• 제목/요약/키워드: Portable signal

검색결과 261건 처리시간 0.036초

산업 현장에 적용할 수 있는 휴대형 정전기 측정기 설계 및 구현 (Design and Implementation of Portable Electrostatic Meter Applicable to Industrial Site)

  • 장문석;이응혁
    • 한국산업융합학회 논문집
    • /
    • 제23권6_2호
    • /
    • pp.971-977
    • /
    • 2020
  • In this paper, We propose a portable electrostatic meter which can measure high voltage static electricity caused by friction to prevent fire or explosion accidents in grinding, crushing, power injection, transport, filling, dust removal, painting, and foreign matter removal processes. The proposed device not only shows static electricity strength in 4 steps with respect to distance and voltage but also gives warning with a buzzer, on process facilities that are likely to generate high voltage static electricity due to friction. The device is implemented by filtering the signal detected by the wireless antenna, amplifying the signal by 6 times, and passing the signal through the integrator circuit. Tests are carried out with an electrostatic discharge simulator. And the results show that 4 LEDs are turned on at the distance of 10cm, 3 LEDs at 12cm, 2 LEDs at 13cm, and 1 LED at 15cm, when a fixed voltage of 500V is given. And also, the tests show that the static electricity can be detected at 5cm on 100V, 10cm on 200V, 15cm on 500V, 20cm on 1000V, and 25cm on 1500V. We expect to reduce accidents caused by static electricity by allowing safety managers on fields where fire or explosion accidents can happen to monitor static electricity.

Constructing Overhauser Dynamic Nuclear Polarization-Nuclear Magnetic Resonance System Using Benchtop Electron Paramagnetic Resonance Spectrometer

  • Saun, Seung-Bo;Kim, JiWon;Han, Oc Hee
    • 한국자기공명학회논문지
    • /
    • 제22권2호
    • /
    • pp.34-39
    • /
    • 2018
  • The Nuclear Magnetic Resonance (NMR) technique using Dynamic Nuclear Polarization (DNP) procedures is one of the promising techniques that enable overcoming low sensitivity problems in NMR spectroscopy. We constructed an ODNP-NMR system using a commercial benchtop EPR spectrometer. The $^1H$ NMR peak area of water in aqueous solutions of 4-hydroxy-TEMPO was enhanced more than 95 times in the ODNP-NMR experiments. Our signal enhancement results were about 55% of the previously reported result. This could be due to non-uniform microwave power over a sample and unwanted sample heating by microwave. However, this portable ODNP-NMR spectrometer will be eventually useful for site-specific detection with nano-scale spatial resolutions and molecular dynamics studies with significantly improved signal sensitivity.

심전도 자동진단장치를 위한 디지탈 신호처리시스템의 설계 (A Design of Digital Signal Processing System for the Automatic Diagnosis of Electrocardiogram)

  • 이종영;황선철;김용만;이명호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.1326-1328
    • /
    • 1987
  • This paper describes the design of digital signal processing system for the automatic diagnosis of ECG. The system comprises analog hardware, digital hardware, and control system by microcomputer. Also, since digital signal processing system can be equipped easily in microcomputer for the compact size(Single board), We expect to develop the Portable ECG Automatic Diagnosis System using this System.

  • PDF

블루투스에 사용한 생체신호의 무선 전송에 대한 연구 (A Study on wireless transmission of biomedical signal using Bluetooth)

  • 이동훈;장경섭;김기태
    • 한국컴퓨터산업교육학회:학술대회논문집
    • /
    • 한국컴퓨터산업교육학회 2003년도 제4회 종합학술대회 논문집
    • /
    • pp.99-102
    • /
    • 2003
  • Data acquisition of biomedical signal is important that can convert health of human body to measurable datas. In this paper, we developed system that can send multiple ECG data, ECG signal in biomedical signals, using Bluetooth wireless transmission. Developed system has several features, total gain of 1000, filtering data for noise reduction in hardware / software parts, portable to carry cause it has small size and battery operation. And system was designed which can measures data in several OS(Windows 2000, Windows CE).

  • PDF

적외선 호밍 유도탄의 조준축 정렬에 관한 연구 (A Study on the Alignment of Aiming Sight Unit for Infrared Homing Missile)

  • 정영숙
    • 한국군사과학기술학회지
    • /
    • 제7권3호
    • /
    • pp.30-37
    • /
    • 2004
  • For a proper operation of portable air defense IR terminal homing missile to the rapid intruding target, the boresight of an IR seeker of the missile should be accurately aligned with the gunner's aiming sight. Before a gunner fires the missile, he tries to keep the target within the circle of ASU ensuring the seeker to lock on the target correctly. In this paper, using an electrical seeker caging loop and IR detector signal characteristics, a precise aligning method between the seeker boresight and the LOS(Line of Sight) of ASU(Aiming Sight Unit) was studied. Although every seeker has slightly different SLA (Signal of Look Angle) output, we can get negligible alignment error through a fine tuning method of electrical caging signal. This alignment procedure was also adopted in K-PSAM system.

24시간 건강상태 모니터링을 위한 Bluethooth를 사용한 소형 저전력 휴대형 Bio-signal 측정 장치를 개발 (Development of Portable Bio-signal Measurement System using Bluetooth for 24-hours Continuous Health Monitoring)

  • 정현권;송길섭;나승유;이희영
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.81-84
    • /
    • 2001
  • This paper presents a potable bio-signal measurement system using Bluetooth for the 24-hours continuous health state monitoring of the elderly and the disabled. The measurement system has the functions of acquisition of various bio-signals, wireless data transmission and adjustment of parameters such as gain and cut-off frequency. This measurement system is designed according to the international specifications of the recommendation of AAMI (Association for the Advancement of Medical Instrumentation). The design targets of the developing system about volume and power consumption are 20x30x5mm$^3$ and 8mW.

  • PDF

컴팩트 플래쉬 방식의 휴대형 산소포화도 측정 및 ECG 감시 시스템의 구현 (Implementation of a ECG monitoring system and portable pulse oximeter for $SpO_2$ using Compact Flash Interface)

  • 김동학;김영길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.19-22
    • /
    • 2002
  • In this paper, we aims to develop a microcontroll er-based ECG monitoring system and portable pulse oximeter using Compact Flash Interface. First, portable pulse oximeter system is designed to record 2 channel of biosignals simultaneously, including 1 channel of $SpO_2$ and 1 channel of pulse rate. It is very small and portable. Besides, the system makes it possible to measure a patient's condition without an additional medical equipment. We tried to solve the problems generated by a patient's motion. That is, we added an analog circuit to a traditional pulse oximeter in order to eliminate the change of the base line. And we used 2D sector algorithm. As present, SpO2 modules are completed. But there are still many further development needed in order to enhance the function. Especially, compact falsh interface remains the most to complete. Second, ECG monitoring system uses almost same as present 3-lead ECG system. But we focus on the analog part, especially in filter. The proposed filter is composed of two parts. One is a filter to remove the power-line interface. The other is a filter to remove the baseline drift. A filter to remove the power-line and the baseline drift is necessarily used in the ECG system. The implemented filter have three features; minimizing the distortion in DC component, removing the harmonic component of power-line frequency. Using compact flash interface, we can easily transfer a patient's personal information and the measured signal data to a network based server environment. That means, it is possible to implement a patient's monitoring system with low cost.

  • PDF

USB OTG를 활용한 휴대용 가시광 수신기 구현 (Implementation of Portable Visible Light Receiver using USB OTG)

  • 이대희;이종성;오창헌
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 춘계학술대회
    • /
    • pp.741-743
    • /
    • 2017
  • 가시광 통신은 송신부의 LED가 빛을 전송하면 수신부의 수광 다이오드에서 조도 임계값을 기준으로 이진 데이터를 출력하는 통신방식이다. 하지만 광 신호를 수신하기 위해서는 별도의 수신기가 필수적이며, 이러한 수신기가 탑재되지 않은 디바이스는 가시광 통신을 활용할 수 없는 문제점이 있다. 이를 해결하기 위해 본 논문에서는 USB OTG를 활용하여 디바이스에 적용 가능한 휴대용 가시광 수신기를 제안한다. 구현한 휴대용 가시광 수신기는 LED로부터 수신한 이진 데이터를 ASCII 코드의 문자열로 변환하여 다른 디바이스로 전송한다. 스마트폰을 이용한 데이터 전송 실험을 통해 제안한 방식에서 ASCII 코드의 문자열 전송이 가능함을 보였다.

  • PDF

소형 표면 플라즈몬 공명 센서와 이합체 구조를 가진 SAM을 이용한 CRP 검출 (A portable surface plasmon resonance sensor system for detection of C-reactive protein using SAM with dimer structure)

  • 신은정;정은정;조진희;황동환;손영수
    • 센서학회지
    • /
    • 제19권6호
    • /
    • pp.456-461
    • /
    • 2010
  • The detection of C-reactive protein(CRP) using self-assembled monolayer(SAM) was investigated by a portable surface plasmon resonance(SPR) sensor system. The CRP is a biomarker for the possible cardiovascular disease. The SAM was formed on gold(Au) surface to anchor the monoclonal antibody of CRP(anti-CRP) for detection of CRP. Sequence injection of the anti-CRP and bovine serum albumin(BSA) into the sensor system has been carried out immobilize the antibody and to prevent non-specific binding. The portable SPR system has two flow channels: one for the sample measurements and the other for the reference. The output SPR signal was increased with the injection of the anti-CRP, BSA and CRP due to binding of the proteins on the sensor chip. The valid output SPR signals was linearly related to the critical range of the CRP concentration. The experimental results showed the feasibility of the portable SPR system with newly developed SAM to diagnose a risk of the future cardiovascular events.

Lightweight Single Image Super-Resolution Convolution Neural Network in Portable Device

  • Wang, Jin;Wu, Yiming;He, Shiming;Sharma, Pradip Kumar;Yu, Xiaofeng;Alfarraj, Osama;Tolba, Amr
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권11호
    • /
    • pp.4065-4083
    • /
    • 2021
  • Super-resolution can improve the clarity of low-resolution (LR) images, which can increase the accuracy of high-level compute vision tasks. Portable devices have low computing power and storage performance. Large-scale neural network super-resolution methods are not suitable for portable devices. In order to save the computational cost and the number of parameters, Lightweight image processing method can improve the processing speed of portable devices. Therefore, we propose the Enhanced Information Multiple Distillation Network (EIMDN) to adapt lower delay and cost. The EIMDN takes feedback mechanism as the framework and obtains low level features through high level features. Further, we replace the feature extraction convolution operation in Information Multiple Distillation Block (IMDB), with Ghost module, and propose the Enhanced Information Multiple Distillation Block (EIMDB) to reduce the amount of calculation and the number of parameters. Finally, coordinate attention (CA) is used at the end of IMDB and EIMDB to enhance the important information extraction from Spaces and channels. Experimental results show that our proposed can achieve convergence faster with fewer parameters and computation, compared with other lightweight super-resolution methods. Under the condition of higher peak signal-to-noise ratio (PSNR) and higher structural similarity (SSIM), the performance of network reconstruction image texture and target contour is significantly improved.