• Title/Summary/Keyword: Position registration

Search Result 117, Processing Time 0.027 seconds

The influence of horizontal cephalic rotation on the deviation of mandibular position

  • Katayama, Naoto;Koide, Kaoru;Koide, Katsuyoshi;Mizuhashi, Fumi
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.6
    • /
    • pp.401-407
    • /
    • 2018
  • PURPOSE. When performing an occlusal procedure, it is recommended that the patient should be sitting straight with the head in a natural position. An inappropriate mandibular position caused by an incorrect occlusal record registration or occlusal adjustment can result in damaged teeth and cause functional disorders in muscles and temporomandibular joints. The purpose of this study was to clarify the influence of horizontal cephalic rotation on mandibular position by investigating the three-dimensional positions of condylar and incisal points. MATERIALS AND METHODS. A three-dimensional jaw movement measurement device with six degrees of freedom (the WinJaw System) was used to measure condylar and incisal points. The subjects were asked to sit straight with the head in a natural position. The subjects were then instructed to rotate their head horizontally $0^{\circ}$, $10^{\circ}$, $20^{\circ}$, $30^{\circ}$, $40^{\circ}$, $50^{\circ}$and $60^{\circ}$ in the right or left direction. RESULTS. The results indicated that horizontal cephalic rotation made the condyle on the rotating side shift forward, downward, and toward the inside, and the condyle on the counter rotating side shift backward, upward, and toward the outside. Significant differences in deviations were found for angles of rotation higher than $20^{\circ}$. The incisal point shifted in the forward and counterrotating directions, and significant differences were found for angles of rotation higher than $20^{\circ}$. CONCLUSION. The mandibular position was altered by horizontal cephalic rotations of more than $20^{\circ}$. It is essential to consider the possibility of deviation of the mandibular position during occlusal procedures.

A Web GPS based Logistics Vehicle Control Management System using MVC Design Patterns (MVC 디자인 패턴을 활용한 Web GPS 기반의 물류차량 출하 관제 시스템)

  • Sim, Choon Bo;Kim, Kyoung Jong
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.6 no.1
    • /
    • pp.131-142
    • /
    • 2010
  • In this paper, we propose a web GPS based logistics vehicle control management system using MVC design patterns. The proposed system is designed by applying design patterns of object oriented modeling called mini-architecture to enhance reliability of software as well as promote stability of overall system design. In addition, we can get a position information by means of the GPS embedded in PDA and communicate between client and monitoring server using CDMA network so that the position of client can be identified directly by the map service. The system provides an moving object indexing technique which extends the existing TB-tree to manage and retrieve a transporting trajectory of logistics efficiently. Finally, with development of the logistics vehicle control service called WG-LOGICS system, we can verify the usefulness of our system which is able for monitoring a vehicle preparation, allocating registration, loading a burden, transfer path, and destination arrival in real world.

Esthetic Consideration on Genioplasty (하악골 정중부 수평 골절단술 시행시 심미적 고찰)

  • Cho, Byong-Ouck;Nam, Jong-Hoon;Lee, Young-Ho
    • The Journal of the Korean dental association
    • /
    • v.25 no.9 s.220
    • /
    • pp.847-854
    • /
    • 1987
  • Genioplasty may considerably change a person's face which needs surgical correction of deformed chin. Comprehensive treatment planning is therefore decisive for the treatment to be successful. A three-dimensional analysis of chin relative to cranial base, upper and lower jaws using the frontal and lateral facial photographs and cephalographs permits classification of the defective chin position and provides a basis for operation planning and deciding upon the operation method. A chin miniplate system has been developed for intraoperative registration securing the sagittal, vertical and horizontal position of the osteotomized chin and ould reduce the relapse rate.

  • PDF

Servo Track Writing for Ultra-High TPI Disk Drive in Low Density Medium Condition (초고밀도 디스크 드라이브를 위한 저밀도 작동 환경에서 서보 트랙 기록 방법에 대한 연구)

  • 한윤식;김철순;강성우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.736-741
    • /
    • 2004
  • In high-capacity disk drives with ever-growing track density, the allowable level of position error signal (PES) is becoming smaller and smaller. In order to achieve the high TPI disk drive, it is necessary to improve the writing accuracy during the STW(servo track writing) process through the reduction of TMR sources. Among the main contributors of the NRRO(Non-Repeatable Run-out) PES, the disk vibration and the HSA(head-stack assembly) vibration is considered to be one of the most significant factors. Also the most contributors of RRO(Repeatable Run- out) come from the contributors of NRRO which is written-in at the time of STW(servo track writing) process. In this paper, the experimental test result shows that the effect of NRRO on servo written-in RRO effectively can be reduced through a STW process under low dense medium condition such as semi-vacuum.

  • PDF

3D City Modeling Using Laser Scan Data

  • Kim, Dong-Suk;Lee, Kwae-Hi
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.505-507
    • /
    • 2003
  • This paper describes techniques for the automated creation of geometric 3D models of the urban area us ing two 2D laser scanners and aerial images. One of the laser scanners scans an environment horizontally and the other scans vertically. Horizontal scanner is used for position estimation and vertical scanner is used for building 3D model. Aerial image is used for registration with scan data. Those models can be used for virtual reality, tele-presence, digital cinematography, and urban planning applications. Results are shown with 3D point cloud in urban area.

  • PDF

Usefulness of Registration in the Evaluation of Parkinson′s Disease (영상 융합하여 분석한 파킨슨씨병 환자영상의 유용성)

  • 주라형;김재승;문대혁;최보영;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.268-278
    • /
    • 2003
  • Purpose:The aim of this study was to evaluate the striatal binding ratio, the anterior/posterior ratio and reproducibility using a template based registration method using the standard MR template as a replacement for each patients MR image. Materials and Methods:This study analyzed the 123I IPT SPECT images of 30 patients with IPD, who were subdivided into 17 patients (56.6$\pm$10.8 yr, M/F : 8/9.) with mild IPD, and 13 patients (56.4$\pm$11.1 yr, M/F : 8/5) with severe IPD. In addition, 11 normal controls (57.8$\pm$14.4 yr, M/F : 4/7) were also analyzed. The ROIs were positioned manually in the same slice showing the highest striatal activity using the traditional manual method, whereas those were positioned automatically in a mid striatal slice of the SPECT image coregistered to the standard T1 weighted MR template. Results : The specific binding ratio (SBR) obtained using the template based registration method strongly correlated with those using the manual method in all groups : normal controls (r=0.85, P<0.001), mild IPD (r=0.84, P<0.001) and severe IPD (r=0.7, P=0.01). The SBRs obtained using both methods were significantly different among the three groups (P=0.05) and the SBRs obtained by the template based registration method were higher than those by the manual method (P=0.05) in all three groups. The APRs obtained by the template based registration correlated with those using manual method in only mild IPD (r=0.72, P=0.0). The APRs obtained by the template based registration method were significantly different from the normal controls and those with mild or severe IPD (P<0.05), whereas those obtained using the manual method were not significantly different among the three groups (P>0.1). The reproducibility (rmsCV) of the template based registration method was 7.2% (normal controls:5.2%, mild IPD:4.2%, severe IPD:10.8%), whereas the reproducibility of the manual method was 31% (normal controls:19.7%, mild IPD:21.7%, severe IPD:46.2%). Conclusion:These results show that the use of $^{123}$ I-IPT SPECT for assessing IPD is affected by the methods used to position the striatal ROI. The template based registration method using the standard MR template can be useful in diagnosing IPD and assessing the disease severity with a high reproducibility. Therefore, the template based registration method appears to be a good replacement for the manual method.

  • PDF

A STUDY OF THE OCCLUSAL CONTACT PATTERN DURING MANDIBULAR MOVEMENTS OF ADULT WITH NORMAL OCCLUSION (T-scan을 이용한 성인정상교합자의 하악운동시 치아접촉양상에 관한 연구)

  • Chai Young-Ah;Park Nam-Soo;Choi Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.565-579
    • /
    • 1993
  • This study was accomplished to analyse and compare the occlusal contact patterns during eccentric mandibular movements in adult with normal occlusion. 50 subjects(male 27, female 23), who had natural occlusion and no symptom of temporomandibular disorder, were selected. Teeth contact patterns during mandibular eccentric movements were recorded and the distribution of tooth contacts in maximum intercuspation analysed by T-scan system. And then, tooth contact numbers recored by T-scan and silicone bite registration at centric occlusion were analysed and compared. The results obtained were as follows : 1. Antero-posteriorly, the qualitative center of occlusal contacts in centric occlusion were in the first molar areas, but there was a slight deviation in left-right directions. Thus, distribution of occlusal contacts were not bilaterally symmetric. 2. During the mandibular movements from centric occlusal position to right lateral and left lateral directions, the frequency that maxillary canine joined in lateral guidance was relatively high, but pure canine protected occlusion or pure group function occlusion had small frequency. 3. During mandibular protrusive movement, one or more maxillary central incisors frequently joined in protrusive guidance. 4. During mandibular eccentric movements, working and balancing side premature contact was observered in relatively high frequency. 5. In centric occlusal position, the numbers of occlusal contacts recorded on T-scan were relatively smaller than on silicone bite registration.

  • PDF

Registration and Intensity Compensation of Tilted Images of the Mitochondria Section Obtained from the Transmission Electron Microscopy (미토콘드리아 절편의 여러 투사각에서 투과 전자 현미경으로 획득한 영상의 정합과 밝기 보정)

  • Kim, Dong-Sik
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.3
    • /
    • pp.1-9
    • /
    • 2009
  • Using the projected 2-dimensional tilted images obtained from the transmission electron microscopy, we can reconstruct the 3-dimensional structures of objects, such as cells. As a preprocessing procedure, the tilted images should be registered and compensated in terms of the spatial position and the intensity difference, respectively. In this paper, we employ the fiducial marker-based approach to perform a registration, and introduce a simple intensity compensation scheme. Based on the transmissivity image formation model, we propose an algorithm that can compensate the components of the illumination and transmissivity of each image according to the tilted angle. Numerical analysis using real images obtained from the transmission electron microscopy are shown in this paper to show the performance of the proposed algorithm.

A Study of the Effect of Intangible Asset on Firm Value : Focused on KOSDAQ-Listed Medium-Sized Companies (기업의 무형자산이 기업가치에 미치는 영향에 관한 연구 : 코스닥 상장 중견기업을 중심으로)

  • Yoon, Jeong-Hee;Seo, Inhee;Choi, Jeongil
    • Journal of Information Technology Services
    • /
    • v.15 no.3
    • /
    • pp.1-14
    • /
    • 2016
  • According to the growing importance of science and technology policy, investment in research and development (R&D) has been increased. In this context, a patent as one of outcome of firm's systematic R&D investment is the way to hold a dominant position in companies' technology competitiveness and also to protect technology right. This study attempts to find the effects of input resources and intellectual property production activity on company value. It conducted empirical analysis based on 238 KOSDAQ-listed and medium-sized firms. Using the previous research, this study configurated research variables about activity of patent production, company value, and input of resources. Through these variables, it aims to know the effect of input of resources and activity of patent production on company value. First, the result of regression analysis shows that R&D cost has the positive effect on a patent production and sales promotion cost positively affects on the registration of the trademark. Second, the output of regression analysis indicates that a patent has the positive effect on company value but a trademark has not. With regard to the input of resources, R&D cost has the influence on company value but sales promotion cost has not. This study attempts to find the effectiveness of company's intellectual property registration on its value and suggests a way that the systematic R&D investment contributes the growth of company value.

Self-localization for Mobile Robot Navigation using an Active Omni-directional Range Sensor (전방향 능동 거리 센서를 이용한 이동로봇의 자기 위치 추정)

  • Joung, In-Soo;Cho, Hyung-Suck
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.1 s.94
    • /
    • pp.253-264
    • /
    • 1999
  • Most autonomous mobile robots view only things in front of them, and as a result, they may collide with objects moving from the side or behind. To overcome this problem. an Active Omni-directional Range Sensor System has been built that can obtain an omni-directional range data through the use of a laser conic plane and a conic mirror. Also, mobile robot has to know its current location and heading angle by itself as accurately as possible to successfully navigate in real environments. To achieve this capability, we propose a self-localization algorithm of a mobile robot using an active omni-directional range sensor in an unknown environment. The proposed algorithm estimates the current position and head angle of a mobile robot by a registration of the range data obtained at two positions, current and previous. To show the effectiveness of the proposed algorithm, a series of simulations was conducted and the results show that the proposed algorithm is very efficient, and can be utilized for self-localization of a mobile robot in an unknown environment.

  • PDF