• Title/Summary/Keyword: Position Resolution

Search Result 761, Processing Time 0.034 seconds

Atmospheric Correction and Velocity Aberration for Physical Sensor Modeling of High-Resolution Satellite Images (고해상도 위성영상의 센서모델링을 위한 대기 및 속도 보정)

  • Oh, Jae-Hong;Lee, Chang-No
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.5
    • /
    • pp.519-525
    • /
    • 2011
  • High-resolution earth-observing satellites acquire substantial amount of geospatial images. In addition to high image quality, high-resolution satellite images (HRSI) provide unprecedented direct georegistration accuracy, which have been enabled by accurate orbit determination technology. Direct georegistration is carried out by relating the determined position and attitude of camera to the ground target, i.e., projecting an image point to the earth ellipsoid using the collinearity equation. However, the apparent position of ground target is displaced due to the atmosphere and satellite velocity causing significant georegistration bias. In other words, optic ray from the earth surface to satellite cameras at 400~900km altitude refracts due to the thick atmosphere which is called atmospheric refraction. Velocity aberration is caused by high traveling speed of earth-observing satellites, approximately 7.7 km/s, relative to the earth surface. These effects should be compensated for accurate direct georegistration of HRSI. Therefore, this study presents the equation and the compensation procedure of atmospheric refraction and velocity aberration. Then, the effects are simulated at different image acquisition geometry to present how much bias is introduced. Finally, these effects are evaluated for Quickbird and WorldView-1 based on the physical sensor model.

HVCM (Hybrid Voice Coil Motor) Actuator apply performance improvement through the AUTO Focusing Camera Module (HVCM(Hybrid Voice Coil Motor) Actuator적용을 통한 AUTO Focusing Camera Module 성능개선)

  • Kwon, Tae-Kwon;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.307-309
    • /
    • 2011
  • The recently-released camera modules assembled into high-end handsets generally carry auto focusing function. The resolution size of the camera modules is getting higher, and customers demand more precise and stable auto focusing function. When auto focusing function is getting performed, the camera modules applied to VCM usually have the problems, which are an error of lens focusing position and resolution deviation according to the shift of one's position. For this reason, I propose Hybrid VCM that has an improved structure for a stable work of actuator and higher resolution level.

  • PDF

Simultaneous Detection of Biomolecular Interactions and Surface Topography Using Photonic Force Microscopy

  • Heo, Seung-Jin;Kim, Gi-Beom;Jo, Yong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.402.1-402.1
    • /
    • 2014
  • Photonic force microscopy (PFM) is an optical tweezers-based scanning probe microscopy, which measures the forces in the range of fN to pN. The low stiffness leads proper to measure single molecular interaction. We introduce a novel photonic force microscopy to stably map various chemical properties as well as topographic information, utilizing weak molecular bond between probe and object's surface. First, we installed stable optical tweezers instrument, where an IR laser with 1064 nm wavelength was used as trapping source to reduce damage to biological sample. To manipulate trapped material, electric driven two-axis mirrors were used for x, y directional probe scanning and a piezo stage for z directional probe scanning. For resolution test, probe scans with vertical direction repeatedly at the same lateral position, where the vertical resolution is ~25 nm. To obtain the topography of surface which is etched glass, trapped bead scans 3-dimensionally and measures the contact position in each cycle. To acquire the chemical mapping, we design the DNA oligonucleotide pairs combining as a zipping structure, where one is attached at the surface of bead and other is arranged on surface. We measured the rupture force of molecular bonding to investigate chemical properties on the surface with various loading rate. We expect this system can realize a high-resolution multi-functional imaging technique able to acquire topographic map of objects and to distinguish difference of chemical properties between these objects simultaneously.

  • PDF

Development of Tracking System for Micro Mechanical Part Using Image Processing Technique and 2-Axis Stage (영상처리기법과 2축 스테이지를 이용한 미세부품의 추적 시스템 개발)

  • 표창률;강성훈;전병희
    • Transactions of Materials Processing
    • /
    • v.13 no.3
    • /
    • pp.273-278
    • /
    • 2004
  • This paper subscribes the measurement system that can position the target to measure by moving 2-axis stage, which is controlled by the data from image processing technique. The high resolution camera and lens are used in measurement of micro mechanical part, but the region of measurement is very small. It is necessary the re-positioning to measure several regions in one part. The system described in this paper has the accuracy with about $0.9\mu\textrm{m}$ resolution per one pixel and can be applied to measure micro mechanical part.

A Study on the X-ray Diffraction of the Muscle by the Electrical Stimulation (근육의 전기자극에 의한 X선 회절 분석연구)

  • 김덕술;송주영
    • Journal of Life Science
    • /
    • v.8 no.4
    • /
    • pp.373-380
    • /
    • 1998
  • A considerable change observed in X-ray diffraction during the muscle contraction was that the movement of myosin head and conformational change of contractile monecules were occurred in the muscle contraction. Time slice requires tension peak after the onset of stimulation and the height of tension peak depends on the number of twitch cycle. The intensity of I$_{11}$, I$_{10}$, 143${\AA}$ reflection is measured with 5ms time resolution and is recorded in isometric tension. The peak height of I$_{11}$ and 143${\AA}$ intensity is changed after the onset of a stimulation I$_{i}$, and the length of twitch is shortened by successive twitches in the case of stimulation TI$_{i}$. On the other hand, the peak height of I$_{11}$ and 215${\AA}$ intensity starts to decrease at the 1st twitch and remains constant at low peak hight without appreciable recovery during the contraction term. In the case of uccessive twitch stimulation, the myosin heads of muscle are once moved from their resting position and never returned to their initial position.

  • PDF

A Study of AF Focusing algorithm for camera module (소형 카메라 모듈의 오토 포커싱 알고리즘에 관한 연구)

  • An, Jong-Su;Kim, Young-Gil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.320-323
    • /
    • 2011
  • The compact camera assembled into Smart phone is required to have higher resolution level in non AF state than existing handsets, and it is also requested to have higher degree of accuracy, more consistent repetitiveness, and faster auto focusing speed. Algorithm based on a mechanical position of the existing actuator has been discussed. Therefore, in this thesis I suggest an improved algorithm concerning the problem of unstable resolution level in non AF state and auto focusing speed.

  • PDF

Design & Analysis of an Error-reduced Precision Optical Triangulation Probes (오차 최소화된 정밀 광삼각법 프로브의 해석 및 설계)

  • Kim, Kyung-Chan;Oh, Se-Baek;Kim, Jong-Ahn;Kim, Soo-Hyun;Kwak, Yoon-Keun
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.411-414
    • /
    • 2000
  • Optical Triangulation Probes (OTPs) are widely used for their simple structure. high resolution, and long operating range. However, errors originating from speckle, inclination of the object, source power fluctuation, ambient light, and noise of the detector limit their usability. In this paper, we propose new design criteria for an error-reduced OTP. The light source module for the system consists of an incoherent light source and a multimode optical fiber for eliminating speckle and shaping a Gaussian beam Intensity profile. A diffuse-reflective white copy paper, which is attached to the object, makes the light intensity distribution on the change-coupled device(CCD). Since the peak positions of the intensity distribution are not related to the various error sources, a sub-pixel resolution signal processing algorithm that can detect the peak position makes it possible to construct an error-reduced OTP system

  • PDF

Development of Piezo-Eloectric Micro-Depth Control System (압전소자에 의한 미세이송시스템의 개발에 관한 연구)

  • 김동식
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1995.03a
    • /
    • pp.40-62
    • /
    • 1995
  • A micro positioning system using piezoelectric actuators have very wide application region such as ultra-precision machine tool optical device measurement system. In order to keep a high precision displacement resolution it to useful to take a position sensor and feedback of the error. From the practical point of view high-resolution displacement sensor systems are very expensive and it is difficult to make such a sensitive sensor work properly in a poor operational environment of industry. In this study a piezo-electric micro-depth control system which does not require position sensor but piezoelectric voltage feedback has been developed. It is driven by hysteresis-considering reference input voltage calculated in advance and actuator/sensor characteristics of piezoelectric materials. From the result of experiments a fast and stable response of micro-depth control system has been achieved and an efficient technique to control the piezoelectric actuator suggested.

  • PDF

A Study on the Evaluation of Interpolation Methods in PIV (PIV에서의 보간기법의 평가에 관한 연구)

  • 최장운;조대한;최민선;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.90-100
    • /
    • 1996
  • To maintain high spacial accuracy and rapid CPU time in interpolating data from grid to random position or inversely in PIV, proposed many technuques are compared and discussed mainly in terms of interpolating error and computing time. And artificial PIV atmosphere data is furnished by CFD result. First, for interpolation from grid to random position, multiquadric method gives the highest accuracy with the longest CPU time and Taylor series expansion methods give reasonable accuracy with less calculating load. Secondly, the sub-pixel resolution analysis in estimating the coordinates of the maximum correlation coefficients essential in the grey level correlation PIV reveal that 8-neighbours 2nd-order least square interpolation gives utmost accuracy in terms of the real flow conditions.

  • PDF

A Study on the Evaluation of Interpolation Methods in PIV (PIV에서의 보간기법의 평가에 관한 연구)

  • Choi, J.W;Cho, D.H;Choi, M.S;Lee, Y.H
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.412-412
    • /
    • 1996
  • To maintain high spacial accuracy and rapid CPU time in interpolating data from grid to random position or inversely in PIV, proposed many technuques are compared and discussed mainly in terms of interpolating error and computing time. And artificial PIV atmosphere data is furnished by CFD result. First, for interpolation from grid to random position, multiquadric method gives the highest accuracy with the longest CPU time and Taylor series expansion methods give reasonable accuracy with less calculating load. Secondly, the sub-pixel resolution analysis in estimating the coordinates of the maximum correlation coefficients essential in the grey level correlation PIV reveal that 8-neighbours 2nd-order least square interpolation gives utmost accuracy in terms of the real flow conditions.