loading were responsible for the reduction. AWT increased the operation cost. Maintenance, raw water, and power cost increased, while labor and chemical cost decreased. Manpower reduction resulting form automation caused the decrease of labor cost. The reduction of chlorine consumption caused the decrease of chemical cost.

  • PDF

Inhibition of Clinical Nosocomial Bacteria by Chlorine Dioxide

  • Jung, Suk-Yul
    • Biomedical Science Letters
    • /
    • v.25 no.4
    • /
    • pp.431-435
    • /
    • 2019
  • Chlorine dioxide is an effective chemical to inhibit the growth of bacteria and viruses or to disinfect infected areas. In this study, the effects of chlorine dioxide on several bacteria in hospitals were analyzed. Alloiococcus otitis, Kocuria rosea, Leuconostoc mesenteroides spp. and Staphylococcus lentus as gram-positive bacteria and Acinetobacter lwoffii, Aeromonas salmonicida, Brucella melitensis, Oligella ureolytica as gram-negative bacteria were done for the inhibitory analysis. The growth and morphology of the bacteria were analyzed by placing a plastic stick which was called "FarmeTok (medistick/Puristic)" provided by Purgofarm, co, Ltd. to release ClO2 (13 ppmv/hr) next to the plate where the bacteria were incubated for 24 hours. Less than 10 bacterial colonies were evaluated as having 99% inhibitory effect. The initial bacterial culture concentration of 0.5 McFaland turbidity was good for analyzing the chlorine dioxide inhibitory effect. All bacteria could be easily counted post 24 hr co-incubation with ClO2, but A. otitis and A. lwoffii without ClO2 gas were not countable due to very dispersed colony types which were not affected for result analysis. As shown in this study, the FarmeTok plastic stick, which discharges chlorine dioxide at 13 ppmv / hour, was evaluated to be sufficient to suppress the above bacteria in the hospital. Bacteria existing in the clinic such as this hospital will be used as a data to inhibit the growth of bacteria by using ClO2, and molecular biology analysis using the gene of bacteria will be possible in the future rather than inhibiting the growth of bacteria itself.