• Title/Summary/Keyword: Portable detector

Search Result 113, Processing Time 0.022 seconds

Development of the Unmanned Automatic Test System for a Portable Detector using TRIZ TESE

  • Chang, YuShin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.6
    • /
    • pp.63-71
    • /
    • 2021
  • This paper propose an development of the unmanned automatic test system for a portable detector using TRIZ Methodology. A new development scheme among of the unmanned automatic test system configurations was obtained after application of the TESE(Trends of Engineering System Evolution) one of the TRIZ methods. Using Pugh matrix drives some improving ideas. The key idea of this unmanned automatic test system scheme is to minimize whole test procedure time of each portable detector and to maximize the amount of portable detectors at once. Between the before and the after configurations of the 3D mechanical model find out improvements. This paper shows that the proposed development scheme improves the test performance efficiency compared to previous scheme.

Determination of Spectrum-Exposure Rate Conversion Factor for a Portable High Purity Germanium Detector (휴대형 고순도 게르마늄검출기에 대한 스펙트럼-조사선량율 변환연산자의 결정)

  • Kwak, Sang-Soo;Park, Chong-Mook;Ro, Seung-Gy
    • Journal of Radiation Protection and Research
    • /
    • v.13 no.2
    • /
    • pp.29-40
    • /
    • 1988
  • A spectrum-exposure rate conversion operator G(E) for a portable HPGe detector used for field environmental radiation survey was theoretically developed on the basis of a space distribution function of gamma flux emitted from a disk source and an areal efficiency of the detector. The radiation exposure rates measured using this G(E) and the portable HPGe. detector connected to a portable multichannel analyzer were compared with those measured by a 3' ${\phi}\;{\times}$3' NaI(Tl) scintillation detector with the reported G(E) and a pressurized ionization chamber. A comparison of the three results showed that the result obtained using the HPGe detector was lower than those determined using the NaI(Tl) detector and ionization chamber by 17% to 29%, The difference obtained is close to that reported in literature. The method developed here can be easily applicable to obtain a G(E) factor suitable to any detector for detecting the exposure rate of environmental gamma radiation, since the spectrum-exposure rate conversion operator can be calculated by a hand calculator.

  • PDF

Implementation of Digital Portable Radiation Detector with the Algorithm of Temperature Compensation (온도 보정 Algorithm을 적용한 Digital 휴대용 방사선 검출기의 구현)

  • Park, Ge-O;Lee, Jung-Hyun;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.202-205
    • /
    • 2016
  • Shipping and logistics safety, security system is strengthening worldwide, the development of shipping and logistics safety security core technology for national security logistics system construction has been carried out. Interest in portable radiation detection device capable detecting gamma rays nuclides is increasing. In this paper, I would like to propose the study of implementation of digital portable radiation detector with the algorithm of temperature compensation.

  • PDF

A Portable Electromagnetic Wave Detector (휴대 전자파 탐지기)

  • Kang, Seong-Jun;Park, Chong-Yeon;Hwang, Hee-Yong
    • Journal of Industrial Technology
    • /
    • v.27 no.A
    • /
    • pp.177-184
    • /
    • 2007
  • This paper presents a miniaturized electromagnetic wave detector. The dimension is reduced down to $31{\times}18{\times}13.5mm^3$ by using common OP-AMPs for amplification and oscillation. The strength from wave radiators is indicated by a color LED; green, orange and red colors mean the low, the middle and the high level, respectively. An alarm bell rings as the wave strength becomes above high level. The detector uses 3V battery. The detector could be used for a cellular phone decoration, a necklace pendant and a key holder.

  • PDF

Joint OSIC and Soft ML Decoding Scheme for Coded Layered Space-Time OFDM Systems

  • Lee, Hye-Jeong;Chung, Jae-Ho;Park, Se-Jun;Lee, Seong-Choon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.5A
    • /
    • pp.487-493
    • /
    • 2008
  • In this paper, we consider coded layered space-time architecture in MIMO-OFDM channels. Vertical Bell Lab Layered Space-Time(V-BLAST) scheme employing ordered successive interference cancellation(OSIC) algorithm provides very high spectral efficiency with low computational complexity. However, the error propagation is a major drawback constraining the overall performance of the V-BLAST system significantly. Based on this problem, we derive an improved detector using soft bit log-likelihood ratio(LLR) value. Simulation results show that the proposed detector outperforms the conventional V-BLAST scheme under spatially uncorrelated as well as correlated fading channels.

Research for realization of platform of portable radiation detector using NaI(TI) Scintillator (NaI(TI) Scintillator를 이용한 휴대용 방사선 검출 장치 구현에 대한 연구)

  • Lee, Yoon-Ho;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.266-269
    • /
    • 2012
  • Over the world, the development of critical technology for the safety and security of coastal distribution based on ubiquitous computing is being processed to meet the bottom lines of governmental regulations. Currently, 3D detectors using X-rays for freight search technology are being developed concerning U-based shipping security systems. In addition to that, there are increasing needs for developing portable radiation detector to detect gamma rays nuclide. The purpose of the thesis is to suggest the research of high speed portable gamma rays detector platform to prevent disorder caused to humans and public objects.

  • PDF

Research for realization of platform of portable radiation detector using NaI(Tl) Scintillator (NaI(Tl) Scintillator를 이용한 휴대용 방사선 검출 장치 구현에 대한 연구)

  • Lee, Jon-Hwey;Joh, Yool-Hee;Lee, Yoon-Ho;Lim, Ik-Chan;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.10
    • /
    • pp.2323-2328
    • /
    • 2012
  • Over the world, the development of critical technology for the safety and security of coastal distribution based on ubiquitous computing is being processed to meet the bottom lines of governmental regulations. Currently, 3D detectors using X-rays for freight search technology are being developed concerning U-based shipping security systems. In addition to that, there are increasing needs for developing portable radiation detector to detect gamma rays. The purpose of the thesis is to suggest the research of high speed portable gamma rays detector platform to prevent disorder caused to humans and public objects.

Assessment of Applicability of Portable HPGe Detector with In Situ Object Counting System based on Performance Evaluation of Thyroid Radiobioassays

  • Park, MinSeok;Kwon, Tae-Eun;Pak, Min Jung;Park, Se-Young;Ha, Wi-Ho;Jin, Young-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.2
    • /
    • pp.83-90
    • /
    • 2017
  • Background: Different cases exist in the measurement of thyroid radiobioassays owing to the individual characteristics of the subjects, especially the potential variation in the counting efficiency. An In situ Object Counting System (ISOCS) was developed to perform an efficiency calibration based on the Monte Carlo calculation, as an alternative to conventional calibration methods. The purpose of this study is to evaluate the applicability of ISOCS to thyroid radiobioassays by comparison with a conventional thyroid monitoring system. Materials and Methods: The efficiency calibration of a portable high-purity germanium (HPGe) detector was performed using ISOCS software. In contrast, the conventional efficiency calibration, which needed a radioactive material, was applied to a scintillator-based thyroid monitor. Four radioiodine samples that contained $^{125}I$ and $^{131}I$ in both aqueous solution and gel forms were measured to evaluate radioactivity in the thyroid. ANSI/HPS N13.30 performance criteria, which included the relative bias, relative precision, and root-mean-squared error, were applied to evaluate the performance of the measurement system. Results and Discussion: The portable HPGe detector could measure both radioiodines with ISOCS but the thyroid monitor could not measure $^{125}I$ because of the limited energy resolution of the NaI(Tl) scintillator. The $^{131}I$ results from both detectors agreed to within 5% with the certified results. Moreover, the $^{125}I$ results from the portable HPGe detector agreed to within 10% with the certified results. All measurement results complied with the ANSI/HPS N13.30 performance criteria. Conclusion: The results of the intercomparison program indicated the feasibility of applying ISOCS software to direct thyroid radiobioassays. The portable HPGe detector with ISOCS software can provide the convenience of efficiency calibration and higher energy resolution for identifying photopeaks, compared with a conventional thyroid monitor with a NaI(Tl) scintillator. The application of ISOCS software in a radiation emergency can improve the response in terms of internal contamination monitoring.

Implementation of A9-Based Digital Portable Radiation Detector with the Algorithm of Temperature Compensation in Scintillator (Scintillator에 온도 보정 알고리즘을 적용한 A9기반의 디지털 휴대용 방사선 검출기 구현)

  • Lim, Ik-Chan;Park, Geo;Kim, Young-kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.10
    • /
    • pp.1981-1989
    • /
    • 2017
  • In accordance with the global strengthening of security systems for the safety of the shipping and logistics industry, the development of core technologies within the field has become a key in the establishment of Korea's own national logistics security system. Further in line with these global developments, there is growing attention within Korea to the development of portable radiation detectors capable of detecting gamma ray nuclides. In addition, many parts are becoming localized. In this research, instead of Pulse Shaping Board, which is used in existing portable radiation detectors, we have implemented an Algorithm to discriminate nuclides and correct the temperature conversion efficiency of the scintillator. This paper aims to improve the performance of these devices through the implementation of a temperature conversional algorithm within the scintillator of the A9-based digital portable radiation detector.

Development of the Portable Standard System for the Vehicle Detectors' Evaluation (차량검지기 성능평가를 위한 이동식 기준 장비 개발)

  • Lee, Sang Hyup;Baik, Nam Cheol;Heo, Woon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3D
    • /
    • pp.353-359
    • /
    • 2006
  • Image frame analysis is a conventional way of evaluating loop detector's performance. In image frame analysis, the time to evaluate performance is linearly proportional to the number of evaluated subjects, and the results can be subjective, depending on operator's personal evaluation standards and physical condition. Also, this method is often inferior in accuracy to that provided by the evaluated devices. Therefore, it is critical to develop a portable standard system which has better accuracy and more objectivity in evaluating vehicle detectors. This paper discusses function and reliability of tape-switch detector, which can be a replacement for image frame analysis, for effectively measuring traffic volume, speed, and occupancy.