• Title/Summary/Keyword: Positive-sequence

Search Result 868, Processing Time 0.033 seconds

PLL for Unbalanced Three-Phase Utility Voltage using Positive Sequence Voltage Observer (정상분 전압 관측기를 이용한 불평형 3상 전원의 PLL)

  • Kim, Hyeong-Su;Choi, Jong-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.145-151
    • /
    • 2008
  • This paper proposes the PLL method using positive sequence voltage which is estimated by full-order state observer to find an accurate phase angle under the condition of unbalanced utility voltage. The proposed method uses the full-order state observer instead of existing method(APF All Pass Filter) to find a positive sequence of a utility voltage and this proposed method improves transient response of an estimated phase angle when a three-phase utility voltage becomes unbalanced. To compare proposed method withexisting method, experiments have been done for a phase angle detection of utility voltage when a three-phase utility voltage becomes unbalanced. Their results show that transient state response of proposed method is improved.

Pulse-Sequence Analysis of Discharges in Air, Liquid and Solid Insulating Materials

  • Suwayno, Suwayno;Mizutani, Teruyoshi
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.4
    • /
    • pp.528-533
    • /
    • 2006
  • Electrical discharges may occur in gas, liquid as well as solid insulating materials. This paper describes the investigation results on the discharges in air, silicone oil and low density polyethylene (LDPE) using needle plane electrode system under AC voltage of 50 Hz. The experimental results showed that for discharge in air (corona), discharge pulses were concentrated around the peak of applied voltage at negative half cycle. For silicone oil positive as well as negative discharges were observed which concentrated around the peak of applied voltage. The positive pulse number was smaller but the magnitude was higher than that of negative discharge. Discharges in void took place at wider range of phase of applied voltage. The unbalance in pulse number and magnitude similar to that of oil discharges were observed. For electrical treeing in LDPE, the discharges were spread before the zero cross of the applied voltage up to the peak at both positive and negative half cycles. The discharge pulse sequence analysis indicated that the PD occurrence in air, oil and void were strongly affected by the magnitude of applied voltage. However, for electrical treeing it was observed that the discharge occurrence was strongly affected by the time derivative of the applied voltage (dv/dt).

Analysis of Instantaneous Voltage Compensator Using 3-Phase PWM Inverter (3상 PWM 인버터를 이용한 순간전압보상기의 해석)

  • 최연규;이승요;최규하;목형수;함형원
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.222-227
    • /
    • 1997
  • Unbalanced source voltages due to unbalanced loads in the 3-phase power system is decomposed into positive, negative and zero sequence components. Also, assuming there is no neutural path in the system, the zero sequence component is not shown. Therefore, it is possible to compensate unbalanced source voltage by canceling the negative sequency component of the voltages of the source. In this paper, an algorithm compensating unbalanced source voltages by canceling the negative sequence component is presented and analysis of instantaneous voltage compensator using 3-phase PWM inverter is carried out through computer simulation.

  • PDF

ON STAR MOMENT SEQUENCE OF OPERATORS

  • Park, Sun-Hyun
    • Honam Mathematical Journal
    • /
    • v.29 no.4
    • /
    • pp.569-576
    • /
    • 2007
  • Let $\cal{H}$ be a separable, infinite dimensional, complex Hilbert space. We call "an operator $\cal{T}$ acting on $\cal{H}$ has a star moment sequence supported on a set K" when there exist nonzero vectors u and v in $\cal{H}$ and a positive Borel measure ${\mu}$ such that <$T^{*j}T^ku$, v> = ${^\int\limits_{K}}\;{{\bar{z}}^j}\;{{\bar{z}}^k}\;d\mu$ for all j, $k\;\geq\;0$. We obtain a characterization to find a representing star moment measure and discuss some related properties.

THE NORM RATIO OF THE POLYNOMIALS WITH COEFFICIENTS AS BINARY SEQUENCE

  • Taghavi, M.
    • Journal of applied mathematics & informatics
    • /
    • v.13 no.1_2
    • /
    • pp.195-200
    • /
    • 2003
  • Given a positive integer q, the ratio of the 2q-norm of a polynomial which its coefficients form a binary sequence and its 2-norm arose from telecommunication engineering consists of finding any type of such polynomials haying the ratio “small” In this paper we consider some special types of these polynomials, discuss the sharpest possible upper bound, and prove a result for the ratio.

DISTRIBUTIONAL CHAOS AND DISTRIBUTIONAL CHAOS IN A SEQUENCE OCCURRING ON A SUBSET OF THE ONE-SIDED SYMBOLIC SYSTEM

  • Tang, Yanjie;Yin, Jiandong
    • Bulletin of the Korean Mathematical Society
    • /
    • v.57 no.1
    • /
    • pp.95-108
    • /
    • 2020
  • The aim of this paper is to show that for the one-sided symbolic system, there exist an uncountable distributively chaotic set contained in the set of irregularly recurrent points and an uncountable distributively chaotic set in a sequence contained in the set of proper positive upper Banach density recurrent points.

A semi-exact in tensor product

  • Bae, Chul-Kon;Lee, Im-Suk;Min, Kang-Joo
    • The Mathematical Education
    • /
    • v.12 no.1
    • /
    • pp.1-3
    • /
    • 1973
  • In this paper, we want to verify some properties in tensor product. It is interesting to think semi-exact sequence in tensor Product by [3]. Moreover no hardness is there in process and we want to discuss the commutativity in tensor product. For a certain semi-exact sequence, if we product arbitrary Abelian group for each group then the tensor Product will do or not. Here, we have positive answer. At first we define the semi-exact sequence as following.

  • PDF

Droop Control Scheme of a Three-phase Inverter for Grid Voltage Unbalance Compensation

  • Liu, Hongpeng;Zhou, Jiajie;Wang, Wei;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1245-1254
    • /
    • 2018
  • The stability of a grid-connected system (GCS) has become a critical issue with the increasing utilization of renewable energy sources. Under grid faults, however, a grid-connected inverter cannot work efficiently by using only the traditional droop control. In addition, the unbalance factor of voltage/current at the common coupling point (PCC) may increase significantly. To ensure the stable operation of a GCS under grid faults, the capability to compensate for grid imbalance should be integrated. To solve the aforementioned problem, an improved voltage-type grid-connected control strategy is proposed in this study. A negative sequence conductance compensation loop based on a positive sequence power droop control is added to maintain PCC voltage balance and reduce grid current imbalance, thereby meeting PCC power quality requirements. Moreover, a stable analysis is presented based on the small signal model. Simulation and experimental results verify the aforementioned expectations, and consequently, the effectiveness of the proposed control scheme.

Isolation and Characterization of Thermophilic Microorganism Producing Starch-hydrolyze Enzyme (한국 토양으로부터 전분가수분해효소를 생산하는 고온성 균주의 선별과 동정)

  • Choi, Wonseok;Bai, Dong-Hoon
    • Food Engineering Progress
    • /
    • v.14 no.1
    • /
    • pp.7-13
    • /
    • 2010
  • A thermophilic microorganism, which is able to hydrolyze starch, was isolated from soil and compost in Korea. It was Gram-positive, rod-shaped, catalase positive, nonmotile, glucose and mannitol fermentative, xylose oxidative, and spore forming microorganism. It also has an ability to hydrolyze casein and gelatin. The color of colony was yellowish white. The sequence of 16S rDNA of strain 2719 showed 99.5% sequence homology with the sequence of 16S rDNA of Bacillus thermoglucosidasius. On the basis of biochemical and physiological properties and phylogenetic analysis, the isolated strain was named as Bacillus thermoglucosidasius 2719.

Robust Circulating Current Control in MMC Under the Unbalanced Voltage Condition (불평형 전압 조건에 강인한 모듈형 멀티레벨 컨버터의 순환전류 억제기법)

  • Moon, Ji-Woo;Park, Jung-Woo;Kang, Dae-Wook;Kim, Jang-Mok
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.996-997
    • /
    • 2015
  • This paper proposes parameter design principle of the sub-module capacitance, Arm inductance and a control method to reduced the circulating currents in modular multilevel converter(MMC) under unbalanced voltage conditions. Under balanced voltage conditions, only negative-sequence circulating currents exist. Consequently, the conventional method has considered only negative-sequence circulating currents in MMC. However, under unbalanced voltage conditions, there are positive-sequence, zero-sequence and negative-sequence circulating currents in MMC. Thus, under unbalanced voltage conditions, a control method should consider these all components. This study proposes the control method to reduced the circulating currents under the unbalanced voltage.

  • PDF