• Title/Summary/Keyword: Positron-emission tomography

Search Result 599, Processing Time 0.033 seconds

Intra-abdominal Kikuchi's Disease Mimicking Malignant Lymphoma on FDG PET-CT (FDG PET-CT에서 악성림프종처럼 보이는 복부 기쿠치병)

  • Han, Hye-Suk;Kim, Gi-Hyun;Cho, Young-Shim;Joo, Hye-Jin;Lee, Ok-Jun;Ryu, Dong-Hee;Lee, Ki-Hyeong;Kim, Seung-Taik
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.363-365
    • /
    • 2009
  • Kikuchi's disease is a self-limiting benign disease characterized by cervical lymphadenopathy, but it can be mistaken for malignant disease, and when involved lymph nodes are unusually located, diagnosis can be more difficult. The authors report the case of a 19-year-old man with Kikuchi's disease, who had isolated intra-abdominal lymphadenopathy and increased 18-fluoro-deoxyglucose (FDG) uptake in positron emission tomography-computed tomography (PET-CT). Although its incidence is extremely rare, intra-abdominal Kikuchi's disease with increased FDG uptake in PET-CT image should be considered in the differential diagnosis when constitutional symptoms mimic those of malignant lymphoma.

The feasibility of algorithm for iterative metal artifact reduction (iMAR) using customized 3D printing phantom based on the SiPM PET/CT scanner (SiPM PET/CT에서 3D 프린팅 기반 자체제작한 팬텀을 이용한 iMAR 알고리즘 유용성 평가에 관한 연구)

  • Min-Gyu Lee;Chanrok Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.35-40
    • /
    • 2024
  • Purpose: To improve the image quality in positron emission tomography (PET), the attenuation correction technique based on the computed tomography (CT) data is important process. However, the artifact is caused by metal material during PET/CT scan, and the image quality is degraded. Therefore, the purpose of this study was to evaluate image quality according to with and without iterative metal artifact reduction (iMAR) algorithm using customized 3D printing phantom. Materials and Methods: The Hoffman and Derenzo phantoms were designed. To protect the gamma ray transmission and express the metal portion, lead substance was located to the surface. The SiPM based PET/CT was used for acquisition of PET images according to application with and without iMAR algorithm. The quantitative methods were used by signal to noise ratio (SNR), coefficient of variation (COV), and contrast to noise ratio (CNR). Results and Discussion: The results shows that the image quality applying iMAR algorithm was higher 1.15, 1.19, and 1.11 times than image quality without iMAR algorithm for SNR, COV, and CNR. Conclusion: In conclusion, the iMAR algorithm was useful for improvement of image quality by reducing the metal artifact lesion.

Basic Physical Principles and Clinical Applications of Computed Tomography

  • Jung, Haijo
    • Progress in Medical Physics
    • /
    • v.32 no.1
    • /
    • pp.1-17
    • /
    • 2021
  • The evolution of X-ray computed tomography (CT) has been based on the discovery of X-rays, the inception of the Radon transform, and the development of X-ray digital data acquisition systems and computer technology. Unlike conventional X-ray imaging (general radiography), CT reconstructs cross-sectional anatomical images of the internal structures according to X-ray attenuation coefficients (approximate tissue density) for almost every region in the body. This article reviews the essential physical principles and technical aspects of the CT scanner, including several notable evolutions in CT technology that resulted in the emergence of helical, multidetector, cone beam, portable, dual-energy, and phase-contrast CT, in integrated imaging modalities, such as positron-emission-tomography-CT and single-photon-emission-computed-tomography-CT, and in clinical applications, including image acquisition parameters, CT angiography, image adjustment, versatile image visualizations, volumetric/surface rendering on a computer workstation, radiation treatment planning, and target localization in radiotherapy. The understanding of CT characteristics will provide more effective and accurate patient care in the fields of diagnostics and radiotherapy, and can lead to the improvement of image quality and the optimization of exposure doses.

Are There Any Additional Benefits to Performing Positron Emission Tomography/Computed Tomography Scans and Brain Magnetic Resonance Imaging on Patients with Ground-Glass Nodules Prior to Surgery?

  • Song, Jae-Uk;Song, Junwhi;Lee, Kyung Jong;Kim, Hojoong;Kwon, O Jung;Choi, Joon Young;Kim, Jhingook;Han, Joungho;Um, Sang-Won
    • Tuberculosis and Respiratory Diseases
    • /
    • v.80 no.4
    • /
    • pp.368-376
    • /
    • 2017
  • Background: A ground-glass nodule (GGN) represents early-stage lung adenocarcinoma. However, there is still no consensus for preoperative staging of GGNs. Therefore, we evaluated the need for the routine use of positron emission tomography/computed tomography (PET)/computed tomography (CT) scans and brain magnetic resonance imaging (MRI) during staging. Methods: A retrospective analysis was undertaken in 72 patients with 74 GGNs of less than 3 cm in diameter, which were confirmed via surgery as malignancy, at the Samsung Medical Center between May 2010 and December 2011. Results: The median age of the patients was 59 years. The median GGN diameter was 18 mm. Pure and part-solid GGNs were identified in 35 (47.3%) and 39 (52.7%) cases, respectively. No mediastinal or distant metastasis was observed in these patients. In preoperative staging, all of the 74 GGNs were categorized as stage IA via chest CT scans. Additional PET/CT scans and brain MRIs classified 71 GGNs as stage IA, one as stage IIIA, and two as stage IV. However, surgery and additional diagnostic work-ups for abnormal findings from PET/CT scans classified 70 GGNs as stage IA, three as stage IB, and one as stage IIA. The chest CT scans did not differ from the combined modality of PET/CT scans and brain MRIs for the determination of the overall stage (94.6% vs. 90.5%; kappa value, 0.712). Conclusion: PET/CT scans in combination with brain MRIs have no additional benefit for the staging of patients with GGN lung adenocarcinoma before surgery.

CLINICAL STUDY OF POSITRON EMISSION TOMOGRAPHY WITH $[^{18}F]$-FLUORODEOXYGLUCOSE IN MAXILLOFACIAL TUMOR DIAGNOSIS (구강 악안면 영역의 암종 진단에 있어서 $[^{18}F]$-Fluorodeoxyglucose를 이용한 양전자방출 단층촬영의 임상적 연구)

  • Kim, Jae-Hwan;Kim, Kyung-Wook;Kim, Yong-Kack
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.5
    • /
    • pp.462-469
    • /
    • 2000
  • Positron Emission Tomography(PET) is a new diagnostic method that can create functional images of the distribution of positron emitting radionuclides, which when administered intravenously in the body, makes possible anatomical and functional analysis by quantity of biochemical and physiological process. After genetic and biochemical changes in initial stage, malignant tumor undergoes functional changes before undergoing anatomical changes. So, early diagnosis of malignant tumors by functional analysis with PET can be achieved, replacing traditional anatomical analysis, such as computed tomography(CT) and magnetic resonance image(MRI), etc. Similarly, PET can identify malignant tumor without confusion with scar and fibrosis in follow up check. In the Korea Cancer Center Hospital(KCCH) from October 1997 to September 1999, clinical study was performed in 79 cases that underwent 89 times PET evaluation with [18F]-Fluorodeoxyglucose for diagnosis of oral and maxillofacial tumors, and the data was analysed by Bayesian $2{\times}2$ Classification Table. The results were as follows : Evaluation for initial diagnosis with FDG-PET (P<0.005) 1. Agreement rate or accuracy rate is 88.9%. 2. Sensitivity is 95.2%, and specificity 66.7%. 3. Positive predictive rate is 90.9%, and negative predictive rate 80.0%. 4. In consideration of tumor stage, diagnostic rate in less than stage II was 90% and in greater than stage III 100%. 5. In consideration of tumor size, diagnostic rate in less than T2 was 92.3% and in greater than T3 100%. After primary treatment, evaluation for follow up check with FDG-PET (P < 0.001) 1. Agreement rate or accuracy rate is 85.4%. 2. Sensitivity is 87.5%, and specificity 82.4%. 3. Positive predictive rate is 87.5%, and negative predictive rate 82.4%. 4. In 24 recurred cases, 6 had distant metastasis, and 5 of them were diagnosed with FDG-PET, resulting in diagnostic rate of FDG-PET of 83.3%. From the above results, Positron Emission Tomography with [18F]- Fluorodeoxyglucose appears to be more sensitive and accurate for detecting the presence of oral and maxillofacial tumors, and has various clinical applications such as early diagnosis of tumor in initial and follow up check and detection of distant metastasis.

  • PDF

Incidental Abnormal FDG Uptake in the Prostate on 18-fluoro-2-Deoxyglucose Positron Emission Tomography-Computed Tomography Scans

  • Kang, Pil Moon;Seo, Won Ik;Lee, Sun Seong;Bae, Sang Kyun;Kwak, Ho Sup;Min, Kweonsik;Kim, Wansuk;Kang, Dong Il
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.20
    • /
    • pp.8699-8703
    • /
    • 2014
  • 18-fluoro-2-deoxyglucose positron emission tomography-computed tomography ($^{18}F$-FDG PET/CT) scans are commonly used for the staging and restaging of various malignancies, such as head and neck, breast, colorectal and gynecological cancers. However, the value of FDG PET/CT for detecting prostate cancer is unknown. The aim of this study was to evaluate the clinical value of incidental prostate $^{18}F$-FDG uptake on PET/CT scans. We reviewed $^{18}F$-FDG PET/CT scan reports from September 2009 to September 2013, and selected cases that reported focal/diffuse FDG uptake in the prostate. We analyzed the correlation between $^{18}F$-FDG PET/CT scan findings and data collected during evaluations such as serum prostate-specific antigen (PSA) levels, digital rectal examination (DRE), transrectal ultrasound (TRUS), and/or biopsy to confirm prostate cancer. Of a total of 18,393 cases, 106 (0.6%) exhibited abnormal hypermetabolism in the prostate. Additional evaluations were performed in 66 patients. Serum PSA levels were not significantly correlated with maximum standardized uptake values (SUVmax) in all patients (rho 0.483, p=0.132). Prostate biopsies were performed in 15 patients, and prostate cancer was confirmed in 11. The median serum PSA level was 4.8 (0.55-7.06) ng/mL and 127.4 (1.06-495) ng/mL in the benign and prostate cancer groups, respectively. The median SUVmax was higher in the prostate cancer group (mean 10.1, range 3.8-24.5) than in the benign group (mean 4.3, range 3.1-8.8), but the difference was not statistically significant (p=0.078). There was no significant correlation between SUVmax and serum PSA, prostatic volume, or Gleason score. $^{18}F$-FDG PET/CT scans did not reliably differentiate malignant or benign from abnormal uptake lesions in the prostate, and routine prostate biopsy was not usually recommended in patients with abnormal FDG uptake. Nevertheless, patients with incidental prostate uptake on $^{18}F$-FDG PET/CT scans should not be ignored and should be undergo further clinical evaluations, such as PSA and DRE.

Preoperative Risk Factors for Pathologic N2 Metastasis in Positron Emission Tomography-Computed Tomography-Diagnosed N0-1 Non-Small Cell Lung Cancer

  • Yoon, Tae-hong;Lee, Chul-ho;Park, Ki-sung;Bae, Chi-hoon;Cho, Jun-Woo;Jang, Jae-seok
    • Journal of Chest Surgery
    • /
    • v.52 no.4
    • /
    • pp.221-226
    • /
    • 2019
  • Background: Accurate mediastinal lymph node staging is vital for the optimal therapy and prognostication of patients with lung cancer. This study aimed to determine the preoperative risk factors for pN2 disease, as well as its incidence and long-term outcomes, in patients with clinical N0-1 non-small cell lung cancer. Methods: We retrospectively analyzed patients who were treated surgically for primary non-small cell lung cancer from November 2005 to December 2014. Patients staged as clinical N0-1 via chest computed tomography (CT) and positron emission tomography (PET)-CT were divided into two groups (pN0-1 and pN2) and compared. Results: In a univariate analysis, the significant preoperative risk factors for pN2 included a large tumor size (p=0.083), high maximum standard uptake value on PET (p<0.001), and central location of the tumor (p<0.001). In a multivariate analysis, central location of the tumor (p<0.001) remained a significant preoperative risk factor for pN2 status. The 5-year overall survival rates were 75% and 22.9% in the pN0-1 and pN2 groups, respectively, and 50% and 78.2% in the patients with centrally located and peripherally located tumors, respectively. In a Cox proportional hazard model, central location of the tumor increased the risk of death by 3.4-fold (p<0.001). Conclusion: More invasive procedures should be considered when preoperative risk factors are identified in order to improve the efficacy of diagnostic and therapeutic plans and, consequently, the patient's prognosis.

Trans-Aortic Flow Turbulence and Aortic Valve Inflammation: A Pilot Study Using Blood Speckle Imaging and 18F-Sodium Fluoride Positron Emission Tomography/Computed Tomography in Patients With Moderate Aortic Stenosis

  • Soyoon Park;Woo-Baek Chung;Joo Hyun O;Kwan Yong Lee;Mi-Hyang Jung;Hae-Ok Jung;Kiyuk Chang;Ho-Joong Youn
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.3
    • /
    • pp.145-149
    • /
    • 2023
  • BACKGROUND: 18F-sodium fluoride positron emission tomography/computed tomography (18F-NaF PET/CT) has been proven to be useful in identification of microcalcifications, which are stimulated by inflammation. Blood speckle imaging (BSI) is a new imaging technology used for tracking the flow of blood cells using transesophageal echocardiography (TEE). We evaluated the relationship between turbulent flow identified by BSI and inflammatory activity of the aortic valve (AV) as indicated by the 18F-NaF uptake index in moderate aortic stenosis (AS) patients. METHODS: This study enrolled 18 moderate AS patients diagnosed within the past 6 months. BSI within the aortic root was acquired using long-axis view TEE. The duration of laminar flow and the turbulent flow area ratio were calculated by BSI to demonstrate the degree of turbulence. The maximum and mean standardized uptake values (SUVmax, SUVmean) and the total microcalcification burden (TMB) as measured by 18F-NaF PET/CT were used to demonstrate the degree of inflammatory activity in the AV region. RESULTS: The mean SUVmean, SUVmax, and TMB were 1.90 ± 0.79, 2.60 ± 0.98, and 4.20 ± 2.18 mL, respectively. The mean laminar flow period and the turbulent area ratio were 116.1 ± 61.5 msec and 0.48 ± 0.32. The correlation between SUVmax and turbulent flow area ratio showed the most positive and statistically significant correlation, with a Pearson's correlation coefficient (R2) of 0.658 and a p-value of 0.014. CONCLUSIONS: The high degree of trans-aortic turbulence measured by BSI was correlated with severe AV inflammation.

Role of PET in Gene Therapy (유전자 치료에서 PET의 역할)

  • Lee, Kyung-Han
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.1
    • /
    • pp.74-79
    • /
    • 2002
  • In addition to the well-established use of positron emission tomography (PET) in clinical oncology, novel roles for PET are rapidly emerging in the field of gene therapy. Methods for controlled gene delivery to living bodies, made available through advances in molecular biology, are currently being employed in animals for research purposes and in humans to treat diseases such as cancer. Although gene therapy is still in its early developmental stage, it is perceived that many serious illnesses could be treated successfully by the use of therapeutic gene delivery. A major challenge for the widespread use of human gene therapy is to achieve a controlled and effective delivery of foreign genes to target cells and subsequently, adequate levels of expression. As such, the availability of noninvasive imaging methods to accurately assess the location, duration, and level of transgene expression is critical for optimizing gene therapy strategies. Current endeavors to achieve this goal include methods that utilize magnetic resonance imaging, optical imaging, and nuclear imaging techniques. As for PET, reporter systems that utilize genes encoding enzymes that accumulate positron labeled substrates and those transcribing surface receptors that bind specific positron labeled ligands have been successfully developed. More recent advances in this area include improved reporter gene constructs and radiotracers, introduction of potential strategies to monitor endogenous gene expression, and human pilot studies evaluating the distribution and safety of reporter PET tracers. The remarkably rapid progress occurring in gene imaging technology indicates its importance and wide range of application. As such, gene imaging is likely to become a major and exciting new area for future application of PET technology.

Experiment of proof-of-principle on prompt gamma-positron emission tomography (PG-PET) system for in-vivo dose distribution verification in proton therapy

  • Bo-Wi Cheon ;Hyun Cheol Lee;Sei Hwan You;Hee Seo ;Chul Hee Min ;Hyun Joon Choi
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2018-2025
    • /
    • 2023
  • In our previous study, we proposed an integrated PG-PET-based imaging method to increase the prediction accuracy for patient dose distributions. The purpose of the present study is to experimentally validate the feasibility of the PG-PET system. Based on the detector geometry optimized in the previous study, we constructed a dual-head PG-PET system consisting of a 16 × 16 GAGG scintillator and KETEK SiPM arrays, BaSO4 reflectors, and an 8 × 8 parallel-hole tungsten collimator. The performance of this system as equipped with a proof of principle, we measured the PG and positron emission (PE) distributions from a 3 × 6 × 10 cm3 PMMA phantom for a 45 MeV proton beam. The measured depth was about 17 mm and the expected depth was 16 mm in the computation simulation under the same conditions as the measurements. In the comparison result, we can find a 1 mm difference between computation simulation and measurement. In this study, our results show the feasibility of the PG-PET system for in-vivo range verification. However, further study should be followed with the consideration of the typical measurement conditions in the clinic application.