• Title/Summary/Keyword: Portal Distance

Search Result 35, Processing Time 0.03 seconds

A of Radiation Field with a Developed EPID

  • Y.H. Ji;Lee, D.H.;Lee, D.H.;Y.K. Oh;Kim, Y.J.;C.K. Cho;Kim, M.S.;H.J. Yoo;K.M. Yang
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.67-67
    • /
    • 2003
  • It is crucial to minimize setup errors of a cancer treatment machine using a high energy and to perform precise radiation therapy. Usually, port film has been used for verifying errors. The Korea Cancer Center Hospital (KCCH) has manufactured digital electronic portal imaging device (EPID) system to verify treatment machine errors as a Quality Assurance (Q.A) tool. This EPID was consisted of a metal/fluorescent screen, 45$^{\circ}$ mirror, a camera and an image grabber and could display the portal image with near real time KIRAMS has also made the acrylic phantom that has lead line of 1mm width for ligh/radiation field congruence verification and reference points phantom for using as an isocenter on portal image. We acquired portal images of 10$\times$10cm field size with this phantom by EPID and portal film rotating treatment head by 0.3$^{\circ}$, 0.6$^{\circ}$ and 0.9$^{\circ}$. To check field size, we acquired portal images with 18$\times$18cm, 19$\times$19cm and 20$\times$20cm field size with collimator angle 0$^{\circ}$ and 0.5$^{\circ}$ individually. We have performed Flatness comparison by displaying the line intensity from EPID and film images. The 0.6$^{\circ}$ shift of collimator angle was easily observed by edge detection of irradiated field size on EPID image. To the extent of one pixel (0.76mm) difference could be detected. We also have measured field size by finding optimal threshold value, finding isocenter, finding field edge and gauging distance between isocenter and edge. This EPID system could be used as a Q.A tool for checking field size, light/radiation congruence and flatness with a developed video based EPID.

  • PDF

Patellar Inferior Pole: New Landmark for the Anteromedial Instrument Portal for Arthroscopic Surgery of the Medial Meniscus Posterior Horn (슬개골 하극: 내측 반월상 연골판 후각부에 대한 관절경 수술을 위한 전내측 기구 삽입구의 새로운 표식)

  • Kim, Young-Mo;Hwang, Deuk-Soo;Lee, June-Kyu;Shin, Hyun-Dae;Kang, Tae-Hwan;Kim, Dong-Kyu;Kim, Pil-Sung
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.2
    • /
    • pp.128-134
    • /
    • 2008
  • Purpose: We prospectively evaluated the clinical usefulness of the patellar inferior pole (PIP) as a landmark of the anteromedial (AM) portal for the arthroscopic surgery of the medial mensiscus posterior horn (MMPH). Materials and Methods: Group 1 (50 normal left knees of adults), Group 2 (10 normal knees under anesthesia), and Group 3 (50 consecutive knees undergoing elective arthroscopic surgery for relatively simple intraarticular pathologies, or diagnostic arthroscopy) were included. In Group 1 and 2, the true lateral (A) and valgus stress lateral radiographs (B) on $30^{\circ}$ flexion were obtained, and the lines (AM portal line) passing through the PIP and distal-most medial femoral condyle (MFC) were drawn under the condition without considering the thickness of articular cartilage of MFC (1, 2-A, B group), and considering it as 2.5mm on B (1, 2-C group). Then, we investigated the meeting point of the AM portal line with medial tibial plateau (C-D percentage), and measured the distance between the PIP and the anterior joint line (E-length), and medial tibial-femoral joint space (F-length). In Group 3, the AM portal was made at the PIP level and clinical usefulness of the approach to the MMPH and body of the lateral meniscus (LM) was analyzed. Results: The average C-D percentage came out as 85.8, 101.3, 69.1% for each Group 1-A, B, C, and 102.4, 144.6, 116.8% for each Group 2-A, B, C. Measured E-length was an average of 15.1 (Group 1-A), 15.5 (Group 1-B, C), 13.1 (Group 2-A), and 12.9 mm (Group 2-B, C) and the change by valgus stress had no statistical significance. The F-length increased about 1.2 (Group 1) and 3.6 mm (Group 2) when valgus stress was applied, which had statistical significance (p<0.001, p<0.001). In Group 3, 49, 48 knees were classified as good for the MMPH, and the body of LM in aspect of the clinical usefulness of AM portal made on the PIP level. Conclusion: We identified the clinical usefulness of the PIP as a skin landmark of AM portal for the arthroscopic surgery of the MMPH.

  • PDF

Long Distance Vehicle License Plate Region Detection Using Low Resolution Feature of License Plate Region in Road View Images (로드뷰 영상에서 번호판 영역의 저해상도 특징을 이용한 원거리 자동차 번호판 영역 검출)

  • Oh, Myoung-Kwan;Park, Jong-Cheon
    • Journal of Digital Convergence
    • /
    • v.15 no.1
    • /
    • pp.239-245
    • /
    • 2017
  • For privacy protection, we propose a vehicle license plate region detection method in road view image served from portal site. Because vehicle license plate regions in road view images have different feature depending on distance, long distance vehicle license plate regions are not detected by feature of low resolution. Therefore, we suggest a method to detect short distance vehicle license plate regions by edge feature and long distance vehicle license plate regions using MSER feature. And then, we select candidate region of vehicle license plate region from detected region of each method, because the number of the vehicle license plate has a structural feature, we used it to detect the final vehicle license plate region. As the experiment result, we got a recall rate of 93%, precision rate of 75%, and F-Score rate of 80% in various road view images.

The Comparative Analysis of External Dose Reconstruction in EPID and Internal Dose Measurement Using Monte Carlo Simulation (몬테 카를로 전산모사를 통한 EPID의 외부적 선량 재구성과 내부 선량 계측과의 비교 및 분석)

  • Jung, Joo-Young;Yoon, Do-Kun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.253-258
    • /
    • 2013
  • The purpose of this study is to evaluate and analyze the relationship between the external radiation dose reconstruction which is transmitted from the patient who receives radiation treatment through electronic portal imaging device (EPID) and the internal dose derived from the Monte Carlo simulation. As a comparative analysis of the two cases, it is performed to provide a basic indicator for similar studies. The geometric information of the experiment and that of the radiation source were entered into Monte Carlo n-particle (MCNPX) which is the computer simulation tool and to derive the EPID images, a tally card in MCNPX was used for visualizing and the imaging of the dose information. We set to source to surface distance (SSD) 100 cm for internal measurement and EPID. And the water phantom was set to be 100 cm of the source to surface distance (SSD) for the internal measurement and EPID was set to 90 cm of SSD which is 10 cm below. The internal dose was collected from the water phantom by using mesh tally function in MCNPX, accumulated dose data was acquired by four-portal beam exposures. At the same time, after getting the dose which had been passed through water phantom, dose reconstruction was performed using back-projection method. In order to analyze about two cases, we compared the penetrated dose by calibration of itself with the absorbed one. We also evaluated the reconstructed dose using EPID and partially accumulated (overlapped) dose in water phantom by four-portal beam exposures. The sum dose data of two cases were calculated as each 3.4580 MeV/g (absorbed dose in water) and 3.4354 MeV/g (EPID reconstruction). The result of sum dose match from two cases shows good agreement with 0.6536% dose error.

Safety Assessment to Construction Position of Constructed Steel Structures under Declinating Earth Pressure (편토압을 받는 파형강판 구조물의 시공위치별 안전성 평가)

  • Lee, Sang-Hyun;Lim, Heui-Dae
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.1
    • /
    • pp.28-34
    • /
    • 2008
  • The corrugated steel plate structures is applied to the construction of mountain tunnel portal part with shallow depth, the tunnel on the outskirts of urban areas and ecology move passage. In this study, A finite element method is used for research the behavior of corrugated steel plate structures due to construction position under declinating earth pressure and excavation depth. A finite element method were performed varying construction position(10, 15, 20 and 25m) from slope and excavation depth from surface. The hoop thrust and moment, displacement of corrugated steel plate subjected to construction position and excavation depth is determined from a finite element method. From results of finite element method, it was found that the increase of thrust and the decrease of displacement as the amount of distance increase from slope with construction position. But the thrust and moment, displacement has not different value with excavation depth.

Development of Dose Verification Method for In vivo Dosimetry in External Radiotherapy (방사선치료에서 투과선량을 이용한 체내선량 검증프로그램 개발)

  • Hwang, Ui-Jung;Baek, Tae Seong;Yoon, Myonggeun
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.23-30
    • /
    • 2014
  • The purpose of this study is to evaluate the developed dose verification program for in vivo dosimetry based on transit dose in radiotherapy. Five intensity modulated radiotherapy (IMRT) plans of lung cancer patients were used in the irradiation of a homogeneous solid water phantom and anthropomorphic phantom. Transit dose distribution was measured using electronic portal imaging device (EPID) and used for the calculation of in vivo dose in patient. The average passing rate compared with treatment planning system based on a gamma index with a 3% dose and a 3 mm distance-to-dose agreement tolerance limit was 95% for the in vivo dose with the homogeneous phantom, but was reduced to 81.8% for the in vivo dose with the anthropomorphic phantom. This feasibility study suggested that transit dose-based in vivo dosimetry can provide information about the actual dose delivery to patients in the treatment room.

Verification of Mechanical Leaf Gap Error and VMAT Dose Distribution on Varian VitalBeamTM Linear Accelerator

  • Kim, Myeong Soo;Choi, Chang Heon;An, Hyun Joon;Son, Jae Man;Park, So-Yeon
    • Progress in Medical Physics
    • /
    • v.29 no.2
    • /
    • pp.66-72
    • /
    • 2018
  • The proper position of a multi-leaf collimator (MLC) is essential for the quality of intensity-modulated radiation therapy (IMRT) and volumetric modulated arc radiotherapy (VMAT) dose delivery. Task Group (TG) 142 provides a quality assurance (QA) procedure for MLC position. Our study investigated the QA validation of the mechanical leaf gap measurement and the maintenance procedure. Two $VitalBeam^{TM}$ systems were evaluated to validate the acceptance of an MLC position. The dosimetric leaf gaps (DLGs) were measured for 6 MV, 6 MVFFF, 10 MV, and 15 MV photon beams. A solid water phantom was irradiated using $10{\times}10cm^2$ field size at source-to-surface distance (SSD) of 90 cm and depth of 10 cm. The portal dose image prediction (PDIP) calculation was implemented on a treatment planning system (TPS) called $Eclipse^{TM}$. A total of 20 VMAT plans were used to confirm the accuracy of dose distribution measured by an electronic portal imaging device (EPID) and those predicted by VMAT plans. The measured leaf gaps were 0.30 mm and 0.35 mm for VitalBeam 1 and 2, respectively. The DLG values decreased by an average of 6.9% and 5.9% after mechanical MLC adjustment. Although the passing rates increased slightly, by 1.5% (relative) and 1.2% (absolute) in arc 1, the average passing rates were still within the good dose delivery level (>95%). Our study shows the existence of a mechanical leaf gap error caused by a degenerated MLC motor. This can be recovered by reinitialization of MLC position on the machine control panel. Consequently, the QA procedure should be performed regularly to protect the MLC system.

Analysis of the Contents of Visiting Nursing Articles on Domestic Portal Sites Using Topic Modeling: Focusing on the Comparison Before and After Coronavirus Disease (토픽 모델링을 이용한 국내 포털사이트 방문간호 기사 내용 분석: 코비드-19 이전과 이후 비교를 중심으로)

  • Lim, Ji Young;Lee, Mi Jin;Kim, Geun Myun;Lee, Ok kyun
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.30 no.2
    • /
    • pp.141-154
    • /
    • 2023
  • Purpose: This study aimed to explore the social perception of visiting nursing before and after coronavirus disease (COVID-19). Methods: This survey-based study used online big data for comparative analysis by classifying the keywords related to visiting nursing searched on domestic portal sites before and after COVID-19. Results: According to the results of analyzing the Intertopic Distance Map based on Latent Dirichlet Allocation in this study, four topics were extracted, two each before and after COVID-19. The first topic before the COVID-19 period was termed "the expansion of visiting nursing subjects and services visiting nursing," while the second was termed "visiting nursing," which is related to customized welfare. The first topic after the COVID-19 period was termed "the suspension and resumption of visiting nursing services," while the second was "the development of a non-face-to-face home visit healthcare system". Conclusion: The results of this study can be used as useful reference data to contribute to future medical service delivery system reform policies starting at the end of COVID-19 and the revitalization of community care for visiting nursing.

Comparison of dorsal and medial arthroscopic approach to canine coxofemoral joint: a cadaveric study

  • Sangjun Oh;Jinsu Kang;Namsoo Kim;Suyoung Heo
    • Journal of Veterinary Science
    • /
    • v.24 no.1
    • /
    • pp.12.1-12.10
    • /
    • 2023
  • Background: Arthroscopic exploration of ventromedial part of canine coxofemoral joint is limited in conventional dorsal approach. Objectives: We evaluated the efficacy of a medial arthroscopic approach to the coxofemoral joint of dogs by analyzing the joint visible area and performing a safety analysis. Methods: Arthroscopic approaches to the coxofemoral joint were made in five cadavers using a traditional (dorsal) and novel (medial) approach. Three observers scored the visible area of images and videos of the acetabulum and femur. A safety analysis was performed via dissection of the medial hind limb. The distance between neurovascular structures and arthroscopic portals was measured. Results: The acetabulum was more visible in the dorsal than in the medial approach, with mean visualization scores of 16 ± 0.00 and 11.83 ± 1.26, respectively. The medioventral side of the femur was significantly more visible in the medial than in the dorsal approach, with mean visualization scores of 3.9 ± 0.99 and 6.93 ± 0.58, respectively. Safety analysis confirmed the medial portal site was safe, provided that the surgeon has comprehensive knowledge of the joint. The minimum distance from the arthroscopic medial portals to the nearest neurovascular structures was 2.5 mm. Conclusions: A medial arthroscopic approach to the canine coxofemoral joint has potential clinical application. Dorsal and medial approaches differ significantly and have distinct purposes. The medial approach is useful to access the ventromedial joint, making it an eligible diagnostic method for an arthroscopic evaluation of this area.

Comparison of Deep Learning Algorithm in Bus Boarding Assistance System for the Visually Impaired using Deep Learning and Traffic Information Open API (딥러닝과 교통정보 Open API를 이용한 시각장애인 버스 탑승 보조 시스템에서 딥러닝 알고리즘 성능 비교)

  • Kim, Tae hong;Yeo, Gil Su;Jeong, Se Jun;Yu, Yun Seop
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.388-390
    • /
    • 2021
  • This paper introduces a system that can help visually impaired people to board a bus using an embedded board with keypad, dot matrix, lidar sensor, NFC reader, a public data portal Open API system, and deep learning algorithm (YOLOv5). The user inputs the desired bus number through the NFC reader and keypad, and then obtains the location and expected arrival time information of the bus through the Open API real-time data through the voice output entered into the system. In addition, by displaying the bus number as the dot matrix, it can help the bus driver to wait for the visually impaired, and at the same time, a deep learning algorithm (YOLOv5) recognizes the bus number that stops in real time and detects the distance to the bus with a distance detection sensor such as lidar sensor.

  • PDF