• Title/Summary/Keyword: Positive Pressure

Search Result 1,574, Processing Time 0.034 seconds

Clinical Application of Nasal Intermittent Positive Pressure Ventilation with Bi-level Positive Airway Pressure(BiPAP) (기도 이중 양압(BiPAP)을 이용한 비강 간헐 양압환기의 임상적 적용)

  • Cho, Jae-Youn;Lee, Sang-Youb;Lee, Sang-Hwa;Park, Sang-Myun;Suh, Jung-Kyung;Shim, Jae-Jeong;In, Kwang-Ho;Kang, Kyung-Ho;Yoo, Se-Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.5
    • /
    • pp.723-730
    • /
    • 1995
  • Background: Noninvasive ventilation has been used extensively for the treatment of patients with neuromuscular weakness or restrictive chest wall disorders complicated by hypoventilatory respiratory failure. Recently, noninvasive positive pressure ventilation has been used in patients with alveolar hypoventilation, chronic obstructive pulmonary disease(COPD), and adult respiratory distress syndrome. Sanders and Kern reported treatment of obstructive sleep apnea with a modification of the standard nasal CPAP device to deliver seperate inspiratory positive airway pressure(IPAP) and expiratory positive airway pressure(EPAP). Bi-level positive airway pressure(BiPAP) unlike nasal CPAP, the unit delivers a different pressure during inspiration from that during expiration. The device is similar to the positive pressure ventilator or pressure support ventilation. Method and purpose: Bi-level positive airway pressure(BiPAP) system(Respironics, USA) was applied to seven patients with acute respiratory failure and three patients on conventional mechanical ventilation. Results: 1) Two of three patients after extubation were successfully achieved weaning from conventional mechanical ventilation by the use of BiPAP ventilation with nasal mask. Five of seven patients with acute respiratory failure successfully recovered without use of conventional mechanical ventilation. 2) $PaO_2$ 1hour after BiPAP ventilation in acute respiratory failure patients significantly improved more than baseline values(p<0.01). $PaCO_2$ 1hour after BiPAP ventilation in acute respiratory failure patients did not change significantly more than baseline values. Conclusion: Nasal mask BiPAP ventilation can be one of the possible alternatives of conventional mechanical ventilation in acute respiratory failure and supportive method for weaning from mechanical ventilation.

  • PDF

A Study on Development of Shutoff Operating System of Ultra-High Pressure Positive Displacement Pump (초고압 용적형 펌프의 체절운전시스템 개발에 관한 연구)

  • Min, Se-Hong;Kim, Ho-Chul;Sung, Gi-Chan
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.106-113
    • /
    • 2016
  • Ultra-high pressure positive displacement pump can discharge high pressure water with mass volume, which depends on periodic changes in volume that made by rotation motor. Its high efficiency of discharge is one of the most strong point of positive displacement pump. Due to its simple system structure, it can be miniaturized and lightened. Positive displacement pump can discharge high pressure with stable flow rate, irrespective of pressure fluctuate. This is the reason that positive displacement pump was used instead of centrifugal pump. In this study, shutoff operating system was developed for positive displacement pump to secure safety of high pressure operate. This shutoff system contains controller system, electronic clutch, and relief valve, and each part is mutual supplementation. Speed test was carried out in order to check operation of controller program and electronic clutch and fluid flow, venting experiment of the relief valve. It was confirmed that segment system of ultra-high pressure positive displacement pump is operated.

Development of Dynamic Pressure Calibrator with Positive Step Pressure (정방향 스텝 동압력 교정장치 개발)

  • 최주호;홍성수;우삼용;이경희;김창복
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.155-169
    • /
    • 2001
  • In this paper, dynamic pressure is mainly generated in the closed chamber of gun when the propellant is fired and has exponential pressure motion. Dynamic pressure calibrator with positive step pressure was designed and manufactured to meet the calibration of piezoelectric high pressure transducers which are mainly used to measure dynamic pressure motion in the test of weapon systems. In addition, the results of Performance test and analysis of system uncertainty are provided.

  • PDF

Occurrence Mechanism and Characteristics of Pressure Pulsation in a Positive Displacement Hydraulic Turbine (용적형수차의 압력맥동 발생기구 및 특성에 관한 연구)

  • Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.8
    • /
    • pp.947-953
    • /
    • 2007
  • Occurrence of pressure pulsation in positive displacement hydraulic turbine is one of the principal problems which should be cleared to improve the turbine performance and to put the turbine to practical use. Therefore, present study is tried to examine the occurrence mechanism and characteristics of the pressure pulsation CFD analysis and experimental measurement are implemented in this study to clarify the phenomena of unsteady pressure pulsation. The results show that occurrence reason of the pressure pulsation is not only due to a series of opening and closing of the chamber formed between rotor and casing wall but also due to the variation of rotational speed of following rotor. The pressure pulsation causes torque variation and the curve patterns of the torque variation conforms to that of the pressure pulsation. Pressure in the chamber is equal to the averaged value of inlet and outlet pressures. Sudden pressure decrease by accelerated through-flow between lobe and casing wall results in torque loss.

Responses of Systemic Arterial Blood Pressure and Heart Rates to Graded Increase of Positive Lung Inflation (폐내압증가시(肺內壓增加時)의 동맥혈압(動脈血壓) 및 심박변동(心搏變動)에 관(關)하여)

  • Kim, Kyu-Soo;Oh, Sang-Yu;Choi, Byung-Ok;Lee, Joong-Kil
    • The Korean Journal of Physiology
    • /
    • v.3 no.2
    • /
    • pp.25-31
    • /
    • 1969
  • Effects of graded increase of positive lung inflation upon heart rates and arterial blood pressure were observed in the anesthetized dogs to analyze the mechanical and neural regulatory factor in response to the positive inflation of the lung. The results obtained were summarized as followings: 1) When the low grade of positive lung inflation was employed under the mild to moderate anesthesia, central venous pressure was linearly increased while heart rate was decreased. After bilateral vagotomy, central venous pressure was obviously increased while heart rate was constant. 2) When the high degree of positive lung inflation was employed, changes of central venous pressure and heart rate were not significant. 3) The low grade of intrapulmonary pressure increase caused reflex tachycardia in phase 2 and overshooting in phase 4 in response to the systemic arterial blood pressure change. 4) On the other hand, the high degree of intrapulmonary pressure increase caused paradoxical bradycardia in phase 2 and lack of overshooting in phase 4 in response to the systemic arterial blood pressure change. 5) It may be noted that the experimental model employed in the present study is a useful tool to evaluate and analyze the neural and mechanical regulatory factor in response to the graded increase of the positive lung inflation.

  • PDF

Development of Auto-titrating Algorithm for Auto-titrating Positive Airway Pressure (자동형 양압유지기의 자동적정 알고리즘 개발)

  • Park, Jong-Uk;Urtnasan, Erdenebayar;Kim, Yoon-Ji;Lee, Kyoung-Joung;Lee, Sang-hag
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.4
    • /
    • pp.132-136
    • /
    • 2019
  • This study proposes an auto-titrating algorithm for auto-titrating positive airway pressure (APAP). The process of the proposed algorithm is as follows. First, sleep apnea-hypopnea and snoring events were detected using nasal pressure. Second, APAP base pressure and SDB events were used for automatic titration of optimal pressure. And, auto-titrating algorithm is built into M3 (MEK-ICS CO. Ltd., Republic of Korea) for evaluation. The detection results of SDB showed mean sensitivity (Sen.) and positive predictive value (PPV.) of 85.7% and 87.8%, respectively. The mean pressure and apnea-hypopnea index (AHI) of auto-titrating algorithm showed $13.0{\pm}5.2cmH_2O$ and $3.0{\pm}2.4$ events/h, respectively. And, paired t-test was conducted to verify whether the performance of our algorithm has no significant difference with AutoSet S9 (p>0.05). These results represent better or comparable outcomes compared to those of previous APAP devices.

An Analysis on the Effect of Pressure System Installation on the Pipeline to Identify Pressurized Water and Self-inspection Ease in Apartment Building (아파트에 설치하는 옥내소화전 압력계 설치가 배관의 가압수 식별 및 자체점검 용이성 간의 영향 분석)

  • Son, Joo-Dal;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.1
    • /
    • pp.33-44
    • /
    • 2020
  • This study analyzed how the installation of a pressure gauge in the indoor fire hydrant of an apartment building affected identifying pressurized water in the pipe, making it easier to conduct internal inspection on the fire suppression system, and ensuring reliability of fire suppression. The following are the study's results: First, identifying pressurized water in the indoor firefighting pipe had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that a higher level of identification of pressurized water in the indoor firefighting pipe had a positive impact on improving the installation and use of a pressure gauge in the indoor fire hydrant. Second, making it easier for the fire safety officer to inspect the fire suppression system had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This suggests that if it becomes easier for the apartment building's stakeholder to conduct internal inspection or the firefighting facility manager to carry out inspection on the fire suppression system, it would have a positive effect on the installation of a pressure gauge in the indoor fire hydrant. Finally, ensuring reliability in fire suppression had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that if it becomes easier to identify pressurized water in the indoor firefighting pipe, for the fire safety officer to conduct internal inspection, or for the firefighting facility manager to carry out inspection in accordance with the fire suppression system's internal inspection requirements, it would increase reliability in fire suppression, making it more necessary to install a pressure gauge in the indoor fire hydrant.

Flow Analysis in Positive Displacement Micro-Hydro Turbine and Development of Low Pulsation Turbine

  • Kurokawa, Junichi;Matsui, Jun;Choi, Young-Do
    • International Journal of Fluid Machinery and Systems
    • /
    • v.1 no.1
    • /
    • pp.76-85
    • /
    • 2008
  • In order to extract micro hydropower in the very low specific speed range, a Positive Displacement Turbine (PDT) was proposed and steady performance was determined experimentally. However, the suppression of large pressure pulsation is inevitable for practical application of PDT. The objective of the present study is to reveal the mechanism and the characteristics of pressure pulsation in PDT by use of CFD and to suppress the pressure pulsation. Unsteady CFD analysis has revealed that large pressure pulsation is caused by large variation of rotational speed of the following rotor, while the driving rotor, which is output rotor, keeps constant speed. Here is newly proposed a 4-lobe helical type rotor which can reduce the pressure pulsation drastically and the performance prediction of new PDT is determined.

The Effects of Performance Pressure on Positive Psychological Capital: Focusing on the Moderating Effect of Zhongyong Thinking (성과압박이 긍정심리자본에 미치는 영향: 중용적 사고의 조절효과를 중심으로)

  • Jang, Jun-ho;An, Daniel
    • Journal of Digital Convergence
    • /
    • v.20 no.5
    • /
    • pp.345-349
    • /
    • 2022
  • This study focused on verifying the moderating effect of Zhongyong thinking in the relationship between performance pressure and positive psychology capital. In particular, the main effects of mitigating negative effects through the Zhongyong of Oriental classics were examined. A survey was conducted on employees of local public institutions and private enterprises engaged in manufacturing and service industries. This study was used for analysis a survey on data 239 employees. The major finding are as follows. Performance pressure was found to have a negative effect on positive psychological capital. Also, Zhongyong thinking was found to have a moderating effect that alleviated the negative impact between performance pressure and positive psychological capital. In the conclusion, practical implications, and future research directions were described.

CFD Analysis of Pressure Pulsation and Internal Flow for a Positive Displacement Hydraulic Turbine (CFD에 의한 용적형수차의 압력맥동 및 내부유동 해석)

  • Choi, Young-Do;Kim, You-Taek;Lee, Young-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.687-693
    • /
    • 2007
  • It has been known that one of the main obstacles of improving the performance of positive displacement hydraulic turbine is pressure pulsation which occurs at the regions upstream and downstream of the turbine. In order to suppress the pressure pulsation. occurrence reason of the pressure pulsation should be understood in detail Therefore. this study aims to establish a CFD analysis method by which the phenomena of unsteady pressure pulsation can be examined with high accuracy. Internal flow field of the turbine is modeled simply to generalize the relation between the pressure pulsation and internal flow. The results show that the Present CFD method adopting unsteady calculation can be applied successfully to the analysis of the Phenomena of Pressure Pulsation. Occurrence of the Pressure pulsation is due to the difference of the rotational speed of turbine rotors When driving rotor rotates by uniform speed and fellowing rotor rotates by variable speed, very large Pressure pulsation occurs within the turbine periodically.