• Title/Summary/Keyword: Portal film

Search Result 46, Processing Time 0.025 seconds

The analysis of radiatin field accuracy in uterine cervical cancer patients using verification films. (조사야 확인용 film을 이용한 자궁 경부암 환자의 조사야 정확성 연구)

  • Jung Hee-Young;Kweon Young-Ho;Jeong Deok-Yang;Whang Woong-Ku;Kim You-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.133-145
    • /
    • 1995
  • 1. Purpose : 30 patients with uterine cervical cancer who had been treated at Department of radiation Oncology of Korea university Hospital from June, 1, 1994. to December. 31, 1994. were analyzed to the radiation field accuracy using verification films. 2. Methods and Materials : 30 patients were divided by 6 groups, 5 patients respectively : Group (1) : Standard physique, supine not-fixed Group (2) : Standard physique, supine fixed Group (3) : Obesity physique, supine, not-fixed Group (4) : Obesity physique, supine, not-fixed Group (5) : Obesity physique, prone, not-fixed Group (6) : Obesity physique, prone, fixed All groups were taken verification fimls during the whole treatment period, and it compared with simulation films and portal fimls, 3. Results : This results suggest that all patients should be immovilized and especially obesity physique patients should be treated by prone position in order to reduce radiation field discrepancy. In addition, this results should help to prescribe appropriate safty margins for patients simulation.

  • PDF

Multi-layer design of Hybrid method for digital X-ray imaging (디지털 X-ray imaging을 위한 Hybrid 방식의 다층구조 설계)

  • Cho, Sung-Ho;Park, Ji-Koon;Lee, Dong-Gil;Kim, Dae-Hwan;Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.75-78
    • /
    • 2003
  • In recent years, there has been keen interest in developing flat panel detectors for all modalities of radiology, including gerneral radiology, fluoroscopy, electronic portal imaging, and mammography. In this paper, we report the new hybrid x-ray detector consisted of ZnS(Ag) photoemission layer and a-Se photoconductor layer to resolve problem of conventional x-ray detector such as the direct detector and the indirect detector. To design the structure of ZnS(Ag)/a-Se detector, the penetrated energy spectrum and absorption fraction was estimated using MCNP 4C code. Also, we carried out the experiment to demonstrate the result of MCNP 4C code. Experimental results showed that the absorption fraction of $500{\mu}m$-ZnS(Ag) film was above 87%, 75% at 60 and 80 kVp. As a results, we can determined the thickness of suitable phosphor and the thickness of photoconductor.

  • PDF

The Output Factor of Small Field in Multileaf Collimator of 6 MV Photon Beams (다엽제한기 소조사면의 6 MV 광자선 출력선량계수)

  • Lee, Ho Joon;Choi, Tae-Jin;Oh, Young Kee;Jeun, Kyung Soo;Lee, Yong Hee;Kim, Jin Hee;Kim, Ok Bae;Oh, Se An;Kim, Sung Kyu;Ye, Ji Woon
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • The IMRT is proper implement to get high dose deliver to tumor as its shape and selective approach in radiation therapy. Since the IMRT is performed as modulated the radiation fluence by the MLC created the open shapes and its irradiation time, the dose of segment of radiation field effects on the cumulated portal dose. The accurate output factor of small and step shape of segment is important to improve the determination of deliver tumor dose as it is directly proportional to dose. This experiment performed with the 6 MV photon beam of Clinac Ex(Varian) from $3{\times}3cm^2$ to $0.5{\times}0.5cm^2$ small field size for collimator jaw in MLC free and/or for MLC open field in fixed collimator jaw $10{\times}10cm^2$ using the CC01 ion chamber, SFD diode, diamond detector and X-Omat film dosimetry. As results of normalized to the reference field of $10{\times}10cm^2$ of MLC, the output factor of $3{\times}3cm^2$ showed $0.899{\pm}0.0106$, $0.855{\pm}0.0106$ for $2{\times}2cm^2$, $0.764{\pm}0.0082$ for $1{\times}1cm^2$ and $0.602{\pm}0.0399$ for $0.5{\times}0.5cm^2$. The output factor of MLC open field has shown a maximum 3.8% higher than that of the collimator jaw open field.

Sentiment Analysis of movie review for predicting movie rating (영화리뷰 감성 분석을 통한 평점 예측 연구)

  • Jo, Jung-Tae;Choi, Sang-Hyun
    • Management & Information Systems Review
    • /
    • v.34 no.3
    • /
    • pp.161-177
    • /
    • 2015
  • Currently, the influence of the Internet portal sites that can make it quick and easy to contact the vast amount of information is increasing. Users can connect the Internet through a portal to obtain information, such as communication between Internet users, which can be used to meet a variety of purposes. People are exposed to a variety of information from other users in the search for a movie and get information. The impact on the reviews and ratings with the limited number of characters of the film allows users to form a relationship to the movie, decide whether you want to see the movie or find another movie. but, the user can not read the whole movie review. When user see the overall evaluation, the user can receive the correct information. This research conducted a study on the prediction of the rating by the use of review data. Information of reviews, is divided into two main areas: the"fact" and "opinion". "Fact" is to convey the dispassionate information and "Opinion" is, to represent the user's feelings. In this study, we built sentiment dictionary based on the assessment and evaluation of the online review and applied to evaluate other movies. In the comparative study with a simple emotion evaluation technique, we found the suggested algorithm got the more accurate results.

  • PDF

Radiation Therapy Using M3 Wax Bolus in Patients with Malignant Scalp Tumors (악성 두피 종양(Scalp) 환자의 M3 Wax Bolus를 이용한 방사선치료)

  • Kwon, Da Eun;Hwang, Ji Hye;Park, In Seo;Yang, Jun Cheol;Kim, Su Jin;You, Ah Young;Won, Young Jinn;Kwon, Kyung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.75-81
    • /
    • 2019
  • Purpose: Helmet type bolus for 3D printer is being manufactured because of the disadvantages of Bolus materials when photon beam is used for the treatment of scalp malignancy. However, PLA, which is a used material, has a higher density than a tissue equivalent material and inconveniences occur when the patient wears PLA. In this study, we try to treat malignant scalp tumors by using M3 wax helmet with 3D printer. Methods and materials: For the modeling of the helmet type M3 wax, the head phantom was photographed by CT, which was acquired with a DICOM file. The part for helmet on the scalp was made with Helmet contour. The M3 Wax helmet was made by dissolving paraffin wax, mixing magnesium oxide and calcium carbonate, solidifying it in a PLA 3D helmet, and then eliminated PLA 3D Helmet of the surface. The treatment plan was based on Intensity-Modulated Radiation Therapy (IMRT) of 10 Portals, and the therapeutic dose was 200 cGy, using Analytical Anisotropic Algorithm (AAA) of Eclipse. Then, the dose was verified by using EBT3 film and Mosfet (Metal Oxide Semiconductor Field Effect Transistor: USA), and the IMRT plan was measured 3 times in 3 parts by reproducing the phantom of the head human model under the same condition with the CT simulation room. Results: The Hounsfield unit (HU) of the bolus measured by CT was $52{\pm}37.1$. The dose of TPS was 186.6 cGy, 193.2 cGy and 190.6 cGy at the M3 Wax bolus measurement points of A, B and C, and the dose measured three times at Mostet was $179.66{\pm}2.62cGy$, $184.33{\pm}1.24cGy$ and $195.33{\pm}1.69cGy$. And the error rates were -3.71 %, -4.59 %, and 2.48 %. The dose measured with EBT3 film was $182.00{\pm}1.63cGy$, $193.66{\pm}2.05cGy$ and $196{\pm}2.16cGy$. The error rates were -2.46 %, 0.23 % and 2.83 %. Conclusions: The thickness of the M3 wax bolus was 2 cm, which could help the treatment plan to be established by easily lowering the dose of the brain part. The maximum error rate of the scalp surface dose was measured within 5 % and generally within 3 %, even in the A, B, C measurements of dosimeters of EBT3 film and Mosfet in the treatment dose verification. The making period of M3 wax bolus is shorter, cheaper than that of 3D printer, can be reused and is very useful for the treatment of scalp malignancies as human tissue equivalent material. Therefore, we think that the use of casting type M3 wax bolus, which will complement the making period and cost of high capacity Bolus and Compensator in 3D printer, will increase later.

Dosimetric Influence of Implanted Gold Markers in Proton Therapy for Prostate Cancer (전립선암에 대한 양성자치료에서 금마커에 의한 방사선 선량분포의 영향)

  • Kwak, Jung-Won;Shin, Jung-Wook;Kim, Jin-Sung;Park, Sung-Yong;Shin, Dong-Ho;Yoon, Myong-Geun;Park, So-Ah;Kim, Dong-Wook;Lim, Young-Gyeung;Lee, Se-Byeong
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.291-297
    • /
    • 2010
  • This study examined the dosimetric influence of implanted gold markers in proton therapy and the effects of their positions in the spread-out Bragg peak (SOBP) proton beam. The implanted cylindrical gold markers were 3 mm long and 1.2 mm in diameter. The dosimetric influence of the gold markers was determined with markers at various locations in a proton-beam field. Spatial dose distributions were measured using a three-dimensional moving water phantom and a stereotactic diode detector with an effective diameter of 0.5 mm. Also, a film dosimetry was performed using Gafchromic External Beam Treatment (EBT) film. The GEANT4 simulation toolkit was used for Monte-Carlo simulations to confirm the measurements and to construct the dose-volume histogram with implanting markers. Motion data were obtained from the portal images of 10 patients to investigate the effect of organ motions on the dosimetric influence of markers in the presence of a rectal balloon. The underdosed volume due to a single gold marker, in which the dose was less than 95% of a prescribed amount, was 0.15 cc. The underdosed volume due to the presence of a gold marker is much smaller than the target volume. However, the underdosed volume is inside the gross tumor volume and is not smeared out due to translational prostate motions. The positions of gold markers and the conditions of the proton-beam field give different impacts on the dose distribution of a target with implanted gold markers, and should be considered in all clinical proton-based therapies.

The error analysis of field size variation in pelvis region by using immobilization device (고정기구의 사용이 골반부위 방사선조사영역의 변화에 미치는 오차분석)

  • Kim, Ki-Hwan;Kang, No-Hyun;Bim, Dong-Wuk;Kim, Jun-Sang;Jang, Ji-Young;Kim, Yong-Eun;Kim, Jae-Sung;Cho, Moon-June
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2000
  • In radiotherapy, it may happen to radiate surrounding normal tissue because of inconsistent field size by changing patient position during treatment. We are going to analyze errors reduced by using immobilization device with Electonic portal imaging device(EPID) in this study. We had treated the twenty-one patients in pelvic region with 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at supine position during treatment. They were separated to two groups, 11 patients without device and 10 patients with immobilization device. We used styrofoam for immobilization device and measured the errors of anterior direction for x, y axis and lateral direction for z, y axis from simulation film to EPID image using matching technique. For no immobilization device group, the mean deviation values of x axis and y axis are 0.19 mm. 0.48 mm, respectively and the standard deviations of systematic deviation are 2.38 mm, 2.19 mm, respectively and of random deviation for x axis and y axis are 1.92 mm. 1.29 mm, respectively. The mean deviation values of z axis and y axis are -3.61 mm. 2.07 mm, respectively and the standard deviations of systematic deviation are 3.20 mm, 2.29 mm, respectively and of random deviation for z axis and y axis are 2.73 mm. 1.62 mm, respectively. For immobilization device group, the mean deviation values of x axis and y axis are 0.71 mm. -1.07 mm, respectively and the standard deviations of systematic deviation are 1.80 mm, 2.26 mm, respectively and of random deviation for x axis and y axis are 1.56 mm. 1.27 mm, respectively. The mean deviation values of z axis and y axis are -1.76 mm. 1.08 mm, respectively and the standard deviations of systematic deviation are 1.87 mm, 2.83 mm, respectively and of random deviation for x axis and y axis are 1.68 mm, 1.65 mm, respectively. Because of reducing random and systematic error using immobilization device, we had obtained good reproducibility of patient setup during treatment so that we recommend the use of immobilization device in pelvic region of radiation treatment.

  • PDF

Simultaneous Effect between eWOM and Revenues: Korea Movie Industry (온라인 구전과 영화 매출 간 상호영향에 관한 연구: 한국 영화 산업을 중심으로)

  • Bae, Jungho;Shim, Bum Jun;Kim, Byung-Do
    • Asia Marketing Journal
    • /
    • v.12 no.2
    • /
    • pp.1-25
    • /
    • 2010
  • Motion pictures are so typical experience goods that consumers tend to look for more credible information. Hence, movie audiences consider movie viewers' reviews more important than the information provided by the film distributor. Recently many portal sites allow consumers to post their reviews and opinions so that other people check the number of consumer reviews and scores before going to the theater. There are a few previous researches studying the electronic word of mouth(eWOM) effect in the movie industry. They found that the volume of eWOM influenced the revenue of the movie significantly but the valence of eWOM did not affect it much (Liu 2006). The goal of our research is also to investigate the eWOM effects in general. But our research is different from the previous studies in several aspects. First, we study the eWOM effect in Korean movie industry. In other words, we would like to check whether we can generalize the results of the previous research across countries. The similar econometric models are applied to Korean movie data that include 746,282 consumer reviews on 439 movies. Our results show that both the valence(RATING) and the volume(LNMSG) of the eWOM influence weekly movie revenues. This result is different from the previous research findings that the volume only influences the revenue. We conjectured that the difference of self construal between Asian and American culture may explain this difference (Kitayama 1991). Asians including Koreans have more interdependent self construal than American, so that they are easily affected by other people's thought and suggestion. Hence, the valence of the eWOM affects Koreans' choice of the movie. Second, we find the critical defect of the previous eWOM models and, hence, attempt to correct it. The previous eWOM model assumes that the volume of eWOM (LNMSG) is an independent variable affecting the movie revenue (LNREV). However, the revenue can influence the volume of the eWOM. We think that treating the volume of eWOM as an independent variable a priori is too restrictive. In order to remedy this problem, we employed a simultaneous equation in which the movie revenue and the volume of the eWOM can affect each other. That is, our eWOM model assumes that the revenue (LNREV) and the volume of eWOM (LNMSG) have endogenous relationship where they influence each other. The results from this simultaneous equation model showed that the movie revenue and the eWOM volume interact each other. The movie revenue influences the eWOM volume for the entire 8 weeks. The reverse effect is more complex. Both the volume and the valence of eWOM affect the revenue in the first week, but only the volume affect the revenue for the rest of the weeks. In the first week, consumers may be curious about the movie and look for various kinds of information they can trust, so that they use the both the quantity and quality of consumer reviews. But from the second week, the quality of the eWOM only affects the movie revenue, implying that the review ratings are more important than the number of reviews. Third, our results show that the ratings by professional critics (CRATING) had negative effect to the weekly movie revenue (LNREV). Professional critics often give low ratings to the blockbuster movies that do not have much cinematic quality. Experienced audiences who watch the movie for fun do not trust the professionals' ratings and, hence, tend to go for the low-rated movies by them. In summary, applied to the Korean movie ratings data and employing a simultaneous model, our results are different from the previous eWOM studies: 1) Koreans (or Asians) care about the others' evaluation quality more than quantity, 2) The volume of eWOM is not the cause but the result of the revenue, 3) Professional reviews can give the negative effect to the movie revenue.

  • PDF

A Study on the Relationship between Camera and Subject for Visualization of Image - A Focus on the Status of Watch a Movie with Small Mobile Device - (영상의 시각화를 위한 카메라와 피사체의 상관관계 연구 - 스마트폰 사용자의 영상 시청 현황을 중심으로 -)

  • Ko, Hyun-Wook
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.5
    • /
    • pp.119-126
    • /
    • 2019
  • Watching movies is common on a big screen like a theater or on a big-screen TV. nowadays, small platform such as mobile devices is increasing rapidly for watch a movie. These changes are deeply related to the advent of Internet-based video streaming services such as OTT. OTT's development has provided in free video viewing system without using the set-top box is free from the limitations of time and space. Leading the market is Netflix[1], which started its business with Internet-based DVD rental service. Netflix, which is growing in tandem with the mobile market, had 193.26[2] million members as of the end of 2018. Other OTT participating companies include content-based Pooq, TVing, platform-based Olleh TV Mobile, Oksusu and LTE video portal. The size of such new growth projects has grown gradually, with 25.4 percent of all smartphone users currently watching video content with small mobile devices. Therefore, de-largeization, it is thought that visual language is needed for viewing small mobile devices that are capable of OTT services. To this end, this paper will identify the problem in viewing popular video content with small mobile devices and Survey and study its impact on viewers using the questionnaire.

Analyses of the Setup Errors using on Board Imager (OBI) (On Board Imager (OBI)를 이용한 Setup Error 분석에 대한 연구)

  • Kim, Jong-Deok;Lee, Haeng-O;You, Jae-Man;Ji, Dong-Hwa;Song, Ju-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • Purpose: The accuracy and advantages of OBI(On Board Imager) against the conventional method like film and EPID for the setup error correction were evaluated with the analysis of the accumulated data which were produced in the process of setup error correction using OBI. Materials and Methods: The results of setup error correction using OBI system were analyzed for the 130 patients who had been planned for 3 dimensional conformal radiation therapy during March 2006 and May 2006. Two kilo voltage images acquired in the orthogonal direction were fused and compared with reference setup images. The setup errors in the direction of vertical, lateral, longitudinal axis were recorded and calculated the distance from the isocenter. The corrected setup error were analyzed according to the lesion and the degree of shift variations. Results: There was no setup error in the 41.5% of total analyzed patients and setup errors between 1mm and 5mm were found in the 52.3%. 6.1% patients showed the more than 5mm shift and this error were verified as a difference of setup position and the movement of patient in a treatment room. Conclusion: The setup error analysis using OBI in this study verified that the conventional setup process in accordance with the laser and field light was not enough to get rid of the setup error. The KV images acquired using OBI provided good image quality for comparing with simulation images and much lower patients' exposure dose compared with conventional method of using EPID. These advantages of OBI system which were confirmed in this study proved the accuracy and priority of OBI system in the process of IGRT(Image Guided Radiation Therapy).

  • PDF