• Title/Summary/Keyword: Position detection

Search Result 1,500, Processing Time 0.023 seconds

A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring (온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구)

  • Kim, Jung-Yul;Song, Yoon-Ho;Kim, Yoo-Sung
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.4
    • /
    • pp.15-24
    • /
    • 2007
  • Two kinds of temperature monitoring technology have been introduced in this study, which can measure coincidently temperatures at many points along a single length of cable. One is to use a thermal sensor cable comprizing of addressable thermal sensors. The other is to use an optic fiber sensor with Distributed Temperature Sensing (DTS) system. The differences between two technologies can be summarized as follows: A thermal sensor cable has a concept of "point sensing" that can measure temperature only at a predefined position. The accuracy and resolution of temperature measurement are up to the capability of the individual thermal sensor. On the other hand, an optic fiber sensor has a concept of "distributed sensing" because temperature is measured practically at all points along the fiber optic cable by analysing the intensity of Raman back-scattering when a laser pulse travels along the fiber. Thus, the temperature resolution depends on the measuring distance, measuring time and spatial resolution. The purpose of this study is to investigate the applicability of two different temperature monitoring techniques in technical and economical sense. To this end, diverse experiments with two techniques were performed and two techniques are applied under the same condition. Considering the results, the thermal sensor cable will be well applicable to the assessment of groundwater flow, geothermal distribution and grouting efficiency within about loom distance, and the optic fiber sensor will be suitable for long distance such as pipe line inspection, tunnel fire detection and power line monitoring etc.

A Study on Face Contour Line Extraction using Adaptive Skin Color (적응적 스킨 칼라를 이용한 얼굴 경계선 추출에 관한 연구)

  • Yu, Young-Jung;Park, Seong-Ho;Moon, Sang-Ho;Choi, Yeon-Jun
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.3
    • /
    • pp.383-391
    • /
    • 2017
  • In image processing, image segmentation has been studied by various methods in a long time. Image segmentation is the process of partitioning a digital image into multiple objects and face detection is a typical image segmentation field being used in a variety of applications that identifies human faces in digital images. In this paper, we propose a method for extracting the contours of faces included in images. Using the Viola-Jones algorithm, to do this, we detect the approximate locations of faces from images. But, the Viola-Jones algorithm could detected the approximate location of face not the correct position. In order to extract a more accurate face region from image, we use skin color in this paper. In details, face region would be extracted using the analysis of horizontal and vertical histograms on the skin area. Finally, the face contour is extracted using snake algorithm for the extracted face area. In this paperr, a modified snake energy function is proposed for face contour extraction based snake algorithm proposed by Williams et al.[7]

Identifying Analog Gauge Needle Objects Based on Image Processing for a Remote Survey of Maritime Autonomous Surface Ships (자율운항선박의 원격검사를 위한 영상처리 기반의 아날로그 게이지 지시바늘 객체의 식별)

  • Hyun-Woo Lee;Jeong-Bin Yim
    • Journal of Navigation and Port Research
    • /
    • v.47 no.6
    • /
    • pp.410-418
    • /
    • 2023
  • Recently, advancements and commercialization in the field of maritime autonomous surface ships (MASS) has rapidly progressed. Concurrently, studies are also underway to develop methods for automatically surveying the condition of various on-board equipment remotely to ensure the navigational safety of MASS. One key issue that has gained prominence is the method to obtain values from analog gauges installed in various equipment through image processing. This approach has the advantage of enabling the non-contact detection of gauge values without modifying or changing already installed or planned equipment, eliminating the need for type approval changes from shipping classifications. The objective of this study was to identify a dynamically changing indicator needle within noisy images of analog gauges. The needle object must be identified because its position significantly affects the accurate reading of gauge values. An analog pressure gauge attached to an emergency fire pump model was used for image capture to identify the needle object. The acquired images were pre-processed through Gaussian filtering, thresholding, and morphological operations. The needle object was then identified through Hough Transform. The experimental results confirmed that the center and object of the indicator needle could be identified in images of noisy analog gauges. The findings suggest that the image processing method applied in this study can be utilized for shape identification in analog gauges installed on ships. This study is expected to be applicable as an image processing method for the automatic remote survey of MASS.

Characteristics of source localization with horizontal line array using frequency-difference autoproduct in the East Sea environment (동해 환경에서 차주파수 곱 및 수평선배열을 이용한 음원 위치추정 특성)

  • Joung-Soo Park;Jungyong Park;Su-Uk Son;Ho Seuk Bae;Keun-Wha Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.1
    • /
    • pp.29-38
    • /
    • 2024
  • The Matched Field Processing (MFP) is an estimation method for a source range and depth based on the prediction of sound propagation. However, as the frequency increases, the prediction inaccuracy of sound propagation increases, making it difficult to estimate the source position. Recently proposed, the Frequency-Difference Matched Field Processing (FD-MFP) is known to be robust even if there is a mismatch by applying a frequency-difference autoproduct extracted from the auto-correlation of a high frequency signal. In this paper, in order to evaluate the performance of the FD-MFP using a horizontal line array, simulations were conducted in the environment of the East Sea of Korea. In the area of Bottom Bounce (BB) and Convergence Zone (CZ) where detection of a sound source is possible at a long range, and the results of localization were analyzed. According to the the FD-MFP simulations of horizontal line array, the accuracy of localization is similar or degraded compared to the conventional MFP due to diffracted field and mismatch of sound speed. There was no clear result from the simulations conforming that the FD-MFP was more robust to mismatch than the conventional MFP.

Leakage noise detection using a multi-channel sensor module based on acoustic intensity (음향 인텐시티 기반 다채널 센서 모듈을 이용한 배관 누설 소음 탐지)

  • Hyeonbin Ryoo;Jung-Han Woo;Yun-Ho Seo;Sang-Ryul Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.4
    • /
    • pp.414-421
    • /
    • 2024
  • In this paper, we design and verify a system that can detect piping leakage noise in an environment with significant reverberation and reflection using a multi-channel acoustic sensor module as a technology to prevent major plant accidents caused by leakage. Four-channel microphones arranged in a tetrahedron are designed as a single sensor module to measure three-dimensional sound intensity vectors. In an environment with large effects of reverberation and reflection, the measurement error of each sensor module increases on average, so after placing multiple sensor modules in the field, measurement results showing locations with large errors due to effects such as reflection are excluded. Using the intersection between three-dimensional vectors obtained from several pairs of sensor modules, the coordinates where the sound source is located are estimated, and outliers (e.g., positions estimated to be outside the site, positions estimated to be far from the average position) are detected and excluded among the points. For achieving aforementioned goal, an excluding algorithm by deciding the outliers among the estimated positions was proposed. By visualizing the estimated location coordinates of the leakage sound on the site drawing within 1 second, we construct and verify a system that can detect the location of the leakage sound in real time and enable immediate response. This study is expected to contribute to improving accident response capabilities and ensuring safety in large plants.

Midterm Results of the Bioprosthesis in Mitral Position (조직판막을 이용한 승모판 치환술의 중기 성적)

  • Cho, Hyun-Jin;Lee, Jae-Won;Jung, Sung-Ho;Je, Hyoung-Gon;Choo, Suk-Jung;Song, Hyun;Chung, Cheol-Hyun
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.695-702
    • /
    • 2008
  • Background: The choice between a bioprosthetic and a mechanical valve is an important decision in cardiac valve surgery, and the durability of the tissue valve is a major decision factor. We retrospectively evaluated the midterm results of bioprosthetic valve replacement in the mitral position. Material and Method: The subjects were all patients who had undergone mitral bioprosthesis replacement between July 1989 and August 200.7. Among the 216 patients, there were 236 surgical cases. The mean age was $63{\pm}15$ years, and the male to female ratio was 1 : 3. We retrospectively analyzed hospital and outpatient records such that the total follow-up duration amounted to 760.2 patient-years, and the mean follow-up duration was $41.9{\pm}40.7$ months (range $0{\sim}212$ months). Result: Early death occurred in 18 patients (8.3%), and 13 of these underwent concomitant cardiac procedures. The survival rate after 5 years was $79.9{\pm}3.5%$, and the survival rate after 8 years was $65.5{\pm}5.5%$, while freedom from structural valve deterioration (SVD) was $96.2{\pm}2.2%$ at 5 years and $85.9{\pm}5.3%$ at 8 years. Freedom from reoperation was $90.6{\pm}1.7%$ at 5 years and $90.4{\pm}4.2%$ at 8 years, while freedom from reoperation for SVD was $98.1{\pm}1.2%$ at 5 years and $92.3{\pm}4.1%$ at 8 years. On multivariate analysis of preoperative risk factors, small valve size (between 25mm and 27mm) was a significant risk factor for reoperation, and low LV ejection fraction (<40%) was a significant risk factor for SVD and mortality. Conclusion: Survival and freedom from reoperation for SVD in mitral bioprosthesis replacement had acceptable midterm results, but freedom from SVD Was relatively low. In particular, since SVD increased sharply at the eighth postoperative year, frequent follow-up and echocardiograms around that time will be helpful for the early detection of SVD. It will be necessary to conduct further studies involving long-term follow-up and more patients.

The evaluation of dose of TSEI with TLD and diode dector of the uterine cervix cancer (열형광선량계와 반도체검출기를 이용한 전신피부전자선조사의 선량평가)

  • Je Young Wan;Na Keyung Su;Yoon IL Kyu;Park Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2005
  • Purpose : To evaluate radiation dose and accuracy with TLD and diode detector when treat total skin with electron beam. Materials and Methods : Using Stanford Technique, we treated patient with Mycosis Fungoides. 6 MeV electron beam of LINAC was used and the SSD was 300 cm. Also, acrylic speller(0.8 cm) was used. The patient position was 6 types and the gantry angle was 64, 90 and $116^{\circ}$. The patient's skin dose and the output were detected 5 to 6 times with TLD and diode. Result : The deviations of dose detected with TLD from tumor dose were CA $+\;6\%$, thigh $+\;8\%$, umbilicus $+\;4\%$, calf $-\;8\%$, vertex $-\;74.4\%$, deep axillae $-\;10.2\%$, anus and testis $-\;87\%$, sole $-\;86\%$ and nails shielded with 4mm lead $+4\%$. The deviations of dose detected with diode were $-4.5\%{\sim}+5\%$ at the patient center and $-1.1\%{\sim}+1\%$ at the speller. Conclusion : The deviation of total skin dose was $+\;8\%{\sim}-\;8\%$ and that deviation was within the acceptable range(${\pm}\;10\%$). The boost dose was irradiated for the low dose areas(vertex, anus, sole). The electron beam output detected at the sootier was stable. It is thought that the deviation of dose at patient center detected with diode was induced by detection point and patient position.

  • PDF

Annotation Method based on Face Area for Efficient Interactive Video Authoring (효과적인 인터랙티브 비디오 저작을 위한 얼굴영역 기반의 어노테이션 방법)

  • Yoon, Ui Nyoung;Ga, Myeong Hyeon;Jo, Geun-Sik
    • Journal of Intelligence and Information Systems
    • /
    • v.21 no.1
    • /
    • pp.83-98
    • /
    • 2015
  • Many TV viewers use mainly portal sites in order to retrieve information related to broadcast while watching TV. However retrieving information that people wanted needs a lot of time to retrieve the information because current internet presents too much information which is not required. Consequentially, this process can't satisfy users who want to consume information immediately. Interactive video is being actively investigated to solve this problem. An interactive video provides clickable objects, areas or hotspots to interact with users. When users click object on the interactive video, they can see additional information, related to video, instantly. The following shows the three basic procedures to make an interactive video using interactive video authoring tool: (1) Create an augmented object; (2) Set an object's area and time to be displayed on the video; (3) Set an interactive action which is related to pages or hyperlink; However users who use existing authoring tools such as Popcorn Maker and Zentrick spend a lot of time in step (2). If users use wireWAX then they can save sufficient time to set object's location and time to be displayed because wireWAX uses vision based annotation method. But they need to wait for time to detect and track object. Therefore, it is required to reduce the process time in step (2) using benefits of manual annotation method and vision-based annotation method effectively. This paper proposes a novel annotation method allows annotator to easily annotate based on face area. For proposing new annotation method, this paper presents two steps: pre-processing step and annotation step. The pre-processing is necessary because system detects shots for users who want to find contents of video easily. Pre-processing step is as follow: 1) Extract shots using color histogram based shot boundary detection method from frames of video; 2) Make shot clusters using similarities of shots and aligns as shot sequences; and 3) Detect and track faces from all shots of shot sequence metadata and save into the shot sequence metadata with each shot. After pre-processing, user can annotates object as follow: 1) Annotator selects a shot sequence, and then selects keyframe of shot in the shot sequence; 2) Annotator annotates objects on the relative position of the actor's face on the selected keyframe. Then same objects will be annotated automatically until the end of shot sequence which has detected face area; and 3) User assigns additional information to the annotated object. In addition, this paper designs the feedback model in order to compensate the defects which are wrong aligned shots, wrong detected faces problem and inaccurate location problem might occur after object annotation. Furthermore, users can use interpolation method to interpolate position of objects which is deleted by feedback. After feedback user can save annotated object data to the interactive object metadata. Finally, this paper shows interactive video authoring system implemented for verifying performance of proposed annotation method which uses presented models. In the experiment presents analysis of object annotation time, and user evaluation. First, result of object annotation average time shows our proposed tool is 2 times faster than existing authoring tools for object annotation. Sometimes, annotation time of proposed tool took longer than existing authoring tools, because wrong shots are detected in the pre-processing. The usefulness and convenience of the system were measured through the user evaluation which was aimed at users who have experienced in interactive video authoring system. Recruited 19 experts evaluates of 11 questions which is out of CSUQ(Computer System Usability Questionnaire). CSUQ is designed by IBM for evaluating system. Through the user evaluation, showed that proposed tool is useful for authoring interactive video than about 10% of the other interactive video authoring systems.

Rapid Analysis of Nitrate Concentration in Different Growth Stages and Plant Parts of Paprika Leaf Using On-site Rapid Detection Kit (신속분석기기를 이용한 파프리카 생육단계 및 부위별 엽내 질산태질소 농도 신속분석)

  • Lee, Min Ji;Rhee, Han Cheol;Choi, Gyeong Lee;Oh, Sang Seok;Lee, Jae Taek;Lee, Jun Gu
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.333-339
    • /
    • 2017
  • This research was aimed to establish rapid analysis technique for the determination of nitrate ($NO_3{^-}$) concentration in the leaves of paprika, which has key role for the stable vegetative and reproductive growth. Leaf petiole and blade sap of two paprika cultivars ('Raon red' and 'Raon yellow') were used for the determination of $NO_3{^-}$ concentration, separately using rapid detection kit (RQ-flex) and spectroscopy quantification methods. In addition, two paprika cultivars namely, 'Nicole' and 'TP2001' were used to determine the status of $NO_3{^-}$ concentration in leaf of each fruiting group. $NO_3{^-}$ concentration in leaf blade sap and the content in leaf showed significant correlation ($R^2=0.8628$), analysed by RQ-flex and spectroscopy methods, respectively. Furthermore, leaf petiole sap and the content in leaf also showed significant correlation ($R^2=0.6734$) but the relationship was poor compared to leaf blade sap and the leaf content. $NO_3{^-}$ concentration in petiole sap decreased in all the cultivars from early to late fruiting group. The higher concentration in the lower leaves and the continuous decrease towards the upper leaves in the both years were found through the analysis of $NO_3{^-}$ concentration in different leaf position. In addition, daily short-term fluctuation of $NO_3{^-}$ in petiole sap could be rapidly monitored. These results showed that long-term or short-term monitoring by test strip-based rapid analysis technique might be useful tool for the diagnosis of nutritional status for the stable of nutritional management in paprika.

Analysis of the Inter- and Intra-treatment Isocenter Deviations in Pelvic Radiotherapy With Small Bowel Displacement System (Small Bowel Displacement System을 이용한 골반부 방사선조사에서 치료간 및 치료중 중심점 위치변동에 관한 분석)

  • Kim Moon Kyung;Kim Dae Yong;Ahn Yong Chan;Huh Seung Jae;Lim Do Hun;Shin Kyung Hwan;Lee Kyu Chan
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.114-119
    • /
    • 2000
  • Purpose : To evaluate the e지ent and frequency of the inter- and intra-treatment isocenter deviations of the whole pelvis radiation field in using small bowel displacement system (SBDS). Methods and Materials : Using electronic portal imaging device (EPID), 302 postero-anterior 232 lateral portal images were prospectively collected from 11 patients who received pelvic radiation therapy (7 with cervix cancer and 4 with rectal cancer). All patients were treated in prone position with SBDS under the lower abdomen. Five metallic fiducial markers were placed on the image detection unit for the recognition of the isocenter and magnification. After aligning the bony landmarks of the EPID images on those of the reference image, the deviations of the isocenter were measured in right-left (RL), cranio-caudal (CC), and PA directions. Results : The mean inter-treatment deviation of the isocenter in each RL, CC, and PA direction was 1.2 mm ($\pm$ 1.6 mm), 1.0 mm ($\pm$3.0 mm), and 0.9 mm ($\pm$4.4 mm), respectively. Inter-treatment isocenter deviations over 5 mm and 10 mm in RL, CC, and PA direction were 2, 12, 24$\%$, and 0, 0, 5$\%$, respectively. Maximal deviation was detected in PA direction, and was 11.5 mm. The mean intratreatment deviation of the isocenter in RL, CC, and PA direction was 0 mm ($\pm$0.9 mm), 0.1 mm ($\pm$ 1.9mm), and 0 mm ($\pm$1.6 mm), respectively. All intra-treatment isocenter deviations over 5 mm in each direction were 0, 1, 1$\pm$, respectively. Conclusions : As the greatest and the most frequent inter-treatment deviation of the isocenter was along the PA direction, it is recommended to put more generous safety margin toward the PA direction on the lateral fields if clinically acceptable in pelvic radiotherapy with SBDD.

  • PDF