DOI QR코드

DOI QR Code

Most suitable design method of post-chlorination process in portable water process by using CFD

전산유체를 활용한 정수공정에서 후염소 투입공정 최적설계 방안

  • 조영만 (부산광역시상수도사업본부 수질연구소)
  • Received : 2013.02.26
  • Accepted : 2013.06.10
  • Published : 2013.06.15

Abstract

Post-chlorination for disinfection in portable water process is final process. The design factors of post-chlorination are inflow pipe line from tank of filtrated water to cleanwell, injection point of chlorine, appropriate shape of baffle in cleanwell for disinfection efficient improvement. Until now, we did not have the design standard for post-chlorination. we evaluated most suitable design method of post-chlorination process in portable water process by using computational fluid dynamics in this research. We found the result that the pipe to connect the cleanwell should be one. If pipe line split into two or more, uniform distribution of the flow is difficult. Second, optimal injection point of chlorine is the middle of pipe line to connect the cleanwell. Therefore, it is not economical to install chlorine contact basin in cleanwell. Third, the shape of baffle should be designed in order to water flows in one direction. And we found that it is better to design the low number of flow turning.

Keywords

References

  1. Bishop Mark M.(1993) Improving the disinfection detention time of a water plant clearwell, Jour. AWWA, 85(3), 68-75
  2. Mark M. Clark(1999) Improving clearwell design for CT compliance, AWWARF and AWWA
  3. Imad A. Hannoun et. al(1998) Using hydraulic modeling to optimize contact time. AWWA, 90(8), 77-87
  4. Cao, Z., Wiley, D. E., Fane, A. G.,(2001) CFD simulations of net-type turbulence promoters in a narrow channel, J. Membr. Sci. 185, 157-176 https://doi.org/10.1016/S0376-7388(00)00643-8
  5. Cockx, A., Do-quang, Z., Line, A. & Roustan, M.,(1999) Use of computational fluid dynamics for simulating hydrodynamics and mass transfer in industrial ozonation towers, Chem. Eng. Sci., 54(21), 5085-5090 https://doi.org/10.1016/S0009-2509(99)00239-0
  6. Panne erselvam, R., Savithri, S., Surender, G. D.,(2009) CFD simulation of hydrodynamics of gas-liquid-solid fluidised bed reactor, Chem. Eng. Sci., 64(6), 1119-1135 https://doi.org/10.1016/j.ces.2008.10.052
  7. Seong Ho Ryu, Bong Ki Kwon, Dong Woo Lee, Kwang Yeon Kim, Dong Ku Chung, Jong Hoon Park(2003), CFD simulation of Power Block Underdrain System, Workshop presentation file in Korean Society of Water and Wastewater, 2003, 67-70
  8. No Suk Park, Hee Kyung Park, Hyo Won Ahn(2004), Potentials of Computational Fluid Dynamics Technique for Optimization of Water Treatment Process, Journal of Korean Society of Water and Wastewater,18(3), 291-300
  9. Sun Ju Lee(2009), Evaluation of the Flashimixing Type using the CFD in the U,j Water Treatment Plant, Workshop presentation file in Korean Society of Water and Wastewater, 2009, 471-472
  10. Tae Ky un Kim, Young June Choi, Young Mahn Jo(2011), Tracer test and Analysis by Computational Fluid Dynamics to Evaluate the Hydraulic Efficiency of Clearwell, Journal of Korean Society of Water and Wastewater, 25(5), 635-642
  11. Seugho Lim.Chulsoo Kim.Leesoo Yoon.Eonsang Park.Youngjae Lee, (2012) L/W Ratio-Evaluation of Expansion Reservoir through Tracer Test and CFD, Workshop presentation file in Korean Society of Water and Wastewater, 2012, 732-733
  12. Young man Cho, Soojeon Yoo, Jaesoon Roh, Jaehoon Bin, Kwangju Choe, Kwangug Lee, Gibong Lee, Jeonggyu Lee,(2011) Evaluation of pressurized water diffusion in water treatment process using CFD, Korean society of environmental engineers, 33(5), 319-367 https://doi.org/10.4491/KSEE.2011.33.5.359
  13. Young man Cho, Jaesoon Roh, Jaehoon Bin, Tae Kyun Kim, Young June choi, (2011) Evaluation of economic L/W ratio and the best shape of baffle in clearwell by using CFD, Korean society of environmental engineers, 33(6), 432-438 https://doi.org/10.4491/KSEE.2011.33.6.432