• Title/Summary/Keyword: Porous ratio

Search Result 596, Processing Time 0.024 seconds

Sound Absorbing Characteristics of Porous Concrete according to Mixing Factor (배합요인에 따른 포러스 콘크리트의 흡음특성)

  • 이준;박승범;권혁준;김경훈;장영일;김형석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.489-492
    • /
    • 2003
  • The results of an experiment on the sound absorption of the porous concrete and its influence on the compressive strength are reported in this paper. Two different sizes of coarse aggregate of 5~13, 13~20mm, and the design void ratio of 20, 25 and 30 percent for a given size of aggregate were used. In the compressive strength, an aggregate of the size of 5~13mm is much higher strength than that of the 13~20mm, In the sound absorption experiment, the size of aggregate of 5~l0mm is much higher sound absorption than that of the 13~20mm. The sound absorption ratio was increased as the design void ratio. As a result, Porous concrete sufficiently have the performance of sound absorption.

  • PDF

Fundamental Study on the Development of Porous Concrete Using Super Absorbent Polymer (고흡수성 수지를 활용한 다공질 구조 콘크리트 개발을 위한 기초적 연구)

  • Jo, Jae-Hyun;Baek, Sung-Jin;Lim, Gun-Su;Han, Jun-Hiu;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.217-218
    • /
    • 2023
  • This study is to develop porous concrete using super absorbent polymer, which possesses insolubility and high absorption capacity, as a substitute material for lightweight soil. Various mixtures were prepared using aggregates, cement, mixing water, and super absorbent polymer, and the absorption ratio and compressive strength were examined for each mixture. As the amount of super absorbent polymer added increased, the absorption ratio also increased, reaching up to 35-105%. However, the compressive strength decreased by 49.5% to 65.3%. This is believed to be due to the inherent properties of super absorbent polymer, which led to an increase in the absorption ratio but, in turn, reduced the binding strength of cement paste particles, resulting in a decrease in compressive strength.

  • PDF

Preparation of Porous PLGA Microfibers Using Gelatin Porogen Based on a Glass Capillary Device (젤라틴 기공유도물질과 유리모세관 장치를 이용한 다공성 PLGA 미세섬유의 제조)

  • Kim, Chul Min;Kim, Gyu Man
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.1
    • /
    • pp.63-67
    • /
    • 2016
  • We present a method of fabricating poly (lactic-co-glycolic acid) (PLGA) porous microfibers using a pore template. PLGA microfibers were synthesized using a glass capillary tube in a poly-(dimethylsiloxane) (PDMS) microfluidic chip. Gelatin solution was used as a porous template to prepare pores in microfibers. Two phases of PLGA solutions in different solvents-DMSO (dimethyl sulfoxide) and DCM (dichloromethane)-were used to control the porosity and strength of the porous microfibers. The porosity of the PLGA microfibers differed depending on the ratio of flow rates in the two phases. The porous structure was formed in a spiral shape on the microfiber. The porous structure of the microfiber is expected to improve transfer of oxygen and nutrients, which is important for cell viability in tissue engineering.

Effect of Reinforcing Fiber on Mechanical Properties and Chemical Resistance of Porous Concrete with Hwang-toh (황토를 포함한 다공성 식생콘크리트의 역학적 특성 및 내약품성에 미치는 보강섬유의 효과)

  • Lee, Jin-Hyung;Park, Chan-Gi;Park, Jong-Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2A
    • /
    • pp.105-113
    • /
    • 2011
  • This study evaluated the effects of fibers on the mechanical properties and chemical solution resistance of porous concrete with fiber type (jute, pulp, PVA and nylon fiber) and fiber volume fraction (0.0%, 0.1%, 0.2%, 0.3%). The tests that were carried out to analysis the properties of porous concrete included compressive strength, void ratio, pH value, and chemical solution exposure with varying type and volume fraction of fiber were conducted. The type and volume fraction of fiber also affected the void ratio, compressive strength, flexural strength and chemical solution exposure. Increased volume fractions of fiber resulted in improved properties of the compressive strength, flexural strength and void ratio. However, the difference between the measured pH value and chemical resistance of porous concrete with fiber type and volume fraction was not significant.

Physical and Mechanical Properties of Non-Cement Porous Concrete with Alkali-Activator Contents (알칼리활성화제 치환율에 따른 무시멘트 다공성 콘크리트의 물리·역학적 특성)

  • Kim, Dong-Hyun;Kim, Chun-Soo;Park, Chan Gi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.2
    • /
    • pp.59-64
    • /
    • 2013
  • The present study is to evaluate physical and mechanical properties of porous concrete having non cement that mainly causes carbon emission. This study aims to explore eco-friendly concrete technology capable of reducing the amount of carbon emission due to the use of normal cement by substituting it with non cement porous concrete to which alkali-activator and blast-furnace slag powder are impregnated. As experimental variables, 5 %, 6 %, 7 %, 8 %, 9 % and 10 % of alkali-activator were substituted as binders and applied. Testing evaluated in this study were pH value, void ratio, compressive strength and residual compressive strength shown after being immersed in $H_2SO_4$ solution and $Na_2SO_4$ solution. The test results were compared with those tested with the use of porous concrete to which 400 $kg/m^3$ of unit cement amount was applied as binder. In consequence, it was concluded that; as for pH value, it was decreased than was the case in which cement was used, but increased with the more the use of alkali activator; as for void ratio and compressive strength, the mix proportion in which 9 % and 10 % of alkali activator were applied in terms of substitution ratio showed the result similar to the mixture in which 400 $kg/m^3$ of unit cement ratio was applied; and, as for residual compressive strength in the case of being immersed in $H_2SO_4$ solution and $Na_2SO_4$ solution, the compressive strength was increased, thus leading to improved chemical resistance.

Mechanical Characteristics of Porous Concrete using Recycled-Aggregate (순환골재를 이용한 투수성 콘크리트의 역학특성)

  • You, Seung-Kyong;Yu, Nam-Jae;Cho, Sung-Min;Shim, Min-Bo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.2
    • /
    • pp.17-20
    • /
    • 2007
  • In this study, a series of uniaxial unconfined compression test and constant-head test were performed to investigate the mechanical characteristics of porous concrete using recycled-aggregate for the varying unit weight and water-cement ratio. To enhance the permeability of the porous concrete, the recycled-aggregate with similar grain size in the range of $40{\pm}5mm$ was used and water-cement ratio that leads to the lean-mix was adapted. The mechanical characteristics of the porous concrete cured for 3 days were examined; the compressive strength and $E_{50}$ showed their maximum values with 40% water-cement ratio and $1.8t/m^3$ unit weight and the permeability coefficient was averagely measured in the range of $0.9{\times}10^0cm/sec$ regardless of water-cement ratio and unit weight.

  • PDF

Static analysis of non-uniform heterogeneous circular plate with porous material resting on a gradient hybrid foundation involving friction force

  • Rad, A. Behravan;Farzan-Rad, M.R.;Majd, K. Mohammadi
    • Structural Engineering and Mechanics
    • /
    • v.64 no.5
    • /
    • pp.591-610
    • /
    • 2017
  • This paper is concerned with the static analysis of variable thickness of two directional functionally graded porous materials (FGPM) circular plate resting on a gradient hybrid foundation (Horvath-Colasanti type) with friction force and subjected to compound mechanical loads (e.g., transverse, in-plane shear traction and concentrated force at the center of the plate).The governing state equations are derived in terms of displacements based on the 3D theory of elasticity, assuming the elastic coefficients of the plate material except the Poisson's ratio varying continuously throughout the thickness and radial directions according to an exponential function. These equations are solved semi-analytically by employing the state space method (SSM) and one-dimensional differential quadrature (DQ) rule to obtain the displacements and stress components of the FGPM plate. The effect of concentrated force at the center of the plate is approximated with the shear force, uniformly distributed over the inner boundary of a FGPM annular plate. In addition to verification study and convergence analysis, numerical results are displayed to show the effect of material heterogeneity indices, foundation stiffness coefficients, foundation gradient indices, loads ratio, thickness to radius ratio, compressibility, porosity and friction coefficient of the foundation on the static behavior of the plate. Finally, the responses of FG and FG porous material circular plates to compound mechanical loads are compared.

Effect of Aluminum Addition on Porosity and Flexural Strength of Porous Self-Bonded Silicon Carbide Ceramics (알루미늄 첨가가 다공질 Self-Bonded SiC 세라믹스의 기공률과 꺾임강도에 미치는 영향)

  • Lim, Kwang-Young;Kim, Young-Wook;Woo, Sang-Kuk;Han, In-Sub
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.5
    • /
    • pp.520-524
    • /
    • 2009
  • Porous self-bonded silicon carbide (SBSC) ceramics were fabricated at temperatures ranging from 1750 to $1850^{\circ}C$ using SiC, Si, C as starting materials and Al as an optional sintering additive. The effect of Al addition on the porosity and strength of the porous SBSC ceramics were investigated as functions of sintering temperature and Si:C ratio. The porosity increased with decreasing the Si:C ratio and increasing the sintering temperature. It was possible to fabricate SBSC ceramics with porosities ranging from 37% to 44% by adjusting the Si:C ratio and the sintering temperature. Addition of Al additive promoted densification and necking between SiC grains, resulting in improved strength. Typical flexural strengths of SBSC ceramics with and without Al addition were 44 MPa and 34MPa, respectively.

A Study on the Analysis of Surface Characteristics According to intermittent Ratio of Discontinuous Grinding Wheel with Multi-Porous Grooves (다기공 연삭숫돌의 단속비에 의한 표면특성 분석에 관한 연구)

  • Kim, Jeong-Du;Kang, Youn-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.6
    • /
    • pp.44-51
    • /
    • 1997
  • Crinding of stainless steel, aluminium alloy, copper alloy, and titanium alloy are difficult to obtain high quality finish, because they have the mechanical properties such as low hardness, high toughness. The low hardness and the high toughness result in the loading of wheel and the poor surface finish. In order to perform the grinding operations for these sorts of materials easily, the discontinuous grinding wheel wiht multi-porous grooves has been newly developed. The multi-porous grooves inthe discontinuous grinding wheel were formed during grinding wheel manufacturing process. In this paper, discontinuous grinding wheels having intermittent ratio 0.66, 0.81 and number of grooves 18,32 have been manufactured and grinding surface characteristics of these grinding wheels for SUS304 have been analyzed. Discontinuous grinding temperature according to intermittent ratiohas been also estimated by simulation. The discontinuous grinding wheels increase the grinding performance considerably. It is desirable to use the discontinuous grinding wheel in grinding the materials with high efficiency and accuracy.

  • PDF

Void Ratio, Compressive Strength and Freezing and Thawing Resistance of Natural Jute Fiber Reinforced Non-Sintering Inorganic Binder Porous Concrete (자연마섬유보강 비소성 무기결합재 다공성 콘크리트의 공극률, 압축강도 및 동결융해저항성 평가)

  • Kim, Hwang Hee;Kim, Chun Soo;Jeon, Ji Hong;Park, Chan Gi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.2
    • /
    • pp.67-73
    • /
    • 2015
  • This study evaluated the effects of fibers on the void ratio, compressive strength and repeated freezing and thawing resistance of porous vegetation concrete with binder type (non-sintering inorganic binder and blast furnace slag cement) and natural jute fiber volume fraction (0.0 %, 0.1 % and 0.2 %). The natural jute fiber volume fraction affected the void ratio, compressive strength and repeated freezing and thawing resistance. Added of natural jute fiber resulted in improved properties of the void ratio, compressive strength and freezing and thawing resistance. Also, the both compressive strength and freezing and thawing resistance increased with natural jute fiber volume fraction up to 0.1 % and then decreased with fiber volume fraction at 0.2 %.