• 제목/요약/키워드: Portable instruments

검색결과 57건 처리시간 0.022초

Comparison of the bovine blood gas parameters produced with three types of portable blood gas analyzers

  • Ro, Younghye;Choi, Woojae;Hong, Leegon;Kim, Eunkyung;Choe, Eunhui;Kim, Danil
    • Journal of Veterinary Science
    • /
    • 제23권4호
    • /
    • pp.60.1-60.6
    • /
    • 2022
  • Background: A definite diagnosis should be made in the bovine practice field, however, it was difficult to perform laboratory analysis immediately. Currently, three types of portable blood gas analyzers are available in Korea. Objectives: This study aimed to evaluate the correlations among these three analyzers. Methods: Seventy-two plasma samples from Holstein-Friesian cows were used for blood gas analysis, and three instruments (EDAN i15 Vet, VETSCAN i-STAT, and EPOC) were operated simultaneously. Moreover, plasma calcium levels were compared between these portable analyzers and blood chemistry device, which is usually used in a laboratory environment. Pearson analysis was performed to confirm the correlation of each parameter produced with the three instruments and blood chemistry analyzer. Results: As results, high correlation was observed in parameters of pH, pO2, potassium ion, ionized calcium, and glucose (p < 0.001, r > 0.7). In addition, pCO2 showed a moderate correlation among the three analyzers (p < 0.001, r > 0.5), and there was no correlation among all instruments for sodium ions. There was also a high correlation between ionized calcium from the three portable devices and total calcium from the biochemistry analyzer (p < 0.001, r > 0.9). Conclusions: In conclusion, there was a high correlation between results from the three different blood gas analyzers used in the bovine clinical field in Korea. Thus, a consistent diagnosis can be made even with different equipment if the operator is aware of the strengths and weaknesses of each piece of equipment and operates it properly.

필드 스크린을 위한 휴대용 전자코 시스템의 구현 (Implementation of a Portable Electronic Nose System for Field Screening)

  • 변형기;이준섭;김정도
    • 센서학회지
    • /
    • 제13권1호
    • /
    • pp.41-46
    • /
    • 2004
  • There is currently much interest in the development of instruments that emulate the senses of humans. Increasingly, there is demand for mimicking the human sense of smell, which is a sophisticated chemosensory system. An electronic nose system is applicable to a large area of industries including environmental monitoring. We have designed a protable electronic nose system using an array of commercial chemical gas sensors for recognizing and analyzing the various odours. In this paper, we have implemented a portable electronic nose system using an array of gas sensors for recognizing and analyzing VOCs (Volatile Organic Compounds) in the field. The accuracy of a portable electronic nose system may be lower than an instrument such as GC/MS (Gas Chromatography/Mass Spectrometer). However, a portable electronic nose system could be used on the field and showed fast response to pollutants in the field. Several different algorithms for odours recognition were used such as BP (Back-Propagation) or LM-BP (Levenberq-Marquardt Back-Propagation). We applied RBF (Radial Basis Function) Network for recognition and quantifying of odours, which has simpler and faster compared to the previously used algorithms such as BP and LM-BP.

소셜 연주를 지원하는 스마트폰기반 다중 악기 애플리케이션 구현 (An Implementation of Smartphone-based Multiple Musical Instruments Application supporting Social Playing)

  • 황병곤
    • 디지털콘텐츠학회 논문지
    • /
    • 제12권4호
    • /
    • pp.575-583
    • /
    • 2011
  • 최근 전 세계적으로 모바일 디바이스 및 통신 기술의 발전으로 전화와 문자 메시지만 주로 사용하던 기본 휴대폰은 스마트폰으로 급격하게 진화하여 사회의 각 영역에 다양한 서비스를 제공하고 있다. 본 논문은 스마트폰을 이용하여 밴드 연주에 들어가는 기본 악기인 기타, 피아노, 베이스 그리고 드럼을 기반으로 한 멀티유저 악기 연주 애플리케이션을 제안한다. 이 애플리케이션은 스마트폰에서 개별적으로 연주한 음악은 서버의 시간 동기화 기능에 의해서 통합된 음악 데이터 스트림으로 생성된다. 더불어 실제 악기와 유사한 그래픽 유저 인터페이스 실현으로 사용자는 효율적으로 스마트폰에 의한 악기 연주를 할 수 있다.

델파이 기법을 이용한 응급의료에서의 휴대용 디지털 X-ray 발생장치의 적절성 (The Propriety of Portable Digital X-RAY Equipment for Emergency Medical Services)

  • 조동헌;구경완;양해술;조진만;한만석;이미옥
    • 한국응급구조학회지
    • /
    • 제9권1호
    • /
    • pp.15-23
    • /
    • 2005
  • The purpose of this study is to analyze the propriety of portable digital X-ray Equipment for Emergency Medical Services in Daejon Emergency Medical Center in Korea. The major instruments of this study were Korean Self-Analysis Opinionnaire, Questionnaire contains 35 items which measure emergency medical personal opnions. To take the analysis of data, the total of 92 persons were investigated in Medical Information Center in Daejon Metropolitan City from 2005. 20. April to 2004. 25. May. The data were analyzed by the path analysis SPSS program. First, portable X-RAY equipment is needed to apply it to emergency. Second, it should have small and light structure compared with old equipments and have high voltage generator unit for X-RAY using inverter. Third, it should be able to send the shot data that is digital detector type without film to doctors in emergency center.

  • PDF

Reliability of Portable Spirometry Performed in the Korea National Health and Nutrition Examination Survey Compared to Conventional Spirometry

  • Park, Hye Jung;Rhee, Chin Kook;Yoo, Kwang Ha;Park, Yong Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • 제84권4호
    • /
    • pp.274-281
    • /
    • 2021
  • Background: The Korea National Health and Nutrition Examination Survey (KNHANES) is a well-designed survey to collect national data, which many researchers have used for their studies. In KNHANES, although portable spirometry was used, its reliability has not been verified. Methods: We prospectively enrolled 58 participants from four Korean institutions. The participants were classified into normal pattern, obstructive pattern, and restrictive pattern groups according to their previous spirometry results. Lung function was estimated by conventional spirometry and portable spirometry, and the results were compared. Results: The intraclass correlation coefficients of forced vital capacity (FVC) (coefficient, 9.993; 95% confidence interval [CI], 0.988-0.996), forced expiratory volume in 1 second (FEV1) (coefficient, 0.997; 95% CI, 0.995-0.998), FEV1/FVC ratio (coefficient, 0.995; 95% CI, 0.992-0.997), and forced expiratory flow at 25-75% (FEF25-75%; coefficient, 0.991; 95% CI, 0.984-0.994) were excellent (all p<0.001). In the subgroup analysis, the results of the three parameters were similar in all groups. In the overall and subgroup analyses, Pearson's correlation of all the parameters was also excellent in the total (coefficient, 0.986-0.994; p<0.001) and subgroup analyses (coefficient, 0.915-0.995; p<0.001). In the paired t-test, FVC, FEV1/FVC, and FEF25-75% estimated by the two instruments were statistically different. However, FEV1 was not significantly different. Conclusion: Lung function estimated by portable spirometry was well-correlated with that estimated by conventional spirometry. Although the values had minimal differences between them, we suggest that the spirometry results from the KNHANES are reliable.

소방시설의 화재진압 활용실태에 관한 연구 (A Study on the State of Utilizing Fire Facility in Fire Fighting)

  • 이창섭
    • 한국화재소방학회논문지
    • /
    • 제25권2호
    • /
    • pp.144-148
    • /
    • 2011
  • 본 연구에서는 소방공무원들이 건축물에 설치된 소방시설을 화재진압에 적절하게 활용하고 있는지, 그리고 사용하고 있지 않다면 이를 이용하는데 어떤 문제점이 있는지에 대하여 파악하고, 문제가 있다면 개선방안은 어떠한 것이 있는지에 대하여, 소방공무원들을 대상으로 설문과 인터뷰를 실시하고 결과를 분석하였다. 소방공무원들은 평소 사용하는데 익숙한 휴대 장비를 사용하려는 경향이 있었으며, 62%가 소방시설을 사용하여 화재를 진압한 경험이 있고, 활용한 소방시설은 옥내소화전이 42%로 가장 많았으며, 소방시설이 설치되어 있는데도 활용하지 않은 이유로는 신속대응을 위해 적절하지 않기 때문이라는 답변이 32.5%로 가장 많았고, 건축물에 설치된 소방시설을 용이하게 사용하기 위한 개선이 필요한가에 대한 질문에 대부분 매우 그렇다 및 그렇다고 답변하였다. 결론적으로 화재현장에서 건축물에 설치된 소방시설 활용도의 변수로서 현장지휘자의 소방시설 활용에 대한 적극성, 소방시설활용 능력, 설치기준 및 구조의 용이성, 소방시설의 신뢰도에 대한 인식 등이 유의한 것으로 조사되었다.

RFID 기술을 이용한 휴대형 상품정보제공 시스템 개발 (Development of portable Merchandise Information Providing System Using RFID)

  • 류정탁;최창환;문병현
    • 한국산업정보학회논문지
    • /
    • 제11권2호
    • /
    • pp.98-102
    • /
    • 2006
  • 최근 정보기술의 발전으로 유비쿼터스 컴퓨팅 환경이 대두되고 있으며 이에 따라 RFID라는 신기술의 등장과 응용에 관한 연구가 활발히 진행되고 있다. 이에 본 논문에서는 기존 RFID 시스템에서 유선망을 사용한 데이터 전송으로 인하여 발생될 수 있는 공간 및 이동성의 제약을 극복하기위하여 저가의 무선전송모듈을 적용하여 휴대형 상품정보제공 시스템을 개발하였다. 무선전송 모듈은 900MHz 대역의 Texas Instruments 사의 TRF6901 chipset을 이용하였고 이를 제어하는 MPU는 TI사의 MSP430F149로 설계하였다. 본 논문에서 개발한 시스템은 도서관리, 출입통제시스템등에 범용적으로 적용될 수 있을 뿐 아니라 이동형 RFID시스템에 혁신적인 기대 효과를 예상할 수 있다.

  • PDF

스마트기기용 강압형 DC-DC 변환기 특성해석 (Analysis of a Buck DC-DC Converter for Smart Electronic Applications)

  • 강보경;나재훈;송한정
    • 한국산업융합학회 논문집
    • /
    • 제22권3호
    • /
    • pp.373-379
    • /
    • 2019
  • Nowadays, the IoT portable electronic devices have become more useful and diverse, so they require various supply voltage levels to operate. This paper presents a DC-DC buck converter with pulse width modulation (PWM) for portable electronic devices. The proposed step-down DC-DC converter consists of passive elements such as capacitors, inductors, and resistors and an integrated chip (IC) for signal control to reduce power consumption and improves ripple voltage with the resolution. The proposed DC-DC converter is simulated and analyzed in PSPICE circuit design platform, and implemented on the prototype PCB board with a Texas Instruments LM5165 IC. The proposed buck converter is showed 92.6% of peak efficiency including a load current range of 4-10 mA, 3.29 mV of the voltage ripple at 5 V output voltage for the supply voltage 12 V. Measured and Simulated power efficiency are made good agreement with each other.

블랙카본 측정기용 초소형 사이클론 집진기 개발 (Development of a Miniature Aerosol Separator for a Black Carbon Measuring Instrument)

  • 안익현;임준형;이효영;육세진
    • 한국기계가공학회지
    • /
    • 제19권12호
    • /
    • pp.42-48
    • /
    • 2020
  • Given the increasing interest in air pollution, several technologies to measure black carbon (BC) aerosol particles have been developed. As most BC aerosol particles are smaller than 1 ㎛, it is necessary to pre-separate the particles by size before a BC measuring instrument samples the aerosol particles. In this study, a miniature cyclone separator for portable BC measuring instruments was developed. A numerical approach was used to design the miniature cyclone separator with operating flow rates of 50, 100, or 150 mLPM, and then a prototype cyclone separator was manufactured for experimental validation. The numerical results of the cut-off size and pressure drop of the miniature cyclone separator agreed well with the experimental data. The cut-off sizes of the miniature cyclone separator were determined to be 2.9, 0.94, and 0.63 ㎛ for operating flow rates of 50, 100, and 150 mLPM, respectively. Thus, the miniature cyclone separator is suitable for use as a sampling inlet for the portable black carbon measuring instrument to sample BC aerosol or PM2.5 aerosol.

휴대용 분광분석기를 이용한 알코올 중에 함유되어 있는 물의 측정 (Determination of water content in alcohol by portable near infrared (NIR) system)

  • 안지원;우영아;김효진
    • 분석과학
    • /
    • 제16권2호
    • /
    • pp.95-101
    • /
    • 2003
  • 본 연구에서는 근적외선 분광분석법 (NIR)을 이용하여 메탄올과 에탄올 혼합액 중의 물의 함량을 비파괴적으로 측정하였다. Photo-diode array 방식의 휴대용 NIR system과 scanning 방식의 NIR spectrometer를 이용하여 두 기기 사이의 calibration 결과를 비교하였다. 알코올 혼합액 중의 물의 함량을 정량분석 하기 위해 부분최소자승회귀분석법 (PLSR : partial least squares regression)을 사용하였다. 그 결과 SEP (standard error of prediction)가 photo-diode array 방식을 사용하였을 때는 0.10%, scanning 방식을 사용하였을 때는 0.12%였다. Calibration 모델의 안정성을 확인하기 위하여 6일 동안 2%의 메탄올을 함유하고 있는 에탄올 용액 중의 물의 함량이 3%, 5% 및 7% 되도록 시료를 조제하여 측정하였다. 두 가지 방식의 NIR 모두 3%이내의 변동계수 (CV : coefficient of variation)로 좋은 결과를 나타내었다. 이번 연구를 통해서 메탄올과 에탄올 혼합액 중의 물의 함량 측정이 근적외선 분광분석법을 이용하여 성공적으로 수행되었고 photo-diode array 방식의 휴대용 NIR 시스템을 이용해서 scanning 방식의 NIR spectrometer를 이용한 결과와 유사한 결과를 얻을 수 있었다.