• Title/Summary/Keyword: Portable Program

Search Result 145, Processing Time 0.022 seconds

Development of a Tele-Rehabilitation System for Outcome Evaluation of Physical Therapy

  • Park, Hyung-Soon;Lee, Jeong-Wan
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.3
    • /
    • pp.179-186
    • /
    • 2008
  • This paper presents a portable tele-assessment system designed for remote evaluation of the hypertonic elbow joint of neurologically impaired patients. A patient's upper limb was securely strapped to a portable limb-stretching device which is connected through Internet to a portable haptic device by which a clinician remotely moved the patient's elbow joint and felt the resistance from the patient. Elbow flexion angle and joint torques were measured from both master and slave devices and bilaterally fed back to their counterparts. In order to overcome problems associated with the network latency, two different tele-operation schemes were proposed depending on relative speed of tasks compared to the amount of time delay. For slow movement tasks, the bilateral tele-operation was achieved in real-time by designing control architectures after causality analysis. For fast movement tasks, we used a semi-real-time tele-operation scheme which provided the clinicians with stable and transparent feeling. The tele-assessment system was verified experimentally on patients with stroke. The devices were made portable and low cost, which makes it potentially more accessible to patients in remote areas.

BIOFIT - Smart, Portable, Wearable and Wireless Digital Exercise Trainer Device with Biofeedback Capability

  • Diwakar Praveen Kumar;Oh Young-Keun;Chung Gyo-Bum;Park Seung-Hun
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.36-45
    • /
    • 2007
  • Today Human Personal Trainers are becoming very famous in this health conscious world. They teach user to achieve fitness goals in managed way. Due to their high fee and tight schedule they are unavailable to mass number of people. Another solution to this problem is to develop digital personal trainer portable instrument that may replace human personal trainers. We developed a portable digital exercise trainer device - BIOFIT that manages, monitors and records the user's physical status and workout during exercise session. It guides the user to exercise efficiently for specific fitness goal. It keeps the full exercise program i.e. exercises start date and time, duration, mode, control parameter, intensity in its memory which helps the user in managing his exercise. Exercise program can be downloaded from the internet. During exercise it continuously monitors the user's physiological parameters: heart rate, number of steps walked, and energy consumed. If these parameters do not range within prescribed target zone, the BIOFIT will alarm the user as a feedback to control exercise. The BIOFIT displays these parameters on graphic LCD. During exercise it continuously records the heart rate and number of steps walked every 10 seconds along with exercise date and time. This stored information can be used as treatment for the user by an exercise expert. Real-time ECG monitoring can be viewed wirelessly (RF Communication) on a remote PC.

Research on Development of a Wide Range Velocity Control Method of Small Size DC Motor for Portable Drug Delivery System

  • Lee, Dong-Joon;Lim, Yang-Ho;Kim, Jang-Hwan;Shin, Chan-Soo;Kim, Hee-Chan;Choi, Soo-Bong;Lee, Hong-Gyu
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.22-24
    • /
    • 1996
  • Small size DC motor control method for portable drug delivery system has been developed to be used for the actuator of insulins pump. The control method gives the controllabilities both in high speed(40-50 revolution per second(rps)) DC motor drive and also in low speed(0.5-1rps). In low speed mode DC motor is controlled to act like stepping motor and in high speed to optimize power consumption. To control both mode modified bang bang control is suggested. Using this method small size DC motor(spec.) speed is controlled from 0.2 rps to 50 rps. Experimental setup is developed using micro-processor(PIC16C73, Micro Chips co., USA), motor turns checking circuitry, small size DC motor for pager(SM1012, Samhong co., Korea) and gear box. Results from experiment meet need for vailable load condition which is require for portable drug delivery system.

  • PDF

Development of Electric Instrument of Current and Leakage Current based on NI-9223 and Current Prove (NI-9223과 전류프로브를 이용한 전류 및 누설전류 측정장치 개발)

  • Kim, Sung-Chul;Kim, Un-Sul
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.48-53
    • /
    • 2012
  • This paper is purposed to develop portable electric instrument to select NI-9223(National instrument comp.) and clamp meter(HIOKI comp.), which can be used in developing electric instrument, to detect leakage current(ZCT) and current(CT) signals. In this paper, The electric instrument that can interface with current and leakage current instrument(HIOKI 9283), is developed by NI-9223 of NI comp.. HIOKI clamp meter can measure current signals certainly by high-sensitivity of 10 ${\mu}A$ resolution(leakage current : at 10 mA range) and current 1~200A range. The NI-9223 use four 16-bit analog-to-digital converters(ADCs) for true simultaneous sampling at up to 1 MS/s per channel. NI-9223 can synchronize all analog input modules installed in the same chassis to share the same start clock and/or sample clocks. The monitoring program is developed by SignalExpress of LabVIEW. The monitoring program are developed to analyze at simultaneous sampling on electrical signals such as leakage current(ZCT) and current(CT). The developed system verification tests were conducted, and portable electric instrument can be used in place which requires analysis of the actual electrical signal.

Implementation of Play and Copy Control of DMB contents using Watermarking and Encryption on PMP (워터마킹과 암호화를 이용한 DMB 콘텐츠의 재생 및 복사 제어를 PMP에 구현)

  • Jeong, Yong-Jae;Moon, Kwang-Seok;Kim, Jong-Nam
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.46 no.2
    • /
    • pp.52-57
    • /
    • 2009
  • Recently, the regular service of a terrestrial digital multimedia broadcasting(T-DMB) made faster distribution of T-DMB receiver. The problem of an illegal distribution is increasing owing to a large distribution of T-DMB receiver. In this paper, we propose a watermarking and encryption method on T-DMB bit-stream for a copy and Play control to prevent an illegal distribution of T-DMB contents. We implement our proposed method on a portable multimedia player (PMP) which has T-DMB receiver. The proposed method insert the encrypted information for control of copy and play after finding padding area of program map table (PMT) and program association table (PAT) from analysis of transport stream (TS) of T-DMB. In implementation result, we can control use of contents according to information of copy and play control. The proposed method can be used to content Protection software for blocking of an illegal distribution of T-DMB contents on a mobile T-DMB receivers.

A Low Power Multi-Function Digital Audio SoC

  • Lim, Chae-Duck;Lee, Kyo-Sik
    • Proceedings of the IEEK Conference
    • /
    • 2004.06b
    • /
    • pp.399-402
    • /
    • 2004
  • This paper presents a system-on-chip prototype implementing a full integration for a portable digital audio system. The chip is composed of a audio processor block to implements audio decoding and voice compression or decompression software, a system control block including 8-bit MCU core and Memory Management Unit (MMU) a low power 16-bit ${\Sigma}{\Delta}$ CODEC, two DC-to-BC converter, and a flash memory controller. In order to support other audio algorithms except Mask ROM type's fixed codes, a novel 16-bit fixed-point DSP core with the program-download architecture is proposed. Funker, an efficient power management technique such as task-based clock management is implemented to reduce power consumption for portable application. The proposed chip has been fabricated with a 4 metal 0.25um CMOS technology and the chip area is about 7.1 mm ${\times}$ 7.1mm with 100mW power dissipation at 2.5V power supply.

  • PDF

Potential of near infrared spectroscopy for non-destructive estimation of soluble solids in growing melons

  • Ito, Hidekazu;Morimoto, Susumu;Yamauchi, Ryougo
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1525-1525
    • /
    • 2001
  • Non-destructive determination of soluble solids(Brix) in harvested fruits using near infrared(hereafter, NIR) spectroscopy has been reported by many researchers. We have just reported on non-destructive estimation of Brix in harvested melons using a NIR Systems Model 6500 spectrophotometer(Ito et al., 2000). There is a melon cultivar that is difficult to judge the harvest time from the external appearance. If we can determine Brix in growing fruits non-destructively in the field, immature fruits will not be harvested. A portable m spectrophotometer for field use has been just developed by Kubota Corporation. The spectral data of growing melons were measured by the portable spectrophotometer. A commercial program was used for multiple linear regression analysis. Brix in growing melons could be estimated by a multiple regression equation calibrated with harvested melons. Absorbances of 906 and 874 nm were included as the independent variables in the multiple regression equation, and these wavelengths are key wavelengths for non-destructive Brix determination.

  • PDF

Development of a Portable Cardiac Event Recorder (휴대용 심전도 이벤트 기록기 개발)

  • Chun, H.G.;Kim, H.C.;Lee, C.Y.;Kim, I.Y.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.187-188
    • /
    • 1998
  • A low cost, low power, portable cardiac event recorder as a tether-free biological signal processor was developed. Dual channel ECG signals are sampled at 128Hz in 12 bits resolution. Sampled data are continuously recorded in a circular buffer. If event button is pressed, 2 minutes data before and after the event are recorded in 512 Kbyte SRAM. Total 11 events can be recorded. Data can be transferred to PC through RS-232 protocol. It operates for two months by a half AA size 3.6V Lithium battery. The system size is $55\times55\times13[mm^3]$.

  • PDF

Development of Diagnostic System for Mold Oscillation in a Continuous Slab Casting Machine (연속주조기 Mold Oscillation 진단시스템 개발)

  • 이성진;전형일;이경순
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.387-392
    • /
    • 2002
  • A portable mould oscillation analyzer with an integrated computer, developed by POSCO, records the movement of the mould in every spatial direction. The system uses the gap sensors to measure the mould movement (displacement) in two horizontal directions according to the mould narrow and broad faces and the vertical strokes in the four corners of mould. The gap sensor is a non-contacting minute displacement-measuring device using the principle of high frequency eddy current loss. The mould oscillation diagnostic system integrates the gap sensors, their converters and the industrial portable computer with plug-in data acquisition boards. In an own expert module, which is included in the diagnosis program, one can obtain much information about the mould oscillation equipment.

  • PDF

Influence of Dyspepsia Dependent Ryodoraku Score Upon 'Soeum Person' Diagnosed by Portable Ryodoraku Device (소화불량에 따른 양도락 점수가 이동식 양도락기기 진단에 있어 소음인에 미치는 영향)

  • Lee, Ji In;Hur, Keun Young;Song, Ho Sueb
    • Journal of Acupuncture Research
    • /
    • v.30 no.5
    • /
    • pp.77-86
    • /
    • 2013
  • Objectives : The aim of the study was to investigate the characteristics of Ryodoraku score according to dyspepsia in diagnosed as Soeumin by 'portable Ryodoraku device'. Methods : Using Mann-Whitney U test, we divided 34 'Soeumin' patients into two group(normal and with chronic dyspepsia) and analyzed Ryodoraku score, especially in 'the spleen meridian' and 'the stomach meridian' which is belived to be related with dyspepsia. Soeumin subjects are classified by 'Sasang constitutional program' in portable Ryodoraku device. All of them complete the questionnaire regarding their Digestive conditions. 'short from leeds dyspepsia questionnaire(SF-LDQ)' made by rome III diagnostic is chosed as questionnaire. Results: 1. We found the RS measured from a group of people who has chronic dyspepsia was significantly greater than that from control group. 2. Regarding the effect of 'dyspepsia' in Ryodoraku, the mean score of the F6(stomach meridian) in the chronic dyspepsia group was significantly higher than that in the control group. 3. The mean score of the F6(stomach meridian RS) in the chronic dyspepsia group was not significantly higher than that in the control group. 4. In cases where people has chronic dyspepsia, the difference between RS measured in the right-side of a body and that in the left-side of a body was mostly greater than 40, whereas the case of difference that is less than 2 was rare. Conclusions : Portable Ryodoraku device might be used to classify enforce 'Sasang constitution', and also it might be used to analyze 'Ryodoraku data' based on characteristic clinical symptoms of four constitution diagnosis alone.