• 제목/요약/키워드: Position Measurement

검색결과 2,285건 처리시간 0.033초

Realization of High Precision Position Measurement System Using M-sequence Encoded Laser Beam Scanning

  • Takayama, Jun-ya;Shinji Ohyama;Akira Kobayashi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.107.5-107
    • /
    • 2001
  • In this report, as the active position measurement system, a new method for two-dimensional position measurement system using a concept of semi-open type signal field has proposed. The feature of this system is realizing a position measurement only by scanning the encoded laser beams from scanning points to a measurement field, and observed it. First, both system configuration and encoding method are considered concretely, and M-sequence signal is selected for encoding. Next system design is performed to realize the theoretical measurement accuracy, and applied to a position measurement experiments. Experimental results show that measurement precision is larger than theoretical values. Furthermore, method for improving the measurement ...

  • PDF

위치(位置) 측정장치(測定裝置)를 이용한 트랙터의 자동(自動) 주행장치(走行裝置) (Automatic Guidance System for Tractor based upon Position-measurement Systems)

  • 최창현
    • Journal of Biosystems Engineering
    • /
    • 제15권2호
    • /
    • pp.79-87
    • /
    • 1990
  • An automatic guidance system based upon two position-measurement systems was designed to record where the tractor traveled and to guide the tractor along the predetermined path. An algorithm, using the kinematic behavior of tractor movement, was developed to determine the steering angle to reduce lateral position error. The algorithm was based upon constant travel speed, constant steering rate, and zero slip angles of the tractor wheels. The algorithm was evaluated through use of computer simulation and verified in field experiments. Results showed that the distance interval between position measurements was an important factor in guidance system performance. The position-measurement error of the guidance system must be less than 5 cm to be acceptably precise for field operations. An algorithm based upon a variable steering rate might improve the stability of the guidance system. More accurate measurement of tractor position and yaw angle, and faster error processing are required to improve the field performance of the guidance system.

  • PDF

Measurement of Uncertainty Using Standardized Protocol of Hand Grip Strength Measurement in Patients with Sarcopenia

  • Ha, Yong-Chan;Yoo, Jun-Il;Park, Young-Jin;Lee, Chang Han;Park, Ki-Soo
    • 대한골대사학회지
    • /
    • 제25권4호
    • /
    • pp.243-249
    • /
    • 2018
  • Background: The aim of this study was to determine the accuracy and error range of hand grip strength measurement using various methods. Methods: Methods used for measurement of hand grip strength in 34 epidemiologic studies on sarcopenia were analyzed. Maximum grip strength was measured in a sitting position with the elbow flexed at 90 degrees, the shoulder in 0 degrees flexion, and the wrist in neutral position (0 degrees). Maximum grip strength in standing position was measured with the shoulder in 180 degrees flexion, the elbow fully extended, and the wrist in neutral position (0 degrees). Three measurements were taken on each side at 30 sec intervals. The uncertainty of measurement was calculated. Results: The combined uncertainty in sitting position on the right and left sides was 1.14% and 0.38%, respectively, and the combined uncertainty in standing position on the right and left sides was 0.35 and 1.20, respectively. The expanded uncertainty in sitting position on the right and left sides was 2.28 and 0.79, respectively, and the expanded uncertainty in standing position on the right and left sides was 0.71 and 2.41, respectively (k=2). Conclusions: Uncertainty of hand grip strength measurement was identified in this study, and a significant difference was observed between measurement. For more precise diagnosis of sarcopenia, dynamometers need to be corrected to overcome uncertainty.

시각장애 아동과 정상 아동의 선자세 균형 비교 (The Comparison Between Blind and Normal Children in Standing Position)

  • 김중선;이정순
    • The Journal of Korean Physical Therapy
    • /
    • 제15권1호
    • /
    • pp.119-154
    • /
    • 2003
  • In this paper, the proprioceptive sensitivity was compared by Foot-Hand task method and the effect of the proprioceptive sensitivity and auditory to the standing position between blind and normal children was measured using BPM for 56 children in 7, 8, 9 and 10 years old. There are three measurement methods are used for BPM : Rest, Forward Looking, 'Sound' position. The following conclusions were obtained from the above measurements. 1. In comparison of proprioceptive sensitivity between blind and normal children, there is no significant difference(p > .05). There is no significant difference in comparison of each age group and also there is no difference in each gender group(p > .05). 2. In comparison of standing position measurement between blind and normal children, there is any difference (p > .05) in three measurement(Rest, Forward Looking, 'Sound' position) but there is no significant difference in each gender difference(p > .05). There is any difference between Rest and 'Sound' position of blind children, also there is any difference between Forward Looking and ' Sound ' position, rest and 'Sound' position of normal children(p > .05). 3. There is no significant difference of correlation between proprioceptive sensitivity test and standing position measurement in Pearson correlation coefficient(p > .05).

  • PDF

박판 변형률 측정 오차의 보정에 관한 연구 (Study on the Compensation of Strain Measurement Error in Sheet Metals)

  • 차지혜;금영탁
    • 소성∙가공
    • /
    • 제13권7호
    • /
    • pp.594-599
    • /
    • 2004
  • In the sheet metal forming operations, the strain measurement of sheet panel is an essential work which provides the formability information needed in die design, process design, and product inspection. To measure efficiently complex geometry strains, the 3-dimensional automative strain measurement system, which theoretically has a high accuracy but practically has about 3~5% strain error, is often used. For eliminating the strain error resulted in measuring the strains of formed panels using an automated strain measurement system, the position error calibration method is suggested, which computes accurate strains using the grids with accurate nodal coordinates. The accurate nodal coordinates are calculated by adding the nodal coordinates measured by the measurement system and the position error found using the multiple regression method as a function of the main error parameters obtained from the analysis of strain error in a standard cube. For the verification, the strain distributions of square and dome cups obtained from the position error calibration method are compared with those provided by the finite element analysis and ASAME.

박판성형 변형률 측정 오차보정에 관한 연구 (Study on the Error Compensation in Strain Measurement of Sheet Metal Forming)

  • 한병엽;차지혜;금영탁
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 춘계학술대회논문집
    • /
    • pp.270-273
    • /
    • 2003
  • The strain measurement of the panel in the sheet metal forming is essential work which provides experimental data needed to die design, process design, and product inspection. To measure efficiently the complex geometry strain, the 3-dimensional automative strain measurement system, which has high accuracy in theory, but has some 3∼5% errors in practice, is often used. The object of this study is to develop the error compensation technology to eliminate the strain, errors resulted when formed panels are measured using an automated strain measurement system. To achieve the study object, the position error calibration method correcting coordinates of the grid node recognized by a camera using error functions is suggested. Then the position errors were found by calculating the difference in the position of the cube node between real coordinates and measured coordinates in toms of node coordinates and the error calibration equations were derived by regressing the position errors. In order to show the validation of the suggested position error calibration method, finite element analysis and current calibration method was performed for the initial-blankformed.

  • PDF

GPS를 이용한 위치검지시스템 개발 (Development of Position Detection System using GPS)

  • 한영재;목진용;김기환;김석원;은종필
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1729-1734
    • /
    • 2007
  • Recently, as the feasibility study shows that trans-Korea railway and trans-continental railway are advantageous, interest in high-speed railway system is increasing. Because railway vehicle is environment-friendly and safe compared with airplane and ship, its market-sharing increases gradually. We developed a measurement system for on-line test and evaluation of performances of KHST. The measurement system is composed of software part and hardware part. Perfect interface between multi-users is possible. Nowadays, position data inputs to pulse signal from wheel. Perfect position measurement was limited to slip and slide of vehicle. This measurement makes up for the weak points, Position Detection System using GPS develops. By using the system, Korean High Speed Train is capable of accurate fault position detection.

  • PDF

발목관절 복합체의 가동범위 측정을 위한 중립위치와 측정방법의 신뢰도 (Reliability of the Joint Neutral Position and Measurement Methods of the Ankle Joint Complex Range of Motion)

  • 홍완성;김기원
    • The Journal of Korean Physical Therapy
    • /
    • 제23권4호
    • /
    • pp.45-51
    • /
    • 2011
  • Purpose: To determine the correct measurement methods of the ankle joint complex range of motion for measuring the neutral position and evaluate the rater reliability. In addition, the impact of training on the rater reliability was also assessed. Methods: The subjects were eleven healthy women, who were evaluated by two physical therapists and one physical therapist recorded the results of the study. Standard goniometer was used as the measurement tool. The ankle and subtalar joint neutral position and the active range of motion of the ankle and subtalar joint were measured. Intra-rater reliability and inter-rater reliability measures were analyzed with intraclass correlation coefficients. Results: Intra-rater reliability and inter-rater reliability ranged from high to medium for the neutral position of the ankle joint complex. Intra-rater reliability for dorsiflexion and plantarflexion measurements was medium, while the inter-rater reliability was high. The range of motion of the subtalar joint was measured, and the intra-rater reliability and inter-rater reliability were low and medium, respectively Also, the intra-rater reliability was increased with formal training of the measurement techniques. Intra-rater reliability was reduced in case the raters had not undertaken the training. Conclusion: In summary, the results obtained with the measurement tools and joint measurement of position, indicate the consistency of repeated measurements made by the same observers. Under the same circumstances along with repetition of the same measurement technique during training caused an increase in the rater reliability of formally trained raters.

휴대용 휘도측정시스템의 측정각도기반 휘도보정알고리즘 (Luminance Correction Algorithm Based on Measuring Angle for the Portable Luminance Measurement System)

  • 선은혜;김동연;김용태
    • 한국지능시스템학회논문지
    • /
    • 제26권4호
    • /
    • pp.321-326
    • /
    • 2016
  • 본 논문에서는 휴대용 휘도측정시스템의 측정위치기반 휘도보정알고리즘을 제안한다. 측정거리와 측정각도에 따라 휘도 값은 변화하며, 측정거리와 측정각도를 고려한 알고리즘을 적용하여 기존에 개발된 영상기반 휘도측정시스템의 오차를 개선한다. 카메라 영상기반의 휘도 정보를 정확하게 획득하는 면측정방법을 제안하기 위해서 점휘도계로 측정대상물과의 측정각도에 따른 휘도 값의 변화를 측정한다. 측정거리, 측정각도와 휘도 값 간의 연관성을 수식으로 나타내었고, 측정위치를 고려한 알고리즘을 제안한다. 실험용 간판을 대상으로 점휘도계와 제안한 휘도측정시스템을 비교 평가 실험하고 제안한 휘도측정시스템의 성능을 검증하였다.

Sensor Nodes Localization for Temperature Distribution Measurement System

  • Ohyama, Shinji;Alasiry, Ali Husein;Takayama, Junya;Kobayashi, Akira
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1781-1786
    • /
    • 2005
  • In sensor network systems, all the nodes are interconnected and the positional information of each sensor is essential. To measure the temperature, position detection and communication functions are required. Many sensor nodes are distributed to a measurement field, and these sensors have three main functions: they measure the distance to the other nodes, the data of which are used to determine the position of each node; they communicate with other nodes; and they measure the temperature of each node. A novel range measurement method using the difference between light and sound propagation speed is proposed. The experimental results show the temperature distribution as measured with the aid of the determined positions. The positions of every node were calculated with a PC program. Eight nodes were manufactured and their fundamental functions were tested. The results of the range measurement method, which takes relatively accurate measurements, contribute significantly to the accuracy of the position determination. Future studies will focus on 3-D position determination and on the architecture of appropriate sensors and actuators.

  • PDF