• Title/Summary/Keyword: Positron emission tomography (PET)

Search Result 485, Processing Time 0.023 seconds

A novel tricyclic derivative for PET imaging of the translocator protein

  • Kwon, Young-Do;Kim, Hee-Kwon
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.2 no.1
    • /
    • pp.37-42
    • /
    • 2016
  • The translocator protein (TSPO) has attracted scientist's attention for Positron Emission Tomography (PET) imaging due to correlation with brain cancer, stroke, and neurodegeneration. Recently, GE-180, a novel tricyclic derivative has been developed as a new high affinity agent for the TSPO and evaluated to confirm a possibility for the TSPO ligand. In this highlight review, several studies for the novel TSPO radiotracer are described.

Development of radiolabelled histone deacetylase inhibitors for PET imaging study

  • Hee-Kwon Kim
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.6 no.2
    • /
    • pp.165-170
    • /
    • 2020
  • Histone Deacetylases (HDACs) are enzymes that have control gene expression regulation and cell state. In additions, inhibitions of HDACs are associated with growth arrest, differentiation, or apoptosis of tumor cell. Thus HDAC inhibition is one of the interesting biological targets. A variety of HDAC inhibitors has been developed by many scientists, and some of chemical structures related with HDAC inhibitors were modified to give radiolabeled HDAC inhibitors for positron emission tomography (PET) study. In this highlight review, the development of radiolabeled HDAC inhibitors for PET study are described.

The Role of $^{18}F$-Fluorodeoxyglucose Positron Emission Tomography in the Treatment of Brain Abscess

  • Park, Seong-Hyun;Lee, Sang-Woo;Kang, Dong-Hun;Hwang, Jeong-Hyun;Sung, Joo-Kyung;Hwang, Sung-Kyoo
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.5
    • /
    • pp.278-283
    • /
    • 2011
  • Objective : The purpose of this study was to evaluate whether $^{18}F$-fluorodeoxyglucose positron emission tomography (FOG-PET) can be used to assess the therapeutic response of brain abscess. Methods : A study was conducted on 10 consecutive patients with brain abscess, Magnetic resonance imaging (MRI) with diffuse-weighted imaging (DWI) was performed at 3 and 6 weeks after surgical treatment and intravenous antibiotics therapy and FOG-PET at 6 weeks after treatment. The extent of the abscess, signal changes on MRI, and FOG-PET standardized uptake values were analyzed and correlated with the response to therapy. Results : Aspiration or craniotomy with excision of the abscess followed by intravenous antibiotics for 6-8 weeks resulted in good recovery with no recurrence. In 10 patients, two had low signal intensity on the DWI; one had no uptake on FOG-PET imaging after 6 weeks antibiotics and discontinued intravenous treatment, but the other patient had diffuse, increased uptake on FOG-PET imaging after 6 weeks antibiotics and underwent an additional 2 weeks of intravenous antibiotics. The remaining eight patients had high signals on the DWI. Four had no uptake on FOG-PET imaging and the treatment period varied from 6 to 8 weeks (mean, 6.75 weeks). Among the other four patients, FOG was accumulated in a diffuse or local area corresponding to a high signal area within the DWI and 2 weeks of intravenous antibiotics was added. Conclusion : MRI plus FOG-PET improved the accuracy of assessing therapeutic responses to antibiotics treatment of brain abscess and aided in optimizing therapy.

Variable uterine uptake of FDG in adenomyosis during concurrent chemoradiation therapy for cervical cancer

  • Yu, Jeong-Il;Huh, Seung-Jae;Kim, Young-Il;Kim, Tae-Joong;Park, Byung-Kwan
    • Radiation Oncology Journal
    • /
    • v.29 no.3
    • /
    • pp.214-217
    • /
    • 2011
  • To avoid improper tumor volume contouring in radiation therapy (RT) and other invasive procedures, we report a case of uterine adenomyosis showing increased $^{18}F$-fluorodeoxyglucose (FDG) uptake on positron emission tomography (PET)/computed tomography (CT) mimicking malignant tumor in a 44-year-old woman during concurrent chemoradiation therapy (CCRT) for uterine cervical cancer. The adenomyosis was not associated with her menstrual cycle or with normal endometrium uptake, and it resolved one month after completion of RT. This case indicates that uterine adenomyosis in a premenopausal woman may show false positive uptake of $^{18}FDG$-PET/CT associated with CCRT.

Software Development for Dynamic Positron Emission Tomography : Dynamic Image Analysis (DIA) Tool (동적 양전자방출단층 영상 분석을 위한 소프트웨어 개발: DIA Tool)

  • Pyeon, Do-Yeong;Kim, Jung-Su;Jung, Young-Jin
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.369-376
    • /
    • 2016
  • Positron Emission Tomography(PET) is nuclear medical tests which is a combination of several compounds with a radioactive isotope that can be injected into body to quantitatively measure the metabolic rate (in the body). Especially, Phenomena that increase (sing) glucose metabolism in cancer tissue using the $^{18}F$-FDG (Fluorodeoxyglucose) is utilized widely in cancer diagnosis. And then, Numerous studies have been reported that incidence seems high availability even in the modern diagnosis of dementia and Parkinson's (disease) in brain disease. When using a dynamic PET iamge including the time information in the static information that is provided for the diagnosis many can increase the accuracy of diagnosis. For this reason, clinical researchers getting great attention but, it is the lack of tools to conduct research. And, it interfered complex mathematical algorithm and programming skills for activation of research. In this study, in order to easy to use and enable research dPET, we developed the software based graphic user interface(GUI). In the future, by many clinical researcher using DIA-Tool is expected to be of great help to dPET research.

The feasibility of algorithm for iterative metal artifact reduction (iMAR) using customized 3D printing phantom based on the SiPM PET/CT scanner (SiPM PET/CT에서 3D 프린팅 기반 자체제작한 팬텀을 이용한 iMAR 알고리즘 유용성 평가에 관한 연구)

  • Min-Gyu Lee;Chanrok Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.35-40
    • /
    • 2024
  • Purpose: To improve the image quality in positron emission tomography (PET), the attenuation correction technique based on the computed tomography (CT) data is important process. However, the artifact is caused by metal material during PET/CT scan, and the image quality is degraded. Therefore, the purpose of this study was to evaluate image quality according to with and without iterative metal artifact reduction (iMAR) algorithm using customized 3D printing phantom. Materials and Methods: The Hoffman and Derenzo phantoms were designed. To protect the gamma ray transmission and express the metal portion, lead substance was located to the surface. The SiPM based PET/CT was used for acquisition of PET images according to application with and without iMAR algorithm. The quantitative methods were used by signal to noise ratio (SNR), coefficient of variation (COV), and contrast to noise ratio (CNR). Results and Discussion: The results shows that the image quality applying iMAR algorithm was higher 1.15, 1.19, and 1.11 times than image quality without iMAR algorithm for SNR, COV, and CNR. Conclusion: In conclusion, the iMAR algorithm was useful for improvement of image quality by reducing the metal artifact lesion.

Noise reduction in low-dose positron emission tomography with adaptive parameter estimation in sinogram domain

  • Kyu Bom Kim;Yeonkyeong Kim;Kyuseok Kim;Su Hwan Lee
    • Nuclear Engineering and Technology
    • /
    • v.56 no.10
    • /
    • pp.4127-4133
    • /
    • 2024
  • Noise reduction in low-dose positron emission tomography (PET) is a well-researched topic aimed at reducing patient radiation doses and improving diagnosis. Software-based noise reduction mainly improves the contrast between regions by reducing the variation of the acquired image. However, it should be performed under appropriate parameters to reduce discrimination. We propose a method that derives optimal noise-reduction parameters using the multi-scale structural similarity index measure and visual information fidelity, which are metrics for image quality assessment. Simulation and experimental studies demonstrated the viability of the proposed algorithm. The contrast-to-noise ratio value of the denoised reconstruction slice, which was used as the optimal parameter, increased approximately three times compared to that of the low-dose slice while preserving the resolution. The results indicate that the proposed method successfully predicted the parameters according to the noise-reduction algorithm and PET system conditions in the sinogram domain. The proposed algorithm should help prevent misdiagnosis and provide standardized medical images for clinical application by performing appropriate noise reduction.

Synthesis of [18F]Fluorocholine Analogues as a Potential Imaging Agent for PET Studies

  • Yu, Kook-Hyun;Park, Jeong-Hoon;Yang, Seung-Dae
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.4
    • /
    • pp.506-510
    • /
    • 2004
  • There have been intensive studies concerning $[^{11}F]$choline ($[^{11}F]$methyldimethyl( ${\beta}$ -hydroxyethyl) ammonium) (1) which is known as a very effective tracer in imaging various human tumors localized in brain, lung, esophagus, rectum, prostate and urinary bladder using Positron Emission Tomography (PET) and there is increasing interest in $^{18}F$ labelled choline (2) and proved to be useful to visualize prostate cancer. We have prepared six $^{18}F$ labelled alkyl choline derivatives (3a-3c, 4a-4c) from ditosylated and dibrominated alkanes in moderate yields. The six alkyl tosylate or bromate ammonium salts have been synthesized as precursors. Radiofluorination was achieved by the treatment of precursors with $^{18}F$ - in the presence of Kryptofix-2.2.2.. The labeling yields varied ranging from 7 to 25%.

Rectified Subspace Analysis of Dynamic Positron Emission Tomography (정류된 부공간 해석을 이용한 PET 영상 분석)

  • Kim, Sangki;Park, Seungjin;Lee, Jaesung;Lee, Dongsoo
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.10d
    • /
    • pp.301-303
    • /
    • 2002
  • Subspace analysis is a popular method for multivariate data analysis and is closely related to factor analysis and principal component analysis (PCA). In the context of image processing (especially positron emission tomography), all data points are nonnegative and it is expected that both basis images and factors are nonnegative in order to obtain reasonable result. In this paper We present a sequential EM algorithm for rectified subspace analysis (subspace in nonnegativity constraint) and apply it to dynamic PET image analysis. Experimental results show that our proposed method is useful in dynamic PET image analysis.

  • PDF

Positron emission tomography and magnetic resonance imaging

  • Yim, Min Su;Ryu, Eun Kyoung
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.2 no.1
    • /
    • pp.3-8
    • /
    • 2016
  • Molecular imaging technologies have been used to provide a new pathway for therapies and diagnosis of human disease. Especially, imaging probes have been much development in the molecular imaging field. Combining imaging probes for positron emission tomography (PET) and magnetic resonance imaging (MRI) have suggested the potential of multiple methods in living body. This review discusses the cancer or lymph node-targeting probes that are suitable for PET/MRI based diagnosis.