• Title/Summary/Keyword: Position of air inlet

Search Result 50, Processing Time 0.021 seconds

CFD flow analysis of 150mm shower heads depending on plasma pitch (플라즈마 피치에 따른 150mm 샤워헤드에 대한 CFD 유동해석)

  • Kim, Dong-Hwa;Kim, Ho-Bum;Cho, Chong-Du;Jeong, Dea-Kyo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.585-589
    • /
    • 2008
  • This study is performed to analyze the fluid flow about 150mm shower heads of semiconductor device. Under the air pressure, the ideal gas of moving fluid is injected as 5m/s velocity into inlet of shower heads and the flow distribution in shower heads is measured according to pitch of plasma distribution device. As results, the maximum and minimum value of fluid velocity are investigated with their position. The velocity values at outlet are also studied. From two experiment using the plasma distribution device, the results of CFD are compared with the experimental results. That results shows stable flow of fluid in that case of corrected design from CFD.

  • PDF

A study on the performance characteristics of annular-reverse combustor for APU (환형역류형 APU 연소기 성능특성 연구)

  • Lee, Dong-Hun;Choi, Seong-Man;Han, Yeong-Min;Ko, Yeong-Sung
    • 한국연소학회:학술대회논문집
    • /
    • 2001.06a
    • /
    • pp.67-74
    • /
    • 2001
  • The annular-reverse combustor was designed for APU combustor and a three dimensional analysis for reactive flow in the combustor was performed. At the same time, the experimental work was performed in KARl combustor test facility. In this study we found out that tangential swirl type combustor is good for flame holding than single vortex type combustor. The flame tube main hole size and relative position are very important parameters for combustor general performance. The ignition characteristics are strongly depend on the air fuel ratio with combustor inlet volume flow ratio.

  • PDF

AN EXPERIMENTAL STUDY ON THE EFFICIENCY OF A LOCAL VENTILATION SYSTEM AND THE PROTECTING FACE MASKS IN DENTAL LABORATORIES

  • Kim, Uoong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.11 no.1
    • /
    • pp.95-102
    • /
    • 1989
  • This study was performed to study the efficiency of a local ventilation system, installed in dental laboratories, and of two types of protecting face masks. The dust originating from the workpiece as well as from the wheels and stones was collected on air filters in the cutting cycle during coarse and fine grinding, and in the subsequent polishing procedures of each specific dental material. The efficiency of the ventilation system was measured on the basis of weight reduction of dust in the breathing air at a distance about 20-40 cm from workpiece. The results were as follows: 1. Use of the local ventilation system reduced the amounts of respirable dust to an average level of 21.4%, although the efficiency of the local ventilation system varied depending upon materials used. 2. Mounting a nozzle on the tube improved the efficiency of the ventilation system considerably. The efficiency of the local ventilation system also increased as the workpiece was closing to the tube inlet. 3. With or without the local ventilation system, the distance between the position of the workpiece and sampler greatly affected the dust level. 4. The face masks covering the sampler improved the efficiency of the ventilation system considerably.

  • PDF

An Experiment of Natural Circulated Air Flow and Heat Transfer in the Passive Containment Cooling System (격납용기 피동냉각계통내 자연순환 공기유량 및 열전달 실험연구)

  • Ryu, S.H.;Oh, S.M.;Park, G.C.
    • Nuclear Engineering and Technology
    • /
    • v.26 no.4
    • /
    • pp.516-525
    • /
    • 1994
  • Since the TMI and Chernobyl accidents, many passive safety features are suggested in advanced reactors in order to enhance the safety in future nuclear power plants. In order to verify the effectiveness and provide the data for detailed design of passive cooling system, in the present work, the effects of air inlet position and external condition on the natural circulated air flow rate and the natural and forced convective heat transfer coefficient have been investigated for the one-side heated closed path such as the passive containment cooling system of the Westinghouse's AP-600. A series of experiments have been peformed with the 1/26th scaled segment type test facility of the AP-600 passive containment. Under natural and forced convection, the air velocities and temperatures are measured at several points of the air flow path. The experimental result are compared with a simple one-dimensional model and it shows a good agreement.

  • PDF

Numerical Study on Heat Transfer Performance of Crossflow Fin-tube Heat Exchanger Depending on Different Fan Positions (직교류 핀-튜브형 열교환기에서 팬 위치변화에 따른 열전달 성능변화 연구)

  • Kim, Won Hyung;Park, Tae Seon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.3
    • /
    • pp.271-278
    • /
    • 2015
  • The convective heat transfer of a crossflow fin-tube heat exchanger was studied numerically. In order to investigate the dependence of the heat transfer performance on the fan position, several cases with different blowing and suction types were selected for the fan position. A staggered tube arrangement was used for the heat exchanger, and the temperatures of the tube wall and air were $50^{\circ}C$ and $30^{\circ}C$, respectively. The three-dimensional flow structures were examined based on the results. In addition, the convective heat transfer coefficient and mean temperature difference between the inlet and outlet of the heat exchanger were analyzed for the various fan positions, and the heat transfer performance was investigated

Local Concentration and Flame Temperature Characteristics of Combustion Product in Premixed LPG/Air Flames (예혼합 LPG/공기화염에서 연소생성물의 국소농도 및 화염온도특성)

  • 김태권;장준영
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.4
    • /
    • pp.77-84
    • /
    • 2001
  • Measurements of local CO, $CO_2$, $O_2$, $N_2$, $C_3$H$_{8}$, NOx concentrations and flame temperature are made for partially premixed flame with and without acoustic excitation. The CO, $CO_2$, $O_2$, $N_2$, and $C$_3$H_8$ concentrations are determined by thermal conductivity detection (Gas-chromatograph) and NOx concentrations are determined by chemiluminescent detection (NOx analyser). To measure local sample concentration, sampling probe was made by quartz with inlet diameter of 0.25mm. In the case of excitation, the visual shape of the flame is changed from laminar flame to turbulent-like flame. The flame length is also reduced, and the flame width becomes broad. In the observation of emission concentration without acoustic excitation, meanwhile, the $CO_2$ and NOx concentrations peak at flame front where the mixture meets with surrounding air, and the CO concentration is increasing at maximum position of CO2 concentration and peaks at the centerline of the burner. In the case of acoustic excitation, the $CO_2$ concentration is widely occurred at nozzle of the burner and is higher relative to unexcitation. The CO concentration is much reduced, but NOx concentration is more increasing. And flame temperature is higher relative to unexcitation. These are caused by enhancing of mixing with surrounding air due to excitation. However, in the case of acoustic excitation, the total NOx concentration is reduced because of the shortened flame length which affects residence time.e.

  • PDF

A Study on the Surface-Radiation Heat Transfer Characteristics in an Open Cavity with a Heat Source (발열체가 존재하는 개방된 정사각형공간에서 표면복사 열전달 특성에 관한 연구)

  • Nam, Pyoung-Woo;Park, Myoung-Sig;Park, Chan-Woo
    • Solar Energy
    • /
    • v.12 no.3
    • /
    • pp.70-83
    • /
    • 1992
  • The interaction between the surface radiation and the mixed convection transport from an isolated thermal source, with a uniform surface heat flux input and located in a rectangular enclosure, is stuied numerically. The enclosure simulates a practical system such an air cooled electric device, where an air-stream flows through the openings on the two vertical walls. The heat source represents an electric component located in such an enclosure. The size of this cavity is $0.1[m]{\times}0.1[m]$. The inlet velocity is assumed as 0.07[m/s] and the inlet temperature is maintained as $27^{\circ}C$. The inflow is kept at a fixed position. Laminar, two dimensional flow is assumed, and the problem lies in the mixed convection regime, governed by buoyancy force and surface readiation. The significant variables include the location of the out-flow opening, of the heat source and the wall emissivity. The basic nature of the resulting interaction betwwn the externally induced air stream and the buoyancy-driven flow generated by the source is investigated. As a result, the best location of the heat source to make the active heat transfer is 0.075[m] from the left wall on the floor. The trends observed are also discussed in terms of heat removal from practical systems such as electric circuitry.

  • PDF

Transient Response Analysis of a Control Valve for CO2 Refrigerant (CO2냉매용 제어밸브의 응답 특성)

  • Kim, Bo Hyun;Jang, Ji Seong
    • Journal of Drive and Control
    • /
    • v.15 no.4
    • /
    • pp.11-16
    • /
    • 2018
  • Pilot operated control valve for $CO_2$ refrigerant is a valve that can perform various functions according to the user's intention by replacing pilot units, widely used for flow rate, pressure, and temperature control of refrigeration and air conditioning systems. In addition, $CO_2$ refrigerant, that requires high pressure and low critical temperature, can be installed and used in all positions of the refrigeration system, regardless of high or low pressure. In this paper, response characteristics are modeled and analyzed based on behavior of the main piston of the pilot-operated control valve. Although various factors influence operation of the main piston, this paper analyzes the effect of equilibrium pressure depending on valve installation position and application, and inlet and outlet orifice size of the load pressure feedback chamber to determine feedback characteristics of the main piston. As a result, it was possible to quantitatively analyze the effect of change in equilibrium and load pressure feedback chamber flow path size on the change in main piston dynamic and static characteristics.

A Study on the Combustion Flow Characteristics of a Exhaust Gas Recirculation Burner with the Change of Outlet Opening Position (배기가스 재순환 버너에서 연소가스 출구 위치에 따른 연소 유동 특성에 관한 연구)

  • Ha, Ji-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.8-13
    • /
    • 2018
  • Nitrogen oxides (NOx) have recently been very influential in the generation of ultrafine dust, which is of great social interest in terms of improving the atmospheric environment. Nitrogen oxides are generated mainly by the reaction of nitrogen and oxygen in air in a combustion gas atmosphere of high temperature in a combustion apparatus such as thermal power generation. Recently, research has been conducted on the combustion that recirculates the exhaust gas to the cylindrical burner by using a piping using a Coanda nozzle. In this study, three types of burners were carried out through computational fluid analysis. Case 1 burner with the outlet of the combustion gas to the right, Case 2 burner with both sides as gas exit, Case 3 burner with left side gas exit. The pressure, flow, temperature, combustion reaction rate and distribution characteristics of nitrogen oxides were compared and analyzed. The combustion reaction occurred in Case 1 and Case 2 burner in the right direction with combustion gas recirculation inlet and Case 3 burner in the vicinity of mixed gas inlet. The temperature at the outlet was about $100^{\circ}C$ lower than that of the other burners as the Case 2 burner was exhausted to both sides. The NOx concentration of Case 1 burner at the exit was about 20 times larger than that of the other burners. From the present study, it could be seen that it is effective for the NOx reduction to exhaust the exhaust gas to both side gas exits or to exhaust the exhaust gas to the opposite direction of inlet of recirculation gas.

A Study of Heat St Smoke Evacuation Characteristics by the Changing of Operational Method of Tunnel Fan Shaft Ventilation System for Fire on Subway Train Vehicle (지하철 화재시 본선터널 환기시스템에 따른 열 및 연기배출특성)

  • 이동호;유지오
    • Fire Science and Engineering
    • /
    • v.17 no.2
    • /
    • pp.62-69
    • /
    • 2003
  • The smoke control system in subway platform is not only using for smoke exhaust facility but also using ventilation system. For this reason, smoke vent effectiveness is depending on its position, ventilating volume capacity and the vent method. In this study, the passenger's evacuation time was calculated for the case of fire on sloped subway train vehicle in subway platform. In order to recommend the mechanical smoke exhaust operation mode, SES (Subway Environmental Simulation) was used to predict the airflow of the inlet and outlet tunnel for the subway station. Fire dynamics Simulator(FDS) was used the SES's velocity boundary conditions to calculate the smoke density and temperature under the condition of fire on stopped subway train vehicle at the platform. We compared smoke density and temperature distributions for each 6 types of smoke exhaust systems to clarify the characteristics of smoke and hot air exhaust effectiveness from the result of fire simulation.