• Title/Summary/Keyword: Post removal

Search Result 449, Processing Time 0.032 seconds

A Study on the Application of Pre-Chemical Treatment on the Decentralized Domestic Wastewater Reclamation System (도시의 분산형 생활오수 재생시스템에 화학적 전처리공정도입에 관한 연구)

  • Lee, Sang-Woo;Park, Young-Mi;Seo, Gyu-Tae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.115-121
    • /
    • 2006
  • The purpose of this study was to investigate applicability of pretreatment on the existing biological treatment for domestic wastewater reclamation. From Jar Tests, it was found that optimum dosage of coagulant was PAC 0.5mg/L and $FeCl_3$ 180mg/L for urban sewage. In this study, PAC 0.5mg/L was selected considering sludge production and the amount of coagulant required. In a continuous experiment performed with combining chemical coagulation and biological treatment, a considerable removal efficency was obtained in term of BOD, SS, T-N, T-P and ABS. When the raw sewage was supplied into the pre-chamical treatment facility, the removal of BOD and SS was 48.3% and 81.1%. However T-N removal was very low which means T-N consists of $NH_3-N$ mostly. T-P was almost completely recluced by the chemical addition. The effluent BOD & SS was 57~76 and 21~43mg/L, which could reduce the size of biological treatment facility. From the cost estimation pre-chemical treatment could save around half of the area required for biological treatment with post ceagulation.

Fully Analog ECG Baseline Wander Tracking and Removal Circuitry using HPF Based R-peak Detection and Quadratic Interpolation

  • Nazari, Masoud;Rajeoni, Alireza Bagheri;Lee, Kye-Shin
    • Journal of Multimedia Information System
    • /
    • v.7 no.3
    • /
    • pp.231-238
    • /
    • 2020
  • This work presents a fully analog baseline wander tracking and removal circuitry using high-pass filter (HPF) based R-peak detection and quadratic interpolation that does not require digital post processing, thus suitable for compact and low power long-term ECG monitoring devices. The proposed method can effectively track and remove baseline wander in ECG waveforms corrupted by various motion artifacts, whereas minimizing the loss of essential features including the QRS-Complex. The key component for tracking the baseline wander is down sampling the moving average of the corrupted ECG waveform followed by quadratic interpolation, where the R-peak samples that distort the baseline tracking are excluded from the moving average by using a HPF based approach. The proposed circuit is designed using CMOS 0.18-㎛ technology (1.8V supply) with power consumption of 19.1 ㎼ and estimated area of 15.5 ㎟ using a 4th order HPF and quadratic interpolation. Results show SNR improvement of 10 dB after removing the baseline wander from the corrupted ECG waveform.

Removal of nitrogen and phosphorus of the secondary effluent by electro-coagulation (전기응집을 이용한 2차 유출수의 질소.인 제거 공정 연구)

  • Han, Song-Hee;Chang, In-Soung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.4
    • /
    • pp.579-589
    • /
    • 2012
  • To reduce extensive energy costs of the internal recycling for the purpose of denitrification in the advanced wastewater treatment, a post-treatment process using an electro-coagulation to treat nitrate in the secondary effluents is evaluated in this study. Removals of phosphorus and organics in the secondary effluents by the electro-coagulation were also evaluated to propose an alternative advanced wastewatert treatment process. A series of experiments of the electro-coagulation were carried out with the following 4 different samples: synthetic solution containing nitrate only, synthetic solution containing nitrate as well as phosphorus, secondary effluents from activated sludge cultivated in laboratory, and secondary effluents from real wastewater treatment plants. Removals of nitrate and phosphorus in the synthetic solution were 30 and 97 % respectively, which verified the feasibility of the process. Removals of nitrate, phosphorus and COD in the secondary effluents from the cultivated sludge in laboratory were 49, 90 and 19 % respectively. Removal efficiency of the total nitrogen, nitrrate, phosphorus and COD in the secondary effluent from real wastewater treatment plant were 50, 61, 98 and 80 % respectively. The removal of the total nitrogen was less than the nitrate as expected, which is due to the formation of ammonia nitrogen in the cathode. But the proposed scheme could be an energy saving and alternative process for the advanced wastewater treatment if further studies for the process optimization are carried out.

Loss of Potential Biomarker Proteins Associated with Abundant Proteins during Abundant Protein Removal in Sample Pretreatment

  • Shin, Jihoon;Lee, Jinwook;Cho, Wonryeon
    • Mass Spectrometry Letters
    • /
    • v.9 no.2
    • /
    • pp.51-55
    • /
    • 2018
  • Capture of non-glycoproteins during lectin affinity chromatography is frequently observed, although it would seem to be anomalous. In actuality, lectin affinity chromatography works at post-translational modification (PTM) sites on a glycoprotein which is not involved in protein-protein interactions (PPIs). In this study, serial affinity column set (SACS) using lectins followed by proteomics methods was used to identify PPI mechanisms of captured proteins in human plasma. MetaCore, STRING, Ingenuity Pathway Analysis (IPA), and IntAct were individually used to elucidate the interactions of the identified abundant proteins and to obtain the corresponding interaction maps. The abundant non-glycoproteins were captured with the binding to the selected glycoproteins. Therefore, depletion process in sample pretreatment for abundant protein removal should be considered with more caution because it may lose precious disease-related low abundant proteins through PPIs of the removed abundant proteins in human plasma during the depletion process in biomarker discovery. Glycoproteins bearing specific glycans are frequently associated with cancer and can be specifically isolated by lectin affinity chromatography. Therefore, SACS using Lycopersicon esculentum lectin (LEL) can also be used to study disease interactomes.

Endoscopic management of giant colonic polyps: a retrospective Italian study

  • Paolo Quitadamo;Sara Isoldi;Germana De Nucci;Giulia Muzi;Flora Caruso
    • Clinical Endoscopy
    • /
    • v.57 no.4
    • /
    • pp.501-507
    • /
    • 2024
  • Background/Aims: Polyps greater than 30 mm are classified as "giants". Their endoscopic removal represents a technical challenge. The choice of the endoscopic removal technique is important because it provides a resection sample for precise histopathological staging. This is pivotal for diagnostic, prognostic, and management purposes. Methods: From a retrospective analysis, we obtained a sample of 38 giant polyps. Eighteen polypectomies were performed using the epinephrine volume reduction (EVR) method, nine polypectomies utilized endo-looping or clipping methods, and 11 patients underwent surgery. Results: We obtained en bloc resection with the EVR method in all cases; histology confirmed the correct indication for endoscopic resection in all cases. Moreover, no early or delayed complications were observed, and no patient required hospitalization. Using endo-looping or clipping methods, we observed advanced histology in 1/9 (11.1%) cases, while another patient (1/9, 11.1%) had delayed bleeding. Among patients who underwent surgery, 5/11 (45.5%) were deemed overtreated and three had post-surgical complications. Conclusions: We propose EVR as an alternative technique for giant polyp resection due to its safety, effectiveness, cost-efficiency, and the advantage of avoiding the need to postpone polypectomy to a later time. Further prospective studies might help improve this experience and enhance the technique.

Bacterial Community and Biological Nitrate Removal: Comparisons of Autotrophic and Heterotrophic Reactors for Denitrification with Raw Sewage

  • Lee, Han-Woong;Park, Yong-Keun;Choi, Eui-So;Lee, Jin-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.11
    • /
    • pp.1826-1835
    • /
    • 2008
  • An autotrophic denitrification reactor (ADR-l) and a heterotrophic denitrification reactor (HDR-2) were operated to remove nitrate and nitrite in an anoxic environment in raw sewage. The $NO_3$-N removal rate of ADR-l was shown to range from 52.8% to 78.7%, which was higher than the $NO_3$-N removal rate of HDR-2. Specific denitrification rates (SDNR) of ADR-l and HDR-2 were 3.0 to 4.0 and 1.1 to $1.2\;mgNO_3$-N/gVSS/h, respectively. From results of restriction fragment length polymorphism (RFLP) of the 16S rRNA gene, Aquaspirillum metamorphum, Alcaligenes defragrans, and Azoarcus sp. were $\beta$-Proteobacteria that are affiliated with denitritying bacteria in the ADR-l. Specifically, Thiobacillus denitrificans was detected as an autotrophic denitrification bacteria. In HDR-2, the $\beta$-Proteobacteria such as Denitritying-Fe-oxidizing bacteria, Alcaligenes defragrans, Acidovorax sp., Azoarcus denitrificans, and Aquaspirillum metamorphum were the main bacteria related to denitrifying bacteria. The $\beta$-and $\alpha$-Proteobacteria were the important bacterial groups in ADR-l, whereas the $\beta$-Proteobacteria were the main bacterial group in HDR-2 based on results of fluorescent in situ hybridization (FISH). The number of Thiobacillus denitrificans increased in ADR-l during the operation period but not in HRD-2. Overall, the data presented here demonstrate that many heterotrophic denitritying bacteria coexisted with autotrophic denitrifying bacteria such as Thiobacillus denitrificans for nitrate removal in ADR-l. On the other hand, only heterotrophic denitritying bacteria were identified as dominant bacterial groups in HDR-2. Our research may provide a foundation for the complete nitrate removal in raw sewage of low-COD concentration under anoxic condition without any external organic carbon or the requirement of post-treatment.

Equi-Value Line Program Development for 3-Dimensional Finite Element Models using Personal Computer (개인용 컴퓨터를 이용한 3차원 유한요소 등가곡선 프로그램 개발)

  • Lee, Seok-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.9 no.1
    • /
    • pp.44-52
    • /
    • 1992
  • A post-processor is developed to be effectively usable in the personal computer. 3-dimensional controur lines are shown on the surface of the finite element model and also on the 3-dimensional cutting plane, using the function linearly interpolated onto the triangular elements which are constructed on the surface or sectional polygons. And these polygons are originated from the finite element model, 3-dimensional model is projected on the plane with hidden line removal by comparision technique[6]. The graphic data file is used to increase the protability of the program. It is easy to use in the other computer system if the graphic routine adopted that computer system is developed. The developed program has wide applications in 3-dimensional finite element analysis.

  • PDF

Treatment of Starch Wastewater by Anaerobic Digestion Combined with Hollow Fiber UF

  • No, Seong-Hui;Na, Jae-Un;Kim, Seon-Il
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.745-748
    • /
    • 2000
  • Anaerobic digester coupled with hollow fiber membrane unit. Treatment of starch waste with anaerobic digester-membrane system was studied. $0.17\;m^2$ area of hollow fiber membrane unit of known pore size was immersed into laboratory-scale anaerobic digestion system. The gas production was about $0.74\;m^3/kg$ COD treated. The COD removal efficient was about 80-95% depending on the hydraulic retention time. Crossflow ultrafiltration as Post treatment to anaerobic filter. The study conducted with different membrane pore size indicated that membrane with 1,000,000 molecular weight cut-off size gave a higher COD removal efficiency in the range of 83-87% while giving a study flux of $120-130\;L/m^2\;{\cdot}\;h$. A study was conducted to see the long term clogging effect of membrane also.

  • PDF

Subtalar Arthroscopy (거골하 관절의 관절경술)

  • Ahn, Jae-Hoon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.3
    • /
    • pp.235-241
    • /
    • 2009
  • The development of good quality small-diametered arthroscopes and refined arthroscopic techniques has contributed to the improvement of the subtalar arthroscopy. The therapeutic indications are synovectomy, removal of loose bodies, debridement and drilling of osteochondritis dissecans, excision of subtalar impingement lesions and osteophytes, lysis of adhesions for post-traumatic arthrofibrosis, removal of a symptomatic os trigonum, calcaneal fracture assessment and reduction, and arthroscopic arthrodesis of the subtalar joint. The subtalar arthroscopy can be done in supine position using thigh holder or in lateral decubitus position. The arthroscope generally used is a 2.7-mm 30 degrees short arthroscope. Noninvasive distraction with a strap around the hindfoot can be helpful. Usually anterolateral, middle and posterolateral portals are utilized for inspection and instrumentation within the joint. Twoportal posterior subtalar arthroscopy in prone position can be performed as well with 4.0-mm 30 degrees arthroscope, depending on the type and location of the subtalar pathology. The subtalar arthroscopy is a technically demanding procedure, which requires proper instrumentation and careful operative technique. Possible complications are nerve damage and persistent wound drainage.

  • PDF

EVALUATION OF NONDESTRUCTIVE TESTS ANALYSIS TO ESTIMATE INPLACE STRENGTH OF CONCRETE

  • Parviz Ghoddousi;Mohsen Tadayon;Pedram H. Mojarad
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.672-680
    • /
    • 2005
  • There are a lot of reasons to use In-place tests. Construction schedules often require that operations such as form removal, post-tensioning, termination of curing, and removal of reshores be carried out as early as possible. To enable these operations to proceed safely as soon as possible requires the use of reliable in-place tests to estimate the in-place strength. In-place test results are not reliable for engineering judgment. These results should be interpreted and correlated to standard compressive strength, based on the test method. In this paper some of these test procedures and their limitations are discussed. In this study we will go on for Rebound number, Pullout, Ultrasonic pulse velocity, and Cast-in-place cylinder methods which are most useful methods in the Asia.

  • PDF