• Title/Summary/Keyword: Portable Inspection Device

Search Result 6, Processing Time 0.024 seconds

Development of Portable Vibration Signal-Based Pipe Wall Thinning Inspection Device (진동신호기반 배관감육 측정시스템 개발)

  • Han, Soon-Woo;Park, Jin-Ho;Kang, To;Sohn, Ki Sung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.545-547
    • /
    • 2014
  • The portable vibration signal-based pipe wall thinning inspection device was developed in this work. Compared to wall-thinning detection using conventional ultrasonic thickness measurement gauge, the proposed device can estimate average wall thickness of wide range and be applied to in-service pipes. The measurement principle of the device was briefly described and the configrations of hardware and software were explained. It was shown that the device can gauge average wall-thickness of test specimens with high precision.

  • PDF

The development of product inspection X-ray DR image processing system using intensifying screen (형광지를 이용한 물품검사 X-선 DR 영상처리 시스템 개발)

  • Park, Mun-kyu;Moon, Ha-jung;Lee, Dong-hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.7
    • /
    • pp.1737-1742
    • /
    • 2015
  • In the industrial field for product inspection needs not only on the surface of the product but also the internal components defect inspection. Generally, optical inspection is mainly used for item inspection from production process. However, this is only to check defect of surface it is difficult to perform inspection of goods internal. To overcome these limitations, Instead of optical device by using the portable X- ray DR image acquisition device system developed to obtain an image in real time at the same time and determine product defects. After obtaining the X- ray image, the inspection product within error range is passed after machine image processing. Also, the results and numbers are stored by users.

A Study on Development of Portable Concrete Crack Measurement Device Using Image Processing Technique and Laser Sensors (이미지 처리기법 및 레이저 센서를 이용한 휴대용 콘크리트 균열 측정 장치 개발에 관한 연구)

  • Seo, Seunghwan;Ohn, Syng-Yup;Kim, Dong-Hyun;Kwak, Kiseok;Chung, Moonkyung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.4
    • /
    • pp.41-50
    • /
    • 2020
  • Since cracks in concrete structures expedite corrosion of reinforced concrete over a long period of time, regular on-site inspections are essential to ensure structural usability and prevent degradation. Most of the safety inspections of facilities rely on visual inspection with naked eye, so cost and time consuming are severe, and the reliability of results differs depending on the inspector. In this study, a portable measuring device that can be used for safety diagnosis and maintenance was developed as a device that measures the width and length of concrete cracks through image analysis of cracks photographed with a camera. This device captures the cracks found within a close distance (3 m), and accurately calculates the unit pixel size by laser distance measurement, and automatically calculates the crack length and width with the image processing algorithm developed in this study. In measurement results using the crack image applied to the experiment, the measurement of the length of a 0.3 mm crack within a distance of 3 m was possible with a range of about 10% error. The crack width showed a tendency to be overestimated by detecting surrounding pixels due to vibration and blurring effect during the binarization process, but it could be effectively corrected by applying the crack width reduction function.

Long Life Design of SSD Test Gender by Reducing Ejecting Force (인출력 저감을 통한 SSD Test Gender의 장수명 설계)

  • Kim, Jae Kyung;Park, Hyung Suk;Lee, Ki Seok;Jeon, Euy sik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.4
    • /
    • pp.139-144
    • /
    • 2020
  • Recently, the electronic equipment industry has become active due to the continuous increase in portable storage media with high-speed information communication, and in particular, the production of SSD(Solid State Drives) for miniaturization of mobile devices and high-speed information communication has increased rapidly. When the SSD is ejecting in the SSD test gender, the necessary ejecting force must be kept constant to have a lifespan applicable to the test device. When the ejecting force increased, it leads to wear of the link for ejecting, which causes a problem in that repeated durability decreases and the ejecting of the SSD becomes impossible. In this paper, the repeated durability test analysis according to the material and the reducing ejecting force design were performed to increase the life of the test gender for SSD inspection. The wear level of the pusher head and ejector was analyzed through repeated durability tests according to the material of the pusher head. The validity of the design was verified through the ejecting force test and repeated durability test of the Test gender, which was designed by carrying out the design to reduce the size and ejecting force of the test gender.

Using Hyperspectral Fluorescence Spectra of Deli Commodities to Select Wavelengths for Surveying Deli Food Contact Surfaces

  • Lefcourt, Alan M.;Beck, Elizabeth A.;Lo, Y. Martin;Kim, Moon S.
    • Journal of Biosystems Engineering
    • /
    • v.40 no.2
    • /
    • pp.145-152
    • /
    • 2015
  • Purpose: The inability to adequately judge the efficacy of cleaning and sanitation procedures in deli departments is a recognized food safety concern. In a prior study, our research group demonstrated that visual inspection of cleaned produce processing surfaces could be enhanced through the use of a portable fluorescence imaging device that detected residual produce residues. Methods: To explore the feasibility of using fluorescence imaging to similarly detect residual deli residues, spectra of American, Cheddar, Provolone, and Swiss cheeses and of processed chicken, ham, roast beef, and turkey were acquired using a laboratory hyperspectral imaging system. Circular punches of these commodities were placed onto stainless steel and high density polyethylene coupons for imaging. The coupon materials were selected to represent common surfaces found in deli departments. Results: Analysis of hyperspectral fluorescence images showed that cheeses exhibited peaks in the blue-green region and at around 675 nm. Meats exhibited peaks in the blue-green region with one of four ham and one of four chicken brands exhibiting peaks at around 675 nm, presumably due to use of plant-derived additives. When commodities were intermittently imaged over two weeks, locations of spectral peaks were preserved while intensity of peaks at shorter wavelengths increased with time. Conclusion: These results demonstrate that fluorescence imaging techniques have the potential to enhance surface hygiene inspection in deli departments and, given the immediate availability of imaging results, to help optimize routine cleaning procedures.

Development of an Electro Impedance Spectroscopy device for EDLC super capacitor characterization in a mass production line (EDLC 슈퍼 캐피시터 특성 분석을 위한 양산용 전기화학 분석 장치 개발)

  • Park, Chan-Hee;Lee, Hye-In;Kim, Sang-Jung;Lee, Jung-Ho;Kim, Sung-Jin;Lee, Hee-Gwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5647-5654
    • /
    • 2012
  • In this paper, we developed an electro impedance spectroscopy (EIS) device, which are primarily used for the analysis of fuel cells or batteries, to widen its coverage to the next generation super capacitor EDLC characterization. The developed system was composed of a signal generator that can generate various signal patterns, a potentiostatic generator, and a high speed digital filter for signal processing and measurement program. The developed system is portable, which is not only suitable laboratory use but also for mass production line. The special features of the system include a patterned output signal from 0.01 to 20 kHz, and a fast Fourier transform (FFT) analysis of current signals, both of which are acquired simultaneously. Our tests showed similar results after comparing the analysis from our newly-developed device showing the characteristics of EDLC complex impedance and the analysis from an equivalent impedance which was applied to an equivalent circuit. Now, we can expect a fast inspection time from the application of the present system to the super capacitor production line, based on time-varying changes in electrochemical impedance.